The Toyota Sequoia has 17 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
Adjusted ambient temperature SEQUOIA_ADJUSTED_AMBIENT_TConfirmed
- Request
21 3D - Service 21
PID 3D - Module
7C4 → 7CC - Every
5 s - Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 81.6 ÷ 255 − 30.8)- Range
- -30.8 to 50.8 °C
- Unit
- °C
Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.
Air inlet damper actual pulse SEQUOIA_AIR_INLET_DAMPER_ACTUAL_PULSE
- Request
21 44 - Service 21
PID 44 - Module
7C4 → 7CC - Every
1 s - Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2013, 2018, 2020. Not supported for 2006, 2023 to 2025.
Air inlet damper target pulse SEQUOIA_AIR_INLET_DAMPER_TARGET_PULSEConfirmed
- Request
21 44 - Service 21
PID 44 - Module
7C4 → 7CC - Every
1 s - Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.
Air outlet servo actual pulse, driver SEQUOIA_AIR_OUTLET_SERVO_ACTU_PULSE_D
- Request
21 43 - Service 21
PID 43 - Module
7C4 → 7CC - Every
1 s - Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Supported for 2013, 2018, 2020. Not supported for 2006, 2023 to 2025.
Air outlet servo pulse, driver SEQUOIA_AIR_OUTLET_SERVO_PULSE_DConfirmed
- Request
21 43 - Service 21
PID 43 - Module
7C4 → 7CC - Every
1 s - Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.
Ambient air temperature AATSAE J1979Confirmed
- Request
01 46 - Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2011. Supported for 2023, 2025.
Ambient air temperature SEQUOIA_AAT_7C4Confirmed
- Request
21 22 - Service 21
PID 22 - Module
7C4 → 7CC - Every
5 s - Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 89.25 ÷ 255 − 23.3)- Range
- -23.3 to 65.95 °C
- Unit
- °C
Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.
Ambient temperature SEQUOIA_AMBIENT_TConfirmed
- Request
22 1F 46 - Service 22
DID 1F46 - Module
700 → 708 - Every
5 s - Testing for 2000 to 2022, 2026
Example reply from a 2025 Toyota Sequoia.
Bits 0 to 7 of the reply, 8 bits.
0x2F = 47 → (47 − 40) = 7 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023 to 2025. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020.
Blower motor speed level SEQUOIA_BLOWER_MOTOR_SPEED_LEVELConfirmed
- Request
21 3C - Service 21
PID 3C - Module
7C4 → 7CC - Every
5 s - Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.
Cabin temperature SEQUOIA_CABIN_TConfirmed
- Request
21 21 - Service 21
PID 21 - Module
7C4 → 7CC - Every
5 s - Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 63.75 ÷ 255 − 6.5)- Range
- -6.5 to 57.25 °C
- Unit
- °C
Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.
Communication with air conditioner SEQUOIA_COMM_WITH_AIR_CONDITIONERConfirmed
- Request
21 24 - Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing for 2000 to 2005, 2007 to 2026
Example reply from a 2006 Toyota Sequoia.
Bit 5 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2006. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2013, 2018, 2020, 2023 to 2025.
Communication with HV SEQUOIA_COMMUNICATION_WITH_HVConfirmed
- Request
21 24 - Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing for 2000 to 2005, 2007 to 2026
Example reply from a 2006 Toyota Sequoia.
Bit 2 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2006. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2013, 2018, 2020, 2023 to 2025.
Communication with valvematic SEQUOIA_COMM_WITH_VALVEMATIC_COMMConfirmed
- Request
21 24 - Service 21
PID 24 - Module
7E0 → 7E8 - Every
5 s - Testing for 2000 to 2005, 2007 to 2026
Example reply from a 2006 Toyota Sequoia.
Bit 6 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2006. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2013, 2018, 2020, 2023 to 2025.
Evaporator fin thermistor SEQUOIA_EVAP_FIN_THERMISTORConfirmed
- Request
21 4B - Service 21
PID 4B - Module
7C4 → 7CC - Every
5 s - Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 89.25 ÷ 255 − 29.7)- Range
- -29.7 to 59.55 °C
- Unit
- °C
Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.
Evaporator target temperature SEQUOIA_EVAP_TARGET_T
- Request
21 4C - Service 21
PID 4C - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67
- Unit
- Number
In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2013, 2018, 2020, 2023 to 2025.
Set temperature, driver side SEQUOIA_T_DRIVERConfirmed
- Request
21 29 - Service 21
PID 29 - Module
7C4 → 7CC - Every
5 s - Testing for 2000 to 2012, 2014 to 2017, 2019, 2021 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
Confirmed for 2013, 2018, 2020. In testing for 2000 to 2005, 2007 to 2012, 2014 to 2017, 2019, 2021 to 2022, 2026. Not supported for 2006, 2023 to 2025.
Solar sensor, driver side SEQUOIA_SOLAR_DRIVERConfirmed
- Request
21 24 - Service 21
PID 24 - Module
7C4 → 7CC - Every
1 s - Testing for 2000 to 2012, 2014 to 2026
Example reply from a 2013 Toyota Sequoia.
Bits 0 to 7 of the reply, 8 bits.
0x09 = 9 → 9
- Formula
val- Range
- 0 to 255
- Unit
- Number