DTC parameters
The Toyota RAV4 has 53 DTC parameters.
● Confirmed◆ In testing○ Supported× Not supported
2nd air monitor avail RAV4_2ND_AIR_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 20 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
2nd air monitor incomplete RAV4_2ND_AIR_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 28 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
A/C monitor avail RAV4_A_C_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 19 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
A/C monitor incomplete RAV4_A_C_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 27 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Catalyst monitor avail RAV4_CATALYST_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 23 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Catalyst monitor incomplete RAV4_CATALYST_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 31 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Complete parts monitor_avail RAV4_COMPLETE_PARTS_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 13 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
01 31 - Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2007, 2011 to 2012, 2014 to 2015, 2017, 2021. Supported for 2008, 2010, 2013, 2018 to 2020, 2022 to 2025.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Request
01 21 - Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
EGR/VVT monitor avail RAV4_EGR_VVT_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 16 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
EGR/VVT monitor incomplete RAV4_EGR_VVT_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 24 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed
Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.
- Request
01 4E - Service 01
PID 4E - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2012. Supported for 2013, 2019, 2021, 2023 to 2025.
EVAP monitor avail RAV4_EVAP_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 21 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
EVAP monitor_icmpl RAV4_EVAP_MONITOR_ICMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 29 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Fuel system monitor_avail RAV4_FUEL_SYSTEM_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 14 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Heated catalyst monitor avail RAV4_HEATED_CATALYST_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 22 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Heated catalyst monitor incomplete RAV4_HEATED_CATALYST_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 30 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
Pelican can show this parameter as the checkEngineLightOn.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
MIL RAV4_MILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 0 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2007, 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
MIL ON run distance RAV4_MILON_RUN_DISTANCEConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bits 48 to 63 of the reply, 16 bits.
0x0000 = 0 → 0 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Misfire monitor avail RAV4_MISFIRE_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 15 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
Pelican can show this parameter as the storedDTCCount.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127
- Unit
- Number
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Number of emission DTC RAV4_NUMBER_OF_EMISSION_DTCConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bits 1 to 7 of the reply, 7 bits.
0b0000000 = 0 → 0
- Formula
val- Range
- 0 to 127
- Unit
- Number
Confirmed for 2007, 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Request
01 30 - Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
O2S(A/FS) heater monitor avail RAV4_O2S_A_FS__HEATER_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 17 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
O2S(A/FS) heater monitor incomplete RAV4_O2S_A_FS__HEATER_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 25 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
O2S(A/FS) monitor avail RAV4_O2S_A_FS__MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 18 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
O2S(A/FS) monitor incomplete RAV4_O2S_A_FS__MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bit 26 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Running time from MIL ON RAV4_RUNNING_TIME_FROM_MIL_ONConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1994 to 2006, 2008 to 2010, 2013, 2016, 2018 to 2026
Example reply from a 2017 Toyota RAV4.
Bits 64 to 79 of the reply, 16 bits.
0x0000 = 0 → 0 min
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2011 to 2012, 2015, 2017. In testing for 1994 to 2001, 2003 to 2006, 2008 to 2010, 2013, 2016, 2018. Supported for 2007, 2014. Not supported for 2002, 2019 to 2021, 2023, 2025.
Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Request
01 4D - Service 01
PID 4D - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2012. Supported for 2008, 2013, 2019 to 2025.
DTCs › Status
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
DTCs › Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2012. Supported for 2007 to 2008, 2010 to 2011, 2013 to 2015, 2017 to 2025.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes