Peugeot 208

Connectable parameters

The Peugeot 208 has 31 Connectables, parameters that Pelican can monitor automatically.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

High voltage battery charge 208_HVBAT_SOC_RAWConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 D8 10
  • Service 22DID D810
  • Module6B4 → 694
  • Every1 s
  • Testing for 2012 to 2021, 2023 to 2026

Example reply from a 2022 Peugeot 208.

Bits 0 to 15 of the reply, 16 bits.

0x3D8B = 15755 → (15755 ÷ 512) = 30.771484 %

Formula
(val ÷ 512)
Range
0 to 100 %
Unit
%

Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

State of charge

High voltage battery charge 208_HVBAT_SOC_RAWConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 D8 10
  • Service 22DID D810
  • Module6B4 → 694
  • Every1 s
  • Testing for 2012 to 2021, 2023 to 2026

Example reply from a 2022 Peugeot 208.

Bits 0 to 15 of the reply, 16 bits.

0x3D8B = 15755 → (15755 ÷ 512) = 30.771484 %

Formula
(val ÷ 512)
Range
0 to 100 %
Unit
%

Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.

High voltage battery charge, calibrated 208_HVBAT_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 D4 10
  • Service 22DID D410
  • Module6B4 → 694
  • Every1 s
  • Testing for 2012 to 2018, 2024 to 2026

Example reply from a 2023 Peugeot 208.

Bits 0 to 15 of the reply, 16 bits.

0x5621 = 22049 → (22049 ÷ 512) = 43.064453 %

Formula
(val ÷ 512)
Range
0 to 100 %
Unit
%

Confirmed for 2019 to 2023. In testing for 2012 to 2016, 2024, 2026. Not supported for 2017 to 2018, 2025.

State of health

High voltage battery health 208_HVBAT_SOHConfirmed

Pelican can show this parameter as the state of health.

  • Request22 D8 60
  • Service 22DID D860
  • Module6B4 → 694
  • Every3600 s
  • Testing for 2012 to 2021, 2023 to 2026

Example reply from a 2022 Peugeot 208.

Bits 8 to 23 of the reply, 16 bits.

0x05FB = 1531 → (1531 ÷ 16) = 95.6875 %

Formula
(val ÷ 16)
Range
0 to 100 %
Unit
%

Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.

Speed

Vehicle speed 208_VSSConfirmed

Pelican can show this parameter as the speed.

  • Request22 D4 02
  • Service 22DID D402
  • Module6A2 → 682
  • Every1 s
  • Testing for 2012 to 2021, 2023 to 2026

Example reply from a 2022 Peugeot 208.

Bits 0 to 15 of the reply, 16 bits.

0x028C = 652 → (652 ÷ 10) = 65.2 km/h

Formula
(val ÷ 10)
Range
0 to 1000 km/h
Unit
km/h

Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.

Vehicle speed 208_VSS_6A8

Pelican can show this parameter as the speed.

  • Request22 D4 02
  • Service 22DID D402
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 km/h
Unit
km/h

In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.

Vehicle speed 208_VSS_6A9

Pelican can show this parameter as the speed.

  • Request22 D7 11
  • Service 22DID D711
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.

Vehicle speed 208_VSS_6B4Confirmed

Pelican can show this parameter as the speed.

  • Request22 D8 02
  • Service 22DID D802
  • Module6B4 → 694
  • Every250 ms
  • Testing for 2012 to 2021, 2023 to 2026

Example reply from a 2022 Peugeot 208.

Bits 0 to 31 of the reply, 32 bits.

0x00001B70 = 7024 → (7024 × 64 ÷ 65535) = 6.85948 km/h

Formula
(val × 64 ÷ 65535)
Range
0 to 4194368 km/h
Unit
km/h

Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.

Vehicle speed VSSSAE J1979Confirmed

Pelican can show this parameter as the speed.

  • Request01 0D
  • Service 01PID 0D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 km/h
Unit
km/h

Confirmed for 2017, 2019, 2021, 2023. Supported for 2016, 2022, 2024 to 2025.

Vehicle speed, ESP 208_VSS_ESPConfirmed

Pelican can show this parameter as the speed.

  • Request22 D8 02
  • Service 22DID D802
  • Module6A2 → 682
  • Every250 ms
  • Testing for 2012 to 2021, 2023 to 2026

Example reply from a 2022 Peugeot 208.

Bits 0 to 15 of the reply, 16 bits.

0x0347 = 839 → (839 × 1953 ÷ 250000) = 6.554268 km/h

Formula
(val × 1953 ÷ 250000)
Range
0 to 511 km/h
Unit
km/h

Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.

Odometer

Odometer 208_ODO_6A2

Pelican can show this parameter as the odometer.

  • Request22 D4 9C
  • Service 22DID D49C
  • Module6A2 → 682
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.

Odometer 208_ODO_6A6Confirmed

Pelican can show this parameter as the odometer.

  • Request22 D4 9C
  • Service 22DID D49C
  • Module6A6 → 686
  • Every30 s
  • Testing for 2012 to 2021, 2023 to 2026

Example reply from a 2022 Peugeot 208.

Bits 0 to 31 of the reply, 32 bits.

0x00007BEB = 31723 → (31723 ÷ 10) = 3,172.3 km

Formula
(val ÷ 10)
Range
0 to 429496729 km
Unit
km

Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.

Odometer 208_ODO_6A9

Pelican can show this parameter as the odometer.

  • Request22 D8 02
  • Service 22DID D802
  • Module6A9 → 689
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.

Odometer 208_ODOConfirmed

Pelican can show this parameter as the odometer.

  • Request22 D4 9C
  • Service 22DID D49C
  • Module6B4 → 694
  • Every1 s
  • Testing for 2012 to 2021, 2023 to 2026

Example reply from a 2022 Peugeot 208.

Bits 0 to 31 of the reply, 32 bits.

0x01EFB000 = 32485376 → (32485376 ÷ 1000) = 32,485.376 km

Formula
(val ÷ 1000)
Range
0 to 4294967 km
Unit
km

Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.

Total mileage 208_ODO_6A8

Pelican can show this parameter as the odometer.

  • Request22 D4 9C
  • Service 22DID D49C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.

CheckEngineLightOn

Malfunction indicator lamp MILSAE J1979Confirmed

The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.

Pelican can show this parameter as the checkEngineLightOn.

  • Request01 01
  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.

Commanded lambda

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2019, 2021. Supported for 2023, 2025.

Distance since trouble codes were cleared

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Request01 31
  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2019, 2021. Supported for 2022 to 2025.

Engine coolant temperature

Coolant temperature 208_ECTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request22 D8 FB
  • Service 22DID D8FB
  • Module6A2 → 682
  • Every5 s
  • Testing for 2012 to 2021, 2023 to 2026

Example reply from a 2022 Peugeot 208.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x014A = 330 → (330 ÷ 10) = 33 °C

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.

Coolant temperature 208_ECT_6A8

Pelican can show this parameter as the engine coolant temperature.

  • Request22 D4 15
  • Service 22DID D415
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017, 2019, 2021. Supported for 2016, 2022 to 2025.

Engine load

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017, 2019, 2021. Supported for 2016, 2022 to 2025.

Engine oil temperature

Oil temperature 208_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Request22 D4 7D
  • Service 22DID D47D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.

Engine speed

Engine RPM 208_RPM

Pelican can show this parameter as the engine speed.

  • Request22 D4 00
  • Service 22DID D400
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.

Fuel rate

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Request01 5E
  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3212.75 L/h
Unit
L/h

Confirmed for 2019, 2021. Supported for 2025.

O2 lambda

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2019, 2021. Supported for 2023 to 2025.

Short term fuel trim

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2017, 2019, 2021. Supported for 2016, 2022 to 2025.

Starter battery voltage

Engine control computer supply voltage 208_ENG_CTRL_COMPUTER_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 D4 22
  • Service 22DID D422
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 V
Unit
V

In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.

Service battery voltage 208_SERVICE_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 D7 8A
  • Service 22DID D78A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 V
Unit
V

In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.

StoredDTCCount

Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed

Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.

Pelican can show this parameter as the storedDTCCount.

  • Request01 01
  • Service 01PID 01
  • Module7E0 → 7E8
  • Every10 s

Bits 1 to 7 of the reply, 7 bits.

Formula
val
Range
0 to 127
Unit
Number

Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.

Throttle position

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Request01 11
  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017. Supported for 2016, 2019, 2021 to 2025.

Transmission fluid temperature

Automatic transmission fluid temperature 208_AUTOMATIC_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 D5 50
  • Service 22DID D550
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.