HV battery charge FORMENTOR_HVBAT_SOC_V2Confirmed

Pelican can show this parameter as the state of charge.

  • Request22 02 8C
  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

0xBE = 190 → (190 × 100 ÷ 255) = 74.509804 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

State of charge

HV battery charge FORMENTOR_HVBAT_SOC_V2Confirmed

Pelican can show this parameter as the state of charge.

  • Request22 02 8C
  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

0xBE = 190 → (190 × 100 ÷ 255) = 74.509804 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

State of charge FORMENTOR_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 02 8C
  • Service 22DID 028C
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing for 2020 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 250)
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

State of health

HV battery health FORMENTOR_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Request22 51 E0
  • Service 22DID 51E0
  • Module7E5 → 7ED
  • Every30 s
  • Testing for 2020 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.127 − 1798.574)
Range
-1798.574 to 6524 %
Unit
%

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

Fuel tank level

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Request01 2F
  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2025. Supported for 2021, 2023 to 2024, 2026.

Speed

Vehicle speed FORMENTOR_VSS_7E1

Pelican can show this parameter as the speed.

  • Request22 F4 0D
  • Service 22DID F40D
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2020 to 2024, 2026. Not supported for 2025.

Vehicle speed FORMENTOR_VSS_V2Confirmed

Pelican can show this parameter as the speed.

  • Request22 F4 0D
  • Service 22DID F40D
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing for 2020 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Request01 0D
  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2022, 2025. Supported for 2021, 2023 to 2024, 2026.

Electric range

Range remaining FORMENTOR_RANGE_V2Confirmed

Pelican can show this parameter as the electric range.

  • Request22 2A B6
  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

0x00C6 = 198 → 198 mi

Formula
val
Range
0 to 65535 mi
Unit
mi

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Odometer

Odometer FORMENTOR_PQ35_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Request22 22 03
  • Service 22DID 2203
  • Module714 → 77E
  • Every30 s
  • Testing for 2020 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Cupra Formentor.

Bits 0 to 23 of the reply, 24 bits.

0x0069A4 = 27044 → 27,044 km

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2022, 2025. In testing for 2020 to 2021. Not supported for 2023 to 2024, 2026.

Odometer FORMENTOR_ODO_3

Pelican can show this parameter as the odometer.

  • Request22 10 3D
  • Service 22DID 103D
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2020 to 2024, 2026. Not supported for 2025.

Odometer FORMENTOR_MQB_TCM_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Request22 38 41
  • Service 22DID 3841
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 31 of the reply, 32 bits.

0x03EA0100 = 65667328 → (65667328 ÷ 10) = 6,566,732.8 km

Formula
(val ÷ 10)
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

Odometer #2 FORMENTOR_MQB_TCM_ODO_2Confirmed

Pelican can show this parameter as the odometer.

  • Request22 38 87
  • Service 22DID 3887
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2020 to 2023, 2025 to 2026

Bits 0 to 31 of the reply, 32 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 429496729.5 km
Unit
km

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

Odometer #3 FORMENTOR_PQ35_ODO_3Confirmed

Pelican can show this parameter as the odometer.

  • Request22 10 1A
  • Service 22DID 101A
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 23 of the reply, 24 bits.

0x003000 = 12288 → 12,288 km

Formula
val
Range
0 to 16777215 km
Unit
km

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

Odometer, mileage, HR FORMENTOR_ODO_MILEAGE_HRConfirmed

Pelican can show this parameter as the odometer.

  • Request22 22 B8
  • Service 22DID 22B8
  • Module714 → 77E
  • Every30 s
  • Testing for 2020 to 2021, 2023 to 2024

Example reply from a 2026 Cupra Formentor.

Bits 0 to 31 of the reply, 32 bits.

0x0029B927 = 2734375 → (2734375 ÷ 1000) = 2,734.375 km

Formula
(val ÷ 1000)
Range
0 to 4294967 km
Unit
km

Confirmed for 2022, 2025 to 2026. In testing for 2020 to 2021, 2023 to 2024.

Commanded lambda

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2022 to 2025. Supported for 2021, 2026.

Distance since trouble codes were cleared

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Request01 31
  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2022, 2024 to 2025. Supported for 2021, 2023, 2026.

Engine coolant temperature

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2025. Supported for 2021, 2026.

Engine load

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2025. Supported for 2021, 2026.

Engine oil temperature

Engine oil temperature FORMENTOR_EOT_FC00Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 11 BD
  • Service 22DID 11BD
  • ModuleFC00 → FE0076
  • Every5 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Fuel rate

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Request01 5E
  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3212.75 L/h
Unit
L/h

Confirmed for 2022 to 2025. Supported for 2026.

O2 lambda

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2022 to 2025. Supported for 2021, 2026.

Short term fuel trim

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2022 to 2025. Supported for 2021, 2026.

Starter battery voltage

12V battery voltage FORMENTOR_AUX_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

0x23A8 = 9128 → (9128 ÷ 1000 + 4) = 13.128 V

Formula
(val ÷ 1000 + 4)
Range
0 to 69 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2022. Supported for 2021, 2023 to 2026.

DC battery voltage FORMENTOR_DC_BATTERY_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 1E 3B
  • Service 22DID 1E3B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Traction battery voltage

HV battery voltage FORMENTOR_HVBAT_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Request22 1E 3B
  • Service 22DID 1E3B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

0x05BC = 1468 → (1468 ÷ 4) = 367 V

Formula
(val ÷ 4)
Range
0 to 1000 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

Transmission fluid temperature

Automatic transmission fluid temperature, variant 2 FORMENTOR_MQB_TCM_ATF_T_VAR_2_DSG_S_TRONICConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 21 04
  • Service 22DID 2104
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

0x0E = 14 → (14 − 40) = -26 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

Transmission fluid temperature 2 FORMENTOR_ATF_T_2

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 38 BF
  • Service 22DID 38BF
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2024, 2026. Not supported for 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.