Climate parameters
The Cupra Formentor has 12 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/C compressor power, actual FORMENTOR_AC_CMPR_PWR_ACTConfirmed
- Request
22 08 00 - Service 22
DID 0800 - Module
746 → 7B0 - Every
5 s - Testing for 2020 to 2024
Example reply from a 2026 Cupra Formentor.
Bits 40 to 55 of the reply, 16 bits.
0x0000 = 0 → 0 W
- Formula
val- Range
- 0 to 65535 W
- Unit
- W
Confirmed for 2025 to 2026. In testing for 2020 to 2021. Not supported for 2022 to 2024.
A/C refrigerant pressure, sensor 1 FORMENTOR_AC_REFRIG_P_SENS1Confirmed
- Request
22 4E EF - Service 22
DID 4EEF - Module
746 → 7B0 - Every
5 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 0 to 15 of the reply, 16 bits.
0x028A = 650 → (650 × 88 ÷ 10000) = 5.72 bar
- Formula
(val × 88 ÷ 10000)- Range
- 0 to 576.708 bar
- Unit
- bar
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
A/C refrigerant temperature, sensor 1 FORMENTOR_AC_REFRIG_T_SENS1Confirmed
- Request
22 4E EF - Service 22
DID 4EEF - Module
746 → 7B0 - Every
5 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 16 to 31 of the reply, 16 bits.
0x027C = 636 → (636 × 10 ÷ 100 − 40) = 23.6 °C
- Formula
(val × 10 ÷ 100 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
A/C refrigerant temperature, sensor 1 interior FORMENTOR_AC_REFRIG_T_SENS1_INTConfirmed
- Request
22 4E EF - Service 22
DID 4EEF - Module
746 → 7B0 - Every
5 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 32 to 47 of the reply, 16 bits.
0x0296 = 662 → (662 × 10 ÷ 100 − 40) = 26.2 °C
- Formula
(val × 10 ÷ 100 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2025 to 2026. In testing for 2020 to 2021. Supported for 2022 to 2024.
Cabin humidity FORMENTOR_CABIN_HUMIDITYConfirmed
- Request
22 27 C4 - Service 22
DID 27C4 - Module
746 → 7B0 - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 32 to 39 of the reply, 8 bits.
0x6A = 106 → (106 ÷ 2) = 53 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
CO2 content interior FORMENTOR_CABIN_CO2Confirmed
- Request
22 42 DB - Service 22
DID 42DB - Module
746 → 7B0 - Every
5 s - Testing for 2020 to 2021, 2025 to 2026
Example reply from a 2024 Cupra Formentor.
Bits 8 to 15 of the reply, 8 bits.
0xFE = 254 → (254 × 100) = 25,400
- Formula
(val × 100)- Range
- 0 to 25500
- Unit
- Number
Confirmed for 2022 to 2024. In testing for 2020 to 2021. Not supported for 2025 to 2026.
Outside temperature FORMENTOR_AATConfirmed
- Request
22 26 09 - Service 22
DID 2609 - Module
746 → 7B0 - Every
5 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 0 to 7 of the reply, 8 bits.
0x8E = 142 → (142 ÷ 2 − 50) = 21 °C
- Formula
(val ÷ 2 − 50)- Range
- -50 to 77.5 °C
- Unit
- °C
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
Recirculation flap actual position FORMENTOR_MQB_RECIRC_FLAP_ACTConfirmed
- Request
22 26 1E - Service 22
DID 261E - Module
746 → 7B0 - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 0 to 15 of the reply, 16 bits.
0x0279 = 633 → 633
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
Recirculation flap fresh air threshold FORMENTOR_MQB_RECIRC_FLAP_FRESH_THRConfirmed
- Request
22 26 20 - Service 22
DID 2620 - Module
746 → 7B0 - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 0 to 15 of the reply, 16 bits.
0x00A3 = 163 → 163
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
Recirculation flap target position FORMENTOR_MQB_RECIRC_FLAP_TRGConfirmed
- Request
22 26 1F - Service 22
DID 261F - Module
746 → 7B0 - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 0 to 15 of the reply, 16 bits.
0x0278 = 632 → 632
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
Recirculation flap threshold FORMENTOR_MQB_RECIRC_FLAP_THRConfirmed
- Request
22 26 21 - Service 22
DID 2621 - Module
746 → 7B0 - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 0 to 15 of the reply, 16 bits.
0x035A = 858 → 858
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
Windshield temperature FORMENTOR_WINDSHIELD_TConfirmed
- Request
22 27 C4 - Service 22
DID 27C4 - Module
746 → 7B0 - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 0 to 7 of the reply, 8 bits.
0x82 = 130 → (130 × 0.576 − 38.8) = 36.08 °C
- Formula
(val × 0.576 − 38.8)- Range
- -38.8 to 108.08 °C
- Unit
- °C
Confirmed for 2022 to 2026. In testing for 2020 to 2021.