Engine parameters
The Hyundai Venue has 124 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2025.
Automatic transmission fluid temperature VENUE_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 A0 - Service 21
PID A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.
Automatic transmission fluid temperature VENUE_ATF_T_7E1
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2019 to 2026.
Barometric pressure VENUE_BAROMETRIC_PRESSURE
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 319 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 kPa
- Unit
- kPa
In testing for 2019 to 2026.
Boost pressure VENUE_BOOST_P
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val × 1372549 ÷ 100000)- Range
- 0 to 3499.9999
- Unit
- Raw value
In testing for 2019 to 2026.
Boost regulator duty VENUE_BOOST_REGULATOR_DUTY
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. Supported for 2022.
Catalyst damaging misfires total all cylinders VENUE_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Catalyst damaging misfires total, cylinder 1 VENUE_CATALYST_DAMAGING_MISFIRES_TOTAL_C1
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Catalyst damaging misfires total, cylinder 2 VENUE_CATALYST_DAMAGING_MISFIRES_TOTAL_C2
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Catalyst damaging misfires total, cylinder 3 VENUE_CATALYST_DAMAGING_MISFIRES_TOTAL_C3
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Catalyst damaging misfires total, cylinder 4 VENUE_CATALYST_DAMAGING_MISFIRES_TOTAL_C4
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Clutch solenoid duty VENUE_CLUTCH_SOLENOID_DUTY
- Request
21 C0 - Service 21
PID C0 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2019 to 2026.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2025. Supported for 2022.
Commanded throttle actuator VENUE_COMMANDED_THROTTLE_ACTUATOR
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.390625)- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2019 to 2026.
Commanded torque VENUE_COMMANDED_TORQUE
- Request
21 C0 - Service 21
PID C0 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 N·m
- Unit
- N·m
In testing for 2019 to 2026.
Coolant) VENUE_COOLANT_FAN_PWM
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Diesel particulate filter differential pressure VENUE_DPF_DIFF_P
- Request
22 E0 F1 - Service 22
DID E0F1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val × 431373 ÷ 100000 − 100)- Range
- -100 to 1000.0011
- Unit
- Raw value
In testing for 2019 to 2026.
Diesel particulate filter differential pressure VENUE_DPF_DIFFERENTIAL_PRESSURE
- Request
21 1B - Service 21
PID 1B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5
- Unit
- Raw value
In testing for 2019 to 2026.
Diesel particulate filter load, from model VENUE_DPF_LOAD_MODEL
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 296 to 303 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Diesel particulate filter regen demand counter VENUE_DPF_REGEN_DEMAND_CNT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 432 to 439 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Diesel particulate filter regen success state VENUE_DPF_REGEN_SUCCESS_ST
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 407 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2026.
Diesel particulate filter regen, completed state VENUE_DPF_REGEN_COMPLETED
- Request
22 ED 06 - Service 22
DID ED06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Diesel particulate filter regeneration state VENUE_DPF_REGENERATION_STATE
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 207 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2026.
Emission relevant misfires total all cylinders VENUE_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Emission relevant misfires total, cylinder 1 VENUE_EMISSION_RELEVANT_MISFIRES_TOTAL_C1
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Emission relevant misfires total, cylinder 2 VENUE_EMISSION_RELEVANT_MISFIRES_TOTAL_C2
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Emission relevant misfires total, cylinder 3 VENUE_EMISSION_RELEVANT_MISFIRES_TOTAL_C3
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Emission relevant misfires total, cylinder 4 VENUE_EMISSION_RELEVANT_MISFIRES_TOTAL_C4
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Engine coolant temperature VENUE_ENGINE_COOLANT_T
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val × 0.75 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2019 to 2024, 2026. Not supported for 2025.
Engine oil temperature VENUE_ENGINE_OIL_T
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val × 0.75 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2019 to 2024, 2026. Not supported for 2025.
Engine oil temperature VENUE_EOTConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 272 to 279 of the reply, 8 bits.
0x9C = 156 → (156 × 3 ÷ 4 − 48) = 69 °C
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Engine oil temperature VENUE_EOT_V2
- Request
22 ED 02 - Service 22
DID ED02 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val − 4)- Range
- -4 to 251 °C
- Unit
- °C
In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.
Engine RPM VENUE_ENGINE_RPM_TCM
- Request
21 A0 - Service 21
PID A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.
Engine RPM VENUE_RPM
- Request
21 C0 - Service 21
PID C0 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2019 to 2026.
Exhaust gas flow in the particulate filter VENUE_EXH_GAS_FLOW_PF
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val × 392157 ÷ 50)- Range
- 0 to 2000000.7 L
- Unit
- L
In testing for 2019 to 2026.
Exhaust gas temperature VENUE_EXHAUST_GAS_T
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 368 to 375 of the reply, 8 bits.
- Formula
(val × 4.709803922 + 99)- Range
- 99 to 1300 °C
- Unit
- °C
In testing for 2019 to 2026.
Exhaust gas temperature at catalyst VENUE_EXH_GAS_T_CAT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val × 471 ÷ 100 + 99)- Range
- 0 to 1300.05 °C
- Unit
- °C
In testing for 2019 to 2026.
Gasoline direct injection time bank a, 1 VENUE_GDI_IT_A1
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2019 to 2026.
Gasoline direct injection time bank a, 2 VENUE_GDI_IT_A2
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2019 to 2026.
Gasoline direct injection time bank a, 3 VENUE_GDI_IT_A3
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2019 to 2026.
Gasoline direct injection time bank a, 4 VENUE_GDI_IT_A4
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2019 to 2026.
Gasoline direct injection time bank b, 1 VENUE_GDI_IT_B1
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2019 to 2026.
Gasoline direct injection time bank b, 2 VENUE_GDI_IT_B2
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2019 to 2026.
Gasoline direct injection time bank b, 3 VENUE_GDI_IT_B3
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2019 to 2026.
Gasoline direct injection time bank b, 4 VENUE_GDI_IT_B4
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2019 to 2026.
Glow relay duty VENUE_GLOW_RELAY_DUTY
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val × 2451 ÷ 6250)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Heat VENUE_HEAT
- Request
21 C0 - Service 21
PID C0 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2019 to 2026.
Idle control mode VENUE_IDLE_CONTROL_MODE
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Injection duration cylinder 1 VENUE_INJ_DUR_1Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
1 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
0x0026 = 38 → (38 ÷ 1220.7) = 0.03113 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 s
- Unit
- s
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Injection duration cylinder 2 VENUE_INJ_DUR_2Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
1 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
0x0026 = 38 → (38 ÷ 1220.7) = 0.03113 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 s
- Unit
- s
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Injection duration cylinder 3 VENUE_INJ_DUR_3Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
1 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
0x0026 = 38 → (38 ÷ 1220.7) = 0.03113 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 s
- Unit
- s
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Injection duration cylinder 4 VENUE_INJ_DUR_4Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
1 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
0x0026 = 38 → (38 ÷ 1220.7) = 0.03113 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 s
- Unit
- s
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Intake air temperature VENUE_EITConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 264 to 271 of the reply, 8 bits.
0x47 = 71 → (71 × 3 ÷ 4 − 48) = 5.25 °C
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Intake air temperature VENUE_INTAKE_AIR_T
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val × 0.75 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
In testing for 2019 to 2024, 2026. Not supported for 2025.
Knock detected VENUE_KNOCK_DETECTED
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Knock learn, cylinder 1 VENUE_KNOCK_LEARN_1Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 160 to 167 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Knock learn, cylinder 2 VENUE_KNOCK_LEARN_2Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 168 to 175 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Knock learn, cylinder 3 VENUE_KNOCK_LEARN_3Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 176 to 183 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Knock learn, cylinder 4 VENUE_KNOCK_LEARN_4Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 184 to 191 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Knock retard cylinder 1 VENUE_KNOCK_RETARD_CYL_1
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2019 to 2026.
Knock retard cylinder 1, alternate VENUE_KNOCK_RETARD_1_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2019 to 2026.
Knock retard cylinder 1, alternate VENUE_KNOCK_RETARD_CYL_1_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2019 to 2026.
Knock retard cylinder 2 VENUE_KNOCK_RETARD_CYL_2
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2019 to 2026.
Knock retard cylinder 2, alternate VENUE_KNOCK_RETARD_2_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2019 to 2026.
Knock retard cylinder 2, alternate VENUE_KNOCK_RETARD_CYL_2_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2019 to 2026.
Knock retard cylinder 3 VENUE_KNOCK_RETARD_CYL_3
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2019 to 2026.
Knock retard cylinder 3, alternate VENUE_KNOCK_RETARD_3_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2019 to 2026.
Knock retard cylinder 3, alternate VENUE_KNOCK_RETARD_CYL_3_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2019 to 2026.
Knock retard cylinder 4 VENUE_KNOCK_RETARD_CYL_4
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2019 to 2026.
Knock retard cylinder 4, alternate VENUE_KNOCK_RETARD_4_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2019 to 2026.
Knock retard cylinder 4, alternate VENUE_KNOCK_RETARD_CYL_4_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2019 to 2026.
Knock retard, cylinder 1 VENUE_KNOCK_RETARD_1Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 96 to 103 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Knock retard, cylinder 2 VENUE_KNOCK_RETARD_2Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 104 to 111 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Knock retard, cylinder 3 VENUE_KNOCK_RETARD_3Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 112 to 119 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Knock retard, cylinder 4 VENUE_KNOCK_RETARD_4Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 120 to 127 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Lock switch VENUE_LOCK_SWITCH
- Request
21 C0 - Service 21
PID C0 - Module
7E5 → 7ED - Every
1 s - Testing
Bit 151 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2026.
Main injection volume VENUE_MAIN_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 0.392156863)- Range
- 0 to 100 L
- Unit
- L
In testing for 2019 to 2026.
Malfunction indicator VENUE_MALFUNCTION_INDICATOR
- Request
21 C0 - Service 21
PID C0 - Module
7E5 → 7ED - Every
1 s - Testing
Bit 175 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2019 to 2026.
Misfires, current, cylinder 1 VENUE_MISFIRES_C1_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires, current, cylinder 2 VENUE_MISFIRES_C2_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires, current, cylinder 3 VENUE_MISFIRES_C3_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires, current, cylinder 4 VENUE_MISFIRES_C4_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
NOx trap outlet pressure VENUE_NOX_TRAP_OUTLET_P
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 288 to 295 of the reply, 8 bits.
- Formula
(val × 3212451 ÷ 25000)- Range
- 0 to 32767.0002
- Unit
- Raw value
In testing for 2019 to 2026.
Output speed VENUE_OUTPUT_SPEED
- Request
21 A0 - Service 21
PID A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.
Pilot injection volume VENUE_PILOT_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 L
- Unit
- L
In testing for 2019 to 2026.
Post injection volume VENUE_POST_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 L
- Unit
- L
In testing for 2019 to 2026.
Pressure sensor VENUE_PRESSURE_SENSOR
- Request
21 C0 - Service 21
PID C0 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 bar
- Unit
- bar
In testing for 2019 to 2026.
Requested torque VENUE_REQUESTED_TORQUE
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 0.001526)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2025. Supported for 2022.
Throttle position #1 VENUE_THROTTLE_POSITION__1
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.0244140625)- Range
- -800 to 799 %
- Unit
- %
In testing for 2019 to 2026.
Throttle position #2 VENUE_THROTTLE_POSITION__2
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.0244140625)- Range
- -800 to 799 %
- Unit
- %
In testing for 2019 to 2026.
Timing advance #1 VENUE_TIMING_ADVANCE_1
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2019 to 2026.
Timing advance #2 VENUE_TIMING_ADVANCE_2
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2019 to 2026.
Timing advance #3 VENUE_TIMING_ADVANCE_3
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2019 to 2026.
Timing advance #4 VENUE_TIMING_ADVANCE_4
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2019 to 2026.
Torque converter slip VENUE_TORQUE_CONVERTER_SLIP
- Request
21 A0 - Service 21
PID A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 rpm
- Unit
- rpm
In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.
Torque converter slip VENUE_TORQUE_CONVERTER_SLIP_7E1
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 rpm
- Unit
- rpm
In testing for 2019 to 2026.
Turbine speed VENUE_TURBINE_SPEED
- Request
21 A0 - Service 21
PID A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.
Turbo boost pressure VENUE_TB_PRES
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 0.008291)- Range
- 0 to 543 kPa
- Unit
- kPa
In testing for 2019 to 2024, 2026. Not supported for 2025.
Variable valve timing temperature VENUE_CVVT_T
Continuously variable valve timing temperature.
- Request
21 18 - Service 21
PID 18 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val − 48)- Range
- -48 to 207 °C
- Unit
- °C
In testing for 2019 to 2026.
Waste gate duty VENUE_WG_DUTY
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
(val × 0.00305176)- Range
- 0 to 199 %
- Unit
- %
In testing for 2019 to 2024, 2026. Not supported for 2025.
Waste gate position VENUE_WG_POS
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
(val × 0.00610352)- Range
- 0 to 399 %
- Unit
- %
In testing for 2019 to 2024, 2026. Not supported for 2025.
Waste gate set point VENUE_WG_SP
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 440 to 455 of the reply, 16 bits.
- Formula
(val × 0.00610352)- Range
- 0 to 399 %
- Unit
- %
In testing for 2019 to 2024, 2026. Not supported for 2025.
Waste gate voltage VENUE_WG_V
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val × 0.000152588)- Range
- 0 to 9.99 V
- Unit
- V
In testing for 2019 to 2024, 2026. Not supported for 2025.
Engine › Misfires
Emission-relevant misfires, cylinder #1 VENUE_MIS_CNT_EMIS_1
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Emission-relevant misfires, cylinder #2 VENUE_MIS_CNT_EMIS_2
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Emission-relevant misfires, cylinder #3 VENUE_MIS_CNT_EMIS_3
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Emission-relevant misfires, cylinder #4 VENUE_MIS_CNT_EMIS_4
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires harmful for catalyst cylinder 1 VENUE_MIS_CAT_1
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires harmful for catalyst cylinder 2 VENUE_MIS_CAT_2
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires harmful for catalyst cylinder 3 VENUE_MIS_CAT_3
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires harmful for catalyst cylinder 4 VENUE_MIS_CAT_4
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires total counter, all cylinders VENUE_MIS_CNT_ALL
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires total counter, cylinder #1 VENUE_MIS_CNT_1
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires total counter, cylinder #2 VENUE_MIS_CNT_2
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires total counter, cylinder #3 VENUE_MIS_CNT_3
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires total counter, cylinder #4 VENUE_MIS_CNT_4
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires, cylinder 1 VENUE_MIS_1
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires, cylinder 2 VENUE_MIS_2
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires, cylinder 3 VENUE_MIS_3
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Misfires, cylinder 4 VENUE_MIS_4
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2026.
Engine › OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2025.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2025.