Fuel parameters
The Hyundai Venue has 12 fuel parameters.
● Confirmed◆ In testing○ Supported× Not supported
Fuel consumption VENUE_FUEL_CONS
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 25647 ÷ 20000)- Range
- 0 to 326.9992 L
- Unit
- L
In testing for 2019 to 2026.
Fuel cut VENUE_FUEL_CUT
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2026.
Fuel injection timing #1 VENUE_FUEL_INJECTION_TIMING_1
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
In testing for 2019 to 2026.
Fuel injection timing #2 VENUE_FUEL_INJECTION_TIMING_2
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
In testing for 2019 to 2026.
Fuel injection timing #3 VENUE_FUEL_INJECTION_TIMING_3
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
In testing for 2019 to 2026.
Fuel injection timing #4 VENUE_FUEL_INJECTION_TIMING_4
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
In testing for 2019 to 2026.
Fuel level, volume VENUE_FLI_VOLConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 B0 02 - Service 22
DID B002 - Module
7C6 → 7CE - Every
30 s - Testing for 2019 to 2021, 2023 to 2024, 2026
Example reply from a 2025 Hyundai Venue.
Bits 32 to 39 of the reply, 8 bits.
0x48 = 72 → (72 ÷ 2) = 36 L
- Formula
(val ÷ 2)- Range
- 0 to 127.5 L
- Unit
- L
Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.
Fuel pressure VENUE_FUEL_P
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 980392157 ÷ 100000)- Range
- 0 to 2500000
- Unit
- Raw value
In testing for 2019 to 2026.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022, 2025.
Fuel temperature VENUE_FUEL_T
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val × 98 ÷ 125 − 50)- Range
- -50 to 149.9199 °C
- Unit
- °C
In testing for 2019 to 2026.
Short term fuel % trim, bank 1 VENUE_STFT_B1
- Request
21 15 - Service 21
PID 15 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 32768 − 100)- Range
- 0 to 99.99 %
- Unit
- %
In testing for 2019 to 2026.
Short term fuel % trim, bank 1 idle VENUE_STFT_B1_IDLE
- Request
21 15 - Service 21
PID 15 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.046875)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2026.