Engine oil temperature SEQUOIA_EOT_700Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 10 7B
  • Service 22DID 107B
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 192 to 199 of the reply, 8 bits.

0x47 = 71 → (71 − 40) = 31 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/F heater duty bank 1 sensor 1 SEQUOIA_F_HEATER_DUTY_B1S1

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.9 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

A/F ratio learn value high, bank 1 SEQUOIA_AF_LEARN_HIGH_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 32 to 39 of the reply, 8 bits.

0x8E = 142 → (142 × 100 ÷ 255 − 50) = 5.686275 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

A/F ratio learn value idle, bank 1 SEQUOIA_AF_LEARN_IDLE_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

A/F ratio learn value low, bank 1 SEQUOIA_AF_LEARN_LOW_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

A/F ratio learn value mid.1, bank 1 SEQUOIA_AF_LEARN_MID1_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

0x9A = 154 → (154 × 100 ÷ 255 − 50) = 10.392157 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

A/F ratio learn value mid.2, bank 1 SEQUOIA_AF_LEARN_MID2_PORT_B1Confirmed

  • Request22 10 A2
  • Service 22DID 10A2
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 24 to 31 of the reply, 8 bits.

0x8D = 141 → (141 × 100 ÷ 255 − 50) = 5.294118 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

A/F ratio learned high, bank 1 SEQUOIA_A_F_RATIO_LEARNED_HIGH_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 32 to 39 of the reply, 8 bits.

0x8A = 138 → (138 × 100 ÷ 255 − 50) = 4.117647 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

A/F ratio learned idle, bank 1 SEQUOIA_A_F_RATIO_LEARNED_IDLE_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

A/F ratio learned low, bank 1 SEQUOIA_A_F_RATIO_LEARNED_LOW_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

0x7C = 124 → (124 × 100 ÷ 255 − 50) = -1.372549 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

A/F ratio learned mid 1, bank 1 SEQUOIA_A_F_RATIO_LEARNED_MID_1_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

0x7C = 124 → (124 × 100 ÷ 255 − 50) = -1.372549 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

A/F ratio learned mid 2, bank 1 SEQUOIA_A_F_RATIO_LEARNED_MID_2_BANK_1Confirmed

  • Request22 10 2A
  • Service 22DID 102A
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 24 to 31 of the reply, 8 bits.

0x8C = 140 → (140 × 100 ÷ 255 − 50) = 4.901961 %

Formula
(val × 100 ÷ 255 − 50)
Range
-50 to 50 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

A/F test results 1, incomplete SEQUOIA_F_TEST_RESULTS_1

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Accessory relay on SEQUOIA_ACC_RELAY_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 46 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Accumulator open SEQUOIA_ACCUMULATOR_OPEN

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 16 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2018, 2020. Not supported for 2006, 2013, 2023 to 2025.

Acoustic control induction system vacuum switching valve on SEQUOIA_ACIS_VSV_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Actual engine torque SEQUOIA_ACT_ENG_TQ

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 24 to 39 of the reply, 16 bits.

Formula
(val − 32768)
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Actuator power supply on SEQUOIA_ACTUATOR_POWER_SUP_ON

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 146 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Air conditioning compressor SEQUOIA_AC_COMP

  • Request21 E6
  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Air conditioning power consumption SEQUOIA_AC_POWER_CONSConfirmed

  • Request22 10 6E
  • Service 22DID 106E
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 20) = 0 kW

Formula
(val ÷ 20)
Range
0 to 12.75 kW
Unit
kW

Confirmed for 2023. In testing for 2024 to 2026.

Air mix servo target pulse, driver SEQUOIA_AIR_MIX_SERVO_TARG_D

  • Request21 41
  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Air mix servo, actual pulse, d SEQUOIA_AIR_MIX_SERVO_ACT_D

  • Request21 41
  • Service 21PID 41
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Air-fuel equivalence ratio, bank 1 sensor 1 SEQUOIA_AF_LAMBDA_B1S1Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 1.99 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Air-fuel sensor current, bank 1 sensor 1 SEQUOIA_AFS_I_B1S1Confirmed

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.99 mA
Unit
mA

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Air-fuel sensor voltage, bank 1 sensor 1 SEQUOIA_AFS_V_B1S1Confirmed

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 7.99 ÷ 65535)
Range
0 to 7.99 V
Unit
V

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Alt voltage - active test SEQUOIA_ALT_VOL_ACTIVE_TEST

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Alt voltage - non active test SEQUOIA_ALT_VOL_NON_ACTIVE

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Alternator output duty SEQUOIA_ALTERNATOR_OUTPUT

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.9 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Alternator output duty cycle SEQUOIA_ALT_DUTY_CYCLE

  • Request22 15 FA
  • Service 22DID 15FA
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 164)
Range
0 to 399 %
Unit
%

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Ambient temperature SEQUOIA_AAT_7D2Confirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Atmospheric pressure SEQUOIA_ATMOSPHERE_PRESSUREConfirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 48 to 55 of the reply, 8 bits.

0x62 = 98 → 98 kPa

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Atmospheric pressure SEQUOIA_ATMOSPHERE_PRESSURE_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 56 to 63 of the reply, 8 bits.

0x63 = 99 → 99 kPa

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Automatic transmission fluid thermal degradation estimate SEQUOIA_ATF_THERMAL_DEGRAD_ESTConfirmed

  • Request22 16 2B
  • Service 22DID 162B
  • Module701 → 709
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x0096 = 150 → 150

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2006, 2013, 2023. Supported for 2005, 2007, 2011, 2020, 2024 to 2025.

Calculated load SEQUOIA_CALCULATED_LOAD_7E0Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x3F = 63 → (63 × 100 ÷ 255) = 24.705882 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2006, 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016.

Calculated load SEQUOIA_CALCULATED_LOAD_7E0_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x34 = 52 → (52 × 100 ÷ 255) = 20.392157 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Catalyst temperature bank 2 sensor 1 SEQUOIA_CAT_T_BANK_2_SENS_1Confirmed

  • Request22 1F 3D
  • Service 22DID 1F3D
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2024, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x19A2 = 6562 → (6562 × 9 ÷ 50 − 40) = 1,141.16 °F

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756.3 °F
Unit
°F

Confirmed for 2023, 2025. In testing for 2000 to 2022, 2024, 2026.

Catalyst temperature bank 2 sensor 2 SEQUOIA_CAT_T_BANK_2_SENS_2Confirmed

  • Request22 1F 3F
  • Service 22DID 1F3F
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2024, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x1650 = 5712 → (5712 × 9 ÷ 50 − 40) = 988.16 °F

Formula
(val × 9 ÷ 50 − 40)
Range
-40 to 11756.3 °F
Unit
°F

Confirmed for 2023, 2025. In testing for 2000 to 2022, 2024, 2026.

Catalyst temperature, bank 1 sensor 1 SEQUOIA_CAT_T_B1S1Confirmed

  • Request21 05
  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2023 to 2025.

Catalyst temperature, bank 1 sensor 2 SEQUOIA_CAT_T_B1S2Confirmed

  • Request21 05
  • Service 21PID 05
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2023 to 2025.

Catalyst temperature, bank 1 sensor 2, variant 2 SEQUOIA_CAT_T_B1S2_V2

  • Request21 3E
  • Service 21PID 3E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Check mode on SEQUOIA_CHECK_MODE_ON

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Closed throttle position switch on SEQUOIA_CLOSED_THROTTLE_POS_ON

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 125 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Codes, include history SEQUOIA_CODES_INCLUDE

  • Request21 E1
  • Service 21PID E1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2006, 2013, 2023. Supported for 2024 to 2025.

Continuously variable transmission learning complete SEQUOIA_CVT_LEARNED

  • Request21 DD
  • Service 21PID DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Continuously variable transmission oil pressure SEQUOIA_CVT_OIL_P

  • Request21 BE
  • Service 21PID BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 40)
Range
0 to 10200 kPa
Unit
kPa

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Coolant temperature SEQUOIA_COOL_TConfirmed

  • Request22 1F 05
  • Service 22DID 1F05
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x51 = 81 → (81 − 40) = 41 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Coolant temperature SEQUOIA_COOLANT_TEMP_7E0Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 56 to 63 of the reply, 8 bits.

0x82 = 130 → (130 − 40) = 90 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Coolant temperature SEQUOIA_COOLANT_TEMP_7E0_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 64 to 71 of the reply, 8 bits.

0x82 = 130 → (130 − 40) = 90 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Coolant water route switching valve 1, closed? SEQUOIA_COOLANT_VALVE_1_CLOSE

  • Request22 28 2C
  • Service 22DID 282C
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Coolant water route switching valve 2, closed? SEQUOIA_COOLANT_VALVE_2_CLOSE

  • Request22 28 47
  • Service 22DID 2847
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Cooling fan duty ratio SEQUOIA_COOLING_FAN_DUTY_RATIOConfirmed

  • Request22 10 46
  • Service 22DID 1046
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 127.5 ÷ 255) = 0 %

Formula
(val × 127.5 ÷ 255)
Range
0 to 127.5 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Cruise control on SEQUOIA_CRUISE_CTRL_ON

  • Request21 D3
  • Service 21PID D3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 25 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Cylinder 1 injection volume SEQUOIA_CYL_1_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Cylinder 2 injection volume SEQUOIA_CYL_2_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Cylinder 3 injection volume SEQUOIA_CYL_3_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Cylinder 4 injection volume SEQUOIA_CYL_4_INJ_VOLUME

  • Request22 11 31
  • Service 22DID 1131
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Cylinder number SEQUOIA_CYLINDER_NUMBER

  • Request21 C1
  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Destination SEQUOIA_DESTINATION

  • Request21 C1
  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Dist battery cable disconnect SEQUOIA_DIST_BATT_CABLE

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Electric fan motor on SEQUOIA_ELEC_FAN_MOTOR_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Electric thermostat duty ratio SEQUOIA_ELECTRIC_THERMOSTAT_DUTY_RATIO

  • Request22 28 29
  • Service 22DID 2829
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Electric water pump SEQUOIA_ELECTRIC_WATER_PUMP

  • Request22 28 27
  • Service 22DID 2827
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 40)
Range
0 to 10200 rpm
Unit
rpm

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Electric water pump RPM SEQUOIA_EWP_RPM

  • Request22 10 43
  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Electric water pump target speed SEQUOIA_EWP_TARGET_VSS

  • Request22 10 43
  • Service 22DID 1043
  • Module700 → 708
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Engine coolant temperature SEQUOIA_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request21 26
  • Service 21PID 26
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 89.25 ÷ 255 + 1.3)
Range
1.3 to 90.55 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.

Engine coolant temperature SEQUOIA_ECT_7C0Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request21 23
  • Service 21PID 23
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.

Engine coolant temperature, at ignition SEQUOIA_ECT_IGNConfirmed

  • Request22 10 41
  • Service 22DID 1041
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x75 = 117 → (117 × 62.5 ÷ 100 − 40) = 33.125 °C

Formula
(val × 62.5 ÷ 100 − 40)
Range
-40 to 119.375 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Engine coolant temperature, initial SEQUOIA_ECT_INITConfirmed

  • Request22 10 41
  • Service 22DID 1041
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

0x76 = 118 → (118 × 62.5 ÷ 100 − 40) = 33.75 °C

Formula
(val × 62.5 ÷ 100 − 40)
Range
-40 to 119.375 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Engine independent SEQUOIA_ENG_INDEPENDENT

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 91 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Engine independent control SEQUOIA_ENG_INDEPENDENT_CTRL

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Engine oil pressure SEQUOIA_EOPConfirmed

  • Request22 10 74
  • Service 22DID 1074
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 10 ÷ 128) = 0 kPa

Formula
(val × 10 ÷ 128)
Range
0 to 5119.92 kPa
Unit
kPa

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Engine oil pressure control valve SEQUOIA_EOP_CONTROL_VALVE

  • Request22 28 48
  • Service 22DID 2848
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0762939)
Range
0 to 4999.9207 mA
Unit
mA

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Engine oil temperature SEQUOIA_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 72 to 79 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2023 to 2025.

Engine oil temperature SEQUOIA_EOT_700Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 10 7B
  • Service 22DID 107B
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 192 to 199 of the reply, 8 bits.

0x47 = 71 → (71 − 40) = 31 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Engine oil temperature, variation 2 SEQUOIA_EOT_V2Confirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 1F 5C
  • Service 22DID 1F5C
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x4A = 74 → (74 − 40) = 34 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Engine run time SEQUOIA_ENGINE_RUN_TIMEConfirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 88 to 103 of the reply, 16 bits.

0x0444 = 1092 → 1,092 s

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Engine run time SEQUOIA_ENGINE_RUN_TIME_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 96 to 111 of the reply, 16 bits.

0x07D0 = 2000 → 2,000 s

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Engine run time, up to 255 sec. only SEQUOIA_ENG_RUN_TIME_UP_255

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 s
Unit
s

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Engine speed SEQUOIA_ENGINE_SPEED_7E0Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 64 to 79 of the reply, 16 bits.

0x0AE3 = 2787 → (2787 ÷ 4) = 696.75 rpm

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Engine speed SEQUOIA_ENGINE_SPEED_7E0_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 72 to 87 of the reply, 16 bits.

0x0DA2 = 3490 → (3490 ÷ 4) = 872.5 rpm

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Engine stall control FB flow SEQUOIA_ENG_STALL_CTRL_FB

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096 − 40)
Range
-40 to 39.99
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Evaporative purge duty SEQUOIA_EVAP_PURGE_DUTY_7E0

  • Request21 2E
  • Service 21PID 2E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Evaporative purge flow SEQUOIA_EVAP_PURGE_FLOW

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.99 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Evaporative purge vacuum switching valve on SEQUOIA_EVAP_PURGE_VSV_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 11 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Exhaust gas recirculation step position SEQUOIA_EGR_STEP_POSITIONConfirmed

  • Request21 47
  • Service 21PID 47
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2006, 2008 to 2026

Example reply from a 2007 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x84 = 132 → 132

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2007. In testing for 2000 to 2006, 2008 to 2022, 2024 to 2026. Not supported for 2023.

Exhaust gas recirculation temperature SEQUOIA_EGR_T

  • Request21 ED
  • Service 21PID ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 53 ÷ 85)
Range
0 to 159 °C
Unit
°C

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Exhaust gas recirculation valve step SEQUOIA_EGR_STEP

  • Request21 E7
  • Service 21PID E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Exhaust VVT change angle, bank 1 SEQUOIA_EXHAUST_VVT_ANGLE_B1Confirmed

  • Request22 10 88
  • Service 22DID 1088
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Exhaust VVT hold learn value, bank 1 SEQUOIA_EXHAUST_VVT_HOLD_LEARN_B1Confirmed

  • Request22 10 89
  • Service 22DID 1089
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x1E67 = 7783 → (7783 × 399.9 ÷ 65535) = 47.492511 %

Formula
(val × 399.9 ÷ 65535)
Range
0 to 399.9 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Exhaust VVT oil control valve control duty SEQUOIA_EXHAUST_VVT_OCV_CONTROL_DUTYConfirmed

  • Request22 10 62
  • Service 22DID 1062
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x0082 = 130 → (130 × 400 ÷ 65535) = 0.793469 %

Formula
(val × 400 ÷ 65535)
Range
0 to 400 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Exhaust VVT target angle B1 SEQUOIA_EXHAUST_VVT_TARGET_ANGLE_B1Confirmed

  • Request22 10 71
  • Service 22DID 1071
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Exhaust VVT timing most over-advanced learn value, bank 1 SEQUOIA_EXHAUST_VVT_OVER_ADV_LEARN_B1Confirmed

  • Request22 10 8F
  • Service 22DID 108F
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x2FB1 = 12209 → (12209 × 639.99 ÷ 65535) = 119.228472 °

Formula
(val × 639.99 ÷ 65535)
Range
0 to 639.99 °
Unit
°

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Front/rear motor torque ratio SEQUOIA_FRONT_REAR_MOTOR_TQConfirmed

  • Request22 10 39
  • Service 22DID 1039
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 16 to 31 of the reply, 16 bits.

0x0988 = 2440 → (2440 ÷ 1000 − 32.768) = -30.328

Formula
(val ÷ 1000 − 32.768)
Range
-32.76 to 32.76
Unit
Number

Confirmed for 2023. In testing for 2024 to 2026.

Fuel cut for engine stop request SEQUOIA_F_C_ENG_STOP_REQ

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 92 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Fuel cut TAU on SEQUOIA_FC_TAU_ON

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Fuel filter temperature SEQUOIA_FFT

  • Request22 10 9A
  • Service 22DID 109A
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

G sensor calibration, complete SEQUOIA_G_SENS_CALIBRATION

  • Request21 83
  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

G sensor learning value SEQUOIA_G_SENS_LEARNING

  • Request21 83
  • Service 21PID 83
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Generator inverter temperature SEQUOIA_GEN_INVERTER_T

  • Request22 10 A4
  • Service 22DID 10A4
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026. Not supported for 2023.

Generator inverter temperature SEQUOIA_GEN_INVERTER_T_7D2

  • Request22 10 A8
  • Service 22DID 10A8
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026. Not supported for 2023.

Generator inverter temperature after ignition on SEQUOIA_GEN_INVERTER_T_AFTER_ON

  • Request22 10 A8
  • Service 22DID 10A8
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026. Not supported for 2023.

Glass humidity SEQUOIA_GLASS_HUMIDITY

  • Request21 B1
  • Service 21PID B1
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 13107)
Range
0 to 100 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Glass temperature SEQUOIA_GLASS_T

  • Request21 AF
  • Service 21PID AF
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 9 ÷ 500 − 557.8)
Range
-557 to 621 °F
Unit
°F

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Hydraulic valve, communication open SEQUOIA_HV_COMM_OPEN

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 17 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2018, 2020. Not supported for 2006, 2013, 2023 to 2025.

Idle control SEQUOIA_IDLE_CTRL

  • Request21 E6
  • Service 21PID E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Idle spark advance control 1 SEQUOIA_IDLE_SPARK_ADVN_CTRL_1

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Idle spark advance control 2 SEQUOIA_IDLE_SPARK_ADVN_CTRL_2

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Idle spark advance control 3 SEQUOIA_IDLE_SPARK_ADVN_CTRL_3

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Idle spark advance control 4 SEQUOIA_IDLE_SPARK_ADVN_CTRL_4

  • Request21 52
  • Service 21PID 52
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.93 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Idle spark advance control, cylinder 1 SEQUOIA_IDLE_SAC_CYL_1

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Idle spark advance control, cylinder 2 SEQUOIA_IDLE_SAC_CYL_2

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Idle spark advance control, cylinder 3 SEQUOIA_IDLE_SAC_CYL_3

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Idle spark advance control, cylinder 4 SEQUOIA_IDLE_SAC_CYL_4

  • Request22 10 78
  • Service 22DID 1078
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 6.25 ÷ 100)
Range
0 to 15.9375 °
Unit
°

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Idle speed control learning SEQUOIA_IDLE_SPD_CTRL

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 93 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Idle speed control learning value, l/s SEQUOIA_IDLE_SPD_CTRL_L_S

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val × 0.0012206912)
Range
0 to 79.99
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

IG OFF elapsed time SEQUOIA_IG_OFF_ELAPSED_TIME

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 min
Unit
min

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Ignition advance SEQUOIA_SPARKADV_21

  • Request21 0E
  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Ignition timing advance SEQUOIA_IGN_ADVANCEConfirmed

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Immobilizer communication on SEQUOIA_IMMOBILIZER_ON

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 120 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Initial engine coolant temperature SEQUOIA_INITIAL_ECT

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 531 ÷ 850 − 40)
Range
-40 to 119.3
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Initial intake air temperature SEQUOIA_INITIAL_IAT

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 5 ÷ 8 − 40)
Range
-40 to 119 °C
Unit
°C

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Injection SEQUOIA_INJECTIONConfirmed

  • Request22 10 19
  • Service 22DID 1019
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x01 = 1 → DIRECT

Unit
Named states
States
Raw valueStateMeaning
1DIRECTDirect
2BOTHBoth

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Injection duration for cylinder 1 SEQUOIA_INJ_DUR_CYL_1

  • Request21 3C
  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 ms
Unit
ms

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Injection feedback value 1 SEQUOIA_INJ_FEEDBACK_1

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 1 SEQUOIA_INJ_FEEDBACK_1_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 2 SEQUOIA_INJ_FEEDBACK_2

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 2 SEQUOIA_INJ_FEEDBACK_2_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 3 SEQUOIA_INJ_FEEDBACK_3

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 3 SEQUOIA_INJ_FEEDBACK_3_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 4 SEQUOIA_INJ_FEEDBACK_4

  • Request22 11 2B
  • Service 22DID 112B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 5 ÷ 32 − 20)
Range
-20 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 4 SEQUOIA_INJ_FEEDBACK_4_700

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 5 SEQUOIA_INJ_FEEDBACK_5

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection feedback value 6 SEQUOIA_INJ_FEEDBACK_6

  • Request22 11 B8
  • Service 22DID 11B8
  • Module700 → 708
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 332 ÷ 2125 − 19.99811765)
Range
-19.9981 to 19.8418
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume SEQUOIA_INJ_VOLConfirmed

  • Request22 10 17
  • Service 22DID 1017
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 3200) = 0 L

Formula
(val ÷ 3200)
Range
0 to 20 L
Unit
L

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Injection volume - target SEQUOIA_INJ_VOLUME_TGT

  • Request22 11 2C
  • Service 22DID 112C
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000)
Range
0 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume 1 SEQUOIA_INJ_VOLUME_1

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume 2 SEQUOIA_INJ_VOLUME_2

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume 3 SEQUOIA_INJ_VOLUME_3

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume 5 SEQUOIA_INJ_VOLUME_5

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume 6 SEQUOIA_INJ_VOLUME_6

  • Request22 11 8B
  • Service 22DID 118B
  • Module700 → 708
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-40 to 300
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injection volume per 10 injections, cylinder 1 SEQUOIA_INJ_VOL_CYL_1

  • Request21 3C
  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32000000)
Range
0 to 0.002 L
Unit
L

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Injection volume total SEQUOIA_INJ_VOLUME_TOT

  • Request22 11 2F
  • Service 22DID 112F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 19531 ÷ 1000000 − 640)
Range
-640 to 15
Unit
Raw value

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Injector port SEQUOIA_INJECTOR_PORTConfirmed

  • Request22 10 18
  • Service 22DID 1018
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 1000) = 0 ms

Formula
(val ÷ 1000)
Range
0 to 65.535 ms
Unit
ms

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Injector pulse width SEQUOIA_INJ_PW

  • Request21 E4
  • Service 21PID E4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 163 ÷ 1275)
Range
0 to 32.6 ms
Unit
ms

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Injector pulse width SEQUOIA_INJ_WIDTH

  • Request21 F3
  • Service 21PID F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 16 ÷ 125)
Range
0 to 32.64 ms
Unit
ms

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Input shaft speed SEQUOIA_SPD_NIN

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Intake air temperature SEQUOIA_IAT_21

  • Request21 0F
  • Service 21PID 0F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Intake air temperature SEQUOIA_INTAKE_AIR_7E0_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 48 to 55 of the reply, 8 bits.

0x2D = 45 → (45 − 40) = 5 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Intake air temperature, bank 1 sensor 1 SEQUOIA_IAT_B1S1Confirmed

  • Request22 1F 77
  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2024, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

0x3A = 58 → (58 − 40) = 18 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025. In testing for 2000 to 2022, 2024, 2026.

Intake air temperature, bank 1 sensor 2 SEQUOIA_IAT_B1S2Confirmed

  • Request22 1F 77
  • Service 22DID 1F77
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2024, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → (0 − 40) = -40 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025. In testing for 2000 to 2022, 2024, 2026.

Intake VVT change angle, bank 1 SEQUOIA_INTAKE_VVT_CHANGE_ANGLE_BANK_1Confirmed

  • Request22 10 87
  • Service 22DID 1087
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Intake VVT most over-retarded learn value, bank 1 SEQUOIA_INTAKE_VVT_OVER_RET_LEARN_B1Confirmed

  • Request22 10 8D
  • Service 22DID 108D
  • Module700 → 708
  • Every3600 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x0CFF = 3327 → (3327 × 639.99 ÷ 65535) = 32.490222 °

Formula
(val × 639.99 ÷ 65535)
Range
0 to 639.99 °
Unit
°

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Intake VVT target angle B1 SEQUOIA_INTAKE_VVT_TARGET_ANGLE_B1Confirmed

  • Request22 10 6F
  • Service 22DID 106F
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 639.9 ÷ 65535) = 0 °

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Integrated engine run time SEQUOIA_INTEGRATED_ENG_RUN

  • Request22 15 E8
  • Service 22DID 15E8
  • Module700 → 708
  • Every3600 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 h
Unit
h

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Intercooler coolant temperature SEQUOIA_INTERCOOLER_ECT

  • Request22 11 9C
  • Service 22DID 119C
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Intercooler water pump SEQUOIA_INTERCOOLER_WATERConfirmed

  • Request22 28 20
  • Service 22DID 2820
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2024, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 80 ÷ 13107) = 0 %

Formula
(val × 80 ÷ 13107)
Range
0 to 300 %
Unit
%

Confirmed for 2023, 2025. In testing for 2000 to 2022, 2024, 2026.

Internal temperature SEQUOIA_ECU_INTERNAL_TConfirmed

  • Request22 10 5E
  • Service 22DID 105E
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x37 = 55 → (55 − 40) = 15 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Inverter coolant temperature SEQUOIA_INVRT_COOLANT_TConfirmed

  • Request22 10 B2
  • Service 22DID 10B2
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x33 = 51 → (51 − 40) = 11 °C

Formula
(val − 40)
Range
0 to 100 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Inverter water pump duty SEQUOIA_INVERTER_WATER_PMP

  • Request22 11 12
  • Service 22DID 1112
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 15259 ÷ 5000000)
Range
0 to 199 %
Unit
%

In testing for 2024 to 2026. Not supported for 2023.

Judge time engine ignition SEQUOIA_JUDGE_TIME_ENG_IGN

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 s
Unit
s

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Judge time engine output SEQUOIA_JUDGE_TIME_ENG

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 s
Unit
s

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Key cycle SEQUOIA_KEY_CYCLEConfirmed

  • Request22 01 02
  • Service 22DID 0102
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x2494 = 9364 → 9,364

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023. In testing for 2024 to 2026.

Knock adjust SEQUOIA_KNOCK_ADJUST

  • Request21 B2
  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 64)
Range
-64 to 1984 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Knock adjust SEQUOIA_KNOCK_ADJUST_7E0

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 1024)
Range
-1024 to 1024 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Knock correct learn value SEQUOIA_KNOCK_CORRECT_LEARN

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 32 − 1024)
Range
-1024 to 1023 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Knock correction, learned value SEQUOIA_KNOCK_CORRECT_LEARNED_VALUEConfirmed

  • Request22 10 5C
  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x81DE = 33246 → (33246 × 312.5 ÷ 10000 − 1024) = 14.9375

Formula
(val × 312.5 ÷ 10000 − 1024)
Range
-1024 to 1023
Unit
Number

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Knock feedback SEQUOIA_KNOCK_FEEDBACK

  • Request21 B2
  • Service 21PID B2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 64)
Range
-64 to 1984 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Knock feedback SEQUOIA_KNOCK_FEEDBACK_7E0

  • Request21 37
  • Service 21PID 37
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 2048 ÷ 65535 − 1024)
Range
-1024 to 1024 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Knock feedback value SEQUOIA_KNOCK_FEEDBACK_VALUEConfirmed

  • Request22 10 5C
  • Service 22DID 105C
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 31 of the reply, 16 bits.

0x7FA0 = 32672 → (32672 × 312.5 ÷ 10000 − 1024) = -3

Formula
(val × 312.5 ÷ 10000 − 1024)
Range
-1024 to 1023
Unit
Number

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Lock up state SEQUOIA_LOCK_UP_STATEConfirmed

  • Request22 16 20
  • Service 22DID 1620
  • Module701 → 709
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bit 7 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Long term fuel trim, bank 1 SEQUOIA_LONG_FT_B1Confirmed

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Long term fuel trim, bank 2 SEQUOIA_LONG_FT_B2Confirmed

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Long-term fuel trim, bank 1 SEQUOIA_LTFT1_21

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.7809803922 − 100)
Range
-100 to 99.15 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Manifold absolute pressure SEQUOIA_MAP_7E0Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 40 to 47 of the reply, 8 bits.

0x6A = 106 → 106 kPa

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Manifold absolute pressure SEQUOIA_MAP_7E0_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 40 to 47 of the reply, 8 bits.

0x2D = 45 → 45 kPa

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Mass air flow SEQUOIA_MAF_21

  • Request21 10
  • Service 21PID 10
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 g/s
Unit
g/s

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Mass air flow SEQUOIA_MAF_7E0Confirmed

Pelican can show this parameter as the mass air flow.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 24 to 39 of the reply, 16 bits.

0x01F2 = 498 → (498 ÷ 100) = 4.98 g/s

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Mass air flow SEQUOIA_MAF_7E0_V2Confirmed

Pelican can show this parameter as the mass air flow.

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 24 to 39 of the reply, 16 bits.

0x0214 = 532 → (532 ÷ 100) = 5.32 g/s

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Master cylinder open SEQUOIA_MASTER_CYLINDER_OPENConfirmed

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 8 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2023 to 2025.

Master cylinder sensor temperature SEQUOIA_MASTER_CYL_TEMPConfirmed

  • Request22 10 06
  • Service 22DID 1006
  • Module7B0 → 7B8
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x5A = 90 → (90 − 80) = 10 °C

Formula
(val − 80)
Range
-20 to 100 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Maximum generator inverter temperature SEQUOIA_MAX_GEN_INVERTER_T

  • Request22 10 A8
  • Service 22DID 10A8
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026. Not supported for 2023.

Maximum motor inverter temperature SEQUOIA_MAX_MOTOR_INVERTER_TConfirmed

  • Request22 10 A5
  • Service 22DID 10A5
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

0x63 = 99 → (99 − 40) = 59 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2024 to 2026.

Misfire count, all cylinders SEQUOIA_MISFIRE_CNTConfirmed

  • Request22 10 A5
  • Service 22DID 10A5
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Misfire count, cylinder 1 SEQUOIA_MISFIRE_CYL1

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Misfire count, cylinder 2 SEQUOIA_MISFIRE_CYL2

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Misfire count, cylinder 3 SEQUOIA_MISFIRE_CYL3

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Misfire count, cylinder 4 SEQUOIA_MISFIRE_CYL4

  • Request22 10 A7
  • Service 22DID 10A7
  • Module700 → 708
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Misfire load SEQUOIA_MISFIRE_LOADConfirmed

  • Request22 10 AA
  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 510 ÷ 255) = 0 %

Formula
(val × 510 ÷ 255)
Range
0 to 510 %
Unit
%

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Misfire margin SEQUOIA_MISFIRE_MARGIN

  • Request22 10 AA
  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 rpm
Unit
rpm

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2023 to 2025. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Misfire RPM SEQUOIA_MISFIRE_RPM

  • Request22 10 AA
  • Service 22DID 10AA
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 6375 ÷ 255)
Range
0 to 6375 rpm
Unit
rpm

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2023 to 2025. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Misfire RPM SEQUOIA_MISFIRE_RPM_7E0Confirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Misfire test result, incomplete SEQUOIA_MIS_TEST_RESULT

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Model year SEQUOIA_MODEL_YEAR

  • Request21 C1
  • Service 21PID C1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
(val + 1900)
Range
1900 to 2155
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Motor inverter temperature SEQUOIA_MOTOR_INVERTER_TConfirmed

  • Request22 10 A5
  • Service 22DID 10A5
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x45 = 69 → (69 − 40) = 29 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2024 to 2026.

Motor inverter temperature after ignition on SEQUOIA_MOTOR_INVERTER_T_ONConfirmed

  • Request22 10 A5
  • Service 22DID 10A5
  • Module7D2 → 7DA
  • Every5 s
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

0x4C = 76 → (76 − 40) = 36 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023. In testing for 2024 to 2026.

Motor inverter, maximum temperature SEQUOIA_M_INVRT_MAX_T

  • Request22 10 A6
  • Service 22DID 10A6
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020, 2023 to 2025.

Motor regenerative brake torque SEQUOIA_MOTOR_REGENERATIVE_BREAKConfirmed

  • Request22 10 69
  • Service 22DID 1069
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 16 to 31 of the reply, 16 bits.

0x8000 = 32768 → (32768 ÷ 8 − 4096) = 0 kW

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 kW
Unit
kW

Confirmed for 2023. In testing for 2024 to 2026.

Motor regenerative brake torque, requested SEQUOIA_MOTOR_REGENERATIVEConfirmed

  • Request22 10 69
  • Service 22DID 1069
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2024 to 2026

Example reply from a 2023 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x8000 = 32768 → (32768 ÷ 8 − 4096) = 0 kW

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 kW
Unit
kW

Confirmed for 2023. In testing for 2024 to 2026.

Motor RPM SEQUOIA_RPM_7D2Confirmed

  • Request22 10 A1
  • Service 22DID 10A1
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x7FFE = 32766 → (32766 − 32768) = -2 rpm

Formula
(val − 32768)
Range
-32768 to 32767 rpm
Unit
rpm

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Motor torque SEQUOIA_TQConfirmed

  • Request22 10 A1
  • Service 22DID 10A1
  • Module7D2 → 7DA
  • Every250 ms
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 48 to 63 of the reply, 16 bits.

0x8002 = 32770 → (32770 ÷ 8 − 4096) = 0.25 N·m

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 N·m
Unit
N·m

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

O2 heater b1s2_active SEQUOIA_O2_HEATER_B1S2

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 68 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

O2 heater current val bank 1 sensor 2 SEQUOIA_O2_HEATER_CURR_VAL

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 4.999 A
Unit
A

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Open side malfunction on SEQUOIA_OPEN_SIDE_ON

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 145 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Output shaft speed SEQUOIA_SPD_NOUT

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

OXS1, A/FS2 test result, incomplete SEQUOIA_OXS1_FS2_TEST_RESULT

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Oxygen sensor voltage, bank 1 sensor 1 SEQUOIA_O2S11_V

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.0049960784)
Range
0 to 1.27 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Oxygen sensor voltage, bank 1 sensor 2 SEQUOIA_O2S_B1S2Confirmed

  • Request21 04
  • Service 21PID 04
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 144 to 151 of the reply, 8 bits.

Formula
(val × 5 ÷ 1000)
Range
0 to 1.275 V
Unit
V

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

PM accumulation ratio - bank 1 SEQUOIA_PM_ACCUMULATION_RAT_1

  • Request22 11 05
  • Service 22DID 1105
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 15 %
Unit
%

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

Purge cut vacuum switching valve duty SEQUOIA_PURGE_CUT_VSV_DUTY

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 25 ÷ 4096)
Range
0 to 399.9 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Racing operation SEQUOIA_RACING_OPERATION

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 90 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Rear motor inverter, coolant temperature SEQUOIA_RM_INVRT_COOL_T

  • Request22 10 A6
  • Service 22DID 10A6
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020, 2023 to 2025.

Rear motor regenerative brake torque SEQUOIA_REAR_MOTOR_REGENERATIVE

  • Request22 10 6A
  • Service 22DID 106A
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 kW
Unit
kW

In testing for 2024 to 2026. Not supported for 2023.

Rear motor regenerative brake torque, requested SEQUOIA_REAR_MOTOR

  • Request22 10 6A
  • Service 22DID 106A
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 kW
Unit
kW

In testing for 2024 to 2026. Not supported for 2023.

Rear motor speed SEQUOIA_RM_TQ_REQ

  • Request22 10 A2
  • Service 22DID 10A2
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 32768)
Range
-32768 to 32767 rpm
Unit
rpm

In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020, 2023 to 2025.

Rear motor torque SEQUOIA_RM_TQ

  • Request22 10 A2
  • Service 22DID 10A2
  • Module7D2 → 7DA
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 8 − 4096)
Range
-4096 to 4095 N·m
Unit
N·m

In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020, 2023 to 2025.

Regulator pressure SEQUOIA_REGULATOR_PConfirmed

  • Request21 53
  • Service 21PID 53
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 375105 ÷ 25500 − 456.68)
Range
-456.68 to 3294 kPa
Unit
kPa

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.

Request engine run time SEQUOIA_REQ_ENG_RUN_TIME

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 s
Unit
s

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Request warm-up SEQUOIA_REQ_WARM_UP

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 89 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Requested engine torque SEQUOIA_REQ_ENG_TQ

  • Request21 49
  • Service 21PID 49
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Rough idle, cylinder 1 SEQUOIA_ROUGH_IDLE_CYL_1Confirmed

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 7 of the reply, 8 bits.

0x01 = 1 → 1 °

Formula
val
Range
0 to 255 °
Unit
°

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Rough idle, cylinder 2 SEQUOIA_ROUGH_IDLE_CYL_2Confirmed

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → 0 °

Formula
val
Range
0 to 255 °
Unit
°

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Rough idle, cylinder 3 SEQUOIA_ROUGH_IDLE_CYL_3Confirmed

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

0x3F = 63 → 63 °

Formula
val
Range
0 to 255 °
Unit
°

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Rough idle, cylinder 4 SEQUOIA_ROUGH_IDLE_CYL_4Confirmed

  • Request22 10 84
  • Service 22DID 1084
  • Module700 → 708
  • Every1 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 24 to 31 of the reply, 8 bits.

0x00 = 0 → 0 °

Formula
val
Range
0 to 255 °
Unit
°

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.

Short term fuel trim, bank 1 SEQUOIA_SHORT_FT_B1Confirmed

Pelican can show this parameter as the short term fuel trim.

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Short term fuel trim, bank 2 SEQUOIA_SHORT_FT_B2Confirmed

Pelican can show this parameter as the short term fuel trim.

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 200 ÷ 256 − 100)
Range
-100 to 99.21 %
Unit
%

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Starter relay on SEQUOIA_STARTER_RELAY_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 47 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Stroke open SEQUOIA_STROKE_OPENConfirmed

  • Request21 BE
  • Service 21PID BE
  • Module7B0 → 7B8
  • Every1 s
  • Testing for 2000 to 2017, 2019, 2021 to 2026

Bit 10 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2023 to 2025.

Synchronize stroke sensor position SEQUOIA_SYNCHRONIZE_STROKE

  • Request22 16 34
  • Service 22DID 1634
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 256 ÷ 65535)
Range
0 to 256 mm
Unit
mm

In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.

System guard on SEQUOIA_SYSTEM_GUARD_ON

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 144 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle fully close learn SEQUOIA_THROTTLE_FULLY_CLOSE

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle idle position on SEQUOIA_THROTTLE_IDLE_POS_ON

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 149 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle motor current SEQUOIA_THROTTLE_MOTOR

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 19.9 A
Unit
A

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle motor duty SEQUOIA_THROTTLE_MOTOR_DUTYConfirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 144 to 151 of the reply, 8 bits.

0x29 = 41 → (41 × 100 ÷ 255) = 16.078431 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Throttle motor duty SEQUOIA_THROTTLE_MOTOR_DUTY_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 152 to 159 of the reply, 8 bits.

0x29 = 41 → (41 × 100 ÷ 255) = 16.078431 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Throttle motor duty, close SEQUOIA_THROTTLE_MOTOR_DUTY_CLOSE

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle motor duty, open SEQUOIA_THROTTLE_MOTOR_DUTY_OPEN

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle position SEQUOIA_THROTTLE_21

  • Request21 11
  • Service 21PID 11
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle position command SEQUOIA_THROTTLE_POS_COMMAND

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle position, number 1 SEQUOIA_THROTTLE_POS_NUMBER_1

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle position, number 2 SEQUOIA_THROTTLE_POS_NUMBER_2

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle require position SEQUOIA_THROTTLE_REQUIRE_POS

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle sensor open position 1 SEQUOIA_THROTTLE_SENS_OPEN_1

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle sensor open position 2 SEQUOIA_THROTTLE_SENS_OPEN_2

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 5 ÷ 256)
Range
0 to 4.98 V
Unit
V

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Throttle sensor position SEQUOIA_THROTTLE_SENSOR_POSITIONConfirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 104 to 111 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Throttle sensor position SEQUOIA_THROTTLE_SENSOR_POSITION_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 112 to 119 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Throttle sensor voltage, 1 SEQUOIA_THROTTLE_SENSOR_VOLTConfirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 112 to 119 of the reply, 8 bits.

0x29 = 41 → (41 × 100 ÷ 255) = 16.078431 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Throttle sensor voltage, 1 SEQUOIA_THROTTLE_SENSOR_VOLT_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 120 to 127 of the reply, 8 bits.

0x29 = 41 → (41 × 100 ÷ 255) = 16.078431 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Throttle sensor voltage, 2 SEQUOIA_THROTTLE_SENSOR_2_VOLTConfirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 120 to 127 of the reply, 8 bits.

0x7A = 122 → (122 × 100 ÷ 255) = 47.843137 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Throttle sensor voltage, 2 SEQUOIA_THROTTLE_SENSOR_2_VOLT_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 128 to 135 of the reply, 8 bits.

0x7A = 122 → (122 × 100 ÷ 255) = 47.843137 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Time since DTCs cleared SEQUOIA_TIME_SINCE_DTC_CLEAREDConfirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 176 to 191 of the reply, 16 bits.

0x006F = 111 → 111 min

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Time since DTCs cleared SEQUOIA_TIME_SINCE_DTC_CLEARED_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 184 to 199 of the reply, 16 bits.

0x1147 = 4423 → 4,423 min

Formula
val
Range
0 to 65535 min
Unit
min

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Total fuel trim, bank 1 SEQUOIA_TOT_FT_1

  • Request21 3C
  • Service 21PID 3C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 100 ÷ 256 − 50)
Range
-50 to 49.6 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Transaxle oil temperature SEQUOIA_TRANSAXLE_OIL_TConfirmed

  • Request22 10 40
  • Service 22DID 1040
  • Module7D2 → 7DA
  • Every1 s
  • Testing for 2026

Example reply from a 2025 Toyota Sequoia.

Bits 16 to 23 of the reply, 8 bits.

0x86 = 134 → (134 − 40) = 94 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Transmission fluid pan temperature SEQUOIA_TF1_PANConfirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 16 27
  • Service 22DID 1627
  • Module701 → 709
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x4A00 = 18944 → (18944 × 0.00703125 − 40) = 93.2 °F

Formula
(val × 0.00703125 − 40)
Range
-40 to 350 °F
Unit
°F

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Transmission fluid post-converter temperature SEQUOIA_TF2_CONV

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 16 28
  • Service 22DID 1628
  • Module701 → 709
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.00703125 − 40)
Range
-40 to 350 °F
Unit
°F

In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.

Transmission fluid temperature SEQUOIA_ATF_TEMP_700

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 16 38
  • Service 22DID 1638
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2011, 2013, 2018, 2020, 2023 to 2025.

Transmission output shaft speed SEQUOIA_TRANS_OUT_RPM

  • Request21 BD
  • Service 21PID BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Turbine speed SEQUOIA_SPD_NT

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 rpm
Unit
rpm

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Valvematic current angle SEQUOIA_VALVEMATIC_CURRENT

  • Request21 31
  • Service 21PID 31
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 512)
Range
0 to 639.9 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Valvematic, target angle SEQUOIA_VALVEMATIC_TGT_ANG

  • Request21 3A
  • Service 21PID 3A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 512)
Range
0 to 639.9 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Variable valve timing aim angle 1 SEQUOIA_VARIABLE_VLV_TIM_AIM_1

  • Request21 44
  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1333 ÷ 218450)
Range
0 to 399 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Variable valve timing change angle 1 SEQUOIA_VARIABLE_VLV_TIM_1

  • Request21 44
  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val × 0.0097642481)
Range
0 to 639 °
Unit
°

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Variable valve timing control status 1 on SEQUOIA_VARIABLE_VLV_TIM_1_ON

  • Request21 39
  • Service 21PID 39
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bit 22 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Variable valve timing oil control valve duty 1 SEQUOIA_VARIABLE_VLV_TIM_OIL_1

  • Request21 44
  • Service 21PID 44
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 0.0061020829)
Range
0 to 399 %
Unit
%

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Variable valve timing oil temperature SEQUOIA_VVTOTConfirmed

  • Request21 51
  • Service 21PID 51
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2023 to 2025.

Variable valve timing opening angle bank 1 SEQUOIA_VVT_IE_OPENING_ANGLE_BANK_1

  • Request22 28 43
  • Service 22DID 2843
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.

Vehicle speed SEQUOIA_VSS_21

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Vehicle speed sensor test result, incomplete SEQUOIA_SPD_TEST_RESULT

  • Request21 E3
  • Service 21PID E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Number

In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.

Warm-up cycles since DTCs cleared SEQUOIA_WARMUP_CYCLES_DTC_CLEAREDConfirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016

Example reply from a 2013 Toyota Sequoia.

Bits 160 to 167 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.

Warm-up cycles since DTCs cleared SEQUOIA_WARMUP_CYCLES_DTC_CLEARED_V2Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019, 2021 to 2026

Example reply from a 2020 Toyota Sequoia.

Bits 168 to 175 of the reply, 8 bits.

0x15 = 21 → 21

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.

Engine › Catalyst

Catalyst temperature, bank 1 sensor 1 SEQUOIA_CAT_T_11Confirmed

  • Request22 1F 3C
  • Service 22DID 1F3C
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x0305 = 773 → (773 ÷ 10 − 40) = 37.3 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2008 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.

Catalyst temperature, bank 1 sensor 2 SEQUOIA_CAT_T_12Confirmed

  • Request22 1F 3E
  • Service 22DID 1F3E
  • Module700 → 708
  • Every5 s
  • Testing for 2000 to 2022, 2026

Example reply from a 2025 Toyota Sequoia.

Bits 0 to 15 of the reply, 16 bits.

0x02D9 = 729 → (729 ÷ 10 − 40) = 32.9 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2010, 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2011, 2013, 2018, 2020.

Engine › Misfires

All cylinders misfire count SEQUOIA_ALL_CYLINDERS_MISFIRE_CNTConfirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Cylinder #1 misfire count SEQUOIA_CYL1_MISFIRE_CNTConfirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Cylinder #2 misfire count SEQUOIA_CYL2_MISFIRE_CNTConfirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Cylinder #3 misfire count SEQUOIA_CYL3_MISFIRE_CNTConfirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Cylinder #4 misfire count SEQUOIA_CYL4_MISFIRE_CNTConfirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Misfire load SEQUOIA_MISFIRE_LOAD_7E0Confirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 4 ÷ 256)
Range
0 to 3.98
Unit
Number

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Misfire margin SEQUOIA_MISFIRE_MARGIN_7E0Confirmed

  • Request21 45
  • Service 21PID 45
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026

Bits 80 to 87 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127 %
Unit
%

Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.

Engine › OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2023. Supported for 2006 to 2007, 2013, 2020, 2024 to 2025.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2023. Supported for 2006 to 2007, 2013, 2020, 2024 to 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.