+BM voltage SEQUOIA_BM_V
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.
1st turbocharger outlet pressure, control valve SEQUOIA_1ST_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
2nd turbocharger outlet pressure SEQUOIA_2ND_TRUBOCHARGER_OUTLET_P
- Request
22 11 AF - Service 22
DID 11AF - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
2nd turbocharger outlet pressure, control valve SEQUOIA_2ND_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
12V battery current SEQUOIA_12V_CConfirmed
- Request
22 15 F7 - Service 22
DID 15F7 - Module
7D2 → 7DA - Every
500 ms - Testing for 2026
Example reply from a 2025 Toyota Sequoia.
Bits 0 to 15 of the reply, 16 bits.
0x6BF0 = 27632 → (27632 × 38.147 ÷ 10000 − 125) = -19.59221 A
- Formula
(val × 38.147 ÷ 10000 − 125)- Range
- -125 to 124 A
- Unit
- A
Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.
12V battery temperature SEQUOIA_12V_TConfirmed
- Request
22 15 F8 - Service 22
DID 15F8 - Module
7D2 → 7DA - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Sequoia.
Bits 0 to 15 of the reply, 16 bits.
0x027D = 637 → (637 ÷ 10 − 40) = 23.7 °C
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.
12V battery voltage SEQUOIA_12V_V_V2Confirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 15 EE - Service 22
DID 15EE - Module
7D2 → 7DA - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Sequoia.
Bits 0 to 7 of the reply, 8 bits.
0x28 = 40 → (40 × 0.31448 + 0.0125) = 12.5917 V
- Formula
(val × 0.31448 + 0.0125)- Range
- 0 to 80.2 V
- Unit
- V
Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006, 2011, 2013, 2018, 2020.
12V battery voltage before system main relay SEQUOIA_12V_BAT_V_BEFORE_SMRConfirmed
- Request
22 10 7E - Service 22
DID 107E - Module
7D2 → 7DA - Every
5 s - Testing for 2024 to 2026
Example reply from a 2023 Toyota Sequoia.
Bits 0 to 7 of the reply, 8 bits.
0x24 = 36 → (36 × 61 ÷ 50000 + 11.25) = 11.29392 V
- Formula
(val × 61 ÷ 50000 + 11.25)- Range
- 0 to 11.56 V
- Unit
- V
Confirmed for 2023. In testing for 2024 to 2026.
12V battery voltage smoothed SEQUOIA_12V_BAT_V_SMOOTHEDConfirmed
- Request
22 1F 42 - Service 22
DID 1F42 - Module
7D2 → 7DA - Every
5 s - Testing for 2024 to 2026
Example reply from a 2023 Toyota Sequoia.
Bits 0 to 15 of the reply, 16 bits.
0x30FB = 12539 → (12539 ÷ 1000) = 12.539 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
Confirmed for 2023. In testing for 2024 to 2026.
Aux battery voltage SEQUOIA_AUX_BAT_VConfirmed
- Request
22 10 02 - Service 22
DID 1002 - Module
7D2 → 7DA - Every
5 s - Testing for 2024 to 2026
Example reply from a 2023 Toyota Sequoia.
Bits 0 to 15 of the reply, 16 bits.
0x23C0 = 9152 → (9152 × 61 ÷ 50000) = 11.16544 V
- Formula
(val × 61 ÷ 50000)- Range
- 0 to 79.95 V
- Unit
- V
Confirmed for 2023. In testing for 2024 to 2026.
Aux. battery capacity after IG OFF SEQUOIA_AUX_BAT_CAP_AFTER_IG_OFF
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
Aux. battery capacity after IG ON SEQUOIA_AUX_BAT_CAP_AFTER_IG_ON
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
Auxiliary battery current SEQUOIA_AUXILIARY_BATConfirmed
- Request
22 18 02 - Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing for 2024 to 2026
Example reply from a 2023 Toyota Sequoia.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 2525 ÷ 13107 − 12500) = -12,500 A
- Formula
(val × 2525 ÷ 13107 − 12500)- Range
- -12500 to -12451 A
- Unit
- A
Confirmed for 2023. In testing for 2024 to 2026.
Battery current SEQUOIA_BAT_CURRENT
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 50 ÷ 13107 − 125)- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.
Battery current SEQUOIA_BAT_CURRENT_700
- Request
22 15 F7 - Service 22
DID 15F7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 49 ÷ 12850 − 125)- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
Battery status of full charge SEQUOIA_BAT_STAT_FULL_CHG
- Request
22 15 E5 - Service 22
DID 15E5 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 255 ÷ 2)- Range
- 0 to 32512.5 Ah
- Unit
- Ah
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
Battery temperature SEQUOIA_BAT_T
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 6513.5 °C
- Unit
- °C
In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.
Battery temperature SEQUOIA_BAT_T_700
- Request
22 15 F8 - Service 22
DID 15F8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
Battery temperature SEQUOIA_BAT_T_700_2
- Request
22 1F F8 - Service 22
DID 1FF8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 40)- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
Battery voltage SEQUOIA_12V_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 02 - Service 22
DID 1002 - Module
700 → 708 - Every
5 s - Testing for 2000 to 2022, 2026
Example reply from a 2025 Toyota Sequoia.
Bits 0 to 15 of the reply, 16 bits.
0x27EC = 10220 → (10220 × 12.207 ÷ 10000) = 12.475554 V
- Formula
(val × 12.207 ÷ 10000)- Range
- 0 to 79 V
- Unit
- V
Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.
Battery voltage SEQUOIA_BAT_VConfirmed
- Request
21 13 - Service 21
PID 13 - Module
7C0 → 7C8 - Every
5 s - Testing for 2000 to 2012, 2014 to 2019, 2021 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2013, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.
Battery voltage SEQUOIA_BATTERY_VOLTAGE_7E0Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2000 to 2005, 2007 to 2012, 2014 to 2016
Example reply from a 2013 Toyota Sequoia.
Bits 192 to 207 of the reply, 16 bits.
0x3393 = 13203 → (13203 ÷ 1000) = 13.203 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2013. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2016. Supported for 2006.
Battery voltage SEQUOIA_BATTERY_VOLTAGE_7E0_V2Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2019, 2021 to 2026
Example reply from a 2020 Toyota Sequoia.
Bits 200 to 215 of the reply, 16 bits.
0x35DD = 13789 → (13789 ÷ 1000) = 13.789 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2020. In testing for 2019, 2021 to 2022, 2026. Not supported for 2018, 2023 to 2025.
Charge contactor current SEQUOIA_SCC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.
Charging integrated current of aux. battery SEQUOIA_CHG_INTEGRATED
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
Dark current of battery SEQUOIA_DARK_CURRENT_BAT
- Request
22 15 E7 - Service 22
DID 15E7 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
DC-DC converter high side voltage SEQUOIA_DC_DC_CONV_HIGH_SIDE_V
- Request
22 11 1E - Service 22
DID 111E - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1220703 ÷ 10000000)- Range
- 0 to 7999 V
- Unit
- V
In testing for 2024 to 2026. Not supported for 2023.
DC-DC converter low side voltage SEQUOIA_DC_DC_CONV_LOW_SIDE_V
- Request
22 11 1D - Service 22
DID 111D - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1953 ÷ 25000)- Range
- 0 to 19.92 V
- Unit
- V
In testing for 2024 to 2026. Not supported for 2023.
DC-DC converter, target voltage before charging SEQUOIA_DC_DC_CONV_TGT_V
- Request
22 11 1F - Service 22
DID 111F - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1220703 ÷ 10000000)- Range
- 0 to 7999 V
- Unit
- V
In testing for 2024 to 2026. Not supported for 2023.
Discharging integrated current of aux. battery SEQUOIA_DISCHARGING
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
Distance since last battery cable disconnection SEQUOIA_DIST_SINCE_BAT_DISCConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
700 → 708 - Every
30 s - Testing for 2000 to 2022, 2026
Example reply from a 2025 Toyota Sequoia.
Bits 0 to 15 of the reply, 16 bits.
0x1BED = 7149 → 7,149 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.
HV battery charge voltage SEQUOIA_HVBAT_CHRG_V
- Request
22 16 09 - Service 22
DID 1609 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 V
- Unit
- V
In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.
HV battery charge, maximum SEQUOIA_HVBAT_SOC_MAXConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 2026
Example reply from a 2025 Toyota Sequoia.
Bits 8 to 15 of the reply, 8 bits.
0x55 = 85 → (85 ÷ 2) = 42.5 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.
HV battery charge, minimum SEQUOIA_HVBAT_SOC_MINConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 2026
Example reply from a 2025 Toyota Sequoia.
Bits 16 to 23 of the reply, 8 bits.
0x4B = 75 → (75 ÷ 2) = 37.5 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.
HV battery current SEQUOIA_HVBAT_CConfirmed
Pelican can show this parameter as the traction battery current.
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 2026
Example reply from a 2025 Toyota Sequoia.
Bits 32 to 47 of the reply, 16 bits. The value is signed.
0x05FC = 1532 → (1532 ÷ 10) = 153.2 A
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.
HV battery maximum temperature SEQUOIA_HVBAT_MAX_T
- Request
22 18 29 - Service 22
DID 1829 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.
HV battery minimum temperature SEQUOIA_HVBAT_MIN_T
- Request
22 18 2A - Service 22
DID 182A - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020, 2023 to 2025.
HV battery voltage SEQUOIA_HVBAT_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 2026
Example reply from a 2025 Toyota Sequoia.
Bits 16 to 31 of the reply, 16 bits.
0x4140 = 16704 → (16704 × 156.25 ÷ 10000) = 261 V
- Formula
(val × 156.25 ÷ 10000)- Range
- 0 to 1023 V
- Unit
- V
Confirmed for 2023 to 2025. In testing for 2026. Not supported for 2006 to 2007, 2011, 2013, 2018, 2020.
Hybrid battery 1 fan SEQUOIA_HYBRID_BAT_1_FANConfirmed
- Request
22 18 02 - Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing for 2024 to 2026
Example reply from a 2023 Toyota Sequoia.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2) = 0 %
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
Confirmed for 2023. In testing for 2024 to 2026.
Hybrid battery temperature 1 SEQUOIA_HYBRID_BAT_T_1Confirmed
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing for 2024 to 2026
Example reply from a 2023 Toyota Sequoia.
Bits 0 to 15 of the reply, 16 bits.
0x4D5C = 19804 → (19804 × 458 ÷ 65535 − 58) = 80.402869 °F
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
Confirmed for 2023. In testing for 2024 to 2026.
Hybrid battery temperature 2 SEQUOIA_HYBRID_BAT_T_2Confirmed
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing for 2024 to 2026
Example reply from a 2023 Toyota Sequoia.
Bits 16 to 23 of the reply, 8 bits.
0x4F = 79 → (79 × 9 ÷ 5 − 58) = 84.2 °F
- Formula
(val × 9 ÷ 5 − 58)- Range
- -58 to 401 °F
- Unit
- °F
Confirmed for 2023. In testing for 2024 to 2026.
Hybrid battery temperature 3 SEQUOIA_HYBRID_BAT_T_3Confirmed
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing for 2024 to 2026
Example reply from a 2023 Toyota Sequoia.
Bits 32 to 47 of the reply, 16 bits.
0x5078 = 20600 → (20600 × 458 ÷ 65535 − 58) = 85.96582 °F
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
Confirmed for 2023. In testing for 2024 to 2026.
Initial engine battery voltage lower limit SEQUOIA_INITIAL_ENG_BAT_V_LO
- Request
22 15 F6 - Service 22
DID 15F6 - Module
700 → 708 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
Main connector solenoid current SEQUOIA_SMC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.
Main relay a, solenoid current SEQUOIA_SLA_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.
Main relay r solenoid current SEQUOIA_SLR_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.
Output speed sensor voltage SEQUOIA_NOUT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.
Regenerative braking cooperation SEQUOIA_REGEN_COOPERATION
- Request
21 58 - Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.
Regenerative operation SEQUOIA_FR_REGEN_OPERATION
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.
Regenerative request SEQUOIA_FR_REGEN_REQUEST
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.
Relay control solenoid current SEQUOIA_SRC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.
Service contactor solenoid current SEQUOIA_SSC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2000 to 2005, 2007 to 2012, 2014 to 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2020, 2023 to 2025.
Sleep time of battery sensor SEQUOIA_SLEEP_TIME_BATSENS
- Request
22 15 F0 - Service 22
DID 15F0 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 h
- Unit
- h
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.
State of charge SEQUOIA_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 1F 5B - Service 22
DID 1F5B - Module
7D2 → 7DA - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Sequoia.
Bits 0 to 7 of the reply, 8 bits.
0x5A = 90 → (90 × 100 ÷ 255) = 35.294118 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023 to 2025. In testing for 2026.
Turbine speed sensor voltage SEQUOIA_NT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2000 to 2022, 2024 to 2026. Not supported for 2023.
Vh-voltage after boosting SEQUOIA_VH_V_AFTER_BOOSTINGConfirmed
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing for 2024 to 2026
Example reply from a 2023 Toyota Sequoia.
Bits 16 to 31 of the reply, 16 bits.
0x023E = 574 → (574 ÷ 2) = 287 V
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
Confirmed for 2023. In testing for 2024 to 2026.
Vl-voltage before boosting SEQUOIA_VL_V_BEFORE_BOOSTINGConfirmed
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing for 2024 to 2026
Example reply from a 2023 Toyota Sequoia.
Bits 0 to 15 of the reply, 16 bits.
0x023E = 574 → (574 ÷ 2) = 287 V
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
Confirmed for 2023. In testing for 2024 to 2026.
Voltage of battery sensor SEQUOIA_V_BATSENS
- Request
22 15 EE - Service 22
DID 15EE - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13333 ÷ 10922500)- Range
- 0 to 79.9979 V
- Unit
- V
In testing for 2000 to 2022, 2024, 2026. Not supported for 2023, 2025.