Mitsubishi Triton

Climate parameters

The Mitsubishi Triton has 30 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine coolant temperature TRITON_AC_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request21 10
  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 32 to 39 of the reply, 8 bits.

0x00 = 0 → (0 − 40) = -40 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor drive flag TRITON_AC_A_C_COMPRESSOR_DRIVE_FLAGConfirmed

  • Request21 70
  • Service 21PID 70
  • Module688 → 511
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 7 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

A/C compressor drive request TRITON_AC_A_C_COMPRESSOR_DRIVE_REQUESTConfirmed

  • Request21 23
  • Service 21PID 23
  • Module688 → 511
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 7 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Air conditioning switch TRITON_AC_SWITCHConfirmed

  • Request21 23
  • Service 21PID 23
  • Module688 → 511
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 6 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Air temperature sensor TRITON_AC_AIR_THERMO_SNSConfirmed

  • Request21 10
  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 4 − 16) = -16 °C

Formula
(val ÷ 4 − 16)
Range
-16 to 47.75 °C
Unit
°C

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Ambient air temperature TRITON_AC_AATConfirmed

  • Request21 11
  • Service 21PID 11
  • Module688 → 511
  • Every5 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 2 − 40) = -40 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Compressor ON/OFF count TRITON_AC_COMPRESSOR_ON_OFF_COUNTConfirmed

  • Request21 80
  • Service 21PID 80
  • Module688 → 511
  • Every3600 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 47 of the reply, 24 bits.

0x04C015 = 311317 → 311,317

Formula
val
Range
0 to 16777215
Unit
Number

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Compressor work time TRITON_AC_COMPRESSOR_WORK_TIMEConfirmed

  • Request21 81
  • Service 21PID 81
  • Module688 → 511
  • Every3600 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 128 to 151 of the reply, 24 bits.

0x06192C = 399660 → (399660 × 5) = 1,998,300

Formula
(val × 5)
Range
0 to 83886075
Unit
Number

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Conditioner work time TRITON_AC_CONDITIONER_WORK_TIMEConfirmed

  • Request21 81
  • Service 21PID 81
  • Module688 → 511
  • Every3600 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 104 to 127 of the reply, 24 bits.

0x14C869 = 1362025 → (1362025 × 5) = 6,810,125

Formula
(val × 5)
Range
0 to 83886075
Unit
Number

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Corrected driver temperature setting TRITON_AC_DRIVER_T_CORRConfirmed

  • Request21 34
  • Service 21PID 34
  • Module688 → 511
  • Every5 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 2) = 0 °C

Formula
(val ÷ 2)
Range
0 to 50 °C
Unit
°C

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Corrected passenger temperature setting TRITON_AC_PASSENGER_T_CORRConfirmed

  • Request21 34
  • Service 21PID 34
  • Module688 → 511
  • Every5 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 31 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 2) = 0 °C

Formula
(val ÷ 2)
Range
0 to 50 °C
Unit
°C

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Driver side output speed TRITON_AC_OUTPUT_VSS_DRConfirmed

  • Request21 22
  • Service 21PID 22
  • Module688 → 511
  • Every5 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 2) = 0

Formula
(val ÷ 2)
Range
0 to 16
Unit
Number

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Driver temperature setting TRITON_AC_DRIVER_TConfirmed

  • Request21 34
  • Service 21PID 34
  • Module688 → 511
  • Every5 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 2) = 0 °C

Formula
(val ÷ 2)
Range
0 to 50 °C
Unit
°C

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Engine coolant temperature TRITON_AC_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request21 10
  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 32 to 39 of the reply, 8 bits.

0x00 = 0 → (0 − 40) = -40 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Engine RPM TRITON_AC_RPMConfirmed

Pelican can show this parameter as the engine speed.

  • Request21 13
  • Service 21PID 13
  • Module688 → 511
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 23 of the reply, 16 bits.

0x0000 = 0 → 0 rpm

Formula
val
Range
0 to 7000 rpm
Unit
rpm

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Fan M1 work time TRITON_AC_FAN_M1_WORK_TIMEConfirmed

  • Request21 83
  • Service 21PID 83
  • Module688 → 511
  • Every3600 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 40 to 63 of the reply, 24 bits.

0x06E7F3 = 452595 → (452595 × 5) = 2,262,975

Formula
(val × 5)
Range
0 to 83886075
Unit
Number

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Fan M2 work time TRITON_AC_FAN_M2_WORK_TIMEConfirmed

  • Request21 83
  • Service 21PID 83
  • Module688 → 511
  • Every3600 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 64 to 87 of the reply, 24 bits.

0x023BF7 = 146423 → (146423 × 5) = 732,115

Formula
(val × 5)
Range
0 to 83886075
Unit
Number

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Idle up request TRITON_AC_IDLE_UP_REQUESTConfirmed

  • Request21 23
  • Service 21PID 23
  • Module688 → 511
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → 0 rpm

Formula
val
Range
0 to 255 rpm
Unit
rpm

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Interior temperature TRITON_AC_INTERIOR_TConfirmed

  • Request21 10
  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 4 − 16) = -16 °C

Formula
(val ÷ 4 − 16)
Range
-16 to 47.75 °C
Unit
°C

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Leak indicator TRITON_AC_LEAK_INDICATORConfirmed

  • Request21 32
  • Service 21PID 32
  • Module688 → 511
  • Every3600 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 7 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Leak indicator at 20% TRITON_AC_LEAK_INDICATOR_20Confirmed

  • Request21 32
  • Service 21PID 32
  • Module688 → 511
  • Every3600 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bit 5 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Max pressure TRITON_AC_MAX_PRESConfirmed

  • Request21 81
  • Service 21PID 81
  • Module688 → 511
  • Every3600 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 96 to 103 of the reply, 8 bits.

0x00 = 0 → (0 × 3.3 ÷ 255) = 0

Formula
(val × 3.3 ÷ 255)
Range
0 to 3.3
Unit
Raw value

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Output mode TRITON_AC_OUTPUT_MODEConfirmed

  • Request21 22
  • Service 21PID 22
  • Module688 → 511
  • Every5 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 16
Unit
Number

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Passenger side output speed TRITON_AC_OUTPUT_VSS_ASConfirmed

  • Request21 22
  • Service 21PID 22
  • Module688 → 511
  • Every5 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 2) = 0

Formula
(val ÷ 2)
Range
0 to 16
Unit
Number

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Passenger temperature setting TRITON_AC_PASSENGER_TConfirmed

  • Request21 34
  • Service 21PID 34
  • Module688 → 511
  • Every5 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 8 to 15 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 2) = 0 °C

Formula
(val ÷ 2)
Range
0 to 50 °C
Unit
°C

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Pressure TRITON_AC_PRESConfirmed

  • Request21 10
  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → (0 × 3.3 ÷ 255) = 0

Formula
(val × 3.3 ÷ 255)
Range
0 to 3.3
Unit
Raw value

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Rear defogger ON/OFF count TRITON_AC_REAR_DEFOGGER_ON_OFF_COUNTConfirmed

  • Request21 80
  • Service 21PID 80
  • Module688 → 511
  • Every3600 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 48 to 63 of the reply, 16 bits.

0x00A0 = 160 → 160

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Recirculation time TRITON_AC_RECIRCULATION_TIMEConfirmed

  • Request21 81
  • Service 21PID 81
  • Module688 → 511
  • Every3600 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 176 to 191 of the reply, 16 bits.

0x0E67 = 3687 → (3687 × 5) = 18,435 min

Formula
(val × 5)
Range
0 to 327675 min
Unit
min

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Solar sensor TRITON_AC_SOLAR_SNSConfirmed

  • Request21 10
  • Service 21PID 10
  • Module688 → 511
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 31 of the reply, 8 bits.

0x00 = 0 → (0 × 5.5 ÷ 255) = 0

Formula
(val × 5.5 ÷ 255)
Range
0 to 5.5
Unit
Number

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

System work time TRITON_AC_SYSTEM_WORK_TIMEConfirmed

  • Request21 80
  • Service 21PID 80
  • Module688 → 511
  • Every3600 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 0 to 23 of the reply, 24 bits.

0x17E278 = 1565304 → (1565304 × 5) = 7,826,520

Formula
(val × 5)
Range
0 to 83886075
Unit
Number

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Vehicle speed TRITON_AC_VSSConfirmed

Pelican can show this parameter as the speed.

  • Request21 13
  • Service 21PID 13
  • Module688 → 511
  • Every250 ms
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 24 to 39 of the reply, 16 bits.

0x0000 = 0 → 0 km/h

Formula
val
Range
0 to 250 km/h
Unit
km/h

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.