Climate parameters
The Ford F-250 has 9 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/C compressor pressure F250_AC_PConfirmed
- Request
22 03 93 - Service 22
DID 0393 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2010, 2012 to 2015, 2018 to 2026
Example reply from a 2017 Ford F-250.
Bits 0 to 15 of the reply, 16 bits.
0x014B = 331 → (331 × 245251 ÷ 845473) = 96.014989 psi
- Formula
(val × 245251 ÷ 845473)- Range
- 0 to 1000 psi
- Unit
- psi
Confirmed for 2011, 2016 to 2017. In testing for 1999, 2002 to 2005, 2007 to 2009, 2012 to 2015, 2018. Not supported for 2000 to 2001, 2006, 2010, 2019 to 2026.
A/C compressor pressure sensor voltage F250_AC_P_SENS_VConfirmed
- Request
22 98 00 - Service 22
DID 9800 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2010, 2012 to 2016, 2018
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 1024)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2011, 2017, 2019 to 2026. In testing for 1999, 2002 to 2009, 2012 to 2016, 2018. Not supported for 2000 to 2001, 2010.
A/C compressor, state F250_AC_STATEConfirmed
- Request
22 09 9B - Service 22
DID 099B - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2010, 2012 to 2016, 2018, 2020, 2024
Example reply from a 2026 Ford F-250.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2011, 2017, 2019, 2021 to 2023, 2025 to 2026. In testing for 1999, 2001 to 2009, 2012 to 2016, 2018. Not supported for 2000, 2010, 2020, 2024.
A/C refrigerant pressure F250_PCM_A_C_REFRIG_PConfirmed
- Request
22 06 04 - Service 22
DID 0604 - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2016, 2018
Example reply from a 2026 Ford F-250.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x00B3 = 179 → 179 kPa
- Formula
val- Range
- -32768 to 32767 kPa
- Unit
- kPa
Confirmed for 2017, 2019 to 2026. In testing for 1999, 2001 to 2009, 2012 to 2016, 2018. Not supported for 2000, 2010 to 2011.
Ambient air temperature AATSAE J1979Confirmed
- Request
01 46 - Service 01
PID 46 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017, 2022. Supported for 2011, 2016, 2018 to 2021, 2023 to 2026.
Ambient temperature sensor voltage F250_AAT_VConfirmed
- Request
22 03 BA - Service 22
DID 03BA - Module
7E0 → 7E8 - Every
1 s - Testing for 1999 to 2010, 2012 to 2015, 2018
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 1023)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2011, 2016 to 2017, 2019 to 2026. In testing for 1999, 2001 to 2005, 2007 to 2009, 2012 to 2015, 2018. Not supported for 2000, 2006, 2010.
Ambient temperature, alternate F250_AAT_ALTConfirmed
- Request
22 05 7D - Service 22
DID 057D - Module
7E0 → 7E8 - Every
5 s - Testing for 1999 to 2016, 2018 to 2020, 2024
Example reply from a 2026 Ford F-250.
Bits 0 to 7 of the reply, 8 bits.
0x7C = 124 → (124 ÷ 2 − 40) = 22 °C
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
Confirmed for 2017, 2021 to 2023, 2025 to 2026. In testing for 1999, 2001 to 2009, 2012 to 2016, 2018. Not supported for 2000, 2010 to 2011, 2019 to 2020, 2024.
Exterior temperature F250_AAT
- Request
22 DD 05 - Service 22
DID DD05 - Module
7E2 → 7EA - Every
5 s - Testing for 1999 to 2018, 2020 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1999 to 2005, 2007 to 2009, 2012 to 2015, 2018. Supported for 2019. Not supported for 2006, 2010 to 2011, 2016 to 2017, 2020 to 2026.
Interior temperature F250_IAT
- Request
22 DD 04 - Service 22
DID DD04 - Module
7E2 → 7EA - Every
5 s - Testing for 1999 to 2018, 2020 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1999 to 2005, 2007 to 2009, 2012 to 2015, 2018. Supported for 2019. Not supported for 2006, 2010 to 2011, 2016 to 2017, 2020 to 2026.