Hyundai Venue

Engine parameters

The Hyundai Venue has 124 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine oil temperature VENUE_EOTConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 272 to 279 of the reply, 8 bits.

0x9C = 156 → (156 × 3 ÷ 4 − 48) = 69 °C

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2025.

Automatic transmission fluid temperature VENUE_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.

Automatic transmission fluid temperature VENUE_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Barometric pressure VENUE_BAROMETRIC_PRESSURE

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 kPa
Unit
kPa

In testing for 2019 to 2026.

Boost pressure VENUE_BOOST_P

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
(val × 1372549 ÷ 100000)
Range
0 to 3499.9999
Unit
Raw value

In testing for 2019 to 2026.

Boost regulator duty VENUE_BOOST_REGULATOR_DUTY

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2022.

Catalyst damaging misfires total all cylinders VENUE_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Catalyst damaging misfires total, cylinder 1 VENUE_CATALYST_DAMAGING_MISFIRES_TOTAL_C1

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Catalyst damaging misfires total, cylinder 2 VENUE_CATALYST_DAMAGING_MISFIRES_TOTAL_C2

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Catalyst damaging misfires total, cylinder 3 VENUE_CATALYST_DAMAGING_MISFIRES_TOTAL_C3

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Catalyst damaging misfires total, cylinder 4 VENUE_CATALYST_DAMAGING_MISFIRES_TOTAL_C4

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Clutch solenoid duty VENUE_CLUTCH_SOLENOID_DUTY

  • Request21 C0
  • Service 21PID C0
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2019 to 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2025. Supported for 2022.

Commanded throttle actuator VENUE_COMMANDED_THROTTLE_ACTUATOR

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.390625)
Range
0 to 99.6 %
Unit
%

In testing for 2019 to 2026.

Commanded torque VENUE_COMMANDED_TORQUE

  • Request21 C0
  • Service 21PID C0
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 N·m
Unit
N·m

In testing for 2019 to 2026.

Coolant) VENUE_COOLANT_FAN_PWM

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026.

Diesel particulate filter differential pressure VENUE_DPF_DIFF_P

  • Request22 E0 F1
  • Service 22DID E0F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 255 of the reply, 8 bits.

Formula
(val × 431373 ÷ 100000 − 100)
Range
-100 to 1000.0011
Unit
Raw value

In testing for 2019 to 2026.

Diesel particulate filter differential pressure VENUE_DPF_DIFFERENTIAL_PRESSURE

  • Request21 1B
  • Service 21PID 1B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767.5
Unit
Raw value

In testing for 2019 to 2026.

Diesel particulate filter load, from model VENUE_DPF_LOAD_MODEL

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026.

Diesel particulate filter regen demand counter VENUE_DPF_REGEN_DEMAND_CNT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 432 to 439 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Diesel particulate filter regen success state VENUE_DPF_REGEN_SUCCESS_ST

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bit 407 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026.

Diesel particulate filter regen, completed state VENUE_DPF_REGEN_COMPLETED

  • Request22 ED 06
  • Service 22DID ED06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Diesel particulate filter regeneration state VENUE_DPF_REGENERATION_STATE

  • Request21 06
  • Service 21PID 06
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 207 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026.

Emission relevant misfires total all cylinders VENUE_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Emission relevant misfires total, cylinder 1 VENUE_EMISSION_RELEVANT_MISFIRES_TOTAL_C1

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Emission relevant misfires total, cylinder 2 VENUE_EMISSION_RELEVANT_MISFIRES_TOTAL_C2

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Emission relevant misfires total, cylinder 3 VENUE_EMISSION_RELEVANT_MISFIRES_TOTAL_C3

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Emission relevant misfires total, cylinder 4 VENUE_EMISSION_RELEVANT_MISFIRES_TOTAL_C4

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Engine coolant temperature VENUE_ENGINE_COOLANT_T

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2019 to 2024, 2026. Not supported for 2025.

Engine oil temperature VENUE_ENGINE_OIL_T

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2019 to 2024, 2026. Not supported for 2025.

Engine oil temperature VENUE_EOTConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 272 to 279 of the reply, 8 bits.

0x9C = 156 → (156 × 3 ÷ 4 − 48) = 69 °C

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Engine oil temperature VENUE_EOT_V2

  • Request22 ED 02
  • Service 22DID ED02
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val − 4)
Range
-4 to 251 °C
Unit
°C

In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.

Engine RPM VENUE_ENGINE_RPM_TCM

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.

Engine RPM VENUE_RPM

  • Request21 C0
  • Service 21PID C0
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2019 to 2026.

Exhaust gas flow in the particulate filter VENUE_EXH_GAS_FLOW_PF

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 256 to 263 of the reply, 8 bits.

Formula
(val × 392157 ÷ 50)
Range
0 to 2000000.7 L
Unit
L

In testing for 2019 to 2026.

Exhaust gas temperature VENUE_EXHAUST_GAS_T

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
(val × 4.709803922 + 99)
Range
99 to 1300 °C
Unit
°C

In testing for 2019 to 2026.

Exhaust gas temperature at catalyst VENUE_EXH_GAS_T_CAT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val × 471 ÷ 100 + 99)
Range
0 to 1300.05 °C
Unit
°C

In testing for 2019 to 2026.

Gasoline direct injection time bank a, 1 VENUE_GDI_IT_A1

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2019 to 2026.

Gasoline direct injection time bank a, 2 VENUE_GDI_IT_A2

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2019 to 2026.

Gasoline direct injection time bank a, 3 VENUE_GDI_IT_A3

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2019 to 2026.

Gasoline direct injection time bank a, 4 VENUE_GDI_IT_A4

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2019 to 2026.

Gasoline direct injection time bank b, 1 VENUE_GDI_IT_B1

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2019 to 2026.

Gasoline direct injection time bank b, 2 VENUE_GDI_IT_B2

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2019 to 2026.

Gasoline direct injection time bank b, 3 VENUE_GDI_IT_B3

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2019 to 2026.

Gasoline direct injection time bank b, 4 VENUE_GDI_IT_B4

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2019 to 2026.

Glow relay duty VENUE_GLOW_RELAY_DUTY

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
(val × 2451 ÷ 6250)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026.

Heat VENUE_HEAT

  • Request21 C0
  • Service 21PID C0
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2019 to 2026.

Idle control mode VENUE_IDLE_CONTROL_MODE

  • Request21 00
  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Injection duration cylinder 1 VENUE_INJ_DUR_1Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

0x0026 = 38 → (38 ÷ 1220.7) = 0.03113 s

Formula
(val ÷ 1220.7)
Range
0 to 53 s
Unit
s

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Injection duration cylinder 2 VENUE_INJ_DUR_2Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

0x0026 = 38 → (38 ÷ 1220.7) = 0.03113 s

Formula
(val ÷ 1220.7)
Range
0 to 53 s
Unit
s

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Injection duration cylinder 3 VENUE_INJ_DUR_3Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

0x0026 = 38 → (38 ÷ 1220.7) = 0.03113 s

Formula
(val ÷ 1220.7)
Range
0 to 53 s
Unit
s

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Injection duration cylinder 4 VENUE_INJ_DUR_4Confirmed

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

0x0026 = 38 → (38 ÷ 1220.7) = 0.03113 s

Formula
(val ÷ 1220.7)
Range
0 to 53 s
Unit
s

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Intake air temperature VENUE_EITConfirmed

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 264 to 271 of the reply, 8 bits.

0x47 = 71 → (71 × 3 ÷ 4 − 48) = 5.25 °C

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Intake air temperature VENUE_INTAKE_AIR_T

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2019 to 2024, 2026. Not supported for 2025.

Knock detected VENUE_KNOCK_DETECTED

  • Request21 00
  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Knock learn, cylinder 1 VENUE_KNOCK_LEARN_1Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 160 to 167 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Knock learn, cylinder 2 VENUE_KNOCK_LEARN_2Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 168 to 175 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Knock learn, cylinder 3 VENUE_KNOCK_LEARN_3Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 176 to 183 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Knock learn, cylinder 4 VENUE_KNOCK_LEARN_4Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 184 to 191 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Knock retard cylinder 1 VENUE_KNOCK_RETARD_CYL_1

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2019 to 2026.

Knock retard cylinder 1, alternate VENUE_KNOCK_RETARD_1_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2019 to 2026.

Knock retard cylinder 1, alternate VENUE_KNOCK_RETARD_CYL_1_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2019 to 2026.

Knock retard cylinder 2 VENUE_KNOCK_RETARD_CYL_2

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2019 to 2026.

Knock retard cylinder 2, alternate VENUE_KNOCK_RETARD_2_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2019 to 2026.

Knock retard cylinder 2, alternate VENUE_KNOCK_RETARD_CYL_2_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2019 to 2026.

Knock retard cylinder 3 VENUE_KNOCK_RETARD_CYL_3

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2019 to 2026.

Knock retard cylinder 3, alternate VENUE_KNOCK_RETARD_3_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2019 to 2026.

Knock retard cylinder 3, alternate VENUE_KNOCK_RETARD_CYL_3_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2019 to 2026.

Knock retard cylinder 4 VENUE_KNOCK_RETARD_CYL_4

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2019 to 2026.

Knock retard cylinder 4, alternate VENUE_KNOCK_RETARD_4_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2019 to 2026.

Knock retard cylinder 4, alternate VENUE_KNOCK_RETARD_CYL_4_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2019 to 2026.

Knock retard, cylinder 1 VENUE_KNOCK_RETARD_1Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 96 to 103 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Knock retard, cylinder 2 VENUE_KNOCK_RETARD_2Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 104 to 111 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Knock retard, cylinder 3 VENUE_KNOCK_RETARD_3Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 112 to 119 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Knock retard, cylinder 4 VENUE_KNOCK_RETARD_4Confirmed

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 120 to 127 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 ÷ 5) = 0 °

Formula
(val ÷ 5)
Range
-25 to 25 °
Unit
°

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Lock switch VENUE_LOCK_SWITCH

  • Request21 C0
  • Service 21PID C0
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bit 151 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026.

Main injection volume VENUE_MAIN_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 0.392156863)
Range
0 to 100 L
Unit
L

In testing for 2019 to 2026.

Malfunction indicator VENUE_MALFUNCTION_INDICATOR

  • Request21 C0
  • Service 21PID C0
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026.

Misfires, current, cylinder 1 VENUE_MISFIRES_C1_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires, current, cylinder 2 VENUE_MISFIRES_C2_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires, current, cylinder 3 VENUE_MISFIRES_C3_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires, current, cylinder 4 VENUE_MISFIRES_C4_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

NOx trap outlet pressure VENUE_NOX_TRAP_OUTLET_P

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 288 to 295 of the reply, 8 bits.

Formula
(val × 3212451 ÷ 25000)
Range
0 to 32767.0002
Unit
Raw value

In testing for 2019 to 2026.

Output speed VENUE_OUTPUT_SPEED

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 88 to 103 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.

Pilot injection volume VENUE_PILOT_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2019 to 2026.

Post injection volume VENUE_POST_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2019 to 2026.

Pressure sensor VENUE_PRESSURE_SENSOR

  • Request21 C0
  • Service 21PID C0
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 bar
Unit
bar

In testing for 2019 to 2026.

Requested torque VENUE_REQUESTED_TORQUE

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 0.001526)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2025. Supported for 2022.

Throttle position #1 VENUE_THROTTLE_POSITION__1

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.0244140625)
Range
-800 to 799 %
Unit
%

In testing for 2019 to 2026.

Throttle position #2 VENUE_THROTTLE_POSITION__2

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.0244140625)
Range
-800 to 799 %
Unit
%

In testing for 2019 to 2026.

Timing advance #1 VENUE_TIMING_ADVANCE_1

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2019 to 2026.

Timing advance #2 VENUE_TIMING_ADVANCE_2

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2019 to 2026.

Timing advance #3 VENUE_TIMING_ADVANCE_3

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2019 to 2026.

Timing advance #4 VENUE_TIMING_ADVANCE_4

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2019 to 2026.

Torque converter slip VENUE_TORQUE_CONVERTER_SLIP

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.

Torque converter slip VENUE_TORQUE_CONVERTER_SLIP_7E1

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2019 to 2026.

Turbine speed VENUE_TURBINE_SPEED

  • Request21 A0
  • Service 21PID A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.

Turbo boost pressure VENUE_TB_PRES

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 0.008291)
Range
0 to 543 kPa
Unit
kPa

In testing for 2019 to 2024, 2026. Not supported for 2025.

Variable valve timing temperature VENUE_CVVT_T

Continuously variable valve timing temperature.

  • Request21 18
  • Service 21PID 18
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val − 48)
Range
-48 to 207 °C
Unit
°C

In testing for 2019 to 2026.

Waste gate duty VENUE_WG_DUTY

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val × 0.00305176)
Range
0 to 199 %
Unit
%

In testing for 2019 to 2024, 2026. Not supported for 2025.

Waste gate position VENUE_WG_POS

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399 %
Unit
%

In testing for 2019 to 2024, 2026. Not supported for 2025.

Waste gate set point VENUE_WG_SP

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399 %
Unit
%

In testing for 2019 to 2024, 2026. Not supported for 2025.

Waste gate voltage VENUE_WG_V

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val × 0.000152588)
Range
0 to 9.99 V
Unit
V

In testing for 2019 to 2024, 2026. Not supported for 2025.

Engine › Misfires

Emission-relevant misfires, cylinder #1 VENUE_MIS_CNT_EMIS_1

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Emission-relevant misfires, cylinder #2 VENUE_MIS_CNT_EMIS_2

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Emission-relevant misfires, cylinder #3 VENUE_MIS_CNT_EMIS_3

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Emission-relevant misfires, cylinder #4 VENUE_MIS_CNT_EMIS_4

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires harmful for catalyst cylinder 1 VENUE_MIS_CAT_1

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires harmful for catalyst cylinder 2 VENUE_MIS_CAT_2

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires harmful for catalyst cylinder 3 VENUE_MIS_CAT_3

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires harmful for catalyst cylinder 4 VENUE_MIS_CAT_4

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires total counter, all cylinders VENUE_MIS_CNT_ALL

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires total counter, cylinder #1 VENUE_MIS_CNT_1

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires total counter, cylinder #2 VENUE_MIS_CNT_2

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires total counter, cylinder #3 VENUE_MIS_CNT_3

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires total counter, cylinder #4 VENUE_MIS_CNT_4

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires, cylinder 1 VENUE_MIS_1

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires, cylinder 2 VENUE_MIS_2

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires, cylinder 3 VENUE_MIS_3

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires, cylinder 4 VENUE_MIS_4

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Engine › OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2025.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.