Cupra Formentor

Transmission parameters

The Cupra Formentor has 44 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

All-wheel drive clutch blockage degree FORMENTOR_MQB_HAL_CLUTCH_BLOCKConfirmed

  • Request22 18 0A
  • Service 22DID 180A
  • Module713 → 77D
  • Every1 s
  • Testing for 2020 to 2021, 2024

Example reply from a 2026 Cupra Formentor.

Bit 15 of the reply.

0b0 = 0 → (0 × 8) = 0

Formula
(val × 8)
Range
0 to 1
Unit
Off or on

Confirmed for 2022 to 2023, 2025 to 2026. In testing for 2020 to 2021, 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Adaptation counter PF lockup clutch FORMENTOR_ADPT_CNT_PF_LOCKUP

  • Request22 11 03
  • Service 22DID 1103
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, clutch a FORMENTOR_ADPT_CNT_CLU

  • Request22 70 85
  • Service 22DID 7085
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, clutch b FORMENTOR_ADPT_CNT_CLU_B

  • Request22 70 89
  • Service 22DID 7089
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, clutch c FORMENTOR_ADPT_CNT_CLU_C

  • Request22 70 8D
  • Service 22DID 708D
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, clutch d FORMENTOR_ADPT_CNT_CLU_D

  • Request22 70 91
  • Service 22DID 7091
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, clutch e FORMENTOR_ADPT_CNT_CLU_E

  • Request22 70 95
  • Service 22DID 7095
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, fast fill time, clutch a FORMENTOR_ADPT_CNT_FAST_FILL

  • Request22 70 87
  • Service 22DID 7087
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, fast fill time, clutch b FORMENTOR_ADPT_CNT_FAST_FILL_B

  • Request22 70 8B
  • Service 22DID 708B
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, fast fill time, clutch c FORMENTOR_ADPT_CNT_FAST_FILL_C

  • Request22 70 8F
  • Service 22DID 708F
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, fast fill time, clutch d FORMENTOR_ADPT_CNT_FAST_FILL_D

  • Request22 70 93
  • Service 22DID 7093
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation counter, fast fill time, clutch e FORMENTOR_ADPT_CNT_FAST_FILL_E

  • Request22 70 97
  • Service 22DID 7097
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Adaptation inflation current PF lockup clutch FORMENTOR_ADPT_INFLATION

  • Request22 11 02
  • Service 22DID 1102
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 mA
Unit
mA

In testing for 2020 to 2024, 2026. Not supported for 2025.

All-wheel drive clutch blockage degree FORMENTOR_MQB_HAL_CLUTCH_BLOCKConfirmed

  • Request22 18 0A
  • Service 22DID 180A
  • Module713 → 77D
  • Every1 s
  • Testing for 2020 to 2021, 2024

Example reply from a 2026 Cupra Formentor.

Bit 15 of the reply.

0b0 = 0 → (0 × 8) = 0

Formula
(val × 8)
Range
0 to 1
Unit
Off or on

Confirmed for 2022 to 2023, 2025 to 2026. In testing for 2020 to 2021, 2024.

All-wheel drive clutch fully open FORMENTOR_MQB_HAL_CLUTCH_OPENConfirmed

  • Request22 18 0A
  • Service 22DID 180A
  • Module713 → 77D
  • Every1 s
  • Testing for 2020 to 2021, 2024

Example reply from a 2026 Cupra Formentor.

Bit 2 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2022 to 2023, 2025 to 2026. In testing for 2020 to 2021, 2024.

Clutch 1 lower adaptation point FORMENTOR_CLU_1_LO_ADPT_POINT

  • Request22 11 20
  • Service 22DID 1120
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1000)
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2020 to 2024, 2026. Not supported for 2025.

Clutch 1 nominal pressure FORMENTOR_CLU_1_NOMINAL_P

  • Request22 12 5C
  • Service 22DID 125C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 bar
Unit
bar

In testing for 2020 to 2024, 2026. Not supported for 2025.

Clutch 1 upper adaptation point FORMENTOR_CLU_1_HI_ADPT_POINT

  • Request22 11 24
  • Service 22DID 1124
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1000)
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2020 to 2024, 2026. Not supported for 2025.

Clutch 2 lower adaptation point FORMENTOR_CLU_2_LO_ADPT_POINT

  • Request22 11 21
  • Service 22DID 1121
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1000)
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2020 to 2024, 2026. Not supported for 2025.

Clutch 2 upper adaptation point FORMENTOR_CLU_2_HI_ADPT_POINT

  • Request22 11 25
  • Service 22DID 1125
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1000)
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2020 to 2024, 2026. Not supported for 2025.

Clutch overheating, clutch FORMENTOR_CLU_OVERHEATING_CLU

  • Request22 17 FD
  • Service 22DID 17FD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Clutch temperature FORMENTOR_CLU_T

  • Request22 12 59
  • Service 22DID 1259
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2024, 2026. Not supported for 2025.

Dynamic shift program FORMENTOR_DYNAMIC_SHIFT

  • Request22 21 15
  • Service 22DID 2115
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fast fill time, clutch a FORMENTOR_FAST_FILL_TIME_CLU

  • Request22 70 86
  • Service 22DID 7086
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 2)
Range
-256 to 254 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fast fill time, clutch b FORMENTOR_FAST_FILL_TIME_CLU_B

  • Request22 70 8A
  • Service 22DID 708A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 2)
Range
-256 to 254 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fast fill time, clutch c FORMENTOR_FAST_FILL_TIME_CLU_C

  • Request22 70 8E
  • Service 22DID 708E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 2)
Range
-256 to 254 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fast fill time, clutch d FORMENTOR_FAST_FILL_TIME_CLU_D

  • Request22 70 92
  • Service 22DID 7092
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 2)
Range
-256 to 254 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fast fill time, clutch e FORMENTOR_FAST_FILL_TIME_CLU_E

  • Request22 70 96
  • Service 22DID 7096
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 2)
Range
-256 to 254 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fill pressure, clutch a FORMENTOR_FILL_P_CLU

  • Request22 70 84
  • Service 22DID 7084
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 10)
Range
-1280 to 1270
Unit
Raw value

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fill pressure, clutch b FORMENTOR_FILL_P_CLU_B

  • Request22 70 88
  • Service 22DID 7088
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 10)
Range
-1280 to 1270
Unit
Raw value

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fill pressure, clutch c FORMENTOR_FILL_P_CLU_C

  • Request22 70 8C
  • Service 22DID 708C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 10)
Range
-1280 to 1270
Unit
Raw value

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fill pressure, clutch d FORMENTOR_FILL_P_CLU_D

  • Request22 70 90
  • Service 22DID 7090
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 10)
Range
-1280 to 1270
Unit
Raw value

In testing for 2020 to 2024, 2026. Not supported for 2025.

Fill pressure, clutch e FORMENTOR_FILL_P_CLU_E

  • Request22 70 94
  • Service 22DID 7094
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 10)
Range
-1280 to 1270
Unit
Raw value

In testing for 2020 to 2024, 2026. Not supported for 2025.

Launch control counter, clutch 1 FORMENTOR_LAUNCH_CTRL_CNT_CLU_1

  • Request22 38 C0
  • Service 22DID 38C0
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Shift in progress, selected gear FORMENTOR_SHIFT_PROCCESS

  • Request22 70 D1
  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Shift in progress, target gear FORMENTOR_SHIFT_PROCCESS_TGT

  • Request22 70 D1
  • Service 22DID 70D1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Specified torque clutch 1 - data FORMENTOR_SPEC_TQ_CLU_1_DATA

  • Request22 21 42
  • Service 22DID 2142
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2020 to 2024, 2026. Not supported for 2025.

Specified torque clutch 2 - data FORMENTOR_SPEC_TQ_CLU_2_DATA

  • Request22 21 43
  • Service 22DID 2143
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638 to 1638 N·m
Unit
N·m

In testing for 2020 to 2024, 2026. Not supported for 2025.

Time since shift FORMENTOR_TIME_SINCE_SHIFT

  • Request22 10 33
  • Service 22DID 1033
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 30)
Range
0 to 7650 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter amplification FORMENTOR_TQ_CONV

  • Request22 21 30
  • Service 22DID 2130
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 100)
Range
0 to 2.55
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter lockup clutch adaptation count FORMENTOR_ADPT_CNT_TSF_LOCKUP

  • Request22 11 01
  • Service 22DID 1101
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2020 to 2024, 2026. Not supported for 2025.

Torque converter lockup clutch fill time adaptation FORMENTOR_ADPT_INFLATION_TIME

  • Request22 11 00
  • Service 22DID 1100
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 ms
Unit
ms

In testing for 2020 to 2024, 2026. Not supported for 2025.

Transmission drag torque FORMENTOR_TCM_DRAG_TQ

  • Request22 10 21
  • Service 22DID 1021
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2024, 2026. Not supported for 2025.

Transmission fluid temperature 2 FORMENTOR_ATF_T_2

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 38 BF
  • Service 22DID 38BF
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2020 to 2024, 2026. Not supported for 2025.

Transmission torque losses FORMENTOR_TCM_TQ_LOSSES

  • Request22 10 22
  • Service 22DID 1022
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2020 to 2024, 2026. Not supported for 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.