Hyundai Venue

Climate parameters

The Hyundai Venue has 4 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Defog light VENUE_DEFOG_LIGHTConfirmed

  • Request22 BC 07
  • Service 22DID BC07
  • Module770 → 778
  • Every1 s
  • Testing for 2019 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bit 47 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2025. In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Defog light VENUE_DEFOG_LIGHTConfirmed

  • Request22 BC 07
  • Service 22DID BC07
  • Module770 → 778
  • Every1 s
  • Testing for 2019 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bit 47 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2025. In testing for 2019 to 2021, 2023 to 2024, 2026. Not supported for 2022.

Defogging? VENUE_DEFOG_SWConfirmed

  • Request22 BC 03
  • Service 22DID BC03
  • Module770 → 778
  • Every1 s
  • Testing for 2019 to 2021, 2023 to 2024, 2026

Example reply from a 2025 Hyundai Venue.

Bit 62 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022, 2025. In testing for 2019 to 2021, 2023 to 2024, 2026.

Interior temperature, passenger legs vent VENUE_HVAC_IAT_PASSENGER_LEGS_VENT

  • Request22 01 01
  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2019 to 2026.

Interior temperature, passenger vent VENUE_HVAC_IAT_PASSENGER_VENT

  • Request22 01 01
  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2019 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.