Cupra Formentor

Battery parameters

The Cupra Formentor has 173 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage FORMENTOR_AUX_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

0x23A8 = 9128 → (9128 ÷ 1000 + 4) = 13.128 V

Formula
(val ÷ 1000 + 4)
Range
0 to 69 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V battery adapted capacity FORMENTOR_AUX_BAT_CAPConfirmed

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 176 to 183 of the reply, 8 bits.

0x3B = 59 → 59 Ah

Formula
val
Range
0 to 100 Ah
Unit
Ah

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery aging by capacity FORMENTOR_AUX_BAT_AGE_CAPConfirmed

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 160 to 167 of the reply, 8 bits.

0x64 = 100 → 100 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery aging by power FORMENTOR_AUX_BAT_AGE_POWConfirmed

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 168 to 175 of the reply, 8 bits.

0x56 = 86 → 86 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery current FORMENTOR_AUX_BAT_CConfirmed

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 16 to 47 of the reply, 32 bits. The value is signed.

0x0000139D = 5021 → (5021 ÷ 1000) = 5.021 A

Formula
(val ÷ 1000)
Range
-1000000 to 1000000 A
Unit
A

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery sensor temperature FORMENTOR_AUX_BAT_T_SConfirmed

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 72 to 79 of the reply, 8 bits.

0x43 = 67 → (67 − 40) = 27 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery soc FORMENTOR_AUX_BAT_SOCConfirmed

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 56 to 63 of the reply, 8 bits.

0x5A = 90 → 90 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery temperature FORMENTOR_AUX_BAT_TConfirmed

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 64 to 71 of the reply, 8 bits.

0x42 = 66 → (66 − 40) = 26 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery total charge FORMENTOR_AUX_BAT_CHRG_TOTConfirmed

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 96 to 127 of the reply, 32 bits.

0x00000B07 = 2823 → (2823 ÷ 10) = 282.3 Ah

Formula
(val ÷ 10)
Range
0 to 10000000 Ah
Unit
Ah

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery total discharge FORMENTOR_AUX_BAT_DSCH_TOTConfirmed

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 128 to 159 of the reply, 32 bits.

0x000009DE = 2526 → (2526 ÷ 10) = 252.6 Ah

Formula
(val ÷ 10)
Range
0 to 10000000 Ah
Unit
Ah

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

12V battery voltage FORMENTOR_AUX_BAT_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 2A F7
  • Service 22DID 2AF7
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

0x23A8 = 9128 → (9128 ÷ 1000 + 4) = 13.128 V

Formula
(val ÷ 1000 + 4)
Range
0 to 69 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

AC charging FORMENTOR_AC_CHARGINGConfirmed

  • Request22 74 48
  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

All-wheel drive voltage FORMENTOR_PQ35_HAL_VConfirmed

  • Request22 2B E9
  • Service 22DID 2BE9
  • Module70F → 779
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 10) = 0 V

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Aux. hydraulic pump voltage FORMENTOR_AUX_HYDRAULIC_PMP_V

  • Request22 51 A7
  • Service 22DID 51A7
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2020 to 2024, 2026. Not supported for 2025.

Battery acid stratification FORMENTOR_BAT_ACID

  • Request22 2A 1D
  • Service 22DID 2A1D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10 + 9)
Range
0 to 2559 %
Unit
%

In testing for 2020 to 2024, 2026. Not supported for 2025.

Battery cell soc max, ID FORMENTOR_HVBAT_CELL_SOC_MAX_IDConfirmed

  • Request22 1E 2C
  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery cell soc min, ID FORMENTOR_HVBAT_CELL_SOC_MIN_IDConfirmed

  • Request22 1E 2D
  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery cell soc, maximum FORMENTOR_HVBAT_CELL_SOC_MAXConfirmed

  • Request22 1E 2C
  • Service 22DID 1E2C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery cell soc, minimum FORMENTOR_HVBAT_CELL_SOC_MINConfirmed

  • Request22 1E 2D
  • Service 22DID 1E2D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery condition for display FORMENTOR_BAT_COND_DISPLAY

  • Request22 2A 0D
  • Service 22DID 2A0D
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 %
Unit
%

In testing for 2020 to 2024, 2026. Not supported for 2025.

Battery current filtered FORMENTOR_BAT_CURRENT_FILTERED

  • Request22 2A 08
  • Service 22DID 2A08
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
(val ÷ 1000 − 3000)
Range
-3000 to 13777 A
Unit
A

In testing for 2020 to 2024, 2026. Not supported for 2025.

Battery current limit, charging FORMENTOR_HVBAT_I_LIM_CHGConfirmed

  • Request22 1E 1B
  • Service 22DID 1E1B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 2621.4 A
Unit
A

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery current limit, discharging FORMENTOR_HVBAT_I_LIM_DSCHConfirmed

  • Request22 1E 1C
  • Service 22DID 1E1C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 2621.4 A
Unit
A

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery current, DC, alternate FORMENTOR_HVBAT_I_DC_2Confirmed

  • Request22 1E 3E
  • Service 22DID 1E3E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 100 − 1500)
Range
-1500 to 42948172.95 A
Unit
A

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery internal resistance FORMENTOR_BAT_INT_RConfirmed

  • Request22 2A 0E
  • Service 22DID 2A0E
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 20 ÷ 100) = 0

Formula
(val × 20 ÷ 100)
Range
0 to 51
Unit
Raw value

Confirmed for 2022 to 2024. In testing for 2020 to 2021. Not supported for 2025 to 2026.

Battery internal resistance, raw FORMENTOR_BAT_INTERNAL_RES_RAWConfirmed

  • Request22 2A 25
  • Service 22DID 2A25
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021, 2023 to 2026

Example reply from a 2022 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 5) = 0

Formula
(val ÷ 5)
Range
0 to 51
Unit
Raw value

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2024. Not supported for 2025 to 2026.

Battery temperature, max FORMENTOR_HVBAT_T_MAX_V2Confirmed

  • Request22 1E 0E
  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery temperature, max sensor ID FORMENTOR_HVBAT_T_MAX_IDConfirmed

  • Request22 1E 0E
  • Service 22DID 1E0E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery temperature, min FORMENTOR_HVBAT_T_MINConfirmed

  • Request22 1E 0F
  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery temperature, min sensor ID FORMENTOR_HVBAT_T_MIN_IDConfirmed

  • Request22 1E 0F
  • Service 22DID 1E0F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery voltage FORMENTOR_BATTERY_V_V2Confirmed

  • Request22 10 5A
  • Service 22DID 105A
  • ModuleFC00 → FE0076
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 20)
Range
-655360 to 655340 mV
Unit
mV

Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Battery voltage, before main switch FORMENTOR_HVBAT_V_BEFOREConfirmed

  • Request22 1E 36
  • Service 22DID 1E36
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 312499785 ÷ 10000000000)
Range
0 to 2047.967 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery voltage, charging FORMENTOR_HVBAT_V_CHGConfirmed

  • Request22 1E 39
  • Service 22DID 1E39
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 312499785 ÷ 10000000000)
Range
-1023.999 to 1023.967 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery voltage, sum of all cells FORMENTOR_HVBAT_V_CELLS_SUMConfirmed

  • Request22 1E 3C
  • Service 22DID 1E3C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val × 244140625 ÷ 1000000000)
Range
-524288 to 524287.99 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Charge air pressure FORMENTOR_PQ35_CHG_AIR_PConfirmed

  • Request22 22 11
  • Service 22DID 2211
  • Module714 → 77E
  • Every1 s
  • Testing for 2020 to 2021, 2024

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2022 to 2023, 2025 to 2026. In testing for 2020 to 2021, 2024.

Charge voltage, max FORMENTOR_MAXIMUM_CHARGE_VConfirmed

  • Request22 51 71
  • Service 22DID 5171
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Charging, rapid? FORMENTOR_RAPID_CHARGE_PORTConfirmed

  • Request22 74 48
  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2022. Supported for 2021, 2023 to 2026.

Current gear FORMENTOR_DRIVE_MODEConfirmed

  • Request22 74 48
  • Service 22DID 7448
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bit 7 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0STANDBYStandby
1DRIVINGDriving

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

DC battery voltage FORMENTOR_DC_BATTERY_VConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 1E 3B
  • Service 22DID 1E3B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

DC-DC converter current, alternate FORMENTOR_DCDC_I_ALTConfirmed

  • Request22 46 5B
  • Service 22DID 465B
  • ModuleFC00 → FE00B9
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 A
Unit
A

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

DC-DC converter, current FORMENTOR_DCDC_IConfirmed

  • Request22 2A 53
  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 8 to 23 of the reply, 16 bits.

0x0218 = 536 → (536 − 511) = 25 A

Formula
(val − 511)
Range
-511 to 65024 A
Unit
A

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

DC-DC converter, low voltage FORMENTOR_DCDC_V_LOWConfirmed

  • Request22 2A 53
  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

0x84 = 132 → (132 ÷ 10) = 13.2 V

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

DC-DC converter, reserved current FORMENTOR_DCDC_I_RSVConfirmed

  • Request22 2A 53
  • Service 22DID 2A53
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 24 to 39 of the reply, 16 bits.

0x02FE = 766 → (766 − 511) = 255 A

Formula
(val − 511)
Range
-511 to 65024 A
Unit
A

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

DC-DC voltage FORMENTOR_DC_DC_VConfirmed

  • Request22 46 5D
  • Service 22DID 465D
  • ModuleFC00 → FE00B9
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 512)
Range
0 to 127.9980469 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Discharge voltage, min FORMENTOR_MINIMUM_DISCHARGE_VConfirmed

  • Request22 51 70
  • Service 22DID 5170
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

ECall battery charge level FORMENTOR_ECALL_SOCConfirmed

  • Request22 08 38
  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing for 2020 to 2021, 2023

Example reply from a 2026 Cupra Formentor.

Bits 8 to 15 of the reply, 8 bits.

0x55 = 85 → 85 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2024 to 2026. In testing for 2020 to 2021. Not supported for 2023.

ECall battery status FORMENTOR_ECALL_STATUSConfirmed

  • Request22 08 38
  • Service 22DID 0838
  • Module767 → 7D1
  • Every5 s
  • Testing for 2020 to 2021, 2023

Example reply from a 2026 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

0x02 = 2 → NORMAL

Unit
Named states
States
Raw valueState
1CRITICAL
2NORMAL

Confirmed for 2022, 2024 to 2026. In testing for 2020 to 2021. Not supported for 2023.

Electric motor battery energy FORMENTOR_EM_HVBAT_E_INFO

  • Request22 15 D1
  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Bits 40 to 55 of the reply, 16 bits.

Formula
(val × 50 ÷ 1000)
Range
0 to 3276.75 kWh
Unit
kWh

In testing for 2020 to 2021. Supported for 2022 to 2026.

Estimated reserve range FORMENTOR_RANGE_EST_CANConfirmed

  • Request22 2A B5
  • Service 22DID 2AB5
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 32 to 47 of the reply, 16 bits.

0x0062 = 98 → 98 km

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

High-voltage battery current, raw count FORMENTOR_HVBAT_IConfirmed

  • Request22 1E 3D
  • Service 22DID 1E3D
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 31 of the reply, 32 bits.

0x00023609 = 144905 → 144,905

Formula
val
Range
0 to 4294967295
Unit
Number

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery capacity FORMENTOR_HVBAT_CAPConfirmed

Total possible energy in the high voltage battery

  • Request22 2A B2
  • Service 22DID 2AB2
  • Module710 → 77A
  • Every86400 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

0x0188 = 392 → (392 × 50) = 19,600 W

Formula
(val × 50)
Range
0 to 3276750 W
Unit
W

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

HV battery cell voltage max, ID FORMENTOR_HVBAT_CELL_V_MAX_IDConfirmed

  • Request22 1E 33
  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage min, ID FORMENTOR_HVBAT_CELL_V_MIN_IDConfirmed

  • Request22 1E 34
  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, maximum FORMENTOR_HVBAT_CELL_V_MAX_V2Confirmed

  • Request22 1E 33
  • Service 22DID 1E33
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2441 ÷ 10000)
Range
0 to 15.997 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, minimum FORMENTOR_HVBAT_CELL_V_MIN_V2Confirmed

  • Request22 1E 34
  • Service 22DID 1E34
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2441 ÷ 10000)
Range
0 to 15.997 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery charge FORMENTOR_HVBAT_SOC_V2Confirmed

Pelican can show this parameter as the state of charge.

  • Request22 02 8C
  • Service 22DID 028C
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 7 of the reply, 8 bits.

0xBE = 190 → (190 × 100 ÷ 255) = 74.509804 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery energy content FORMENTOR_HVBAT_E_CONTENTConfirmed

Energy stored in the high voltage battery

  • Request22 2A B8
  • Service 22DID 2AB8
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 16 to 31 of the reply, 16 bits.

0x0240 = 576 → (576 × 25 ÷ 1000) = 14.4 kWh

Formula
(val × 25 ÷ 1000)
Range
0 to 1638.37 kWh
Unit
kWh

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

HV battery health FORMENTOR_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Request22 51 E0
  • Service 22DID 51E0
  • Module7E5 → 7ED
  • Every30 s
  • Testing for 2020 to 2023, 2025 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.127 − 1798.574)
Range
-1798.574 to 6524 %
Unit
%

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery module temperature, #1 FORMENTOR_HVBAT_MOD_T_1Confirmed

  • Request22 1E AE
  • Service 22DID 1EAE
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8 − 40)
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery module temperature, #2 FORMENTOR_HVBAT_MOD_T_2Confirmed

  • Request22 1E AF
  • Service 22DID 1EAF
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8 − 40)
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery module temperature, #3 FORMENTOR_HVBAT_MOD_T_3Confirmed

  • Request22 1E B0
  • Service 22DID 1EB0
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8 − 40)
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery module temperature, #4 FORMENTOR_HVBAT_MOD_T_4Confirmed

  • Request22 1E B1
  • Service 22DID 1EB1
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8 − 40)
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery total ampere hours of charge FORMENTOR_HVBAT_TOT_AH_CHRGConfirmed

  • Request22 1E 32
  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 31 of the reply, 32 bits.

0x003B05DE = 3868126 → (3868126 ÷ 549.31642) = 7,041.708311 Ah

Formula
(val ÷ 549.31642)
Range
0 to 7818700 Ah
Unit
Ah

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery total ampere hours of discharge FORMENTOR_HVBAT_TOT_AH_DCHRGConfirmed

  • Request22 1E 32
  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 32 to 63 of the reply, 32 bits. The value is signed.

0xFFC64C49 = -3781559 → (-3781559 ÷ 549.31642) = -6,884.117901 Ah

Formula
(val ÷ 549.31642)
Range
-3909350 to 3909350 Ah
Unit
Ah

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery total kilowatt hours of charge FORMENTOR_HVBAT_TOT_KWH_CHRGConfirmed

  • Request22 1E 32
  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 64 to 95 of the reply, 32 bits.

0x01509CF2 = 22060274 → (22060274 ÷ 8583.07212) = 2,570.207228 kWh

Formula
(val ÷ 8583.07212)
Range
0 to 500300 kWh
Unit
kWh

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery total kilowatt hours of discharge FORMENTOR_HVBAT_TOT_KWH_DCHRGConfirmed

  • Request22 1E 32
  • Service 22DID 1E32
  • Module7E5 → 7ED
  • Every5 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 96 to 127 of the reply, 32 bits. The value is signed.

0xFEC205D0 = -20838960 → (-20838960 ÷ 8583.07212) = -2,427.913888 kWh

Formula
(val ÷ 8583.07212)
Range
-250199 to 250199 kWh
Unit
kWh

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery voltage FORMENTOR_HVBAT_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Request22 1E 3B
  • Service 22DID 1E3B
  • Module7E5 → 7ED
  • Every1 s
  • Testing for 2020 to 2023, 2025 to 2026

Example reply from a 2024 Cupra Formentor.

Bits 0 to 15 of the reply, 16 bits.

0x05BC = 1468 → (1468 ÷ 4) = 367 V

Formula
(val ÷ 4)
Range
0 to 1000 V
Unit
V

Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.

HV battery: circulation pump flow FORMENTOR_CIRC_PUMP_FLOWConfirmed

  • Request22 74 3B
  • Service 22DID 743B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Non-vehicle energy requirement FORMENTOR_NV_ENERGY_REQUIREMENT

  • Request22 15 D1
  • Service 22DID 15D1
  • Module710 → 77A
  • Every5 s
  • Testing for 2020 to 2021

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 50 ÷ 1000)
Range
0 to 12.75 kWh
Unit
kWh

In testing for 2020 to 2021. Supported for 2022 to 2026.

State of charge FORMENTOR_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 02 8C
  • Service 22DID 028C
  • ModuleFC00 → FE007B
  • Every250 ms
  • Testing for 2020 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 250)
Range
0 to 100 %
Unit
%

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Temperature, battery FORMENTOR_BATTERY_TConfirmed

  • Request22 2A 0B
  • Service 22DID 2A0B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery › Cells

HV battery cell voltage, #1 FORMENTOR_HVBAT_CELL_V_001Confirmed

  • Request22 1E 40
  • Service 22DID 1E40
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #2 FORMENTOR_HVBAT_CELL_V_002Confirmed

  • Request22 1E 41
  • Service 22DID 1E41
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #3 FORMENTOR_HVBAT_CELL_V_003Confirmed

  • Request22 1E 42
  • Service 22DID 1E42
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #4 FORMENTOR_HVBAT_CELL_V_004Confirmed

  • Request22 1E 43
  • Service 22DID 1E43
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #5 FORMENTOR_HVBAT_CELL_V_005Confirmed

  • Request22 1E 44
  • Service 22DID 1E44
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #6 FORMENTOR_HVBAT_CELL_V_006Confirmed

  • Request22 1E 45
  • Service 22DID 1E45
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #7 FORMENTOR_HVBAT_CELL_V_007Confirmed

  • Request22 1E 46
  • Service 22DID 1E46
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #8 FORMENTOR_HVBAT_CELL_V_008Confirmed

  • Request22 1E 47
  • Service 22DID 1E47
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #9 FORMENTOR_HVBAT_CELL_V_009Confirmed

  • Request22 1E 48
  • Service 22DID 1E48
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #10 FORMENTOR_HVBAT_CELL_V_010Confirmed

  • Request22 1E 49
  • Service 22DID 1E49
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #11 FORMENTOR_HVBAT_CELL_V_011Confirmed

  • Request22 1E 4A
  • Service 22DID 1E4A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #12 FORMENTOR_HVBAT_CELL_V_012Confirmed

  • Request22 1E 4B
  • Service 22DID 1E4B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #13 FORMENTOR_HVBAT_CELL_V_013Confirmed

  • Request22 1E 4C
  • Service 22DID 1E4C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #14 FORMENTOR_HVBAT_CELL_V_014Confirmed

  • Request22 1E 4D
  • Service 22DID 1E4D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #15 FORMENTOR_HVBAT_CELL_V_015Confirmed

  • Request22 1E 4E
  • Service 22DID 1E4E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #16 FORMENTOR_HVBAT_CELL_V_016Confirmed

  • Request22 1E 4F
  • Service 22DID 1E4F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #17 FORMENTOR_HVBAT_CELL_V_017Confirmed

  • Request22 1E 50
  • Service 22DID 1E50
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #18 FORMENTOR_HVBAT_CELL_V_018Confirmed

  • Request22 1E 51
  • Service 22DID 1E51
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #19 FORMENTOR_HVBAT_CELL_V_019Confirmed

  • Request22 1E 52
  • Service 22DID 1E52
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #20 FORMENTOR_HVBAT_CELL_V_020Confirmed

  • Request22 1E 53
  • Service 22DID 1E53
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #21 FORMENTOR_HVBAT_CELL_V_021Confirmed

  • Request22 1E 54
  • Service 22DID 1E54
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #22 FORMENTOR_HVBAT_CELL_V_022Confirmed

  • Request22 1E 55
  • Service 22DID 1E55
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #23 FORMENTOR_HVBAT_CELL_V_023Confirmed

  • Request22 1E 56
  • Service 22DID 1E56
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #24 FORMENTOR_HVBAT_CELL_V_024Confirmed

  • Request22 1E 57
  • Service 22DID 1E57
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #25 FORMENTOR_HVBAT_CELL_V_025Confirmed

  • Request22 1E 58
  • Service 22DID 1E58
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #26 FORMENTOR_HVBAT_CELL_V_026Confirmed

  • Request22 1E 59
  • Service 22DID 1E59
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #27 FORMENTOR_HVBAT_CELL_V_027Confirmed

  • Request22 1E 5A
  • Service 22DID 1E5A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #28 FORMENTOR_HVBAT_CELL_V_028Confirmed

  • Request22 1E 5B
  • Service 22DID 1E5B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #29 FORMENTOR_HVBAT_CELL_V_029Confirmed

  • Request22 1E 5C
  • Service 22DID 1E5C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #30 FORMENTOR_HVBAT_CELL_V_030Confirmed

  • Request22 1E 5D
  • Service 22DID 1E5D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #31 FORMENTOR_HVBAT_CELL_V_031Confirmed

  • Request22 1E 5E
  • Service 22DID 1E5E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #32 FORMENTOR_HVBAT_CELL_V_032Confirmed

  • Request22 1E 5F
  • Service 22DID 1E5F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #33 FORMENTOR_HVBAT_CELL_V_033Confirmed

  • Request22 1E 60
  • Service 22DID 1E60
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #34 FORMENTOR_HVBAT_CELL_V_034Confirmed

  • Request22 1E 61
  • Service 22DID 1E61
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #35 FORMENTOR_HVBAT_CELL_V_035Confirmed

  • Request22 1E 62
  • Service 22DID 1E62
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #36 FORMENTOR_HVBAT_CELL_V_036Confirmed

  • Request22 1E 63
  • Service 22DID 1E63
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #37 FORMENTOR_HVBAT_CELL_V_037Confirmed

  • Request22 1E 64
  • Service 22DID 1E64
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #38 FORMENTOR_HVBAT_CELL_V_038Confirmed

  • Request22 1E 65
  • Service 22DID 1E65
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #39 FORMENTOR_HVBAT_CELL_V_039Confirmed

  • Request22 1E 66
  • Service 22DID 1E66
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #40 FORMENTOR_HVBAT_CELL_V_040Confirmed

  • Request22 1E 67
  • Service 22DID 1E67
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #41 FORMENTOR_HVBAT_CELL_V_041Confirmed

  • Request22 1E 68
  • Service 22DID 1E68
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #42 FORMENTOR_HVBAT_CELL_V_042Confirmed

  • Request22 1E 69
  • Service 22DID 1E69
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #43 FORMENTOR_HVBAT_CELL_V_043Confirmed

  • Request22 1E 6A
  • Service 22DID 1E6A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #44 FORMENTOR_HVBAT_CELL_V_044Confirmed

  • Request22 1E 6B
  • Service 22DID 1E6B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #45 FORMENTOR_HVBAT_CELL_V_045Confirmed

  • Request22 1E 6C
  • Service 22DID 1E6C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #46 FORMENTOR_HVBAT_CELL_V_046Confirmed

  • Request22 1E 6D
  • Service 22DID 1E6D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #47 FORMENTOR_HVBAT_CELL_V_047Confirmed

  • Request22 1E 6E
  • Service 22DID 1E6E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #48 FORMENTOR_HVBAT_CELL_V_048Confirmed

  • Request22 1E 6F
  • Service 22DID 1E6F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #49 FORMENTOR_HVBAT_CELL_V_049Confirmed

  • Request22 1E 70
  • Service 22DID 1E70
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #50 FORMENTOR_HVBAT_CELL_V_050Confirmed

  • Request22 1E 71
  • Service 22DID 1E71
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #51 FORMENTOR_HVBAT_CELL_V_051Confirmed

  • Request22 1E 72
  • Service 22DID 1E72
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #52 FORMENTOR_HVBAT_CELL_V_052Confirmed

  • Request22 1E 73
  • Service 22DID 1E73
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #53 FORMENTOR_HVBAT_CELL_V_053Confirmed

  • Request22 1E 74
  • Service 22DID 1E74
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #54 FORMENTOR_HVBAT_CELL_V_054Confirmed

  • Request22 1E 75
  • Service 22DID 1E75
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #55 FORMENTOR_HVBAT_CELL_V_055Confirmed

  • Request22 1E 76
  • Service 22DID 1E76
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #56 FORMENTOR_HVBAT_CELL_V_056Confirmed

  • Request22 1E 77
  • Service 22DID 1E77
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #57 FORMENTOR_HVBAT_CELL_V_057Confirmed

  • Request22 1E 78
  • Service 22DID 1E78
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #58 FORMENTOR_HVBAT_CELL_V_058Confirmed

  • Request22 1E 79
  • Service 22DID 1E79
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #59 FORMENTOR_HVBAT_CELL_V_059Confirmed

  • Request22 1E 7A
  • Service 22DID 1E7A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #60 FORMENTOR_HVBAT_CELL_V_060Confirmed

  • Request22 1E 7B
  • Service 22DID 1E7B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #61 FORMENTOR_HVBAT_CELL_V_061Confirmed

  • Request22 1E 7C
  • Service 22DID 1E7C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #62 FORMENTOR_HVBAT_CELL_V_062Confirmed

  • Request22 1E 7D
  • Service 22DID 1E7D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #63 FORMENTOR_HVBAT_CELL_V_063Confirmed

  • Request22 1E 7E
  • Service 22DID 1E7E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #64 FORMENTOR_HVBAT_CELL_V_064Confirmed

  • Request22 1E 7F
  • Service 22DID 1E7F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #65 FORMENTOR_HVBAT_CELL_V_065Confirmed

  • Request22 1E 80
  • Service 22DID 1E80
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #66 FORMENTOR_HVBAT_CELL_V_066Confirmed

  • Request22 1E 81
  • Service 22DID 1E81
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #67 FORMENTOR_HVBAT_CELL_V_067Confirmed

  • Request22 1E 82
  • Service 22DID 1E82
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #68 FORMENTOR_HVBAT_CELL_V_068Confirmed

  • Request22 1E 83
  • Service 22DID 1E83
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #69 FORMENTOR_HVBAT_CELL_V_069Confirmed

  • Request22 1E 84
  • Service 22DID 1E84
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #70 FORMENTOR_HVBAT_CELL_V_070Confirmed

  • Request22 1E 85
  • Service 22DID 1E85
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #71 FORMENTOR_HVBAT_CELL_V_071Confirmed

  • Request22 1E 86
  • Service 22DID 1E86
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #72 FORMENTOR_HVBAT_CELL_V_072Confirmed

  • Request22 1E 87
  • Service 22DID 1E87
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #73 FORMENTOR_HVBAT_CELL_V_073Confirmed

  • Request22 1E 88
  • Service 22DID 1E88
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #74 FORMENTOR_HVBAT_CELL_V_074Confirmed

  • Request22 1E 89
  • Service 22DID 1E89
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #75 FORMENTOR_HVBAT_CELL_V_075Confirmed

  • Request22 1E 8A
  • Service 22DID 1E8A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #76 FORMENTOR_HVBAT_CELL_V_076Confirmed

  • Request22 1E 8B
  • Service 22DID 1E8B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #77 FORMENTOR_HVBAT_CELL_V_077Confirmed

  • Request22 1E 8C
  • Service 22DID 1E8C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #78 FORMENTOR_HVBAT_CELL_V_078Confirmed

  • Request22 1E 8D
  • Service 22DID 1E8D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #79 FORMENTOR_HVBAT_CELL_V_079Confirmed

  • Request22 1E 8E
  • Service 22DID 1E8E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #80 FORMENTOR_HVBAT_CELL_V_080Confirmed

  • Request22 1E 8F
  • Service 22DID 1E8F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #81 FORMENTOR_HVBAT_CELL_V_081Confirmed

  • Request22 1E 90
  • Service 22DID 1E90
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #82 FORMENTOR_HVBAT_CELL_V_082Confirmed

  • Request22 1E 91
  • Service 22DID 1E91
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #83 FORMENTOR_HVBAT_CELL_V_083Confirmed

  • Request22 1E 92
  • Service 22DID 1E92
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #84 FORMENTOR_HVBAT_CELL_V_084Confirmed

  • Request22 1E 93
  • Service 22DID 1E93
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #85 FORMENTOR_HVBAT_CELL_V_085Confirmed

  • Request22 1E 94
  • Service 22DID 1E94
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #86 FORMENTOR_HVBAT_CELL_V_086Confirmed

  • Request22 1E 95
  • Service 22DID 1E95
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #87 FORMENTOR_HVBAT_CELL_V_087Confirmed

  • Request22 1E 96
  • Service 22DID 1E96
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #88 FORMENTOR_HVBAT_CELL_V_088Confirmed

  • Request22 1E 97
  • Service 22DID 1E97
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #89 FORMENTOR_HVBAT_CELL_V_089Confirmed

  • Request22 1E 98
  • Service 22DID 1E98
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #90 FORMENTOR_HVBAT_CELL_V_090Confirmed

  • Request22 1E 99
  • Service 22DID 1E99
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #91 FORMENTOR_HVBAT_CELL_V_091Confirmed

  • Request22 1E 9A
  • Service 22DID 1E9A
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #92 FORMENTOR_HVBAT_CELL_V_092Confirmed

  • Request22 1E 9B
  • Service 22DID 1E9B
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #93 FORMENTOR_HVBAT_CELL_V_093Confirmed

  • Request22 1E 9C
  • Service 22DID 1E9C
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #94 FORMENTOR_HVBAT_CELL_V_094Confirmed

  • Request22 1E 9D
  • Service 22DID 1E9D
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #95 FORMENTOR_HVBAT_CELL_V_095Confirmed

  • Request22 1E 9E
  • Service 22DID 1E9E
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery cell voltage, #96 FORMENTOR_HVBAT_CELL_V_096Confirmed

  • Request22 1E 9F
  • Service 22DID 1E9F
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000 + 1)
Range
3 to 4.5 V
Unit
V

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Battery › Internal

Average battery consumption FORMENTOR_HVBAT_CSMP_AVG_INTConfirmed

  • Request22 2A B4
  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 72 to 79 of the reply, 8 bits.

0x14 = 20 → 20 A

Formula
val
Range
0 to 255 A
Unit
A

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Estimated electric power reserve FORMENTOR_RANGE_EST_INTConfirmed

  • Request22 2A B4
  • Service 22DID 2AB4
  • Module710 → 77A
  • Every1 s
  • Testing for 2020 to 2021

Example reply from a 2026 Cupra Formentor.

Bits 16 to 31 of the reply, 16 bits.

0x0062 = 98 → 98 km

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2022 to 2026. In testing for 2020 to 2021.

Battery › Modules

HV battery module temperature, #5 FORMENTOR_HVBAT_MOD_T_5Confirmed

  • Request22 1E B2
  • Service 22DID 1EB2
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8 − 40)
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery module temperature, #6 FORMENTOR_HVBAT_MOD_T_6Confirmed

  • Request22 1E B3
  • Service 22DID 1EB3
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8 − 40)
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery module temperature, #7 FORMENTOR_HVBAT_MOD_T_7Confirmed

  • Request22 1E B4
  • Service 22DID 1EB4
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8 − 40)
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

HV battery module temperature, #8 FORMENTOR_HVBAT_MOD_T_8Confirmed

  • Request22 1E B5
  • Service 22DID 1EB5
  • ModuleFC00 → FE007B
  • Every1 s
  • Testing for 2020 to 2024, 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8 − 40)
Range
-40 to 8151.875 °C
Unit
°C

Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.