Engine parameters
The Peugeot 208 has 177 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
5V power supply state number 1 208_5V_POWER_SUP_ST_1
- Request
22 D4 23 - Service 22
DID D423 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
5V power supply state number 2 208_5V_POWER_SUP_ST_2
- Request
22 D4 24 - Service 22
DID D424 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
5V power supply state number 3 208_5V_POWER_SUP_ST_3
- Request
22 D4 25 - Service 22
DID D425 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
5V power supply state number 4 208_5V_POWER_SUP_ST_4
- Request
22 D4 26 - Service 22
DID D426 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
12V network allowed stop 208_12V_NETWORK_ALLOWED
- Request
22 D7 4C - Service 22
DID D74C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, brake electromagnetic valve B1 208_NUM_ACTIVATIONS_B1
- Request
22 D7 45 - Service 22
DID D745 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, line pressure control solenoid 208_NUM_LINE_P_CTRL
- Request
22 D7 51 - Service 22
DID D751 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, the electromagnetic valve of brake B2 208_NUM_ACTIVATIONS_B2
- Request
22 D7 5A - Service 22
DID D75A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Additional heater control 1 208_ADDITIONAL_HEATER_1
- Request
22 D4 16 - Service 22
DID D416 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Air conditioning 208_AC
- Request
22 D4 AF - Service 22
DID D4AF - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Air conditioning compressor current 208_AC_COMP_CURRENT
- Request
22 D4 1C - Service 22
DID D41C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Air conditioning high side pressure 208_AC_HIGH_SIDE_PConfirmed
- Request
22 D8 FF - Service 22
DID D8FF - Module
6A2 → 682 - Every
1 s - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 15 of the reply, 16 bits.
0x03E6 = 998 → (998 ÷ 10) = 99.8 bar
- Formula
(val ÷ 10)- Range
- 0 to 6553 bar
- Unit
- bar
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Air conditioning pressure 208_AC_P
- Request
22 D4 21 - Service 22
DID D421 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Air flow 208_AIR_FLOW
- Request
22 D4 89 - Service 22
DID D489 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Air flow target 208_AIR_FLOW_TGT
- Request
22 D4 8E - Service 22
DID D48E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Air temperature by air flow meter 208_AIR_T_AIR_FLOW_METER
- Request
22 D5 4E - Service 22
DID D54E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Alternator load value 208_ALTERNATOR_LOAD
- Request
22 D4 A5 - Service 22
DID D4A5 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Ambient air temperature 208_AAT_6A9
- Request
22 D5 52 - Service 22
DID D552 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Ambient temperature 208_AATConfirmed
- Request
22 D4 34 - Service 22
DID D434 - Module
6A2 → 682 - Every
5 s - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x15 = 21 → 21 °C
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
ANTI START PROGRAMMING STATUS 208_ANTI_START
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Atmospheric pressure 208_ATMOSPHERIC_P
- Request
22 D4 65 - Service 22
DID D465 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic restart request from body control module 208_AUTOMATIC_RESTART_REQ_BSI
- Request
22 D7 0A - Service 22
DID D70A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic restart request from engine management computer 208_AUTOMATIC_RESTART
- Request
22 D7 09 - Service 22
DID D709 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic stop allowed by body control module 208_AUTOMATIC_STOP
- Request
22 D7 03 - Service 22
DID D703 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic stop allowed by power steering computer 208_AUTOMATIC_STOP_ALLOWED_POWER_STEER
- Request
22 D7 05 - Service 22
DID D705 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Auxiliary heater 2 control 208_AUXILIARY_HEATER_2
- Request
22 D4 17 - Service 22
DID D417 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
Boost air temperature 208_BOOST_AIR_T
- Request
22 D4 11 - Service 22
DID D411 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Button state 208_BUTTON_ST
- Request
22 D5 17 - Service 22
DID D517 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2019, 2021. Supported for 2016, 2022 to 2025.
Camshaft/crankshaft position synchronization 208_CAM_CRANK_POS
- Request
22 D4 18 - Service 22
DID D418 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2019. Supported for 2021, 2023 to 2025.
CHANGE REPORT IN PROGRESS 208_CHANGE_REPORT
- Request
22 D5 16 - Service 22
DID D516 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Combustion engine state 208_ICE_ST
- Request
22 D7 09 - Service 22
DID D709 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2019, 2021. Supported for 2023, 2025.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019. Supported for 2021, 2023.
Commanded wastegate A position WG_A_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Commanded wastegate B position WG_B_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Computer lock 208_COMPUTER_LOCK
- Request
22 DA DD - Service 22
DID DADD - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Computer remote wake-up state 208_COMPUTER_WAKE_UP_ST
- Request
22 D5 15 - Service 22
DID D515 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Computer restarts since memory erase 208_CNT_NUM_RE
- Request
22 D4 D8 - Service 22
DID D4D8 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Computer temperature 208_COMPUTER_T
- Request
22 D4 35 - Service 22
DID D435 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Control current of electromagnetic valve for changing the pressure in the brake system B2 208_CTRL_CURRENT_P_B2
- Request
22 D6 22 - Service 22
DID D622 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Control current of the electromagnetic valve for changing the pressure in the brake system B1 208_CTRL_CURRENT_P_B1
- Request
22 D6 08 - Service 22
DID D608 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Coolant temperature 208_ECTConfirmed
Pelican can show this parameter as the engine coolant temperature.
- Request
22 D8 FB - Service 22
DID D8FB - Module
6A2 → 682 - Every
5 s - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x014A = 330 → (330 ÷ 10) = 33 °C
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Coolant temperature 208_ECT_6A8
Pelican can show this parameter as the engine coolant temperature.
- Request
22 D4 15 - Service 22
DID D415 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Coolant temperature target 208_ECT_TGT
- Request
22 D4 0D - Service 22
DID D40D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Coolant temperature, corrected 208_ECT_CORRECTED
- Request
22 D4 0A - Service 22
DID D40A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Cruise control, RW status 208_CRUISE_CTRL_RW_STAT
- Request
22 D4 B0 - Service 22
DID D4B0 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Date 208_DATE
- Request
22 D4 CA - Service 22
DID D4CA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 s
- Unit
- s
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Drive motor coolant inlet temperature 208_DRIVE_MOTOR_CLT_TConfirmed
- Request
22 D8 D6 - Service 22
DID D8D6 - Module
6A2 → 682 - Every
5 s - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0019 = 25 → 25 °C
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Drive motor power 208_DRIVE_MOTOR_POWERConfirmed
- Request
22 D8 D9 - Service 22
DID D8D9 - Module
6A2 → 682 - Every
1 s - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 × 100) = 0 W
- Formula
(val × 100)- Range
- -3276800 to 3276700 W
- Unit
- W
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Drive motor stator temperature 208_DRIVE_MOTOR_STATOR_TConfirmed
- Request
22 D8 CD - Service 22
DID D8CD - Module
6A2 → 682 - Every
5 s - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0016 = 22 → 22 °C
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Drive motor torque, actual 208_DRIVE_MOTOR_TQ_ACTConfirmed
- Request
22 D8 D0 - Service 22
DID D8D0 - Module
6A2 → 682 - Every
250 ms - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0005 = 5 → (5 ÷ 10) = 0.5 N·m
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Drive motor torque, desired 208_DRIVE_MOTOR_TQ_DESConfirmed
- Request
22 D8 80 - Service 22
DID D880 - Module
6A2 → 682 - Every
250 ms - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 100) = 0 N·m
- Formula
(val ÷ 100)- Range
- -327 to 327 N·m
- Unit
- N·m
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Driver presence 208_DRIVER_PRESENCE
- Request
22 D7 23 - Service 22
DID D723 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Driver, requested torque value 208_DRIVER_REQ_TQ
- Request
22 D5 07 - Service 22
DID D507 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Economy mode off state 208_ECO_MODE_OFF_ST
- Request
22 D7 24 - Service 22
DID D724 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Electric cooling fan control 208_GMV_ELEC_COOLING_FAN
- Request
22 D4 2F - Service 22
DID D42F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Electric machine torque 208_ELEC_MACHINE_TQConfirmed
- Request
22 DC B6 - Service 22
DID DCB6 - Module
6A6 → 686 - Every
250 ms - Testing for 2012 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 1638.3)- Range
- -1638 to 4915 N·m
- Unit
- N·m
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Electric machine torque reduction 208_ELEC_MACHINE_TQ_REDUCTIONConfirmed
- Request
22 DC 69 - Service 22
DID DC69 - Module
6A6 → 686 - Every
250 ms - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 16) = 0 N·m
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Energy accumulator state transfer 208_ENERGY_ACCUMULATOR_ST
- Request
22 D7 55 - Service 22
DID D755 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Energy accumulator temperature limiter state 208_ENERGY_ACCUMULATOR_T
- Request
22 D7 58 - Service 22
DID D758 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Engine control module status 208_ENG_CTRL_MODULE_STAT
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Engine coolant temperature 208_ECT_6A9
- Request
22 D5 55 - Service 22
DID D555 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017, 2019, 2021. Supported for 2016, 2022 to 2025.
Engine operating mode 208_ENG_OP_MODE
- Request
22 D5 53 - Service 22
DID D553 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8)- Range
- 0 to 8191 rpm
- Unit
- rpm
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Engine restart counter 208_ENG_RESTART_CNT
- Request
22 D4 06 - Service 22
DID D406 - Module
6A9 → 689 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Engine restart counter by stop and start function 208_ENG_RESTART_CNT_STOP
- Request
22 D7 1B - Service 22
DID D71B - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Engine restart request sent by ESP computer 208_ENG_RESTART_REQ_SENT
- Request
22 D7 0D - Service 22
DID D70D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2017, 2019. Supported for 2016, 2021 to 2025.
Engine stalls 208_ENG_STALLS
- Request
22 D7 30 - Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Engine start prohibition control, start lock 208_ENG_START
- Request
22 D7 03 - Service 22
DID D703 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Engine stop time 208_ENG_STOP_TIME
- Request
22 D4 77 - Service 22
DID D477 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 s
- Unit
- s
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Estimated torque of internal friction of the engine 208_ESTIMATED_TQ
- Request
22 D4 E2 - Service 22
DID D4E2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Expected generator supplier identifier of the reversible generator 208_EXPECTED_GEN
- Request
22 D7 89 - Service 22
DID D789 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Expected identifier of electronic power circuit of reversible generator generator 208_EXPECTED_IDENTIFIER_ELECTRONIC
- Request
22 D7 88 - Service 22
DID D788 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Expected identifier of reversible generator 208_EXPECTED_IDENTIFIER
- Request
22 D7 87 - Service 22
DID D787 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Request
01 23 - Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2019. Supported for 2021 to 2022, 2024 to 2025.
FUGITIVE TRIP IN EMERGENCY MODE 208_FUGITIVE_TRIP
- Request
22 D6 71 - Service 22
DID D671 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Generator mode 208_GEN_MODE
- Request
22 D7 14 - Service 22
DID D714 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 75)- Range
- 0 to 19125 rpm
- Unit
- rpm
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Generator shutdown 208_GEN_SHUTDOWN
- Request
22 D7 5B - Service 22
DID D75B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Identifier of the electronic power circuit of the reversible generator 208_IDENTIFIER
- Request
22 D7 32 - Service 22
DID D732 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Identifier of the supplier of the reversible generator 208_IDENTIFIER_SUPPLIER
- Request
22 D7 33 - Service 22
DID D733 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Immobilizer code programming status 208_IMMOBILIZER_CODE
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Indicated engine torque 208_INDICATED_ENG_TQ
- Request
22 D4 D2 - Service 22
DID D4D2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
Inverter temperature estimated 208_INVERTER_T_ESTIMATEDConfirmed
- Request
22 DC 6A - Service 22
DID DC6A - Module
6A6 → 686 - Every
5 s - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x06D8 = 1752 → (1752 ÷ 64) = 27.375 °C
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Inverter temperature, commanded 208_INVERTER_T_CMDConfirmed
- Request
22 DC 04 - Service 22
DID DC04 - Module
6A6 → 686 - Every
5 s - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0689 = 1673 → (1673 ÷ 64) = 26.140625 °C
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Line pressure solenoid valve control current 208_SLT_LINE_P_VARIATION
- Request
22 D6 06 - Service 22
DID D606 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Lock status 208_LOCK_STAT
- Request
22 DA DD - Service 22
DID DADD - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2017, 2019. Supported for 2016, 2021 to 2025.
Maximum allowable torque 208_MAX_ALLOWABLE_TQ
- Request
22 D5 06 - Service 22
DID D506 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Measured current of electromagnetic valve for changing the pressure in the brake system B2 208_MEAS_CURRENT_P_B2
- Request
22 D6 23 - Service 22
DID D623 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Measured current of the electromagnetic valve for changing the pressure in the brake system B1 208_MEAS_CURRENT_P_B1
- Request
22 D6 09 - Service 22
DID D609 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Measured line pressure variation solenoid valve current 208_MEAS_LINE_P
- Request
22 D6 07 - Service 22
DID D607 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Mileage since last oil change 208_MILEAGE_SINCE_OIL
- Request
22 D4 3F - Service 22
DID D43F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Minimum cell capacity 208_MIN_CELL_CAPConfirmed
- Request
22 D4 13 - Service 22
DID D413 - Module
6B4 → 694 - Every
1 s - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 7 of the reply, 8 bits.
0x3B = 59 → (59 ÷ 2) = 29.5 %
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Neutral position sensor status 208_NEUTRAL_POS_SENS
- Request
22 D4 38 - Service 22
DID D438 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of engine stop information deletion cycles 208_NUM_ENG_STOP
- Request
22 D7 30 - Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Oil pressure 208_OIL_P
- Request
22 D4 29 - Service 22
DID D429 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Oil pressure reference value 208_OIL_P_REFERENCE
- Request
22 D4 64 - Service 22
DID D464 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Oil pressure regulation control 208_OIL_P_REGULATION
- Request
22 D4 3B - Service 22
DID D43B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Oil temperature 208_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Request
22 D4 7D - Service 22
DID D47D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Outside air temperature 208_AAT_6A8
- Request
22 D4 14 - Service 22
DID D414 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Powertrain condition 208_POWERTRAIN_COND
- Request
22 D4 BA - Service 22
DID D4BA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Presence of the identifier of the reversible generator 208_PRESENCE_IDENTIFIER
- Request
22 D7 31 - Service 22
DID D731 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Problems detected while transmitting unlock code 208_PROBLEMS_DETECTED
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Problems detected while transmitting unlock code 208_PROBLEMS_DETECTED_WHILE
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Real engine torque 208_REAL_ENG_TQ
- Request
22 D5 54 - Service 22
DID D554 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Remote wake-up circuit status 208_REMOTE_WAKE_UP
- Request
22 D7 05 - Service 22
DID D705 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Remote wake-up state 208_REMOTE_WAKE_UP_ST
- Request
22 D7 08 - Service 22
DID D708 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Request to turn on the engine diagnostic indicator 208_REQ_TURN_ON_ENG
- Request
22 D5 11 - Service 22
DID D511 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Requested value controlled thermostat 208_REQ_CONTROLLED
- Request
22 D5 86 - Service 22
DID D586 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 81.92000625)- Range
- -399 to 399 %
- Unit
- %
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Restart request sent by power steering computer 208_RESTART_REQ_SENT
- Request
22 D7 0C - Service 22
DID D70C - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Restart request sent by suspension computer 208_RESTART_REQ_SENT_SUSPENSION
- Request
22 D7 0E - Service 22
DID D70E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Return to engine start and restart control by starter 208_RETURN_ENG_START
- Request
22 D7 64 - Service 22
DID D764 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Return to starter engine restart control 208_RETURN_STARTER_ENG
- Request
22 D7 61 - Service 22
DID D761 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Reverse generator status 208_REVERSE_GEN_STAT
- Request
22 D7 16 - Service 22
DID D716 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Reversible generator torque 208_REVERSIBLE_GEN_TQ
- Request
22 D7 15 - Service 22
DID D715 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Service network related engine restart request 208_SERVICE_NETWORK
- Request
22 D7 4B - Service 22
DID D74B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2017, 2019, 2021. Supported for 2016, 2022 to 2025.
Sport mode contactor state 208_SPORT_MODE_CONTACTOR
- Request
22 D5 03 - Service 22
DID D503 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Start inhibit control, wired 208_START_INHIBIT_CTRL
- Request
22 D7 67 - Service 22
DID D767 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Start or restart inhibition transmitted by engine management computer 208_START_OR_RESTART
- Request
22 D7 1E - Service 22
DID D71E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Start prohibition 208_START_PROHIBITION
- Request
22 D5 1B - Service 22
DID D51B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Starter activation counter 208_STARTER_ACTIVATION
- Request
22 D7 1F - Service 22
DID D71F - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Starter control interface unit operating status 208_STARTER_CTRL
- Request
22 D7 2A - Service 22
DID D72A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Starter duty cycle 208_STARTER_DUTY
- Request
22 D4 78 - Service 22
DID D478 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 s
- Unit
- s
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Starter engagement status 208_STARTER_ENGAGEMENT
- Request
22 D4 C3 - Service 22
DID D4C3 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
State lock/unlock control unit 208_ST_LOCK_UNLOCK_CTRL
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Status of internal ignition motor 208_STAT_INTERNAL_IGN
- Request
22 D4 12 - Service 22
DID D412 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Status of the energy accumulator 208_STAT_ENERGY
- Request
22 D7 22 - Service 22
DID D722 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Stop allowed by ESP computer 208_STOP_ALLOWED_ESP
- Request
22 D7 06 - Service 22
DID D706 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Stop and start function state 208_STOP_START_FUNCTION
- Request
22 D7 25 - Service 22
DID D725 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Stop and start switch 208_STOP_START_SWITCH
- Request
22 D7 26 - Service 22
DID D726 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Stop permitted by suspension computer 208_STOP_PERMITTED
- Request
22 D7 07 - Service 22
DID D707 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Temperature difference between the hottest and the coolest cells 208_T_DIFF_HOTESTConfirmed
- Request
22 D8 78 - Service 22
DID D878 - Module
6B4 → 694 - Every
5 s - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1 °C
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Temperature of the energy accumulator 208_T_ENERGY_ACCUMULATOR
- Request
22 D7 21 - Service 22
DID D721 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
The composition of the mixture is calculated by the oxygen sensor 208_COMPOSITION_MIXTURE
- Request
22 D5 70 - Service 22
DID D570 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2017, 2019. Supported for 2016, 2021 to 2025.
Torque corresponding to driver requirement 208_TQ_CORRESPONDING
- Request
22 D4 E3 - Service 22
DID D4E3 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Torque supplied or taken by generator 208_TQ_SUPPLIED_OR_TAKEN
- Request
22 D7 28 - Service 22
DID D728 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Total mileage 208_ODO_6A8
Pelican can show this parameter as the odometer.
- Request
22 D4 9C - Service 22
DID D49C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Towing device configured 208_CAN_VEH_BE_EQUIPPED
- Request
22 D5 57 - Service 22
DID D557 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Traction circuit coolant temperature 208_TRACTION_CIRCUIT_ECTConfirmed
- Request
22 D8 F9 - Service 22
DID D8F9 - Module
6A2 → 682 - Every
5 s - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x011F = 287 → (287 ÷ 10) = 28.7 °C
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Traction or stability control regulating 208_ASR_OR_ESP_SYSTEM
- Request
22 D5 12 - Service 22
DID D512 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2019.
Vacuum circuit vacuum 208_VACUUM_CIRCUIT
- Request
22 D7 3B - Service 22
DID D73B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Value during generator load smooth increase 208_DURING_GEN_LOAD
- Request
22 D7 53 - Service 22
DID D753 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Vehicle hour meter 208_VEH_HOUR_METER
- Request
22 D8 01 - Service 22
DID D801 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 s
- Unit
- s
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Vehicle mileage since the last oil change under severe vehicle operating conditions 208_VEH_MILEAGE_SINCE
- Request
22 D5 34 - Service 22
DID D534 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 km
- Unit
- km
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Wastegate A position WG_A_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Wastegate B position WG_B_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Winter mode switch state 208_WINTER_MODE_SWITCH
- Request
22 D5 02 - Service 22
DID D502 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Engine › Internal
Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2019.
Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 kPa
- Unit
- kPa
Confirmed for 2019.
Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2019.
Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2019.
Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2019, 2021. Supported for 2023 to 2025.
O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed
- Request
01 15 - Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed
- Request
01 14 - Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 128)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2019. Supported for 2016 to 2017, 2021 to 2025.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2019, 2021. Supported for 2023 to 2025.