Engine parameters
The Volvo S90 has 259 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
- pedal position sensor VOLVO_PEDAL_POS_SENS
- Request
22 2B 35 - Service 22
DID 2B35 - Module
760 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 25)- Range
- 0 to 2621 mm
- Unit
- mm
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Accelerator pedal position VOLVO_M3_APP_ECM
- Request
22 F4 49 - Service 22
DID F449 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Actual power VOLVO_ACT_POWER
- Request
22 4A 88 - Service 22
DID 4A88 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 kW
- Unit
- kW
In testing for 2016 to 2024.
Adaptive cruise target vehicle VOLVO_ACC_TARGETVEHICLE
- Request
22 DA 12 - Service 22
DID DA12 - Module
720 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Adaptive cruise time gap VOLVO_ACC_TIMEGAP
- Request
22 DA 11 - Service 22
DID DA11 - Module
720 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 2 + 0.5)- Range
- 0 to 128 s
- Unit
- s
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Air conditioning compressor module A current VOLVO_AC_COMP_MODULE
- Request
22 03 31 - Service 22
DID 0331 - Module
D016 → 1EC04E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 A
- Unit
- A
In testing for 2016 to 2024.
Air conditioning compressor module a status VOLVO_AC_COMP_MODULE_STAT
- Request
22 03 2F - Service 22
DID 032F - Module
D016 → 1EC04E80 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2024.
Air conditioning pressure VOLVO_AC_P
- Request
22 EE 34 - Service 22
DID EE34 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 2)- Range
- -65536 to 65534 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Air conditioning pressure VOLVO_AC_P_V2
- Request
22 D9 00 - Service 22
DID D900 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Air conditioning relay VOLVO_AC_RELAY
- Request
22 D9 09 - Service 22
DID D909 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Air distribution damper motor wanted position VOLVO_AIR_DISTRIBUTION
- Request
22 D9 04 - Service 22
DID D904 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Air distribution damper motor, actual position VOLVO_AIR_DISTRIBUTION_ACT
- Request
22 D9 09 - Service 22
DID D909 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Air flow/cycle, mg/s VOLVO_AIR_FLOW_CYCLE_MG_S
- Request
22 D9 16 - Service 22
DID D916 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Air mass, desired VOLVO_AIR_MASS_DES
- Request
22 D9 1F - Service 22
DID D91F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Air quality sensor status VOLVO_AIR_QUALITY_SENS
- Request
22 DC F9 - Service 22
DID DCF9 - Module
733 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
All-wheel drive coupling current VOLVO_HALDEX_CURRENT
- Request
22 19 45 - Service 22
DID 1945 - Module
795 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
All-wheel drive coupling current VOLVO_HALDEX_CURRENT_795
- Request
22 19 46 - Service 22
DID 1946 - Module
795 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
All-wheel drive coupling module temperature sensor 1 VOLVO_HALDEX_ECU_T_SENS_1
- Request
22 D1 16 - Service 22
DID D116 - Module
795 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
All-wheel drive coupling module temperature sensor 2 VOLVO_HALDEX_ECU_T_SENS_2
- Request
22 D9 00 - Service 22
DID D900 - Module
795 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
All-wheel drive coupling oil temperature VOLVO_HALDEX_OIL_T
- Request
22 FD 04 - Service 22
DID FD04 - Module
795 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 60)- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
All-wheel drive coupling pressure VOLVO_HALDEX_P
- Request
22 19 44 - Service 22
DID 1944 - Module
795 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
All-wheel drive coupling rear axle torque VOLVO_HALDEX_REAR_AXLE_TQ
- Request
22 D9 30 - Service 22
DID D930 - Module
795 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
All-wheel drive coupling rear axle torque, requested VOLVO_HALDEX_REAR_AXLE_TQ_REQ
- Request
22 D9 53 - Service 22
DID D953 - Module
795 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Alternator control mode VOLVO_ALTERNATOR_CTRL_MODE
- Request
22 40 D1 - Service 22
DID 40D1 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Alternator, amps VOLVO_ALTERNATOR_AMPS
- Request
22 D9 24 - Service 22
DID D924 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Automatic alignment offset VOLVO_AUTOMATIC_ALIGNMENT
- Request
22 A2 20 - Service 22
DID A220 - Module
764 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °
- Unit
- °
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Average charging time left VOLVO_AVG_CHG_TIME_LEFT
- Request
22 EE B6 - Service 22
DID EEB6 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery management sensor reliable VOLVO_BAT_MANAGEMENT_SENS
- Request
22 41 A7 - Service 22
DID 41A7 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Bonnet closed VOLVO_BONNET_CLOSED
- Request
22 C1 54 - Service 22
DID C154 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Boost air pressure after turbocharger VOLVO_BOOST_AIR_P_AFTER
- Request
22 03 3E - Service 22
DID 033E - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Boost air temperature VOLVO_BOOST_AIR_T
- Request
22 03 41 - Service 22
DID 0341 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 ÷ 8 − 40)- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Boost air temperature VOLVO_BOOST_AIR_T_7E0
- Request
22 03 41 - Service 22
DID 0341 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 ÷ 8 − 40)- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Boost pressure VOLVO_BOOST_P
- Request
22 D9 41 - Service 22
DID D941 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Boost pressure, desired value VOLVO_BOOST_P_DES
- Request
22 D9 E4 - Service 22
DID D9E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Boot lid sensor VOLVO_BOOT_LID_SENS
- Request
22 C1 50 - Service 22
DID C150 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 64)- Range
- 0 to 3.98
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Burning time, hours VOLVO_BURNING_TIME_HOURS
- Request
22 9A 0B - Service 22
DID 9A0B - Module
7E3 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Burning time, minutes VOLVO_BURNING_TIME_MINUTES
- Request
22 9A 0B - Service 22
DID 9A0B - Module
7E3 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Calculated load VOLVO_CALC_LOAD
Pelican can show this parameter as the engine load.
- Request
22 F4 04 - Service 22
DID F404 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2017. Supported for 2018 to 2020.
Central lock VOLVO_CENTRAL_LOCK
- Request
22 C2 59 - Service 22
DID C259 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charging VOLVO_CHG_MS_CAN
- Request
22 D9 01 - Service 22
DID D901 - Module
791 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 1)- Range
- -1 to 254
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charging state VOLVO_CHG_ST
- Request
22 EE 1D - Service 22
DID EE1D - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cold zone count VOLVO_CEM_COLD_ZONE
- Request
22 D9 FE - Service 22
DID D9FE - Module
733 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Combustion air fan VOLVO_COMBUSTION_AIR_FAN
- Request
22 9A 06 - Service 22
DID 9A06 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2018. Supported for 2017, 2019 to 2020.
Compressor inlet sensor pressure VOLVO_COMP_INLET_SENS_P
- Request
22 03 03 - Service 22
DID 0303 - Module
D016 → 1EC04E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2016 to 2024.
Compressor inlet sensor temperature VOLVO_COMP_INLET_SENS_T
- Request
22 EE 36 - Service 22
DID EE36 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2016 to 2024.
Compressor inlet sensor temperature VOLVO_COMP_INLET_SENS_T_D016
- Request
22 03 03 - Service 22
DID 0303 - Module
D016 → 1EC04E80 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100 − 40)- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2016 to 2024.
Compressor outlet sensor pressure VOLVO_COMP_OUTLET_SENS_P
- Request
22 03 29 - Service 22
DID 0329 - Module
D016 → 1EC04E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2016 to 2024.
Compressor outlet sensor temperature VOLVO_COMP_OUTLET_SENS_T
- Request
22 EE 38 - Service 22
DID EE38 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2016 to 2024.
Compressor outlet sensor temperature VOLVO_COMP_OUTLET_SENS_T_D016
- Request
22 03 29 - Service 22
DID 0329 - Module
D016 → 1EC04E80 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100 − 40)- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2016 to 2024.
Control module power supply VOLVO_CTRL_MODULE_POWER
- Request
22 D1 11 - Service 22
DID D111 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Control module temperature VOLVO_CTRL_MODULE_T
- Request
22 D9 B8 - Service 22
DID D9B8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 ÷ 8 − 40)- Range
- -40 to 119 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Coolant pump current VOLVO_ED_PUMP_A
- Request
22 23 09 - Service 22
DID 2309 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 5)- Range
- 0 to 51 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Coolant pump relay VOLVO_CLT_PMP_RELAY
- Request
22 D9 5B - Service 22
DID D95B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Coolant pump speed VOLVO_ED_PUMP_DUTY
- Request
22 D0 32 - Service 22
DID D032 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Coolant pump temperature VOLVO_ED_PUMP_T
- Request
22 23 0A - Service 22
DID 230A - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Coolant pump voltage VOLVO_ED_PUMP_V
- Request
22 23 08 - Service 22
DID 2308 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Coolant temperature VOLVO_ED_COOLANT_T
- Request
22 20 47 - Service 22
DID 2047 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8)- Range
- 0 to 8191.875 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cooling fan speed VOLVO_ED_FAN_DUTY
- Request
22 D0 41 - Service 22
DID D041 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Counter VOLVO_CNT_MS_CAN
- Request
22 9A 0D - Service 22
DID 9A0D - Module
7E3 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 1 misfire VOLVO_MIS_1
- Request
22 F6 A2 - Service 22
DID F6A2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 1 misfire average VOLVO_MIS_AVG_1
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 2 misfire VOLVO_MIS_2_V2
- Request
22 F6 A3 - Service 22
DID F6A3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 2 misfire average VOLVO_MIS_AVG_2
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 3 misfire VOLVO_MIS_3_V2
- Request
22 F6 A4 - Service 22
DID F6A4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 3 misfire average VOLVO_MIS_AVG_3
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 4 misfire VOLVO_MIS_4
- Request
22 F6 A5 - Service 22
DID F6A5 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 4 misfire average VOLVO_MIS_AVG_4
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 5 misfire average VOLVO_MIS_AVG_5
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 6 misfire average VOLVO_MIS_AVG_6
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 7 misfire average VOLVO_MIS_AVG_7
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cylinder 8 misfire average VOLVO_MIS_AVG_8
- Request
22 DA B6 - Service 22
DID DAB6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Days since last service VOLVO_DAYS_SINCE_SERVICE
- Request
22 D9 03 - Service 22
DID D903 - Module
D018 → 1F002E80 - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Defroster damper motor wanted position VOLVO_DEFROSTER_DAMPER
- Request
22 D9 00 - Service 22
DID D900 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Defroster damper motor, actual position VOLVO_DEFROSTER_DAMPER_ACT
- Request
22 D9 05 - Service 22
DID D905 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Diesel particulate filter additive pump VOLVO_M3_ADM_ADDITIVE_PMP
- Request
22 D9 04 - Service 22
DID D904 - Module
7C0 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Diesel particulate filter pressure VOLVO_DPF_P
- Request
22 DA C8 - Service 22
DID DAC8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Diesel particulate filter soot VOLVO_DPF_SOOT
- Request
22 D9 F2 - Service 22
DID D9F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Diesel particulate filter temperature VOLVO_DPF_T
- Request
22 D9 F9 - Service 22
DID D9F9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Dipped beam VOLVO_DIPPED_BEAM
- Request
22 71 51 - Service 22
DID 7151 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Display illumination intensity VOLVO_LCD_ILUMINATION
- Request
22 DB 01 - Service 22
DID DB01 - Module
784 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Display temperature VOLVO_DISPLAY_T_MS_CAN
- Request
22 D9 06 - Service 22
DID D906 - Module
784 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Distance to next service VOLVO_EQA_SERVICE_DIST
- Request
22 65 04 - Service 22
DID 6504 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Downtime VOLVO_DOWNTIME
- Request
22 EE D6 - Service 22
DID EED6 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Electric drivetrain coolant temperature, IEM inlet VOLVO_ELEC_DRIVETRAIN_ECT
- Request
22 98 5E - Service 22
DID 985E - Module
D016 → 1EC6EE80 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val − 40)- Range
- -2147483688 to 2147483607 °C
- Unit
- °C
In testing for 2016 to 2024.
Electric drivetrain coolant temperature, IEM outlet VOLVO_ELEC_DRIVETRAIN_ECT_IEM
- Request
22 98 5E - Service 22
DID 985E - Module
D016 → 1EC6EE80 - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The value is signed.
- Formula
(val − 40)- Range
- -2147483688 to 2147483607 °C
- Unit
- °C
In testing for 2016 to 2024.
Electric drivetrain coolant temperature, IHFA inlet VOLVO_ELEC_DRIVETRAIN_ECT_IHFA
- Request
22 98 5E - Service 22
DID 985E - Module
D016 → 1ED24E80 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val − 40)- Range
- -2147483688 to 2147483607 °C
- Unit
- °C
In testing for 2016 to 2024.
Electric drivetrain coolant temperature, IHFA outlet VOLVO_ELEC_DRIVETRAIN_ECT_IHFA_OUTLET
- Request
22 98 5E - Service 22
DID 985E - Module
D016 → 1ED24E80 - Every
5 s - Testing
Bits 32 to 63 of the reply, 32 bits. The value is signed.
- Formula
(val − 40)- Range
- -2147483688 to 2147483607 °C
- Unit
- °C
In testing for 2016 to 2024.
Electric front axle drive torque VOLVO_ELECTRICAL_FRONT
- Request
22 49 D4 - Service 22
DID 49D4 - Module
D016 → 1ED24E80 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val − 1024)- Range
- -2147484672 to 2147482623 N·m
- Unit
- N·m
In testing for 2016 to 2024.
Electric rear axle drive calculated torque VOLVO_ERAD_CALC_TQ
- Request
22 EF 12 - Service 22
DID EF12 - Module
D016 → 1EC6EE80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 4 − 8188)- Range
- -8188 to 253952 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Electric rear axle drive motor winding temperature sensor 1 VOLVO_ERAD_MOTOR_WINDING_T_1
- Request
22 4A 00 - Service 22
DID 4A00 - Module
D016 → 1EC6EE80 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364 °C
- Unit
- °C
In testing for 2016 to 2024.
Electric rear axle drive motor winding temperature sensor 2 VOLVO_ERAD_MOTOR_WINDING_T_2
- Request
22 4A 01 - Service 22
DID 4A01 - Module
D016 → 1EC6EE80 - Every
5 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -214748364 to 214748364 °C
- Unit
- °C
In testing for 2016 to 2024.
Engine coolant fan VOLVO_ENG_CLT_FAN
- Request
22 EE 6F - Service 22
DID EE6F - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2017 to 2018. Supported for 2019 to 2020.
Engine oil pressure VOLVO_EOP
- Request
22 EE 37 - Service 22
DID EE37 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Engine oil pressure VOLVO_EOP_V2
- Request
22 EF 4E - Service 22
DID EF4E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Engine oil temperature VOLVO_EOT
Pelican can show this parameter as the engine oil temperature.
- Request
22 EE 58 - Service 22
DID EE58 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Engine oil temperature VOLVO_EOT_V2
Pelican can show this parameter as the engine oil temperature.
- Request
22 D9 DC - Service 22
DID D9DC - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Engine time since last service VOLVO_ENG_TIME_SINCE
- Request
22 63 0E - Service 22
DID 630E - Module
720 - Every
30 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Engine torque VOLVO_ENG_TQ
- Request
22 DA 89 - Service 22
DID DA89 - Module
D016 → 1EC64E80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 512)- Range
- -512 to 6041 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
ERAD calculated torque VOLVO_ERAD_CALC_TQ_D016
- Request
22 EE 09 - Service 22
DID EE09 - Module
D016 → 1EC6EE80 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 4 − 8188)- Range
- -8188 to 253952 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Evaporator temperature VOLVO_EVAPORATOR_T_MS_CAN
- Request
22 D9 98 - Service 22
DID D998 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 100)- Range
- -100 to 923 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Exhaust gas recirculation bypass valve VOLVO_EGR_BYPASS_VLV
- Request
22 EE 7F - Service 22
DID EE7F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Exhaust gas recirculation cooler bypass actuator position VOLVO_EGR_COOLER_BYPASS
- Request
22 DA D2 - Service 22
DID DAD2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Exhaust gas recirculation valve position sensor VOLVO_EGR_VLV_POS_SENS
- Request
22 DA AD - Service 22
DID DAAD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Exhaust gas recirculation valve, commanded position VOLVO_EGR_VLV_CMD_POS
- Request
22 DC 01 - Service 22
DID DC01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Exhaust gas recirculation valve, commanded position II VOLVO_EGR_VLV_CMD_POS_II
- Request
22 D9 6D - Service 22
DID D96D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fan VOLVO_FAN
- Request
22 DC 02 - Service 22
DID DC02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Front axle sensor VOLVO_FRONT_AXLE_SENS
- Request
22 3B 71 - Service 22
DID 3B71 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.37 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Front oxygen sensor heating VOLVO_FRONT_OXYGEN_SENS
- Request
22 DA 59 - Service 22
DID DA59 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 ms
- Unit
- ms
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Glow plug pulse ratio VOLVO_GLOW_PLUG_RAT_MS_CAN
- Request
22 9A 04 - Service 22
DID 9A04 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Glow plugs VOLVO_GLOW_PLUGS
- Request
22 D9 A0 - Service 22
DID D9A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Grill shutter open VOLVO_GRILL_SHUTTER_OPEN
- Request
22 07 07 - Service 22
DID 0707 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High beam VOLVO_HIGH_BEAM
- Request
22 71 51 - Service 22
DID 7151 - Module
726 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage coolant heater A, inlet temperature VOLVO_HIGH_V_CLT_HEATER_T
- Request
22 03 2B - Service 22
DID 032B - Module
D016 → 1EC04E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 40)- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2016 to 2024.
High voltage coolant heater A, outlet temperature VOLVO_HIGH_V_CLT_HEATER_OUTLET_T
- Request
22 03 2B - Service 22
DID 032B - Module
D016 → 1EC04E80 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100 − 40)- Range
- -40 to 615 °C
- Unit
- °C
In testing for 2016 to 2024.
High voltage ED coolant temperature 2 VOLVO_HIGH_V_ED_ECT_2
- Request
22 EF 73 - Service 22
DID EF73 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage motor coolant pump VOLVO_HIGH_V_MOTOR_CLT_PMP
- Request
22 EF 71 - Service 22
DID EF71 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 rpm
- Unit
- rpm
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage system current VOLVO_HIGH_V_SYSTEM
- Request
22 EF 13 - Service 22
DID EF13 - Module
D016 → 1EC6EE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 250)- Range
- -250 to 260 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage system current VOLVO_HIGH_V_SYSTEM_CURRENT
- Request
22 98 61 - Service 22
DID 9861 - Module
D016 → 1ED24E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 + 40)- Range
- -3236 to 3316 A
- Unit
- A
In testing for 2016 to 2024.
High voltage system current VOLVO_HIGH_V_SYSTEM_V2
- Request
22 98 61 - Service 22
DID 9861 - Module
D016 → 1EC6EE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 + 40)- Range
- -3236 to 3316 A
- Unit
- A
In testing for 2016 to 2024.
Ignition angle before top dead center VOLVO_IGN_ANG_BTDC
- Request
22 F4 0E - Service 22
DID F40E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
In car temperature VOLVO_CAR_T
- Request
22 DD 04 - Service 22
DID DD04 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
In car temperature VOLVO_CAR_T_MS_CAN_7E3
- Request
22 DD 04 - Service 22
DID DD04 - Module
7E3 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
In-car temperature VOLVO_CAR_T_720
- Request
22 DD 04 - Service 22
DID DD04 - Module
720 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
In-car temperature VOLVO_CAR_T_MS_CAN
- Request
22 9A 1B - Service 22
DID 9A1B - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 100)- Range
- -100 to 923 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Infotainment ring optical fiber test VOLVO_MOST_OPTICAL_FIBRE
- Request
22 83 1F - Service 22
DID 831F - Module
784 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Input torque calculated VOLVO_INPUT_TQ_CALC
- Request
22 D9 62 - Service 22
DID D962 - Module
795 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8 − 16376)- Range
- -16376 to 507904 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Input torque, requested VOLVO_INPUT_TQ_REQ
- Request
22 D9 56 - Service 22
DID D956 - Module
795 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8 − 16376)- Range
- -16376 to 507904 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Intake air temperature, manifold sensor VOLVO_TMAP_IAT
- Request
22 D9 AB - Service 22
DID D9AB - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.14)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Lateral angle VOLVO_LATERAL_ANG
- Request
22 2B 0C - Service 22
DID 2B0C - Module
760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °
- Unit
- °
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Leading A/T VOLVO_LEADING_T
- Request
22 1E 2F - Service 22
DID 1E2F - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Left seat heater VOLVO_LEFT_SEAT_HEATER_MS
- Request
22 9A 21 - Service 22
DID 9A21 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Left temperature damper motor wanted position VOLVO_LEFT_T_DAMPER_MOTOR
- Request
22 D9 02 - Service 22
DID D902 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Left temperature damper motor, actual position VOLVO_LEFT_T_DAMPER_MOTOR_ACT
- Request
22 D9 07 - Service 22
DID D907 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Load VOLVO_LOAD
- Request
22 F4 43 - Service 22
DID F443 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 25700 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
M3 APP, CAN VOLVO_M3_APP_CAN
- Request
22 F4 4A - Service 22
DID F44A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
M3 diff.press. VOLVO_M3_DIFF_PRESS
- Request
22 D9 F3 - Service 22
DID D9F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
M3 DPF soot VOLVO_M3_DPF_SOOT
- Request
22 D9 F2 - Service 22
DID D9F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 6.55 g
- Unit
- g
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
M3 EGR DC VOLVO_M3_EGR_DC
- Request
22 D9 6C - Service 22
DID D96C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
M3 IAT, butterfly VOLVO_M3_IAT_BUTTERFLY
- Request
22 F4 0F - Service 22
DID F40F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
M3 IAT, MAF VOLVO_M3_IAT_MAF
- Request
22 D9 1C - Service 22
DID D91C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Misfire catalytic damage total - petrol VOLVO_MIS_CATALYTIC_DAMAGE
- Request
22 DA 03 - Service 22
DID DA03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Misfire emission related total - petrol VOLVO_MIS_EMISSION_RELATED
- Request
22 DA 04 - Service 22
DID DA04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Misfires, cylinder 2 VOLVO_MIS_2
- Request
22 EF 71 - Service 22
DID EF71 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Misfires, cylinder 3 VOLVO_MIS_3
- Request
22 EF 71 - Service 22
DID EF71 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Module current VOLVO_MODULE_CURRENT
- Request
22 19 46 - Service 22
DID 1946 - Module
D016 → 1EC70E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Months since last service VOLVO_MONTHS_SINCE_SERVICE
- Request
22 63 0E - Service 22
DID 630E - Module
720 - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 120)- Range
- 0 to 546
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
MOST lock VOLVO_MOST_LOCK_MS_CAN
- Request
22 DB 16 - Service 22
DID DB16 - Module
784 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
MOST network number of modules VOLVO_MOST_NETWORK_NUM
- Request
22 83 35 - Service 22
DID 8335 - Module
784 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Motor hours since last service VOLVO_MOTOR_HOURS_SINCE
- Request
22 D9 03 - Service 22
DID D903 - Module
D018 → 1F002E80 - Every
30 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 h
- Unit
- h
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Navigation altitude VOLVO_SENSUS_CONNECT_GPS
- Request
22 80 12 - Service 22
DID 8012 - Module
784 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 180)- Range
- 0 to 364 °
- Unit
- °
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Navigation fix VOLVO_SENSUS_CONNECT_GPS_FIX_MS
- Request
22 80 12 - Service 22
DID 8012 - Module
784 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °
- Unit
- °
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Navigation heading VOLVO_SENSUS_CONNECT_GPS_HEADING
- Request
22 80 12 - Service 22
DID 8012 - Module
784 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °
- Unit
- °
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Navigation number of satellites VOLVO_SENSUS_CONNECT_GPS_NUM
- Request
22 80 35 - Service 22
DID 8035 - Module
784 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
On-board charger module temperature VOLVO_OBC_T
- Request
22 EE 19 - Service 22
DID EE19 - Module
D016 → 1EC68E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Operating state VOLVO_OP_ST_MS_CAN
- Request
22 9A 08 - Service 22
DID 9A08 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Outdoor temperature, BCM VOLVO_OUTDOOR_T_BCM
- Request
22 DD 05 - Service 22
DID DD05 - Module
760 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Outside heat exchanger outlet sensor pressure VOLVO_OUTSIDE_HEAT_P
- Request
22 EE 48 - Service 22
DID EE48 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
val- Range
- -2147483648 to 2147483647
- Unit
- Raw value
In testing for 2016 to 2024.
Outside heat exchanger outlet sensor temperature VOLVO_OUTSIDE_HEAT_T
- Request
22 EE 47 - Service 22
DID EE47 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2016 to 2024.
Parking heater counter VOLVO_PARKING_HEATER_CNT
- Request
22 9A 0E - Service 22
DID 9A0E - Module
7E3 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Parking lights VOLVO_PARKING_LIGHTS
- Request
22 71 51 - Service 22
DID 7151 - Module
726 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Passenger airbag activated VOLVO_PASSENGER_AIRBAG_ACTIVATED
- Request
22 5B 29 - Service 22
DID 5B29 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Passenger airbag cutoff switch VOLVO_PASSENGER_AIRBAG
- Request
22 5B 28 - Service 22
DID 5B28 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Passenger airbag OFF lamp VOLVO_PASSENGER_AIRBAG_OFF
- Request
22 61 A5 - Service 22
DID 61A5 - Module
737 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 32)- Range
- 0 to 7.96
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Power mode VOLVO_POWER_MODE
- Request
22 DD 06 - Service 22
DID DD06 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 192)- Range
- -192 to 63
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Power mode VOLVO_POWER_MODE_MS_CAN
- Request
22 DD 07 - Service 22
DID DD07 - Module
784 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 99)- Range
- -99 to 156
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Power mode VOLVO_POWER_MODE_MS_CAN_7E3
- Request
22 DD 06 - Service 22
DID DD06 - Module
7E3 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Quiescent current average VOLVO_QUIESCENT_CURRENT
- Request
22 40 25 - Service 22
DID 4025 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 1000)- Range
- -1000 to 31767 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Rear axle sensor VOLVO_REAR_AXLE_SENS
- Request
22 3B 73 - Service 22
DID 3B73 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 40)- Range
- 0 to 6.37 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Rear defroster automatic VOLVO_REAR_DEFROSTER
- Request
22 D9 18 - Service 22
DID D918 - Module
733 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Rear left seat heater VOLVO_RL_SEAT_HEATER_MS
- Request
22 9A 23 - Service 22
DID 9A23 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Rear oxygen sensor heating VOLVO_REAR_OXYGEN_SENS
- Request
22 DB 77 - Service 22
DID DB77 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 ms
- Unit
- ms
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Rear right seat heater VOLVO_RR_SEAT_HEATER_MS
- Request
22 9A 24 - Service 22
DID 9A24 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Recirculation damper motor wanted position VOLVO_RECIRCULATION_DAMPER
- Request
22 D9 01 - Service 22
DID D901 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Recirculation damper motor, actual position VOLVO_RECIRCULATION_DAMPER_ACT
- Request
22 D9 06 - Service 22
DID D906 - Module
733 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Remote key VOLVO_REMOTE_KEY
- Request
22 41 2D - Service 22
DID 412D - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Right seat heater VOLVO_RIGHT_SEAT_HEATER_MS
- Request
22 9A 22 - Service 22
DID 9A22 - Module
733 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Right temperature damper motor wanted position VOLVO_RIGHT_T_DAMPER_MOTOR
- Request
22 D9 03 - Service 22
DID D903 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Right temperature damper motor, actual position VOLVO_RIGHT_T_DAMPER_MOTOR_ACT
- Request
22 D9 08 - Service 22
DID D908 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Running time, hours VOLVO_RUNNING_TIME_HOURS
- Request
22 9A 0C - Service 22
DID 9A0C - Module
7E3 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Running time, minutes VOLVO_RUNNING_TIME_MINUTES
- Request
22 9A 0C - Service 22
DID 9A0C - Module
7E3 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Seat buckle driver locked VOLVO_SEAT_BUCKLE_DRIVER
- Request
22 5B 19 - Service 22
DID 5B19 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Seat buckle passenger locked VOLVO_SEAT_BUCKLE
- Request
22 5B 1A - Service 22
DID 5B1A - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Seat buckle rear center locked VOLVO_SEAT_BUCKLE_REAR
- Request
22 5B 47 - Service 22
DID 5B47 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Seat buckle rear left locked VOLVO_SEAT_BUCKLE_RL
- Request
22 5B 46 - Service 22
DID 5B46 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Seat buckle rear right locked VOLVO_SEAT_BUCKLE_RR
- Request
22 5B 48 - Service 22
DID 5B48 - Module
737 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Servo control module temperature VOLVO_SERVO_CTRL_MODULE_T
- Request
22 D1 1C - Service 22
DID D11C - Module
730 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Servo pump engine power consumption VOLVO_SERVO_PMP_ENG_POWER
- Request
22 41 39 - Service 22
DID 4139 - Module
730 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2018. Supported for 2017, 2019 to 2020.
Slave A/T VOLVO_SLAVE_T
- Request
22 1E 1B - Service 22
DID 1E1B - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
SLC1 current VOLVO_SLC1_CURRENT
- Request
22 D9 0C - Service 22
DID D90C - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
SLC2 current VOLVO_SLC2_CURRENT
- Request
22 D9 0F - Service 22
DID D90F - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
SLC3 current VOLVO_SLC3_CURRENT
- Request
22 D9 10 - Service 22
DID D910 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Starter relay VOLVO_STARTER_RELAY
- Request
22 D9 50 - Service 22
DID D950 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Starter relay 1 VOLVO_STARTER_RELAY_1
- Request
22 DA 12 - Service 22
DID DA12 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Starter relay 2 VOLVO_STARTER_RELAY_2
- Request
22 EE EB - Service 22
DID EEEB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Steering angle, actual value VOLVO_STEER_ANG_ACT
- Request
22 33 02 - Service 22
DID 3302 - Module
760 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Steering shaft torque VOLVO_STEER_SHFT_TQ
- Request
22 33 0C - Service 22
DID 330C - Module
730 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10 − 12.7)- Range
- -12.7 to 12.8 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Supplementary heater counter VOLVO_SUPPLEMENTARY_HEATER
- Request
22 9A 0F - Service 22
DID 9A0F - Module
7E3 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
System relay VOLVO_SYSTEM_RELAY
- Request
22 D9 4F - Service 22
DID D94F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Tailgate closing motor VOLVO_TAILGATE_CLOSING
- Request
22 D9 08 - Service 22
DID D908 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Tailgate hall sensor signal VOLVO_TAILGATE_HALL_SENS
- Request
22 D9 04 - Service 22
DID D904 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Tailgate handle button VOLVO_TAILGATE_HANDLE
- Request
22 D9 00 - Service 22
DID D900 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Tailgate motor protection VOLVO_TAILGATE_MOTOR
- Request
22 EE 04 - Service 22
DID EE04 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Tailgate opening motor VOLVO_TAILGATE_OPENING
- Request
22 D9 07 - Service 22
DID D907 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Tailgate opening position VOLVO_TAILGATE_OPENING_POS
- Request
22 D9 09 - Service 22
DID D909 - Module
775 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Tailgate power supply VOLVO_TAILGATE_POWER_SUP
- Request
22 D1 11 - Service 22
DID D111 - Module
775 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Tailgate switch 1-2 VOLVO_TAILGATE_SWITCH_1_2
- Request
22 D9 01 - Service 22
DID D901 - Module
775 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Temperature left setting VOLVO_T_LEFT_SETTING_MS
- Request
22 D9 30 - Service 22
DID D930 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Temperature right setting VOLVO_T_RIGHT_SETTING_MS
- Request
22 D9 31 - Service 22
DID D931 - Module
733 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Throttle absolute position VOLVO_THROTTLE_ABS_POS
Pelican can show this parameter as the throttle position.
- Request
22 F4 11 - Service 22
DID F411 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Time since engine start VOLVO_TIME_SINCE_ENG_START
- Request
22 F4 1F - Service 22
DID F41F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Torque converter lock-up solenoid VOLVO_LOCK_UP_SOLENOID_SLU_7E1
- Request
22 DA 4C - Service 22
DID DA4C - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Torque converter lock-up solenoid current VOLVO_LOCK_UP_SOLENOID_SLU_CURRENT
- Request
22 1E 47 - Service 22
DID 1E47 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Torque converter lock-up solenoid current, requested VOLVO_LOCK_UP_SOLENOID_SLU
- Request
22 1E 41 - Service 22
DID 1E41 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Torque converter lock-up solenoid, requested VOLVO_LOCK_UP_SOLENOID_SLU_REQ
- Request
22 DA 4B - Service 22
DID DA4B - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Torque from engine VOLVO_TQ_ENG
- Request
22 E5 01 - Service 22
DID E501 - Module
DA18 → 18 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2016 to 2024.
Total engine running time at last service VOLVO_TOT_ENG_RUNNING_TIME
- Request
22 61 CC - Service 22
DID 61CC - Module
720 - Every
30 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Total months at last service VOLVO_TOT_MONTHS_LAST
- Request
22 61 CC - Service 22
DID 61CC - Module
720 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 6)- Range
- 0 to 393210
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Traction control switch indicator VOLVO_DTSC_SWITCH
- Request
22 2B 05 - Service 22
DID 2B05 - Module
760 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 64 − 1)- Range
- -1 to 2.98
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission fixed lock-up VOLVO_FIXED_LOCK_UP
- Request
22 1E 24 - Service 22
DID 1E24 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission kickdown VOLVO_KICKDOWN
- Request
22 DC E4 - Service 22
DID DCE4 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission line pressure solenoid current VOLVO_LINEAR_P_SOLENOID_SLT
- Request
22 1E 40 - Service 22
DID 1E40 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission line pressure solenoid current VOLVO_LINEAR_P_SOLENOID_SLT_CURRENT
- Request
22 DA 4A - Service 22
DID DA4A - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission line pressure solenoid current, requested VOLVO_LINEAR_P_SOLENOID
- Request
22 1E 1E - Service 22
DID 1E1E - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission line pressure solenoid current, requested VOLVO_LINEAR_P_SOLENOID_SLT_REQ
- Request
22 DA 49 - Service 22
DID DA49 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SL1 current VOLVO_LINEAR_P_SOLENOID_SL1
- Request
22 DA 4E - Service 22
DID DA4E - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SL1, requested, current VOLVO_LINEAR_P_SOLENOID_SL1_REQ
- Request
22 DA 4D - Service 22
DID DA4D - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SL2 current VOLVO_LINEAR_P_SOLENOID_SL2
- Request
22 DA 50 - Service 22
DID DA50 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SL2, requested, current VOLVO_LINEAR_P_SOLENOID_SL2_REQ
- Request
22 DA 4F - Service 22
DID DA4F - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SL3 current VOLVO_LINEAR_P_SOLENOID_SL3
- Request
22 DA 52 - Service 22
DID DA52 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SL3, requested, current VOLVO_LINEAR_P_SOLENOID_SL3_REQ
- Request
22 DA 51 - Service 22
DID DA51 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLB1, requested, current VOLVO_LINEAR_P_SOLENOID_SLB1_REQ
- Request
22 1E 45 - Service 22
DID 1E45 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLC1 current VOLVO_LINEAR_P_SOLENOID_SLC1
- Request
22 1E 48 - Service 22
DID 1E48 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLC1, requested, current VOLVO_LINEAR_P_SOLENOID_SLC1_REQ
- Request
22 1E 42 - Service 22
DID 1E42 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLC2 current VOLVO_LINEAR_P_SOLENOID_SLC2
- Request
22 1E 49 - Service 22
DID 1E49 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLC2, requested, current VOLVO_LINEAR_P_SOLENOID_SLC2_REQ
- Request
22 1E 43 - Service 22
DID 1E43 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLC3 current VOLVO_LINEAR_P_SOLENOID_SLC3
- Request
22 1E 4A - Service 22
DID 1E4A - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission linear pressure solenoid SLC3, requested, current VOLVO_LINEAR_P_SOLENOID_SLC3_REQ
- Request
22 1E 44 - Service 22
DID 1E44 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission lock-up function VOLVO_LOCK_UP_FUNCTION
- Request
22 DA 3C - Service 22
DID DA3C - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 3 − 0.333333)- Range
- -0.333 to 84.66
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission selector VOLVO_SELECTOR
- Request
22 DC EA - Service 22
DID DCEA - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission solenoid S1 status VOLVO_SOLENOID_S1_STAT
- Request
22 DD 89 - Service 22
DID DD89 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission solenoid S2 status VOLVO_SOLENOID_S2_STAT
- Request
22 DD 8A - Service 22
DID DD8A - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission start lock - start approved VOLVO_START_LOCK_START
- Request
22 DF 08 - Service 22
DID DF08 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 255)- Range
- 0 to 1
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission torque VOLVO_TQ
- Request
22 DD 8D - Service 22
DID DD8D - Module
7E1 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission torque limiting VOLVO_TQ_LIMITING
- Request
22 DC F0 - Service 22
DID DCF0 - Module
7E1 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 N·m
- Unit
- N·m
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Trip 1 VOLVO_TRIP_1
- Request
22 D9 36 - Service 22
DID D936 - Module
720 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 km
- Unit
- km
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Trip 2 VOLVO_TRIP_2
- Request
22 D9 37 - Service 22
DID D937 - Module
720 - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 km
- Unit
- km
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Turbo bypass valve opened VOLVO_TURBO_BYPASS_VLV
- Request
22 D9 EE - Service 22
DID D9EE - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Turbo control valve wastegate VOLVO_TURBO_CTRL_VLV_WASTEGATE
- Request
22 DC 10 - Service 22
DID DC10 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 8191)- Range
- 0 to 800 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Turbo control valve, bypass or variable nozzle VOLVO_TURBO_CTRL_VLV
- Request
22 DC 00 - Service 22
DID DC00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 8191)- Range
- 0 to 800 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Twilight sensor VOLVO_TWILIGHT_SENS
- Request
22 41 2A - Service 22
DID 412A - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Wastegate position VOLVO_WASTEGATE_POS
- Request
22 DC 80 - Service 22
DID DC80 - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Water cooled condenser outlet sensor temperature VOLVO_WATER_COOLED_T
- Request
22 EE 40 - Service 22
DID EE40 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2016 to 2024.
Water temperature VOLVO_WATER_T_MS_CAN
- Request
22 F4 05 - Service 22
DID F405 - Module
7E3 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Yaw rate sensor offset VOLVO_YAW_RATE_SENS_OFFSET
- Request
22 EE 03 - Service 22
DID EE03 - Module
760 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 3500)- Range
- 0 to 18.72
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Yaw rate signal VOLVO_YAW_RATE_SIG
- Request
22 2B 0B - Service 22
DID 2B0B - Module
760 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553 to 6553
- Unit
- Raw value
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.