Control parameters
The Mitsubishi Triton has 4 control parameters.
● Confirmed◆ In testing○ Supported× Not supported
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Request
01 11 - Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2010, 2013, 2015, 2019, 2022 to 2024.
Brake pedal TRITON_CVT_BRAKEConfirmed
- Request
21 07 - Service 21
PID 07 - Module
7E1 → 7E9 - Every
250 ms - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bit 4 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Brake switch TRITON_MPI_BRAKE_SWITCHConfirmed
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bit 31 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.
Normal brake closed status TRITON_MPI_NORMAL_BRAKE_CLOSED_STSConfirmed
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Mitsubishi Triton.
Bit 30 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2018. In testing for 1988 to 2017, 2019 to 2026.