Volvo S90

Connectable parameters

The Volvo S90 has 49 Connectables, parameters that Pelican can monitor automatically.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

High voltage battery state of charge VOLVO_HVBAT_ST_CHG

Pelican can show this parameter as the state of charge.

  • Request22 48 01
  • Service 22DID 4801
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 500)
Range
0 to 131 %
Unit
%

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

State of charge

High voltage battery state of charge VOLVO_HVBAT_ST_CHG

Pelican can show this parameter as the state of charge.

  • Request22 48 01
  • Service 22DID 4801
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 500)
Range
0 to 131 %
Unit
%

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

HV battery state of charge VOLVO_EQA_HV_SOC

Pelican can show this parameter as the state of charge.

  • Request22 60 50
  • Service 22DID 6050
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

State of charge VOLVO_SOC_V2

Pelican can show this parameter as the state of charge.

  • Request21 08
  • Service 21PID 08
  • Module79B → 7BB
  • Every10 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095.9375 %
Unit
%

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

State of health

High voltage battery state of health VOLVO_HVBAT_ST_HEALTH

Pelican can show this parameter as the state of health.

  • Request22 49 6D
  • Service 22DID 496D
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 100)
Range
0 to 42949672 %
Unit
%

In testing for 2016 to 2024.

State of health VOLVO_SOH

Pelican can show this parameter as the state of health.

  • Request21 61
  • Service 21PID 61
  • Module79B → 7BB
  • Every60 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 %
Unit
%

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Plug state

Charging plug detected VOLVO_PLUG

Pelican can show this parameter as the plug state.

  • Request22 33 9D
  • Service 22DID 339D
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Fuel tank level

Fuel level input VOLVO_FLI_INPUT

Pelican can show this parameter as the fuel tank level.

  • Request22 F4 2F
  • Service 22DID F42F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Electric range

HV battery remaining distance VOLVO_EQA_HV_RANGE

Pelican can show this parameter as the electric range.

  • Request22 65 02
  • Service 22DID 6502
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 1000 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Fuel range

Distance to empty VOLVO_DIST_EMPTY_MS_CAN

Pelican can show this parameter as the fuel range.

  • Request22 EE FD
  • Service 22DID EEFD
  • Module720
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer

Odometer VOLVO_ODO_DIM

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module720
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_CEM

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module726
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_PSCM

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module730
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_PAM

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module736
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_SRS

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module737
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_DDM_MS_CAN

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module740
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_PDM_MS_CAN

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module741
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_PBM

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module756
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_BCM

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module760
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_FSM

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module764
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_CVM

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module793
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_PPM

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module794
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_SAS

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module797
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_MILEAGE_ODO

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_TCM

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • Module7E1
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • ModuleD016 → 1EC64E80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Odometer VOLVO_ODO_V2

Pelican can show this parameter as the odometer.

  • Request22 61 BB
  • Service 22DID 61BB
  • ModuleD018 → 1F002E80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2024.

Total distance VOLVO_DEM_ODO

Pelican can show this parameter as the odometer.

  • Request22 DD 01
  • Service 22DID DD01
  • ModuleD016 → 1EC70E80
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Commanded lambda

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2018. Supported for 2017, 2019 to 2020.

Distance since trouble codes were cleared

Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed

Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.

Pelican can show this parameter as the distance since trouble codes were cleared.

  • Request01 31
  • Service 01PID 31
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2017. Supported for 2018 to 2020.

Engine coolant temperature

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017 to 2018. Supported for 2019 to 2020.

Engine load

Calculated load VOLVO_CALC_LOAD

Pelican can show this parameter as the engine load.

  • Request22 F4 04
  • Service 22DID F404
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Engine oil temperature

Engine oil temperature VOLVO_EOT_V2

Pelican can show this parameter as the engine oil temperature.

  • Request22 D9 DC
  • Service 22DID D9DC
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Engine oil temperature VOLVO_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request22 EE 58
  • Service 22DID EE58
  • ModuleD016 → 1EC60E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Short term fuel trim

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2018. Supported for 2017, 2019 to 2020.

Starter battery voltage

12V system voltage, hd VOLVO_EQA_AUX_V_HD

Pelican can show this parameter as the starter battery voltage.

  • Request22 02 01
  • Service 22DID 0201
  • Module624 → 5A4
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 1000 ÷ 10000)
Range
0 to 100 V
Unit
V

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Auxiliary battery voltage VOLVO_EQA_AUX_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 20 05
  • Service 22DID 2005
  • Module7E5
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25.9 ÷ 255)
Range
0 to 25.9 V
Unit
V

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Battery voltage VOLVO_BAT_V_726

Pelican can show this parameter as the starter battery voltage.

  • Request22 40 2A
  • Service 22DID 402A
  • Module726
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 20 + 6)
Range
0 to 18.75 V
Unit
V

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Battery voltage VOLVO_BAT_V

Pelican can show this parameter as the starter battery voltage.

  • Request22 40 CD
  • Service 22DID 40CD
  • ModuleD01A → 1F402E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 40 + 5)
Range
0 to 1643 V
Unit
V

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2017. Supported for 2018 to 2020.

Throttle position

Throttle absolute position VOLVO_THROTTLE_ABS_POS

Pelican can show this parameter as the throttle position.

  • Request22 F4 11
  • Service 22DID F411
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Traction battery current

High voltage battery current VOLVO_HVBAT_CURRENT

Pelican can show this parameter as the traction battery current.

  • Request22 48 02
  • Service 22DID 4802
  • ModuleD016 → 1EC6AE80
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-655 to 655 A
Unit
A

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

HV battery current VOLVO_HV_A

Pelican can show this parameter as the traction battery current.

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
(val × -1 ÷ 32)
Range
-1023.9687 to 1024 A
Unit
A

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Traction battery voltage

High voltage battery voltage VOLVO_HVBAT_V

Pelican can show this parameter as the traction battery voltage.

  • Request22 48 03
  • Service 22DID 4803
  • ModuleD016 → 1EC6AE80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

HV battery voltage VOLVO_HV_V

Pelican can show this parameter as the traction battery voltage.

  • Request21 07
  • Service 21PID 07
  • Module79B → 7BB
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.9843 V
Unit
V

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Transmission fluid temperature

Transmission fluid temperature VOLVO_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 1E 3F
  • Service 22DID 1E3F
  • Module7E1
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 4)
Range
-8192 to 8191 °C
Unit
°C

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Transmission fluid temperature VOLVO_ATF_T_D016_2

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 D9 00
  • Service 22DID D900
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 1000)
Range
-32768000 to 32767000 °C
Unit
°C

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Transmission fluid temperature VOLVO_ATF_T_D016

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 D9 0D
  • Service 22DID D90D
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 °C
Unit
°C

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Transmission fluid temperature VOLVO_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 DA 3B
  • Service 22DID DA3B
  • ModuleD016 → 1EC64E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.

Transmission fluid temperature VOLVO_ATF_T_DA18

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 E0 04
  • Service 22DID E004
  • ModuleDA18 → 18
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2016 to 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.