Aux battery state of charge VENUE_AUX_SOCConfirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 320 to 327 of the reply, 8 bits.

0x00 = 0 → 0 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12v battery charge VENUE_VPWR_V3

  • Request22 E0 04
  • Service 22DID E004
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022, 2025.

Aux battery state of charge VENUE_AUX_SOCConfirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 320 to 327 of the reply, 8 bits.

0x00 = 0 → 0 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Aux battery state of health VENUE_AUX_SOHConfirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bits 328 to 335 of the reply, 8 bits.

0x00 = 0 → 0 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Control module voltage VENUE_CONTROL_MODULE_VOLTAGE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2019 to 2024, 2026. Not supported for 2025.

Control module voltage after ignition VENUE_CONTROL_MODULE_VOLTAGE_AFTER_IGNITION

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

In testing for 2019 to 2024, 2026. Not supported for 2025.

Coolant temperature sensor voltage VENUE_COOLANT_T_SENSOR_VOLTAGE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0048828125)
Range
0 to 319 V
Unit
V

In testing for 2019 to 2024, 2026. Not supported for 2025.

IAT sensor voltage VENUE_IAT_SENSOR_VOLTAGE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0048828125)
Range
0 to 319 V
Unit
V

In testing for 2019 to 2024, 2026. Not supported for 2025.

Manifold absolute pressure sensor voltage VENUE_MAP_SENSOR_VOLTAGE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0048828125)
Range
0 to 319 V
Unit
V

In testing for 2019 to 2024, 2026. Not supported for 2025.

Relative accelerator pedal position voltage VENUE_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 5)
Range
-6553.6 to 6553.4 V
Unit
V

In testing for 2019 to 2026.

Supply voltage VENUE_SUPPLY_VOLTAGE

  • Request21 C0
  • Service 21PID C0
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2019 to 2026.

System voltage VENUE_SYSTEM_VOLTAGE

  • Request21 C0
  • Service 21PID C0
  • Module7E5 → 7ED
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2019 to 2026.

Throttle position sensor voltage #1 VENUE_THROTTLE_POSITION_SENSOR_VOLTAGE__1

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0012207031)
Range
0 to 79 V
Unit
V

In testing for 2019 to 2026.

Throttle position sensor voltage #2 VENUE_THROTTLE_POSITION_SENSOR_VOLTAGE__2

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0012207031)
Range
0 to 79 V
Unit
V

In testing for 2019 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.