Battery parameters
The Volvo S90 has 354 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery state of charge VOLVO_12V_BAT_ST_CHG
- Request
22 49 46 - Service 22
DID 4946 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1024 ÷ 15625)- Range
- 0 to 4294 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
12V system voltage, hd VOLVO_EQA_AUX_V_HD
Pelican can show this parameter as the starter battery voltage.
- Request
22 02 01 - Service 22
DID 0201 - Module
624 → 5A4 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 10000)- Range
- 0 to 100 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
All-wheel drive coupling module voltage VOLVO_MECU_V
- Request
22 DD 02 - Service 22
DID DD02 - Module
795 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Alternator charge voltage request VOLVO_ALTERNATOR_CHG_V_REQ
- Request
22 41 1D - Service 22
DID 411D - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Auxiliary battery current VOLVO_AUXILIARY_BAT
- Request
22 41 12 - Service 22
DID 4112 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 127)- Range
- -127 to 128 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Auxiliary battery temperature VOLVO_AUXILIARY_BAT_T
- Request
22 40 D3 - Service 22
DID 40D3 - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Auxiliary battery voltage VOLVO_AUXILIARY_BAT_V
- Request
22 41 7E - Service 22
DID 417E - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Auxiliary battery voltage VOLVO_EQA_AUX_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 20 05 - Service 22
DID 2005 - Module
7E5 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25.9 ÷ 255)- Range
- 0 to 25.9 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Average static low range battery current VOLVO_AVG_STATIC_LOW_RANGE
- Request
22 40 25 - Service 22
DID 4025 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 511)- Range
- -511 to 65024 mA
- Unit
- mA
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery age condition VOLVO_ED_BAT_AGE
- Request
22 63 08 - Service 22
DID 6308 - Module
7E5 → 7ED - Every
600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery charge balance, ah VOLVO_BAT_CHG_BALANCE_AH
- Request
22 41 A5 - Service 22
DID 41A5 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery charge, amps VOLVO_BAT_CHG_AMPS
- Request
22 40 90 - Service 22
DID 4090 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 511.7)- Range
- -511 to 3584 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery current VOLVO_BAT_CURRENT
- Request
22 40 90 - Service 22
DID 4090 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 512)- Range
- -512 to 3583 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery heater on VOLVO_ED_HEATER_ON
- Request
22 D3 02 - Service 22
DID D302 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery module 1 temperature VOLVO_ED_MOD_T1
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery module 2 temperature VOLVO_ED_MOD_T2
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery module 3 temperature VOLVO_ED_MOD_T3
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery module 4 temperature VOLVO_ED_MOD_T4
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery module 5 temperature VOLVO_ED_MOD_T5
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery module 6 temperature VOLVO_ED_MOD_T6
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery module 7 temperature VOLVO_ED_MOD_T7
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery module 8 temperature VOLVO_ED_MOD_T8
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery module 9 temperature VOLVO_ED_MOD_T9
- Request
22 02 02 - Service 22
DID 0202 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery operating mode VOLVO_EV_MODE
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 7
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery operation time since battery monitoring sensor reset, days VOLVO_BAT_OPERATION_TIME
- Request
22 40 27 - Service 22
DID 4027 - Module
726 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery relay VOLVO_BAT_RELAY
- Request
22 D9 53 - Service 22
DID D953 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery state of charge VOLVO_BAT_ST_CHG
- Request
22 40 28 - Service 22
DID 4028 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery state of charge VOLVO_BAT_ST_CHG_726
- Request
22 40 28 - Service 22
DID 4028 - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery temperature VOLVO_BAT_T
- Request
22 40 29 - Service 22
DID 4029 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery voltage VOLVO_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 CD - Service 22
DID 40CD - Module
D01A → 1F402E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40 + 5)- Range
- 0 to 1643 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery voltage VOLVO_BAT_V_726
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 2A - Service 22
DID 402A - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20 + 6)- Range
- 0 to 18.75 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Boost pressure after turbocharger VOLVO_BOOST_P_AFTER
- Request
22 03 3E - Service 22
DID 033E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 131 − 0.053435)- Range
- -0.0534 to 500 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Capacity loss VOLVO_CAP_LOSS
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell capacity, average VOLVO_ED_CAP_AS_AVG
- Request
22 03 10 - Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 18.2041 Ah
- Unit
- Ah
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell capacity, maximum VOLVO_ED_CAP_AS_MAX
- Request
22 03 10 - Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 18.2041 Ah
- Unit
- Ah
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell capacity, minimum VOLVO_ED_CAP_AS_MIN
- Request
22 03 10 - Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 18.2041 Ah
- Unit
- Ah
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell voltage reference, average VOLVO_ED_ADC_V_AVG
- Request
22 02 07 - Service 22
DID 0207 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell voltage reference, maximum VOLVO_ED_ADC_V_MAX
- Request
22 02 07 - Service 22
DID 0207 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val + 1500)- Range
- 1500 to 67035 mV
- Unit
- mV
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell voltage reference, minimum VOLVO_ED_ADC_V_MIN
- Request
22 02 07 - Service 22
DID 0207 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val + 1500)- Range
- 1500 to 67035 mV
- Unit
- mV
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charge air pressure VOLVO_CHG_AIR_P
- Request
22 EE 3E - Service 22
DID EE3E - Module
D016 → 1EC60E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.007812)- Range
- 0 to 511 kPa
- Unit
- kPa
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charge power limit VOLVO_CHG_POWER_LIM
- Request
22 48 9C - Service 22
DID 489C - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val × 4 ÷ 15625)- Range
- 0 to 4294 kW
- Unit
- kW
In testing for 2016 to 2024.
Charger 12V output voltage VOLVO_ED_OBL_LV
- Request
22 02 26 - Service 22
DID 0226 - Module
61A → 483 - Every
10 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger cable current VOLVO_CHARGER_CABLE
- Request
22 EE 8D - Service 22
DID EE8D - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 410)- Range
- -410 to 6143 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger cooling plate temperature VOLVO_ED_OBL_PLATE_T
- Request
22 02 23 - Service 22
DID 0223 - Module
61A → 483 - Every
60 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger current set point VOLVO_ED_OBL_A_SET
- Request
22 02 2A - Service 22
DID 022A - Module
61A → 483 - Every
60 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger HV output current VOLVO_ED_OBL_HV_A
- Request
22 02 25 - Service 22
DID 0225 - Module
61A → 483 - Every
10 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 204.7 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger HV output voltage VOLVO_ED_OBL_HV
- Request
22 02 26 - Service 22
DID 0226 - Module
61A → 483 - Every
10 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 819 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger mains current VOLVO_ED_OBL_MAINS_A
- Request
22 02 25 - Service 22
DID 0225 - Module
61A → 483 - Every
10 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 204.7 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger mains current, phase 1 VOLVO_OBL_A1
- Request
22 73 03 - Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 5990.4 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger mains current, phase 2 VOLVO_OBL_A2
- Request
22 73 03 - Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 5990.4 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger mains voltage VOLVO_ED_OBL_MAINS_V
- Request
22 02 26 - Service 22
DID 0226 - Module
61A → 483 - Every
10 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 819 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger mains voltage VOLVO_OBL_V
- Request
22 73 03 - Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 5990.4 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger power 1 VOLVO_OBL_P1
- Request
22 73 03 - Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 2000)- Range
- 0 to 29.952 kW
- Unit
- kW
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger power 2 VOLVO_OBL_P2
- Request
22 73 03 - Service 22
DID 7303 - Module
792 → 793 - Every
10 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 2000)- Range
- 0 to 29.952 kW
- Unit
- kW
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charger temperature VOLVO_ED_OBL_T
- Request
22 02 23 - Service 22
DID 0223 - Module
61A → 483 - Every
60 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charging cable current code VOLVO_ED_OBL_CABLE_A
- Request
22 02 25 - Service 22
DID 0225 - Module
61A → 483 - Every
10 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charging plug detected VOLVO_PLUG
Pelican can show this parameter as the plug state.
- Request
22 33 9D - Service 22
DID 339D - Module
7E4 → 7EC - Every
5 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charging socket lock VOLVO_CHG_SOCKET_LOCKED
- Request
22 EE 8C - Service 22
DID EE8C - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | UNLOCKED | Unlocked |
2 | LOCKED | Locked |
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Charging socket temperature VOLVO_ED_OBL_SOCKET_T
- Request
22 02 23 - Service 22
DID 0223 - Module
61A → 483 - Every
60 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Control module supply voltage VOLVO_ENG_CTRL_MODULE_SUP_V
- Request
22 F4 42 - Service 22
DID F442 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2016 to 2024.
Control module voltage VOLVO_CTRL_MODULE_V_MS_CAN
- Request
22 D9 04 - Service 22
DID D904 - Module
784 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2017. Supported for 2018 to 2020.
DC charger current VOLVO_DC_CHARGER_CURRENT
- Request
22 EE 16 - Service 22
DID EE16 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
DC charger voltage VOLVO_DC_CHARGER_V
- Request
22 EE 17 - Service 22
DID EE17 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
DC converter requested voltage VOLVO_EQA_CNVRTR_REQ_V
- Request
22 60 71 - Service 22
DID 6071 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 250 ÷ 10000)- Range
- 0 to 100 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Discharge power limit VOLVO_DCHG_POWER_LIM
- Request
22 48 9E - Service 22
DID 489E - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val × 4 ÷ 15625)- Range
- 0 to 4294 kW
- Unit
- kW
In testing for 2016 to 2024.
Estimated capacity VOLVO_CAP_EST
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 360)- Range
- 0 to 182.0416 Ah
- Unit
- Ah
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
External temperature sensor, HV battery cooling module VOLVO_EXTERNAL_T_SENS
- Request
22 EE 46 - Service 22
DID EE46 - Module
D016 → 1EC60E80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 2016 to 2024.
Front camera voltage supply VOLVO_FRONT_CAMERA_V_SUP
- Request
22 99 69 - Service 22
DID 9969 - Module
764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 ÷ 25)- Range
- 0 to 20.4 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Fuse DC charging voltage VOLVO_FUSE_DC_CHG_V
- Request
22 49 8B - Service 22
DID 498B - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2016 to 2024.
High voltage battery - voltage at IEM fuse VOLVO_HVBAT_V_IEM_FUSE
- Request
22 48 59 - Service 22
DID 4859 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2016 to 2024.
High voltage battery - voltage at IHFA fuse VOLVO_HVBAT_V_IHFA_FUSE
- Request
22 48 58 - Service 22
DID 4858 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2016 to 2024.
High voltage battery cell voltage sum VOLVO_HVBAT_CELL_VOLTAGES
- Request
22 49 7C - Service 22
DID 497C - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2016 to 2024.
High voltage battery contactor voltage VOLVO_HVBAT_CONTACTOR_V
- Request
22 48 57 - Service 22
DID 4857 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2016 to 2024.
High voltage battery coolant inlet temperature VOLVO_HVBAT_CLT_INLET_T
- Request
22 48 04 - Service 22
DID 4804 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery coolant outlet temperature VOLVO_HVBAT_CLT_OUTLET_T
- Request
22 49 90 - Service 22
DID 4990 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2016 to 2024.
High voltage battery current VOLVO_HVBAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Request
22 48 02 - Service 22
DID 4802 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery negative contactor voltage VOLVO_HVBAT_NEGATIVE_V
- Request
22 4A 58 - Service 22
DID 4A58 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 V
- Unit
- V
In testing for 2016 to 2024.
High voltage battery state of charge VOLVO_HVBAT_ST_CHG
Pelican can show this parameter as the state of charge.
- Request
22 48 01 - Service 22
DID 4801 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 131 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery state of health VOLVO_HVBAT_ST_HEALTH
Pelican can show this parameter as the state of health.
- Request
22 49 6D - Service 22
DID 496D - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 100)- Range
- 0 to 42949672 %
- Unit
- %
In testing for 2016 to 2024.
High voltage battery voltage VOLVO_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 48 03 - Service 22
DID 4803 - Module
D016 → 1EC6AE80 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, average temperature VOLVO_HVBAT_AVG_T
- Request
22 49 1B - Service 22
DID 491B - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 50)- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, coolant pump speed, actual VOLVO_HVBAT_CLT_PMP_SPD_ACT
- Request
22 48 67 - Service 22
DID 4867 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, coolant pump speed, requested VOLVO_HVBAT_CLT_PMP_SPD
- Request
22 48 66 - Service 22
DID 4866 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, high-voltage coolant heater fuse voltage VOLVO_HVBAT_HVCH_FUSE_V
- Request
22 48 0A - Service 22
DID 480A - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, IEM fuse voltage VOLVO_HVBAT_IEM_FUSE_V
- Request
22 48 08 - Service 22
DID 4808 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, IGM fuse voltage VOLVO_HVBAT_IGM_FUSE_V
- Request
22 48 09 - Service 22
DID 4809 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, inlet coolant temperature VOLVO_HVBAT_INLET_ECT
- Request
22 48 04 - Service 22
DID 4804 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, max temperature VOLVO_HVBAT_MAX_T
- Request
22 49 45 - Service 22
DID 4945 - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 100 − 50)- Range
- -50 to 605 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage battery, OBC fuse voltage VOLVO_HVBAT_OBC_FUSE_V
- Request
22 48 0B - Service 22
DID 480B - Module
D016 → 1EC6AE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
High voltage system voltage VOLVO_HIGH_V_SYSTEM_V
- Request
22 98 5C - Service 22
DID 985C - Module
D016 → 1EC6EE80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 V
- Unit
- V
In testing for 2016 to 2024.
High voltage system voltage VOLVO_HIGH_V_SYSTEM_V_D016
- Request
22 98 5C - Service 22
DID 985C - Module
D016 → 1ED24E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 V
- Unit
- V
In testing for 2016 to 2024.
Highest cell voltage VOLVO_CELL_V_MAX
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery amperage VOLVO_EQA_HV_A
- Request
22 60 53 - Service 22
DID 6053 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- 0 to 100 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery available energy VOLVO_HV_E
- Request
22 32 0C - Service 22
DID 320C - Module
7E4 → 7EC - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327.675 kWh
- Unit
- kWh
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery coolant temperature VOLVO_EQA_HV_COOLANT_T
- Request
22 25 26 - Service 22
DID 2526 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 1250 ÷ 10000)- Range
- 0 to 100 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery current VOLVO_ED_HV_A
- Request
22 02 03 - Service 22
DID 0203 - Module
7E7 → 7EF - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.9687 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery current VOLVO_HV_A
Pelican can show this parameter as the traction battery current.
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
(val × -1 ÷ 32)- Range
- -1023.9687 to 1024 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery open-circuit voltage VOLVO_OCV
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery state of charge VOLVO_EQA_HV_SOC
Pelican can show this parameter as the state of charge.
- Request
22 60 50 - Service 22
DID 6050 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery temperature VOLVO_ED_HV_T
- Request
22 02 01 - Service 22
DID 0201 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery temperature, average VOLVO_HV_T_AVG
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery temperature, maximum VOLVO_HV_T_MAX
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery temperature, minimum VOLVO_HV_T_MIN
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery voltage VOLVO_ED_HV_V
- Request
22 02 04 - Service 22
DID 0204 - Module
7E7 → 7EF - Every
10 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery voltage VOLVO_EQA_HV_V
- Request
22 60 75 - Service 22
DID 6075 - Module
7E5 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 25 ÷ 1000)- Range
- 0 to 100 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV battery voltage VOLVO_HV_V
Pelican can show this parameter as the traction battery voltage.
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV contactor cycles remaining VOLVO_ED_CONT_LEFT
- Request
22 03 0B - Service 22
DID 030B - Module
7E7 → 7EF - Every
600 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV contactor cycles remaining VOLVO_HV_CONT_LEFT
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV contactor cycles, maximum VOLVO_ED_CONT_MAX
- Request
22 03 0C - Service 22
DID 030C - Module
7E7 → 7EF - Every
600 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV contactor cycles, maximum VOLVO_HV_CONT_MAX
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV contactor state VOLVO_ED_CONTACTOR
- Request
22 D0 00 - Service 22
DID D000 - Module
7E7 → 7EF - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV contactor state VOLVO_HV_CONTACTOR
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 3
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV DC fault code VOLVO_ED_DC_FAULT
- Request
22 02 09 - Service 22
DID 0209 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV isolation resistance VOLVO_ED_ISO
- Request
22 02 09 - Service 22
DID 0209 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65534 kΩ
- Unit
- kΩ
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV link voltage VOLVO_HV_LINK_V
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
HV plug interlock closed VOLVO_HV_INTERLOCK_PLUG
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Initial capacity VOLVO_CAP_INIT
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 360)- Range
- 0 to 182.0416 Ah
- Unit
- Ah
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Leakage current, 10 kilohertz VOLVO_LEAK_HF10
- Request
22 50 66 - Service 22
DID 5066 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 32.768)- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Leakage DC current VOLVO_LEAK_DC
- Request
22 50 65 - Service 22
DID 5065 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 32.768)- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Leakage diagnostic code VOLVO_LEAK_DIAG
- Request
22 50 64 - Service 22
DID 5064 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Leakage high-frequency current VOLVO_LEAK_HF
- Request
22 50 67 - Service 22
DID 5067 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 32.768)- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Leakage low-frequency current VOLVO_LEAK_LF
- Request
22 50 68 - Service 22
DID 5068 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 32.768)- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Lowest cell voltage VOLVO_CELL_V_MIN
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Main charger current VOLVO_MAIN_CHARGER_CURRENT
- Request
22 EE 15 - Service 22
DID EE15 - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Main charger voltage VOLVO_MAIN_CHARGER_V
- Request
22 EE 1C - Service 22
DID EE1C - Module
D016 → 1EC68E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Mains active power VOLVO_MAINS_P
- Request
22 50 4A - Service 22
DID 504A - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 20)- Range
- -20 to 45.5349 kW
- Unit
- kW
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Mains current limit VOLVO_MAINS_A_LIMIT
- Request
22 50 70 - Service 22
DID 5070 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 32.768)- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Mains current, phase 2 VOLVO_MAINS_A_2
- Request
22 50 3A - Service 22
DID 503A - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 200)- Range
- -200 to 3895.9375 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Mains current, phase 3 VOLVO_MAINS_A_3
- Request
22 50 3B - Service 22
DID 503B - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 200)- Range
- -200 to 3895.9375 A
- Unit
- A
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Mains frequency VOLVO_MAINS_HZ
- Request
22 50 49 - Service 22
DID 5049 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128 + 10)- Range
- 10 to 521.9921 Hz
- Unit
- Hz
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Mains ground resistance VOLVO_MAINS_GND_R
- Request
22 50 62 - Service 22
DID 5062 - Module
792 → 793 - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000 − 32.768)- Range
- -32.768 to 32.7669
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Mains voltage, phases 1-2 VOLVO_MAINS_V_12
- Request
22 50 3F - Service 22
DID 503F - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Mains voltage, phases 2-3 VOLVO_MAINS_V_23
- Request
22 50 41 - Service 22
DID 5041 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Mains voltage, phases 3-1 VOLVO_MAINS_V_31
- Request
22 50 42 - Service 22
DID 5042 - Module
792 → 793 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Module voltage VOLVO_MODULE_V
- Request
22 D1 11 - Service 22
DID D111 - Module
D016 → 1EC70E80 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Open-circuit voltage state VOLVO_OCV_STATE
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
val- Range
- 0 to 4
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Real state of charge, maximum VOLVO_SOC_REAL_MAX
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Real state of charge, minimum VOLVO_SOC_REAL_MIN
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Secondary battery charge time VOLVO_SECONDARY_BAT_CHG
- Request
22 EE D3 - Service 22
DID EED3 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Secondary battery needed charge time VOLVO_SECONDARY_BAT_NEEDED
- Request
22 EE D5 - Service 22
DID EED5 - Module
726 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Secondary battery relay VOLVO_SECONDARY_BAT_RELAY
- Request
22 41 9C - Service 22
DID 419C - Module
726 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Secondary battery temperature VOLVO_SECONDARY_BAT_T_25_C
- Request
22 EE D2 - Service 22
DID EED2 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Secondary battery voltage VOLVO_SECONDARY_BAT_V
- Request
22 41 7E - Service 22
DID 417E - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Secondary battery voltage average value VOLVO_SECONDARY_BAT_V_AVG
- Request
22 EE D7 - Service 22
DID EED7 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Secondary battery voltage latest stored VOLVO_SECONDARY_BAT_V_LATEST
- Request
22 EE D4 - Service 22
DID EED4 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Service interlock closed VOLVO_HV_INTERLOCK_SVC
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Servo supply voltage VOLVO_SERVO_SUP_V
- Request
22 41 3D - Service 22
DID 413D - Module
730 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Start/stop battery relay VOLVO_START_STOP_BAT_RELAY
- Request
22 EF 51 - Service 22
DID EF51 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Start/stop secondary battery relay VOLVO_START_STOP_SECONDARY
- Request
22 EF 52 - Service 22
DID EF52 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
State of charge VOLVO_SOC
- Request
22 40 28 - Service 22
DID 4028 - Module
D01A → 1F402E80 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
State of charge VOLVO_SOC_V2
Pelican can show this parameter as the state of charge.
- Request
21 08 - Service 21
PID 08 - Module
79B → 7BB - Every
10 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
State of charge recalibration state VOLVO_SOC_RECAL
- Request
21 25 - Service 21
PID 25 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 3
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
State of charge, displayed VOLVO_SOC_DISPLAY
- Request
21 25 - Service 21
PID 25 - Module
79B → 7BB - Every
60 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
State of health VOLVO_SOH
Pelican can show this parameter as the state of health.
- Request
21 61 - Service 21
PID 61 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 %
- Unit
- %
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
State of health, raw VOLVO_ED_SOH
- Request
22 03 10 - Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Sum of cell voltages VOLVO_HV_CELL_SUM_V
- Request
21 07 - Service 21
PID 07 - Module
79B → 7BB - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Supercharger clutch, requested position VOLVO_SUPERCHARGER_CLU_REQ
- Request
22 EE 84 - Service 22
DID EE84 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Time with HV off VOLVO_ED_HV_OFF_TIME
- Request
22 03 10 - Service 22
DID 0310 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 8 to 31 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 s
- Unit
- s
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Transmission control module supply voltage VOLVO_MECU_SUP_V
- Request
22 DD 02 - Service 22
DID DD02 - Module
7E1 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Usable capacity, full VOLVO_CAP_FULL
- Request
21 61 - Service 21
PID 61 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 360)- Range
- -91.0222 to 91.0194 Ah
- Unit
- Ah
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Voltage supply VOLVO_V_SUP
- Request
22 D9 01 - Service 22
DID D901 - Module
737 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 ÷ 25)- Range
- 0 to 20.4 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Voltage supply VOLVO_V_SUP_764
- Request
22 D1 12 - Service 22
DID D112 - Module
764 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 ÷ 25)- Range
- 0 to 20.4 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Voltage supply VOLVO_V_SUP_MS_CAN
- Request
22 D1 11 - Service 22
DID D111 - Module
791 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Voltage/power sensitive loads connected VOLVO_V_POWER_SENSITIVE
- Request
22 EE A2 - Service 22
DID EEA2 - Module
726 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Battery › Cells
Cell 1 voltage VOLVO_CELL_V1
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 1 voltage VOLVO_ED_CELL_V1
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 2 voltage VOLVO_CELL_V2
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 2 voltage VOLVO_ED_CELL_V2
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 3 voltage VOLVO_CELL_V3
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 3 voltage VOLVO_ED_CELL_V3
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 4 voltage VOLVO_CELL_V4
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 4 voltage VOLVO_ED_CELL_V4
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 5 voltage VOLVO_CELL_V5
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 5 voltage VOLVO_ED_CELL_V5
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 6 voltage VOLVO_CELL_V6
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 6 voltage VOLVO_ED_CELL_V6
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 7 voltage VOLVO_CELL_V7
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 7 voltage VOLVO_ED_CELL_V7
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 8 voltage VOLVO_CELL_V8
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 8 voltage VOLVO_ED_CELL_V8
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 9 voltage VOLVO_CELL_V9
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 9 voltage VOLVO_ED_CELL_V9
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 10 voltage VOLVO_CELL_V10
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 10 voltage VOLVO_ED_CELL_V10
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 11 voltage VOLVO_CELL_V11
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 11 voltage VOLVO_ED_CELL_V11
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 12 voltage VOLVO_CELL_V12
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 12 voltage VOLVO_ED_CELL_V12
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 13 voltage VOLVO_CELL_V13
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 13 voltage VOLVO_ED_CELL_V13
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 14 voltage VOLVO_CELL_V14
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 14 voltage VOLVO_ED_CELL_V14
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 15 voltage VOLVO_CELL_V15
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 15 voltage VOLVO_ED_CELL_V15
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 16 voltage VOLVO_CELL_V16
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 16 voltage VOLVO_ED_CELL_V16
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 17 voltage VOLVO_CELL_V17
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 17 voltage VOLVO_ED_CELL_V17
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 18 voltage VOLVO_CELL_V18
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 18 voltage VOLVO_ED_CELL_V18
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 19 voltage VOLVO_CELL_V19
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 19 voltage VOLVO_ED_CELL_V19
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 20 voltage VOLVO_CELL_V20
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 20 voltage VOLVO_ED_CELL_V20
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 21 voltage VOLVO_CELL_V21
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 21 voltage VOLVO_ED_CELL_V21
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 22 voltage VOLVO_CELL_V22
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 22 voltage VOLVO_ED_CELL_V22
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 23 voltage VOLVO_CELL_V23
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 23 voltage VOLVO_ED_CELL_V23
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 24 voltage VOLVO_CELL_V24
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 24 voltage VOLVO_ED_CELL_V24
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 25 voltage VOLVO_CELL_V25
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 25 voltage VOLVO_ED_CELL_V25
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 26 voltage VOLVO_CELL_V26
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 26 voltage VOLVO_ED_CELL_V26
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 27 voltage VOLVO_CELL_V27
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 27 voltage VOLVO_ED_CELL_V27
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 28 voltage VOLVO_CELL_V28
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 28 voltage VOLVO_ED_CELL_V28
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 29 voltage VOLVO_CELL_V29
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 29 voltage VOLVO_ED_CELL_V29
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 30 voltage VOLVO_CELL_V30
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 30 voltage VOLVO_ED_CELL_V30
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 31 voltage VOLVO_CELL_V31
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 31 voltage VOLVO_ED_CELL_V31
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 32 voltage VOLVO_CELL_V32
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 32 voltage VOLVO_ED_CELL_V32
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 33 voltage VOLVO_CELL_V33
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 33 voltage VOLVO_ED_CELL_V33
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 34 voltage VOLVO_CELL_V34
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 34 voltage VOLVO_ED_CELL_V34
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 35 voltage VOLVO_CELL_V35
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 35 voltage VOLVO_ED_CELL_V35
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 36 voltage VOLVO_CELL_V36
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 36 voltage VOLVO_ED_CELL_V36
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 37 voltage VOLVO_CELL_V37
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 37 voltage VOLVO_ED_CELL_V37
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 38 voltage VOLVO_CELL_V38
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 38 voltage VOLVO_ED_CELL_V38
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 39 voltage VOLVO_CELL_V39
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 39 voltage VOLVO_ED_CELL_V39
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 40 voltage VOLVO_CELL_V40
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 40 voltage VOLVO_ED_CELL_V40
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 41 voltage VOLVO_CELL_V41
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 41 voltage VOLVO_ED_CELL_V41
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 42 voltage VOLVO_CELL_V42
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 42 voltage VOLVO_ED_CELL_V42
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 43 voltage VOLVO_CELL_V43
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 43 voltage VOLVO_ED_CELL_V43
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 44 voltage VOLVO_CELL_V44
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 44 voltage VOLVO_ED_CELL_V44
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 45 voltage VOLVO_CELL_V45
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 45 voltage VOLVO_ED_CELL_V45
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 46 voltage VOLVO_CELL_V46
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 46 voltage VOLVO_ED_CELL_V46
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 47 voltage VOLVO_CELL_V47
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 47 voltage VOLVO_ED_CELL_V47
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 48 voltage VOLVO_CELL_V48
- Request
21 41 - Service 21
PID 41 - Module
79B → 7BB - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 48 voltage VOLVO_ED_CELL_V48
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 49 voltage VOLVO_CELL_V49
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 49 voltage VOLVO_ED_CELL_V49
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 50 voltage VOLVO_CELL_V50
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 50 voltage VOLVO_ED_CELL_V50
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 51 voltage VOLVO_CELL_V51
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 51 voltage VOLVO_ED_CELL_V51
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 52 voltage VOLVO_CELL_V52
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 52 voltage VOLVO_ED_CELL_V52
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 53 voltage VOLVO_CELL_V53
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 53 voltage VOLVO_ED_CELL_V53
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 54 voltage VOLVO_CELL_V54
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 54 voltage VOLVO_ED_CELL_V54
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 55 voltage VOLVO_CELL_V55
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 55 voltage VOLVO_ED_CELL_V55
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 56 voltage VOLVO_CELL_V56
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 56 voltage VOLVO_ED_CELL_V56
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 57 voltage VOLVO_CELL_V57
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 57 voltage VOLVO_ED_CELL_V57
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 58 voltage VOLVO_CELL_V58
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 58 voltage VOLVO_ED_CELL_V58
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 59 voltage VOLVO_CELL_V59
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 59 voltage VOLVO_ED_CELL_V59
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 60 voltage VOLVO_CELL_V60
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 60 voltage VOLVO_ED_CELL_V60
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 61 voltage VOLVO_CELL_V61
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 61 voltage VOLVO_ED_CELL_V61
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 62 voltage VOLVO_CELL_V62
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 62 voltage VOLVO_ED_CELL_V62
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 63 voltage VOLVO_CELL_V63
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 63 voltage VOLVO_ED_CELL_V63
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 64 voltage VOLVO_CELL_V64
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 64 voltage VOLVO_ED_CELL_V64
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 65 voltage VOLVO_CELL_V65
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 65 voltage VOLVO_ED_CELL_V65
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 66 voltage VOLVO_CELL_V66
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 66 voltage VOLVO_ED_CELL_V66
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 67 voltage VOLVO_CELL_V67
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 67 voltage VOLVO_ED_CELL_V67
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 68 voltage VOLVO_CELL_V68
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 68 voltage VOLVO_ED_CELL_V68
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 69 voltage VOLVO_CELL_V69
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 69 voltage VOLVO_ED_CELL_V69
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 70 voltage VOLVO_CELL_V70
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 70 voltage VOLVO_ED_CELL_V70
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 71 voltage VOLVO_CELL_V71
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 71 voltage VOLVO_ED_CELL_V71
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 72 voltage VOLVO_CELL_V72
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 72 voltage VOLVO_ED_CELL_V72
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 73 voltage VOLVO_CELL_V73
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 73 voltage VOLVO_ED_CELL_V73
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 74 voltage VOLVO_CELL_V74
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 74 voltage VOLVO_ED_CELL_V74
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 75 voltage VOLVO_CELL_V75
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 75 voltage VOLVO_ED_CELL_V75
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 76 voltage VOLVO_CELL_V76
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 76 voltage VOLVO_ED_CELL_V76
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 77 voltage VOLVO_CELL_V77
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 77 voltage VOLVO_ED_CELL_V77
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 78 voltage VOLVO_CELL_V78
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 78 voltage VOLVO_ED_CELL_V78
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 79 voltage VOLVO_CELL_V79
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 79 voltage VOLVO_ED_CELL_V79
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 80 voltage VOLVO_CELL_V80
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 80 voltage VOLVO_ED_CELL_V80
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 81 voltage VOLVO_CELL_V81
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 81 voltage VOLVO_ED_CELL_V81
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 82 voltage VOLVO_CELL_V82
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 82 voltage VOLVO_ED_CELL_V82
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 83 voltage VOLVO_CELL_V83
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 83 voltage VOLVO_ED_CELL_V83
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 84 voltage VOLVO_CELL_V84
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 84 voltage VOLVO_ED_CELL_V84
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 85 voltage VOLVO_CELL_V85
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 85 voltage VOLVO_ED_CELL_V85
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 86 voltage VOLVO_CELL_V86
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 86 voltage VOLVO_ED_CELL_V86
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 87 voltage VOLVO_CELL_V87
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 87 voltage VOLVO_ED_CELL_V87
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 88 voltage VOLVO_CELL_V88
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 88 voltage VOLVO_ED_CELL_V88
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 89 voltage VOLVO_CELL_V89
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 89 voltage VOLVO_ED_CELL_V89
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 90 voltage VOLVO_CELL_V90
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 90 voltage VOLVO_ED_CELL_V90
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 91 voltage VOLVO_CELL_V91
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 91 voltage VOLVO_ED_CELL_V91
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 92 voltage VOLVO_CELL_V92
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 92 voltage VOLVO_ED_CELL_V92
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 93 voltage VOLVO_CELL_V93
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 93 voltage VOLVO_ED_CELL_V93
- Request
22 02 08 - Service 22
DID 0208 - Module
7E7 → 7EF - Every
60 s - Testing
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 94 voltage VOLVO_CELL_V94
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 95 voltage VOLVO_CELL_V95
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.
Cell 96 voltage VOLVO_CELL_V96
- Request
21 42 - Service 21
PID 42 - Module
79B → 7BB - Every
60 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.999 V
- Unit
- V
In testing for 2016 to 2017, 2019 to 2024. Not supported for 2018.