DTC parameters
The Toyota Sequoia has 24 DTC parameters.
● Confirmed◆ In testing○ Supported× Not supported
2nd air monitor available? SEQUOIA_2ND_AIR_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
2nd air monitor incomplete? SEQUOIA_2ND_AIR_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
A/C monitor available? SEQUOIA_A_C_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 19 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
A/C monitor incomplete? SEQUOIA_A_C_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
Catalyst monitor available? SEQUOIA_CATALYST_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
Catalyst monitor incomplete? SEQUOIA_CATALYST_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
Complete parts monitor available? SEQUOIA_COMPLETE_PARTS_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
01 31 - Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2006 to 2007, 2011, 2013, 2023. Supported for 2005, 2020, 2024 to 2025.
EGR/VVT monitor available? SEQUOIA_EGR_VVT_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
EGR/VVT monitor incomplete? SEQUOIA_EGR_VVT_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
EVAP monitor available? SEQUOIA_EVAP_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
EVAP monitor_icmpl SEQUOIA_EVAP_MONITOR_ICMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
Fuel system monitor available? SEQUOIA_FUEL_SYSTEM_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
Heated catalyst monitor available? SEQUOIA_HEATED_CATALYST_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
Heated catalyst monitor incomplete? SEQUOIA_HEATED_CATALYST_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
MIL SEQUOIA_MILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2006, 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.
MIL ON run distance SEQUOIA_MILON_RUN_DISTANCEConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
Misfire monitor available? SEQUOIA_MISFIRE_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
Number of emission DTC SEQUOIA_NUMBER_OF_EMISSION_DTCConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bits 1 to 7 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127
- Unit
- Number
Confirmed for 2006, 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.
O2S heater monitor available? SEQUOIA_O2S_A_FS_HEATER_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
O2S heater monitor incomplete? SEQUOIA_O2S_A_FS_HEATER_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
O2S monitor available? SEQUOIA_O2S_A_FS_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 18 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
O2S monitor incomplete? SEQUOIA_O2S_A_FS_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.
Running time from MIL ON SEQUOIA_RUNNING_TIME_FROM_MIL_ONConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2026
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2006. Not supported for 2018, 2023 to 2025.