Transmission parameters
The Peugeot 208 has 88 transmission parameters.
● Confirmed◆ In testing○ Supported× Not supported
Activation count, additional oil pump, ATN8 gearbox 208_NUM_ADDITIONAL_OIL
- Request
22 D7 50 - Service 22
DID D750 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, clutch electromagnetic valve C2 208_NUM_ACTIVATIONS_CLU_ELECTROMAGNETIC_VLV_C2
- Request
22 D7 43 - Service 22
DID D743 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, clutch electromagnetic valve C3 208_NUM_ACTIVATIONS_CLU_C3
- Request
22 D7 44 - Service 22
DID D744 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, clutch protection C1 208_NUM_ACTIVATIONS_CLU_C1
- Request
22 D7 31 - Service 22
DID D731 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, clutch protection C2 208_NUM_ACTIVATIONS_CLU_C2
- Request
22 D7 31 - Service 22
DID D731 - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, gear 7 208_NUM_ACTIVATIONS_GEAR_7
- Request
22 D7 5B - Service 22
DID D75B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, shift solenoid SC2 208_NUM_SHIFT_SOLENOID
- Request
22 D7 52 - Service 22
DID D752 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, shift solenoid SC3 208_NUM_SHIFT_SOLENOID_ACTIVATIONS_SC3
- Request
22 D7 53 - Service 22
DID D753 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, the electromagnetic valve for controlling the automatic transmission locking finger in position p 208_NUM_ACTIVATIONS_P
- Request
22 D7 58 - Service 22
DID D758 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, the electromagnetic valve of clutch C4 208_NUM_ACTIVATIONS_C4
- Request
22 D7 59 - Service 22
DID D759 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, the electromagnetic valve of the clutch C1 208_NUM_ACTIVATIONS_C1
- Request
22 D7 42 - Service 22
DID D742 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation count, torque converter lockup electromagnetic valve 208_NUM_ACTIVATIONS_TQ
- Request
22 D7 46 - Service 22
DID D746 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Activation of additional oil pump, ATN8 gearbox 208_ACTIVATION
- Request
22 D6 16 - Service 22
DID D616 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Additional oil pump control status, atn8 transmission 208_ADDITIONAL_OIL_PMP
- Request
22 D6 17 - Service 22
DID D617 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic restart request from transmission computer 208_AUTOMATIC_RESTART_REQ
- Request
22 D7 0B - Service 22
DID D70B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic stop allowed by gearbox computer 208_AUTOMATIC_STOP_ALLOWED
- Request
22 D7 04 - Service 22
DID D704 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic transmission fluid temperature 208_AUTOMATIC_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 D5 50 - Service 22
DID D550 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic transmission in emergency mode 208_AUTOMATIC_TRANS_EMERGENCY
- Request
22 D6 70 - Service 22
DID D670 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic transmission in park position 208_AUTOMATIC_TRANS_PARK
- Request
22 D7 0B - Service 22
DID D70B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic transmission input shaft mode, calculated 208_AUTOMATIC_TRANS_INPUT_SHFT_MODE
- Request
22 D6 51 - Service 22
DID D651 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2)- Range
- 0 to 131070 rpm
- Unit
- rpm
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic transmission input shaft mode, measured 208_AUTOMATIC_TRANS_INPUT_SHFT
- Request
22 D6 50 - Service 22
DID D650 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2)- Range
- 0 to 131070 rpm
- Unit
- rpm
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic transmission lubrication solenoid control current 208_AUTOMATIC_TRANS_LUBRICATION
- Request
22 D6 1A - Service 22
DID D61A - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic transmission oil aging sensor 208_AUTOMATIC_TRANS_OIL
- Request
22 D4 05 - Service 22
DID D405 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic transmission oil drain 208_DRAIN_TRANS
- Request
22 D5 09 - Service 22
DID D509 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic transmission output shaft mode, calculated 208_AUTOMATIC_TRANS_OUTPUT_SHFT_MODE
- Request
22 D6 53 - Service 22
DID D653 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 64 − 8128)- Range
- -8128 to 4186112 rpm
- Unit
- rpm
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic transmission output shaft mode, measured 208_AUTOMATIC_TRANS_OUTPUT
- Request
22 D6 52 - Service 22
DID D652 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic transmission overheat indicator request 208_AUTOMATIC_TRANS
- Request
22 D5 10 - Service 22
DID D510 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Automatic transmission torque request 208_AUTOMATIC_TRANS_TQ
- Request
22 D5 08 - Service 22
DID D508 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Calculated gear in gearbox 208_CALC_GEAR_GEARBOX
- Request
22 D4 09 - Service 22
DID D409 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Clutch pedal 208_CLU_PEDAL
- Request
22 D4 04 - Service 22
DID D404 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Clutch pedal position value 208_CLU_PEDAL_POS
- Request
22 D4 69 - Service 22
DID D469 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Control current of electromagnetic valve for regulating the pressure in the control system of the oil pressure accumulator, AMN8 gearbox 208_CTRL_CURRENT_P_P
- Request
22 D6 25 - Service 22
DID D625 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Control current of electromagnetic valve of actuator of automatic transmission lock-up in position p 208_CTRL_CURRENT_ELECTROMAGNETIC_VLV_P
- Request
22 D6 1E - Service 22
DID D61E - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Control current of electromagnetic valve of change of pressure of torque converter lock-up 208_CTRL_CURRENT_P
- Request
22 D6 1C - Service 22
DID D61C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Control current of the electromagnetic valve for changing the gear shift SC2 208_CTRL_CURRENT
- Request
22 D6 0A - Service 22
DID D60A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Control current of the electromagnetic valve of change of pressure of clutch C3 208_CTRL_CURRENT_P_C3
- Request
22 D6 14 - Service 22
DID D614 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Control current of the electromagnetic valve of change of pressure of clutch C4 208_CTRL_CURRENT_P_C4
- Request
22 D6 20 - Service 22
DID D620 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Control current of the solenoid valve for changing the pressure of the clutch C1 208_CTRL_CURRENT_P_C1
- Request
22 D6 10 - Service 22
DID D610 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Control current of the solenoid valve for changing the pressure of the clutch C2 208_CTRL_CURRENT_P_C2
- Request
22 D6 12 - Service 22
DID D612 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
DC-DC converter temperature 208_DC_DC_CONV_TConfirmed
- Request
22 D8 CE - Service 22
DID D8CE - Module
6A2 → 682 - Every
5 s - Testing for 2012 to 2021, 2023 to 2026
Example reply from a 2022 Peugeot 208.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x001A = 26 → 26 °C
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
Confirmed for 2022. In testing for 2012 to 2021, 2023 to 2026.
Engaged gear 208_ENGAGED_GEAR
- Request
22 D4 3D - Service 22
DID D43D - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Engaged gear 208_ENGAGED_GEAR_6A9
- Request
22 D5 01 - Service 22
DID D501 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Exhaust gas temperature after upstream catalytic converter 208_EXH_GAS_T_AFTER_PRE
- Request
22 D5 55 - Service 22
DID D555 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Exhaust gas temperature before upstream catalytic converter 208_EXH_GAS_T_BEFORE_PRE
- Request
22 D5 2E - Service 22
DID D52E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Gear in the process of engaging 208_GEAR_PROCESS
- Request
22 D4 3E - Service 22
DID D43E - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Gear shift knob under steering wheel 208_GEAR_SHIFT_KNOB
- Request
22 D5 20 - Service 22
DID D520 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Gear shift lever position displayed on instrument panel 208_GEAR_SHIFT_LEVER_POS_ON
- Request
22 D5 00 - Service 22
DID D500 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Maximum clutch travel during gear shift 208_MAX_CLU_TRAVEL
- Request
22 D4 98 - Service 22
DID D498 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 %
- Unit
- %
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Measured current of control of electromagnetic valve of automatic transmission lubrication 208_MEAS_CURRENT_CTRL
- Request
22 D6 1B - Service 22
DID D61B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Measured current of control of electromagnetic valve of change of pressure of torque converter lock-up 208_MEAS_CURRENT_CTRL_P
- Request
22 D6 1D - Service 22
DID D61D - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Measured current of the electromagnetic valve for changing the gear shift SC2 208_MEAS_CURRENT
- Request
22 D6 0B - Service 22
DID D60B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Measured current of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 208_MEAS_CURRENT_P_P
- Request
22 D6 26 - Service 22
DID D626 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Measured current of the electromagnetic valve of change of pressure of clutch C3 208_MEAS_CURRENT_P_C3
- Request
22 D6 15 - Service 22
DID D615 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Measured current of the electromagnetic valve of change of pressure of clutch C4 208_MEAS_CURRENT_P_C4
- Request
22 D6 21 - Service 22
DID D621 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Measured current of the solenoid valve for changing the pressure of the clutch C1 208_MEAS_CURRENT_P_C1
- Request
22 D6 11 - Service 22
DID D611 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Measured current of the solenoid valve for changing the pressure of the clutch C2 208_MEAS_CURRENT_P_C2
- Request
22 D6 13 - Service 22
DID D613 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Measured current of the solenoid valve for controlling the locking finger of the automatic transmission in position p 208_MEAS_CURRENT_P
- Request
22 D6 1F - Service 22
DID D61F - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of engagements of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 208_NUM_ENGAGEMENTS_P_P
- Request
22 D7 5D - Service 22
DID D75D - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of gear engagements 1 208_NUM_GEAR_ENGAGEMENTS_1
- Request
22 D7 47 - Service 22
DID D747 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of gear engagements 2 208_NUM_GEAR_ENGAGEMENTS_2
- Request
22 D7 48 - Service 22
DID D748 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of gear engagements 3 208_NUM_GEAR_ENGAGEMENTS_3
- Request
22 D7 49 - Service 22
DID D749 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of gear engagements 4 208_NUM_GEAR_ENGAGEMENTS_4
- Request
22 D7 4A - Service 22
DID D74A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of gear engagements 5 208_NUM_GEAR_ENGAGEMENTS_5
- Request
22 D7 4B - Service 22
DID D74B - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of gear engagements 6 208_NUM_GEAR_ENGAGEMENTS_6
- Request
22 D7 4C - Service 22
DID D74C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of gear engagements 8 208_NUM_GEAR_ENGAGEMENTS_8
- Request
22 D7 5C - Service 22
DID D75C - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of gear engagements n 208_NUM_GEAR_ENGAGEMENTS_N
- Request
22 D7 4E - Service 22
DID D74E - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of gear engagements right 208_NUM_GEAR_ENGAGEMENTS
- Request
22 D7 4D - Service 22
DID D74D - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of shift solenoid operated automatic transmission lubrication control valve 208_NUM_SHIFT_SOLENOID_OPERATED
- Request
22 D7 56 - Service 22
DID D756 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of shift solenoid operated SC4 208_NUM_SHIFT_SOLENOID_OPERATED_SC4
- Request
22 D7 54 - Service 22
DID D754 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of shift solenoid operated SC5 208_NUM_SHIFT_SOLENOID_OPERATED_SC5
- Request
22 D7 55 - Service 22
DID D755 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Number of shift solenoid operated torque converter lock-up pressure regulating valve 208_NUM_SHIFT_SOLENOID_P
- Request
22 D7 57 - Service 22
DID D757 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Operating mode used by the automatic transmission 208_OP_MODE_USED
- Request
22 D6 73 - Service 22
DID D673 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Position of the gearshift lever 208_POS_GEARSHIFT_LEVER
- Request
22 D7 00 - Service 22
DID D700 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Proportional clutch pedal sensor 208_PROPORTIONAL_CLU
- Request
22 D5 6E - Service 22
DID D56E - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Reverse gear contactor status 208_REVERSE_GEAR
- Request
22 D4 3C - Service 22
DID D43C - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
SC5 shift solenoid control current 208_SC5_SHIFT_SOLENOID
- Request
22 D6 18 - Service 22
DID D618 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
SC5 shift solenoid measured current 208_SC5_SHIFT_SOLENOID_MEAS
- Request
22 D6 19 - Service 22
DID D619 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Shift solenoid control current SC3 208_SHIFT_SOLENOID_CTRL
- Request
22 D6 0C - Service 22
DID D60C - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Shift solenoid control current SC4 208_SHIFT_SOLENOID_CTRL_CURRENT_SC4
- Request
22 D6 0E - Service 22
DID D60E - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Shift solenoid measured current SC3 208_SHIFT_SOLENOID_MEAS
- Request
22 D6 0D - Service 22
DID D60D - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Shift solenoid measured current SC4 208_SHIFT_SOLENOID_MEAS_CURRENT_SC4
- Request
22 D6 0F - Service 22
DID D60F - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Shift-lock control 208_SHIFT_LOCK_CTRL
- Request
22 D7 01 - Service 22
DID D701 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Start permission from gearbox computer 208_START_PERMISSION
- Request
22 D4 1A - Service 22
DID D41A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Torque converter lock-up pressure variation solenoid valve control current 208_TQ_CONV_LOCK_UP_P
- Request
22 D6 04 - Service 22
DID D604 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Torque converter lock-up pressure variation solenoid valve control current 208_TQ_CONV_LOCK_UP_P_VARIATION
- Request
22 D6 05 - Service 22
DID D605 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Torque converter slip mode, theoretical value 208_TQ_CONV_SLIP_MODE
- Request
22 D6 55 - Service 22
DID D655 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 64 − 8128)- Range
- -8128 to 8192 rpm
- Unit
- rpm
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Torque converter status 208_TQ_CONV_STAT
- Request
22 D5 04 - Service 22
DID D504 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.
Upstream catalytic converter aging 208_PRE_CATALYTIC_CONV
- Request
22 D5 59 - Service 22
DID D559 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 %
- Unit
- %
In testing for 2012 to 2021, 2023 to 2026. Not supported for 2022.