Connectable parameters
The Mitsubishi Triton has 14 Connectables, parameters that Pelican can monitor automatically.
● Confirmed◆ In testing○ Supported× Not supported
Fuel tank level
Fuel level TRITON_FLIConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
21 A3 - Service 21
PID A3 - Module
6A0 → 514 - Every
30 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 16 to 23 of the reply, 8 bits.
0x1D = 29 → (29 − 16) = 13 %
- Formula
(val − 16)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Speed
Vehicle speed TRITON_AC_VSSConfirmed
Pelican can show this parameter as the speed.
- Request
21 13 - Service 21
PID 13 - Module
688 → 511 - Every
250 ms - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 24 to 39 of the reply, 16 bits.
0x0000 = 0 → 0 km/h
- Formula
val- Range
- 0 to 250 km/h
- Unit
- km/h
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Vehicle speed TRITON_MPI_VSSConfirmed
Pelican can show this parameter as the speed.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 8 to 15 of the reply, 8 bits.
0x00 = 0 → (0 × 2) = 0 km/h
- Formula
(val × 2)- Range
- 0 to 200 km/h
- Unit
- km/h
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Odometer
Odometer TRITON_ODOConfirmed
Pelican can show this parameter as the odometer.
- Request
21 AD - Service 21
PID AD - Module
6A0 → 514 - Every
30 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 0 to 23 of the reply, 24 bits.
0x007E01 = 32257 → 32,257 km
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Distance since trouble codes were cleared
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
01 31 - Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2018. Supported for 2010, 2013, 2015, 2019, 2022 to 2024.
Engine coolant temperature
Engine coolant temperature TRITON_AC_ECTConfirmed
Pelican can show this parameter as the engine coolant temperature.
- Request
21 10 - Service 21
PID 10 - Module
688 → 511 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 32 to 39 of the reply, 8 bits.
0x00 = 0 → (0 − 40) = -40 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Engine coolant temperature TRITON_MPI_ECTConfirmed
Pelican can show this parameter as the engine coolant temperature.
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 8 to 15 of the reply, 8 bits.
0x55 = 85 → (85 − 40) = 45 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Engine load
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2010, 2013, 2015, 2019, 2022 to 2024.
Engine load TRITON_MPI_ENGINE_LOAD
Pelican can show this parameter as the engine load.
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2017, 2019 to 2026. Supported for 2018.
Engine speed
Engine RPM TRITON_AC_RPMConfirmed
Pelican can show this parameter as the engine speed.
- Request
21 13 - Service 21
PID 13 - Module
688 → 511 - Every
250 ms - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 8 to 23 of the reply, 16 bits.
0x0000 = 0 → 0 rpm
- Formula
val- Range
- 0 to 7000 rpm
- Unit
- rpm
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Mass air flow
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2018. Supported for 2010, 2013, 2015, 2019, 2022 to 2024.
Starter battery voltage
Battery voltage TRITON_MPI_BATTERY_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 0 to 7 of the reply, 8 bits.
0xAF = 175 → (175 × 18 ÷ 255) = 12.352941 V
- Formula
(val × 18 ÷ 255)- Range
- 0 to 18 V
- Unit
- V
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Throttle position
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Request
01 11 - Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2010, 2013, 2015, 2019, 2022 to 2024.
Transmission fluid temperature
Transmission fluid temperature TRITON_ATF_TConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 02 - Service 21
PID 02 - Module
7E1 → 7E9 - Every
250 ms - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bits 40 to 47 of the reply, 8 bits.
0x4D = 77 → (77 − 40) = 37 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.