Mitsubishi Triton

Battery parameters

The Mitsubishi Triton has 4 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery temperature TRITON_BAT_TConfirmed

  • Request21 46
  • Service 21PID 46
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → (0 − 40) = -40 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Battery temperature TRITON_BAT_TConfirmed

  • Request21 46
  • Service 21PID 46
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2017, 2019 to 2026

Example reply from a 2018 Mitsubishi Triton.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → (0 − 40) = -40 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.

Engine control module voltage TRITON_ENG_CTRL_MODULE_V

  • Request22 40 00
  • Service 22DID 4000
  • ModuleDA15 → 15
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 183 ÷ 2500)
Range
0 to 18.66 V
Unit
V

In testing for 2023 to 2026.

Turbocharger, actual position TRITON_TURBOCHARGER_ACT_POS

  • Request22 45 06
  • Service 22DID 4506
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2023 to 2026.

Turbocharger, target position TRITON_TURBOCHARGER_TGT_POS

  • Request22 45 06
  • Service 22DID 4506
  • ModuleDA15 → 15
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2023 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.