Battery parameters
The Cupra Formentor has 173 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery adapted capacity FORMENTOR_AUX_BAT_CAPConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 176 to 183 of the reply, 8 bits.
0x3B = 59 → 59 Ah
- Formula
val- Range
- 0 to 100 Ah
- Unit
- Ah
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
12V battery aging by capacity FORMENTOR_AUX_BAT_AGE_CAPConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 160 to 167 of the reply, 8 bits.
0x64 = 100 → 100 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
12V battery aging by power FORMENTOR_AUX_BAT_AGE_POWConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 168 to 175 of the reply, 8 bits.
0x56 = 86 → 86 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
12V battery current FORMENTOR_AUX_BAT_CConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 16 to 47 of the reply, 32 bits. The value is signed.
0x0000139D = 5021 → (5021 ÷ 1000) = 5.021 A
- Formula
(val ÷ 1000)- Range
- -1000000 to 1000000 A
- Unit
- A
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
12V battery sensor temperature FORMENTOR_AUX_BAT_T_SConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 72 to 79 of the reply, 8 bits.
0x43 = 67 → (67 − 40) = 27 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
12V battery soc FORMENTOR_AUX_BAT_SOCConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 56 to 63 of the reply, 8 bits.
0x5A = 90 → 90 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
12V battery temperature FORMENTOR_AUX_BAT_TConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 64 to 71 of the reply, 8 bits.
0x42 = 66 → (66 − 40) = 26 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
12V battery total charge FORMENTOR_AUX_BAT_CHRG_TOTConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 96 to 127 of the reply, 32 bits.
0x00000B07 = 2823 → (2823 ÷ 10) = 282.3 Ah
- Formula
(val ÷ 10)- Range
- 0 to 10000000 Ah
- Unit
- Ah
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
12V battery total discharge FORMENTOR_AUX_BAT_DSCH_TOTConfirmed
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 128 to 159 of the reply, 32 bits.
0x000009DE = 2526 → (2526 ÷ 10) = 252.6 Ah
- Formula
(val ÷ 10)- Range
- 0 to 10000000 Ah
- Unit
- Ah
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
12V battery voltage FORMENTOR_AUX_BAT_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 2A F7 - Service 22
DID 2AF7 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 0 to 15 of the reply, 16 bits.
0x23A8 = 9128 → (9128 ÷ 1000 + 4) = 13.128 V
- Formula
(val ÷ 1000 + 4)- Range
- 0 to 69 V
- Unit
- V
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
AC charging FORMENTOR_AC_CHARGINGConfirmed
- Request
22 74 48 - Service 22
DID 7448 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
All-wheel drive voltage FORMENTOR_PQ35_HAL_VConfirmed
- Request
22 2B E9 - Service 22
DID 2BE9 - Module
70F → 779 - Every
1 s - Testing for 2020 to 2022, 2024 to 2026
Example reply from a 2023 Cupra Formentor.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 10) = 0 V
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.
Aux. hydraulic pump voltage FORMENTOR_AUX_HYDRAULIC_PMP_V
- Request
22 51 A7 - Service 22
DID 51A7 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2020 to 2024, 2026. Not supported for 2025.
Battery acid stratification FORMENTOR_BAT_ACID
- Request
22 2A 1D - Service 22
DID 2A1D - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10 + 9)- Range
- 0 to 2559 %
- Unit
- %
In testing for 2020 to 2024, 2026. Not supported for 2025.
Battery cell soc max, ID FORMENTOR_HVBAT_CELL_SOC_MAX_IDConfirmed
- Request
22 1E 2C - Service 22
DID 1E2C - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery cell soc min, ID FORMENTOR_HVBAT_CELL_SOC_MIN_IDConfirmed
- Request
22 1E 2D - Service 22
DID 1E2D - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery cell soc, maximum FORMENTOR_HVBAT_CELL_SOC_MAXConfirmed
- Request
22 1E 2C - Service 22
DID 1E2C - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery cell soc, minimum FORMENTOR_HVBAT_CELL_SOC_MINConfirmed
- Request
22 1E 2D - Service 22
DID 1E2D - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery condition for display FORMENTOR_BAT_COND_DISPLAY
- Request
22 2A 0D - Service 22
DID 2A0D - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 %
- Unit
- %
In testing for 2020 to 2024, 2026. Not supported for 2025.
Battery current filtered FORMENTOR_BAT_CURRENT_FILTERED
- Request
22 2A 08 - Service 22
DID 2A08 - Module
710 → 77A - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 1000 − 3000)- Range
- -3000 to 13777 A
- Unit
- A
In testing for 2020 to 2024, 2026. Not supported for 2025.
Battery current limit, charging FORMENTOR_HVBAT_I_LIM_CHGConfirmed
- Request
22 1E 1B - Service 22
DID 1E1B - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 2621.4 A
- Unit
- A
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery current limit, discharging FORMENTOR_HVBAT_I_LIM_DSCHConfirmed
- Request
22 1E 1C - Service 22
DID 1E1C - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 2621.4 A
- Unit
- A
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery current, DC, alternate FORMENTOR_HVBAT_I_DC_2Confirmed
- Request
22 1E 3E - Service 22
DID 1E3E - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 100 − 1500)- Range
- -1500 to 42948172.95 A
- Unit
- A
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery internal resistance FORMENTOR_BAT_INT_RConfirmed
- Request
22 2A 0E - Service 22
DID 2A0E - Module
710 → 77A - Every
5 s - Testing for 2020 to 2021, 2025 to 2026
Example reply from a 2024 Cupra Formentor.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 20 ÷ 100) = 0
- Formula
(val × 20 ÷ 100)- Range
- 0 to 51
- Unit
- Raw value
Confirmed for 2022 to 2024. In testing for 2020 to 2021. Not supported for 2025 to 2026.
Battery internal resistance, raw FORMENTOR_BAT_INTERNAL_RES_RAWConfirmed
- Request
22 2A 25 - Service 22
DID 2A25 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021, 2023 to 2026
Example reply from a 2022 Cupra Formentor.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 5) = 0
- Formula
(val ÷ 5)- Range
- 0 to 51
- Unit
- Raw value
Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2024. Not supported for 2025 to 2026.
Battery temperature, max FORMENTOR_HVBAT_T_MAX_V2Confirmed
- Request
22 1E 0E - Service 22
DID 1E0E - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery temperature, max sensor ID FORMENTOR_HVBAT_T_MAX_IDConfirmed
- Request
22 1E 0E - Service 22
DID 1E0E - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery temperature, min FORMENTOR_HVBAT_T_MINConfirmed
- Request
22 1E 0F - Service 22
DID 1E0F - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery temperature, min sensor ID FORMENTOR_HVBAT_T_MIN_IDConfirmed
- Request
22 1E 0F - Service 22
DID 1E0F - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery voltage FORMENTOR_BATTERY_V_V2Confirmed
- Request
22 10 5A - Service 22
DID 105A - Module
FC00 → FE0076 - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 20)- Range
- -655360 to 655340 mV
- Unit
- mV
Confirmed for 2025. In testing for 2020 to 2021, 2023 to 2024, 2026. Not supported for 2022.
Battery voltage, before main switch FORMENTOR_HVBAT_V_BEFOREConfirmed
- Request
22 1E 36 - Service 22
DID 1E36 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 312499785 ÷ 10000000000)- Range
- 0 to 2047.967 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery voltage, charging FORMENTOR_HVBAT_V_CHGConfirmed
- Request
22 1E 39 - Service 22
DID 1E39 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 312499785 ÷ 10000000000)- Range
- -1023.999 to 1023.967 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery voltage, sum of all cells FORMENTOR_HVBAT_V_CELLS_SUMConfirmed
- Request
22 1E 3C - Service 22
DID 1E3C - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val × 244140625 ÷ 1000000000)- Range
- -524288 to 524287.99 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Charge air pressure FORMENTOR_PQ35_CHG_AIR_PConfirmed
- Request
22 22 11 - Service 22
DID 2211 - Module
714 → 77E - Every
1 s - Testing for 2020 to 2021, 2024
Example reply from a 2026 Cupra Formentor.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 100 ÷ 255) = 0 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023, 2025 to 2026. In testing for 2020 to 2021, 2024.
Charge voltage, max FORMENTOR_MAXIMUM_CHARGE_VConfirmed
- Request
22 51 71 - Service 22
DID 5171 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Charging, rapid? FORMENTOR_RAPID_CHARGE_PORTConfirmed
- Request
22 74 48 - Service 22
DID 7448 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2022. Supported for 2021, 2023 to 2026.
Current gear FORMENTOR_DRIVE_MODEConfirmed
- Request
22 74 48 - Service 22
DID 7448 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bit 7 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | STANDBY | Standby |
1 | DRIVING | Driving |
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
DC battery voltage FORMENTOR_DC_BATTERY_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 1E 3B - Service 22
DID 1E3B - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
DC-DC converter current, alternate FORMENTOR_DCDC_I_ALTConfirmed
- Request
22 46 5B - Service 22
DID 465B - Module
FC00 → FE00B9 - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 A
- Unit
- A
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
DC-DC converter, current FORMENTOR_DCDC_IConfirmed
- Request
22 2A 53 - Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 8 to 23 of the reply, 16 bits.
0x0218 = 536 → (536 − 511) = 25 A
- Formula
(val − 511)- Range
- -511 to 65024 A
- Unit
- A
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
DC-DC converter, low voltage FORMENTOR_DCDC_V_LOWConfirmed
- Request
22 2A 53 - Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 0 to 7 of the reply, 8 bits.
0x84 = 132 → (132 ÷ 10) = 13.2 V
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
DC-DC converter, reserved current FORMENTOR_DCDC_I_RSVConfirmed
- Request
22 2A 53 - Service 22
DID 2A53 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 24 to 39 of the reply, 16 bits.
0x02FE = 766 → (766 − 511) = 255 A
- Formula
(val − 511)- Range
- -511 to 65024 A
- Unit
- A
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
DC-DC voltage FORMENTOR_DC_DC_VConfirmed
- Request
22 46 5D - Service 22
DID 465D - Module
FC00 → FE00B9 - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.9980469 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Discharge voltage, min FORMENTOR_MINIMUM_DISCHARGE_VConfirmed
- Request
22 51 70 - Service 22
DID 5170 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
ECall battery charge level FORMENTOR_ECALL_SOCConfirmed
- Request
22 08 38 - Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing for 2020 to 2021, 2023
Example reply from a 2026 Cupra Formentor.
Bits 8 to 15 of the reply, 8 bits.
0x55 = 85 → 85 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022, 2024 to 2026. In testing for 2020 to 2021. Not supported for 2023.
ECall battery status FORMENTOR_ECALL_STATUSConfirmed
- Request
22 08 38 - Service 22
DID 0838 - Module
767 → 7D1 - Every
5 s - Testing for 2020 to 2021, 2023
Example reply from a 2026 Cupra Formentor.
Bits 0 to 7 of the reply, 8 bits.
0x02 = 2 → NORMAL
- Unit
- Named states
| Raw value | State |
|---|---|
1 | CRITICAL |
2 | NORMAL |
Confirmed for 2022, 2024 to 2026. In testing for 2020 to 2021. Not supported for 2023.
Electric motor battery energy FORMENTOR_EM_HVBAT_E_INFO
- Request
22 15 D1 - Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing for 2020 to 2021
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val × 50 ÷ 1000)- Range
- 0 to 3276.75 kWh
- Unit
- kWh
In testing for 2020 to 2021. Supported for 2022 to 2026.
Estimated reserve range FORMENTOR_RANGE_EST_CANConfirmed
- Request
22 2A B5 - Service 22
DID 2AB5 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 32 to 47 of the reply, 16 bits.
0x0062 = 98 → 98 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
High-voltage battery current, raw count FORMENTOR_HVBAT_IConfirmed
- Request
22 1E 3D - Service 22
DID 1E3D - Module
7E5 → 7ED - Every
5 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 Cupra Formentor.
Bits 0 to 31 of the reply, 32 bits.
0x00023609 = 144905 → 144,905
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.
HV battery capacity FORMENTOR_HVBAT_CAPConfirmed
Total possible energy in the high voltage battery
- Request
22 2A B2 - Service 22
DID 2AB2 - Module
710 → 77A - Every
86400 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 0 to 15 of the reply, 16 bits.
0x0188 = 392 → (392 × 50) = 19,600 W
- Formula
(val × 50)- Range
- 0 to 3276750 W
- Unit
- W
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
HV battery cell voltage max, ID FORMENTOR_HVBAT_CELL_V_MAX_IDConfirmed
- Request
22 1E 33 - Service 22
DID 1E33 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage min, ID FORMENTOR_HVBAT_CELL_V_MIN_IDConfirmed
- Request
22 1E 34 - Service 22
DID 1E34 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, maximum FORMENTOR_HVBAT_CELL_V_MAX_V2Confirmed
- Request
22 1E 33 - Service 22
DID 1E33 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2441 ÷ 10000)- Range
- 0 to 15.997 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, minimum FORMENTOR_HVBAT_CELL_V_MIN_V2Confirmed
- Request
22 1E 34 - Service 22
DID 1E34 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2441 ÷ 10000)- Range
- 0 to 15.997 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery charge FORMENTOR_HVBAT_SOC_V2Confirmed
Pelican can show this parameter as the state of charge.
- Request
22 02 8C - Service 22
DID 028C - Module
7E5 → 7ED - Every
1 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 Cupra Formentor.
Bits 0 to 7 of the reply, 8 bits.
0xBE = 190 → (190 × 100 ÷ 255) = 74.509804 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.
HV battery energy content FORMENTOR_HVBAT_E_CONTENTConfirmed
Energy stored in the high voltage battery
- Request
22 2A B8 - Service 22
DID 2AB8 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 16 to 31 of the reply, 16 bits.
0x0240 = 576 → (576 × 25 ÷ 1000) = 14.4 kWh
- Formula
(val × 25 ÷ 1000)- Range
- 0 to 1638.37 kWh
- Unit
- kWh
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
HV battery health FORMENTOR_HVBAT_SOHConfirmed
Pelican can show this parameter as the state of health.
- Request
22 51 E0 - Service 22
DID 51E0 - Module
7E5 → 7ED - Every
30 s - Testing for 2020 to 2023, 2025 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.127 − 1798.574)- Range
- -1798.574 to 6524 %
- Unit
- %
Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.
HV battery module temperature, #1 FORMENTOR_HVBAT_MOD_T_1Confirmed
- Request
22 1E AE - Service 22
DID 1EAE - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery module temperature, #2 FORMENTOR_HVBAT_MOD_T_2Confirmed
- Request
22 1E AF - Service 22
DID 1EAF - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery module temperature, #3 FORMENTOR_HVBAT_MOD_T_3Confirmed
- Request
22 1E B0 - Service 22
DID 1EB0 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery module temperature, #4 FORMENTOR_HVBAT_MOD_T_4Confirmed
- Request
22 1E B1 - Service 22
DID 1EB1 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery total ampere hours of charge FORMENTOR_HVBAT_TOT_AH_CHRGConfirmed
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
5 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 Cupra Formentor.
Bits 0 to 31 of the reply, 32 bits.
0x003B05DE = 3868126 → (3868126 ÷ 549.31642) = 7,041.708311 Ah
- Formula
(val ÷ 549.31642)- Range
- 0 to 7818700 Ah
- Unit
- Ah
Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.
HV battery total ampere hours of discharge FORMENTOR_HVBAT_TOT_AH_DCHRGConfirmed
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
5 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 Cupra Formentor.
Bits 32 to 63 of the reply, 32 bits. The value is signed.
0xFFC64C49 = -3781559 → (-3781559 ÷ 549.31642) = -6,884.117901 Ah
- Formula
(val ÷ 549.31642)- Range
- -3909350 to 3909350 Ah
- Unit
- Ah
Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.
HV battery total kilowatt hours of charge FORMENTOR_HVBAT_TOT_KWH_CHRGConfirmed
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
5 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 Cupra Formentor.
Bits 64 to 95 of the reply, 32 bits.
0x01509CF2 = 22060274 → (22060274 ÷ 8583.07212) = 2,570.207228 kWh
- Formula
(val ÷ 8583.07212)- Range
- 0 to 500300 kWh
- Unit
- kWh
Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.
HV battery total kilowatt hours of discharge FORMENTOR_HVBAT_TOT_KWH_DCHRGConfirmed
- Request
22 1E 32 - Service 22
DID 1E32 - Module
7E5 → 7ED - Every
5 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 Cupra Formentor.
Bits 96 to 127 of the reply, 32 bits. The value is signed.
0xFEC205D0 = -20838960 → (-20838960 ÷ 8583.07212) = -2,427.913888 kWh
- Formula
(val ÷ 8583.07212)- Range
- -250199 to 250199 kWh
- Unit
- kWh
Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.
HV battery voltage FORMENTOR_HVBAT_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Request
22 1E 3B - Service 22
DID 1E3B - Module
7E5 → 7ED - Every
1 s - Testing for 2020 to 2023, 2025 to 2026
Example reply from a 2024 Cupra Formentor.
Bits 0 to 15 of the reply, 16 bits.
0x05BC = 1468 → (1468 ÷ 4) = 367 V
- Formula
(val ÷ 4)- Range
- 0 to 1000 V
- Unit
- V
Confirmed for 2024. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2025.
HV battery: circulation pump flow FORMENTOR_CIRC_PUMP_FLOWConfirmed
- Request
22 74 3B - Service 22
DID 743B - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Non-vehicle energy requirement FORMENTOR_NV_ENERGY_REQUIREMENT
- Request
22 15 D1 - Service 22
DID 15D1 - Module
710 → 77A - Every
5 s - Testing for 2020 to 2021
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 50 ÷ 1000)- Range
- 0 to 12.75 kWh
- Unit
- kWh
In testing for 2020 to 2021. Supported for 2022 to 2026.
State of charge FORMENTOR_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 02 8C - Service 22
DID 028C - Module
FC00 → FE007B - Every
250 ms - Testing for 2020 to 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 250)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Temperature, battery FORMENTOR_BATTERY_TConfirmed
- Request
22 2A 0B - Service 22
DID 2A0B - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery › Cells
HV battery cell voltage, #1 FORMENTOR_HVBAT_CELL_V_001Confirmed
- Request
22 1E 40 - Service 22
DID 1E40 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #2 FORMENTOR_HVBAT_CELL_V_002Confirmed
- Request
22 1E 41 - Service 22
DID 1E41 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #3 FORMENTOR_HVBAT_CELL_V_003Confirmed
- Request
22 1E 42 - Service 22
DID 1E42 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #4 FORMENTOR_HVBAT_CELL_V_004Confirmed
- Request
22 1E 43 - Service 22
DID 1E43 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #5 FORMENTOR_HVBAT_CELL_V_005Confirmed
- Request
22 1E 44 - Service 22
DID 1E44 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #6 FORMENTOR_HVBAT_CELL_V_006Confirmed
- Request
22 1E 45 - Service 22
DID 1E45 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #7 FORMENTOR_HVBAT_CELL_V_007Confirmed
- Request
22 1E 46 - Service 22
DID 1E46 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #8 FORMENTOR_HVBAT_CELL_V_008Confirmed
- Request
22 1E 47 - Service 22
DID 1E47 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #9 FORMENTOR_HVBAT_CELL_V_009Confirmed
- Request
22 1E 48 - Service 22
DID 1E48 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #10 FORMENTOR_HVBAT_CELL_V_010Confirmed
- Request
22 1E 49 - Service 22
DID 1E49 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #11 FORMENTOR_HVBAT_CELL_V_011Confirmed
- Request
22 1E 4A - Service 22
DID 1E4A - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #12 FORMENTOR_HVBAT_CELL_V_012Confirmed
- Request
22 1E 4B - Service 22
DID 1E4B - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #13 FORMENTOR_HVBAT_CELL_V_013Confirmed
- Request
22 1E 4C - Service 22
DID 1E4C - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #14 FORMENTOR_HVBAT_CELL_V_014Confirmed
- Request
22 1E 4D - Service 22
DID 1E4D - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #15 FORMENTOR_HVBAT_CELL_V_015Confirmed
- Request
22 1E 4E - Service 22
DID 1E4E - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #16 FORMENTOR_HVBAT_CELL_V_016Confirmed
- Request
22 1E 4F - Service 22
DID 1E4F - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #17 FORMENTOR_HVBAT_CELL_V_017Confirmed
- Request
22 1E 50 - Service 22
DID 1E50 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #18 FORMENTOR_HVBAT_CELL_V_018Confirmed
- Request
22 1E 51 - Service 22
DID 1E51 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #19 FORMENTOR_HVBAT_CELL_V_019Confirmed
- Request
22 1E 52 - Service 22
DID 1E52 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #20 FORMENTOR_HVBAT_CELL_V_020Confirmed
- Request
22 1E 53 - Service 22
DID 1E53 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #21 FORMENTOR_HVBAT_CELL_V_021Confirmed
- Request
22 1E 54 - Service 22
DID 1E54 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #22 FORMENTOR_HVBAT_CELL_V_022Confirmed
- Request
22 1E 55 - Service 22
DID 1E55 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #23 FORMENTOR_HVBAT_CELL_V_023Confirmed
- Request
22 1E 56 - Service 22
DID 1E56 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #24 FORMENTOR_HVBAT_CELL_V_024Confirmed
- Request
22 1E 57 - Service 22
DID 1E57 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #25 FORMENTOR_HVBAT_CELL_V_025Confirmed
- Request
22 1E 58 - Service 22
DID 1E58 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #26 FORMENTOR_HVBAT_CELL_V_026Confirmed
- Request
22 1E 59 - Service 22
DID 1E59 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #27 FORMENTOR_HVBAT_CELL_V_027Confirmed
- Request
22 1E 5A - Service 22
DID 1E5A - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #28 FORMENTOR_HVBAT_CELL_V_028Confirmed
- Request
22 1E 5B - Service 22
DID 1E5B - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #29 FORMENTOR_HVBAT_CELL_V_029Confirmed
- Request
22 1E 5C - Service 22
DID 1E5C - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #30 FORMENTOR_HVBAT_CELL_V_030Confirmed
- Request
22 1E 5D - Service 22
DID 1E5D - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #31 FORMENTOR_HVBAT_CELL_V_031Confirmed
- Request
22 1E 5E - Service 22
DID 1E5E - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #32 FORMENTOR_HVBAT_CELL_V_032Confirmed
- Request
22 1E 5F - Service 22
DID 1E5F - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #33 FORMENTOR_HVBAT_CELL_V_033Confirmed
- Request
22 1E 60 - Service 22
DID 1E60 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #34 FORMENTOR_HVBAT_CELL_V_034Confirmed
- Request
22 1E 61 - Service 22
DID 1E61 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #35 FORMENTOR_HVBAT_CELL_V_035Confirmed
- Request
22 1E 62 - Service 22
DID 1E62 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #36 FORMENTOR_HVBAT_CELL_V_036Confirmed
- Request
22 1E 63 - Service 22
DID 1E63 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #37 FORMENTOR_HVBAT_CELL_V_037Confirmed
- Request
22 1E 64 - Service 22
DID 1E64 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #38 FORMENTOR_HVBAT_CELL_V_038Confirmed
- Request
22 1E 65 - Service 22
DID 1E65 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #39 FORMENTOR_HVBAT_CELL_V_039Confirmed
- Request
22 1E 66 - Service 22
DID 1E66 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #40 FORMENTOR_HVBAT_CELL_V_040Confirmed
- Request
22 1E 67 - Service 22
DID 1E67 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #41 FORMENTOR_HVBAT_CELL_V_041Confirmed
- Request
22 1E 68 - Service 22
DID 1E68 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #42 FORMENTOR_HVBAT_CELL_V_042Confirmed
- Request
22 1E 69 - Service 22
DID 1E69 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #43 FORMENTOR_HVBAT_CELL_V_043Confirmed
- Request
22 1E 6A - Service 22
DID 1E6A - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #44 FORMENTOR_HVBAT_CELL_V_044Confirmed
- Request
22 1E 6B - Service 22
DID 1E6B - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #45 FORMENTOR_HVBAT_CELL_V_045Confirmed
- Request
22 1E 6C - Service 22
DID 1E6C - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #46 FORMENTOR_HVBAT_CELL_V_046Confirmed
- Request
22 1E 6D - Service 22
DID 1E6D - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #47 FORMENTOR_HVBAT_CELL_V_047Confirmed
- Request
22 1E 6E - Service 22
DID 1E6E - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #48 FORMENTOR_HVBAT_CELL_V_048Confirmed
- Request
22 1E 6F - Service 22
DID 1E6F - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #49 FORMENTOR_HVBAT_CELL_V_049Confirmed
- Request
22 1E 70 - Service 22
DID 1E70 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #50 FORMENTOR_HVBAT_CELL_V_050Confirmed
- Request
22 1E 71 - Service 22
DID 1E71 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #51 FORMENTOR_HVBAT_CELL_V_051Confirmed
- Request
22 1E 72 - Service 22
DID 1E72 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #52 FORMENTOR_HVBAT_CELL_V_052Confirmed
- Request
22 1E 73 - Service 22
DID 1E73 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #53 FORMENTOR_HVBAT_CELL_V_053Confirmed
- Request
22 1E 74 - Service 22
DID 1E74 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #54 FORMENTOR_HVBAT_CELL_V_054Confirmed
- Request
22 1E 75 - Service 22
DID 1E75 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #55 FORMENTOR_HVBAT_CELL_V_055Confirmed
- Request
22 1E 76 - Service 22
DID 1E76 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #56 FORMENTOR_HVBAT_CELL_V_056Confirmed
- Request
22 1E 77 - Service 22
DID 1E77 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #57 FORMENTOR_HVBAT_CELL_V_057Confirmed
- Request
22 1E 78 - Service 22
DID 1E78 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #58 FORMENTOR_HVBAT_CELL_V_058Confirmed
- Request
22 1E 79 - Service 22
DID 1E79 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #59 FORMENTOR_HVBAT_CELL_V_059Confirmed
- Request
22 1E 7A - Service 22
DID 1E7A - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #60 FORMENTOR_HVBAT_CELL_V_060Confirmed
- Request
22 1E 7B - Service 22
DID 1E7B - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #61 FORMENTOR_HVBAT_CELL_V_061Confirmed
- Request
22 1E 7C - Service 22
DID 1E7C - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #62 FORMENTOR_HVBAT_CELL_V_062Confirmed
- Request
22 1E 7D - Service 22
DID 1E7D - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #63 FORMENTOR_HVBAT_CELL_V_063Confirmed
- Request
22 1E 7E - Service 22
DID 1E7E - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #64 FORMENTOR_HVBAT_CELL_V_064Confirmed
- Request
22 1E 7F - Service 22
DID 1E7F - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #65 FORMENTOR_HVBAT_CELL_V_065Confirmed
- Request
22 1E 80 - Service 22
DID 1E80 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #66 FORMENTOR_HVBAT_CELL_V_066Confirmed
- Request
22 1E 81 - Service 22
DID 1E81 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #67 FORMENTOR_HVBAT_CELL_V_067Confirmed
- Request
22 1E 82 - Service 22
DID 1E82 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #68 FORMENTOR_HVBAT_CELL_V_068Confirmed
- Request
22 1E 83 - Service 22
DID 1E83 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #69 FORMENTOR_HVBAT_CELL_V_069Confirmed
- Request
22 1E 84 - Service 22
DID 1E84 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #70 FORMENTOR_HVBAT_CELL_V_070Confirmed
- Request
22 1E 85 - Service 22
DID 1E85 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #71 FORMENTOR_HVBAT_CELL_V_071Confirmed
- Request
22 1E 86 - Service 22
DID 1E86 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #72 FORMENTOR_HVBAT_CELL_V_072Confirmed
- Request
22 1E 87 - Service 22
DID 1E87 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #73 FORMENTOR_HVBAT_CELL_V_073Confirmed
- Request
22 1E 88 - Service 22
DID 1E88 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #74 FORMENTOR_HVBAT_CELL_V_074Confirmed
- Request
22 1E 89 - Service 22
DID 1E89 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #75 FORMENTOR_HVBAT_CELL_V_075Confirmed
- Request
22 1E 8A - Service 22
DID 1E8A - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #76 FORMENTOR_HVBAT_CELL_V_076Confirmed
- Request
22 1E 8B - Service 22
DID 1E8B - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #77 FORMENTOR_HVBAT_CELL_V_077Confirmed
- Request
22 1E 8C - Service 22
DID 1E8C - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #78 FORMENTOR_HVBAT_CELL_V_078Confirmed
- Request
22 1E 8D - Service 22
DID 1E8D - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #79 FORMENTOR_HVBAT_CELL_V_079Confirmed
- Request
22 1E 8E - Service 22
DID 1E8E - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #80 FORMENTOR_HVBAT_CELL_V_080Confirmed
- Request
22 1E 8F - Service 22
DID 1E8F - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #81 FORMENTOR_HVBAT_CELL_V_081Confirmed
- Request
22 1E 90 - Service 22
DID 1E90 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #82 FORMENTOR_HVBAT_CELL_V_082Confirmed
- Request
22 1E 91 - Service 22
DID 1E91 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #83 FORMENTOR_HVBAT_CELL_V_083Confirmed
- Request
22 1E 92 - Service 22
DID 1E92 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #84 FORMENTOR_HVBAT_CELL_V_084Confirmed
- Request
22 1E 93 - Service 22
DID 1E93 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #85 FORMENTOR_HVBAT_CELL_V_085Confirmed
- Request
22 1E 94 - Service 22
DID 1E94 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #86 FORMENTOR_HVBAT_CELL_V_086Confirmed
- Request
22 1E 95 - Service 22
DID 1E95 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #87 FORMENTOR_HVBAT_CELL_V_087Confirmed
- Request
22 1E 96 - Service 22
DID 1E96 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #88 FORMENTOR_HVBAT_CELL_V_088Confirmed
- Request
22 1E 97 - Service 22
DID 1E97 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #89 FORMENTOR_HVBAT_CELL_V_089Confirmed
- Request
22 1E 98 - Service 22
DID 1E98 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #90 FORMENTOR_HVBAT_CELL_V_090Confirmed
- Request
22 1E 99 - Service 22
DID 1E99 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #91 FORMENTOR_HVBAT_CELL_V_091Confirmed
- Request
22 1E 9A - Service 22
DID 1E9A - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #92 FORMENTOR_HVBAT_CELL_V_092Confirmed
- Request
22 1E 9B - Service 22
DID 1E9B - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #93 FORMENTOR_HVBAT_CELL_V_093Confirmed
- Request
22 1E 9C - Service 22
DID 1E9C - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #94 FORMENTOR_HVBAT_CELL_V_094Confirmed
- Request
22 1E 9D - Service 22
DID 1E9D - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #95 FORMENTOR_HVBAT_CELL_V_095Confirmed
- Request
22 1E 9E - Service 22
DID 1E9E - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery cell voltage, #96 FORMENTOR_HVBAT_CELL_V_096Confirmed
- Request
22 1E 9F - Service 22
DID 1E9F - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 1)- Range
- 3 to 4.5 V
- Unit
- V
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
Battery › Internal
Average battery consumption FORMENTOR_HVBAT_CSMP_AVG_INTConfirmed
- Request
22 2A B4 - Service 22
DID 2AB4 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 72 to 79 of the reply, 8 bits.
0x14 = 20 → 20 A
- Formula
val- Range
- 0 to 255 A
- Unit
- A
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
Estimated electric power reserve FORMENTOR_RANGE_EST_INTConfirmed
- Request
22 2A B4 - Service 22
DID 2AB4 - Module
710 → 77A - Every
1 s - Testing for 2020 to 2021
Example reply from a 2026 Cupra Formentor.
Bits 16 to 31 of the reply, 16 bits.
0x0062 = 98 → 98 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2022 to 2026. In testing for 2020 to 2021.
Battery › Modules
HV battery module temperature, #5 FORMENTOR_HVBAT_MOD_T_5Confirmed
- Request
22 1E B2 - Service 22
DID 1EB2 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery module temperature, #6 FORMENTOR_HVBAT_MOD_T_6Confirmed
- Request
22 1E B3 - Service 22
DID 1EB3 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery module temperature, #7 FORMENTOR_HVBAT_MOD_T_7Confirmed
- Request
22 1E B4 - Service 22
DID 1EB4 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.
HV battery module temperature, #8 FORMENTOR_HVBAT_MOD_T_8Confirmed
- Request
22 1E B5 - Service 22
DID 1EB5 - Module
FC00 → FE007B - Every
1 s - Testing for 2020 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8 − 40)- Range
- -40 to 8151.875 °C
- Unit
- °C
Confirmed for 2025. In testing for 2020 to 2021, 2023, 2026. Not supported for 2022, 2024.