Engine parameters
The Toyota Hilux has 278 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/F heater duty bank 1 sensor 1 HILUX_F_HEATER_DUTY_B1S1
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 25 ÷ 4096)- Range
- 0 to 399.9 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
A/F ratio learn value high, bank 1 HILUX_AFRL_HIGH_1
- Request
22 10 A2 - Service 22
DID 10A2 - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 99.6 ÷ 255 − 50)- Range
- 0 to 49 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
A/F ratio learn value idle, bank 1 HILUX_AFRL_IDLE_1
- Request
22 10 A2 - Service 22
DID 10A2 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 99.6 ÷ 255 − 50)- Range
- 0 to 49 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
A/F ratio learn value low, bank 1 HILUX_AFRL_LOW_1
- Request
22 10 A2 - Service 22
DID 10A2 - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 99.6 ÷ 255 − 50)- Range
- 0 to 49 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
A/F ratio learn value mid.1, bank 1 HILUX_AFRL_MID_1_1
- Request
22 10 A2 - Service 22
DID 10A2 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 99.6 ÷ 255 − 50)- Range
- 0 to 49 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
A/F ratio learn value mid.2, bank 1 HILUX_AFRL_MID_2_1
- Request
22 10 A2 - Service 22
DID 10A2 - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 99.6 ÷ 255 − 50)- Range
- 0 to 49 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
A/F ratio learned high, bank 1 HILUX_A_F_RATIO_LEARNED_HIGH_BANK_1
- Request
22 10 2A - Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
A/F ratio learned idle, bank 1 HILUX_A_F_RATIO_LEARNED_IDLE_BANK_1
- Request
22 10 2A - Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
A/F ratio learned low, bank 1 HILUX_A_F_RATIO_LEARNED_LOW_BANK_1
- Request
22 10 2A - Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
A/F ratio learned mid 1, bank 1 HILUX_A_F_RATIO_LEARNED_MID_1_BANK_1
- Request
22 10 2A - Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
A/F ratio learned mid 2, bank 1 HILUX_A_F_RATIO_LEARNED_MID_2_BANK_1
- Request
22 10 2A - Service 22
DID 102A - Module
700 → 708 - Every
3600 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255 − 50)- Range
- -50 to 50 %
- Unit
- %
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
A/F test results 1, incomplete HILUX_F_TEST_RESULTS_1
- Request
21 E3 - Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Accelerator sensor volt %, 1 HILUX_ACCEL_SENS_NO_1_VOLT
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Accelerator sensor volt %, 2 HILUX_ACCEL_SENS_NO_2_VOLT
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Accessory relay on HILUX_ACC_RELAY_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 46 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Accumulator open HILUX_ACCUMULATOR_OPEN
- Request
21 BE - Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Acoustic control induction system vacuum switching valve on HILUX_ACIS_VSV_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Actual EGR A duty cycle/position EGR_A_ACTSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Actual EGR B duty cycle/position EGR_B_ACTSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Actual engine torque HILUX_ACT_ENG_TQ
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val − 32768)- Range
- -32768 to 32767 N·m
- Unit
- N·m
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Actuator power supply on HILUX_ACTUATOR_POWER_SUP_ON
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 146 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
AF lambda B1S1 HILUX_AF_LAMBDA_B1S1
- Request
21 04 - Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 1.99 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
AFS current B1S1 HILUX_AFS_CURRENT_B1S1
- Request
21 04 - Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 127.99 mA
- Unit
- mA
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Air conditioning compressor HILUX_AC_COMP
- Request
21 E6 - Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.
Air mix servo target pulse, driver HILUX_AIR_MIX_SERVO_TARG_DConfirmed
- Request
21 41 - Service 21
PID 41 - Module
7C4 → 7CC - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 0 to 7 of the reply, 8 bits.
0x7F = 127 → 127
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Air mix servo, actual pulse, d HILUX_AIR_MIX_SERVO_ACT_DConfirmed
- Request
21 41 - Service 21
PID 41 - Module
7C4 → 7CC - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 8 to 15 of the reply, 8 bits.
0x7F = 127 → 127
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Alt voltage - active test HILUX_ALT_VOL_ACTIVE_TEST
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Alt voltage - non active test HILUX_ALT_VOL_NON_ACTIVE
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Alternator output duty HILUX_ALTERNATOR_OUTPUT
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 25 ÷ 4096)- Range
- 0 to 399.9 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Alternator output duty cycle HILUX_ALT_DUTY_CYCLEConfirmed
- Request
22 15 FA - Service 22
DID 15FA - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 0 to 15 of the reply, 16 bits.
0x0A80 = 2688 → (2688 ÷ 164) = 16.390244 %
- Formula
(val ÷ 164)- Range
- 0 to 399 %
- Unit
- %
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Ambient temperature HILUX_AMBIENT_T
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Atmosphere pressure HILUX_ATMOSPHERE_PRESSURE
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2018. Supported for 2013, 2021 to 2022, 2024 to 2025.
Boost pressure sensor A BP_A_ACTSAE J1979Confirmed
Actual turbocharger/supercharger A boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Boost pressure sensor B BP_B_ACTSAE J1979Confirmed
Actual turbocharger/supercharger B boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018, 2022. Supported for 2013, 2021, 2024 to 2025.
Calculated load_7e0 HILUX_CALCULATED_LOAD_7E0
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Catalyst temperature B1S1 HILUX_CATALYST_T_B1S1
- Request
21 05 - Service 21
PID 05 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Catalyst temperature B1S2 HILUX_CATALYST_T_B1S2
- Request
21 05 - Service 21
PID 05 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Catalyst temperature bank 2 sensor 1 HILUX_CAT_T_BANK_2_SENS_1
- Request
22 1F 3D - Service 22
DID 1F3D - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 40)- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Catalyst temperature bank 2 sensor 2 HILUX_CAT_T_BANK_2_SENS_2
- Request
22 1F 3F - Service 22
DID 1F3F - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 40)- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Catalyst temperature, bank 1 sensor 2, variant 2 HILUX_CAT_T_B1S2_V2
- Request
21 3E - Service 21
PID 3E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Check mode on HILUX_CHECK_MODE_ON
- Request
21 E3 - Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Closed throttle position switch on HILUX_CLOSED_THROTTLE_POS_ON
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 125 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Codes, include history HILUX_CODES_INCLUDE
- Request
21 E1 - Service 21
PID E1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Commanded boost pressure A BP_A_CMDSAE J1979Confirmed
Turbocharger/supercharger A commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Commanded boost pressure B BP_B_CMDSAE J1979Confirmed
Turbocharger/supercharger B commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Commanded EGR A duty cycle/position EGR_A_CMDSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Commanded EGR B duty cycle/position EGR_B_CMDSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Continuously variable transmission learning complete HILUX_CVT_LEARNED
- Request
21 DD - Service 21
PID DD - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Continuously variable transmission oil pressure HILUX_CVT_OIL_P
- Request
21 BE - Service 21
PID BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 40)- Range
- 0 to 10200 kPa
- Unit
- kPa
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Coolant temp HILUX_COOLANT_TEMP
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 215 °C
- Unit
- °C
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Coolant temperature HILUX_COOLANT_TConfirmed
- Request
21 23 - Service 21
PID 23 - Module
7C0 → 7C8 - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Toyota Hilux.
Bits 0 to 7 of the reply, 8 bits.
0x6E = 110 → (110 × 0.5) = 55 °C
- Formula
(val × 0.5)- Range
- 0 to 127.5 °C
- Unit
- °C
Confirmed for 2022, 2024. In testing for 1988 to 2021, 2023, 2025 to 2026.
Coolant water route switching valve 1, closed? HILUX_COOLANT_VALVE_1_CLOSE
- Request
22 28 2C - Service 22
DID 282C - Module
700 → 708 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Coolant water route switching valve 2, closed? HILUX_COOLANT_VALVE_2_CLOSE
- Request
22 28 47 - Service 22
DID 2847 - Module
700 → 708 - Every
1 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Cooling fan duty ratio HILUX_COOLING_FAN_DUTY_RATIO
- Request
22 10 46 - Service 22
DID 1046 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 127.5 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Cruise control on HILUX_CRUISE_CTRL_ON
- Request
21 D3 - Service 21
PID D3 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Cylinder 1 injection volume HILUX_CYL_1_INJ_VOLUMEConfirmed
- Request
22 11 31 - Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -640 to 15
- Unit
- Raw value
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Cylinder 2 injection volume HILUX_CYL_2_INJ_VOLUMEConfirmed
- Request
22 11 31 - Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 16 to 31 of the reply, 16 bits.
0x8017 = 32791 → (32791 × 19531 ÷ 1000000 − 640) = 0.441021
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -640 to 15
- Unit
- Raw value
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Cylinder 3 injection volume HILUX_CYL_3_INJ_VOLUMEConfirmed
- Request
22 11 31 - Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 32 to 47 of the reply, 16 bits.
0x8015 = 32789 → (32789 × 19531 ÷ 1000000 − 640) = 0.401959
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -640 to 15
- Unit
- Raw value
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Cylinder 4 injection volume HILUX_CYL_4_INJ_VOLUMEConfirmed
- Request
22 11 31 - Service 22
DID 1131 - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -640 to 15
- Unit
- Raw value
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Cylinder number HILUX_CYLINDER_NUMBER
- Request
21 C1 - Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Destination HILUX_DESTINATION
- Request
21 C1 - Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Diesel particulate and nitrogen oxide reduction regeneration status HILUX_DPF_REGEN_STATConfirmed
- Request
22 11 9B - Service 22
DID 119B - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Diesel particulate filter accumulation level HILUX_DPF_ACCUMULATION
- Request
21 38 - Service 21
PID 38 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Diesel particulate filter differential pressure HILUX_DPF_DIFF_PConfirmed
- Request
22 1F 7A - Service 22
DID 1F7A - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 8 to 23 of the reply, 16 bits. The value is signed.
0x005C = 92 → (92 ÷ 100) = 0.92 kPa
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 kPa
- Unit
- kPa
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Dist battery cable disconnect HILUX_DIST_BATT_CABLE
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
EGR A error EGR_A_ERRSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
EGR B error EGR_B_ERRSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Electric fan motor on HILUX_ELEC_FAN_MOTOR_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 34 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Electric thermostat duty ratio HILUX_ELECTRIC_THERMOSTAT_DUTY_RATIO
- Request
22 28 29 - Service 22
DID 2829 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Electric water pump HILUX_ELECTRIC_WATER_PUMP
- Request
22 28 27 - Service 22
DID 2827 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 40)- Range
- 0 to 10200 rpm
- Unit
- rpm
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Electric water pump RPM HILUX_EWP_RPM
- Request
22 10 43 - Service 22
DID 1043 - Module
700 → 708 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Electric water pump target speed HILUX_EWP_TARGET_VSS
- Request
22 10 43 - Service 22
DID 1043 - Module
700 → 708 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Engine coolant temp HILUX_ECTConfirmed
- Request
21 26 - Service 21
PID 26 - Module
7C4 → 7CC - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Toyota Hilux.
Bits 0 to 7 of the reply, 8 bits.
0x9A = 154 → (154 × 89.25 ÷ 255 + 1.3) = 55.2 °C
- Formula
(val × 89.25 ÷ 255 + 1.3)- Range
- 1.3 to 90.55 °C
- Unit
- °C
Confirmed for 2022, 2024. In testing for 1988 to 2021, 2023, 2025 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022. Supported for 2013, 2018, 2021, 2024 to 2025.
Engine coolant temperature, ignition on HILUX_ECT_IGNConfirmed
- Request
22 10 41 - Service 22
DID 1041 - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Toyota Hilux.
Bits 0 to 7 of the reply, 8 bits.
0x9D = 157 → (157 × 62.5 ÷ 100 − 40) = 58.125 °C
- Formula
(val × 62.5 ÷ 100 − 40)- Range
- -40 to 119.375 °C
- Unit
- °C
Confirmed for 2022, 2024. In testing for 1988 to 2021, 2023, 2025 to 2026.
Engine coolant temperature, initial HILUX_ECT_INITConfirmed
- Request
22 10 41 - Service 22
DID 1041 - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Toyota Hilux.
Bits 8 to 15 of the reply, 8 bits.
0x99 = 153 → (153 × 62.5 ÷ 100 − 40) = 55.625 °C
- Formula
(val × 62.5 ÷ 100 − 40)- Range
- -40 to 119.375 °C
- Unit
- °C
Confirmed for 2022, 2024. In testing for 1988 to 2021, 2023, 2025 to 2026.
Engine independent HILUX_ENG_INDEPENDENT
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 91 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Engine independent control HILUX_ENG_INDEPENDENT_CTRL
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 88 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Engine oil pressure HILUX_EOPConfirmed
- Request
22 10 74 - Service 22
DID 1074 - Module
700 → 708 - Every
250 ms - Testing for 1988 to 2020, 2023, 2025 to 2026
Example reply from a 2024 Toyota Hilux.
Bits 0 to 15 of the reply, 16 bits.
0x008E = 142 → (142 × 10 ÷ 128) = 11.09375 kPa
- Formula
(val × 10 ÷ 128)- Range
- 0 to 5119.92 kPa
- Unit
- kPa
Confirmed for 2021 to 2022, 2024. In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2018.
Engine oil pressure control valve HILUX_EOP_CONTROL_VALVE
- Request
22 28 48 - Service 22
DID 2848 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0762939)- Range
- 0 to 4999.9207 mA
- Unit
- mA
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Engine oil temperature HILUX_EOTConfirmed
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Toyota Hilux.
Bits 72 to 79 of the reply, 8 bits.
0x00 = 0 → (0 − 40) = -40 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.
Engine oil temperature HILUX_EOT_700
Pelican can show this parameter as the engine oil temperature.
- Request
22 10 7B - Service 22
DID 107B - Module
700 → 708 - Every
5 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Engine oil temperature, previous trip HILUX_PREV_TRIP_EOTConfirmed
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Toyota Hilux.
Bits 80 to 87 of the reply, 8 bits.
0x00 = 0 → (0 − 40) = -40 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.
Engine oil temperature, variation 2 HILUX_EOT_V2
Pelican can show this parameter as the engine oil temperature.
- Request
22 1F 5C - Service 22
DID 1F5C - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2022. Supported for 2013, 2018, 2021, 2024 to 2025.
Engine run time HILUX_ENGINE_RUN_TIME
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Engine run time, up to 255 sec. only HILUX_ENG_RUN_TIME_UP_255
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 s
- Unit
- s
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Engine stall control FB flow HILUX_ENG_STALL_CTRL_FB
- Request
21 52 - Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096 − 40)- Range
- -40 to 39.99
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Engine start hesitation HILUX_ENG_START_HESIT
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Bit 237 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.
Engine starting time HILUX_ENG_START_TConfirmed
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Toyota Hilux.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 10) = 0 ms
- Formula
(val × 10)- Range
- 0 to 655350 ms
- Unit
- ms
Confirmed for 2018. In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.
EVAP purge duty HILUX_EVAP_PURGE_DUTY
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Evaporative purge duty HILUX_EVAP_PURGE_DUTY_7E0
- Request
21 2E - Service 21
PID 2E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Evaporative purge flow HILUX_EVAP_PURGE_FLOW
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 25 ÷ 4096)- Range
- 0 to 399.99 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Evaporative purge vacuum switching valve on HILUX_EVAP_PURGE_VSV_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 11 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Evaporator target temp HILUX_EVAP_TARG_TConfirmed
- Request
21 4C - Service 21
PID 4C - Module
7C4 → 7CC - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Toyota Hilux.
Bits 0 to 15 of the reply, 16 bits.
0x81C2 = 33218 → (33218 ÷ 100 − 327.68) = 4.5
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67
- Unit
- Number
Confirmed for 2022, 2024. In testing for 1988 to 2021, 2023, 2025 to 2026.
Exhaust gas recirculation step position HILUX_EGR_STEP_POSITION
- Request
21 47 - Service 21
PID 47 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Exhaust gas recirculation temperature HILUX_EGR_T
- Request
21 ED - Service 21
PID ED - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 53 ÷ 85)- Range
- 0 to 159 °C
- Unit
- °C
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Exhaust gas recirculation valve step HILUX_EGR_STEP
- Request
21 E7 - Service 21
PID E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Exhaust VVT oil control valve control duty HILUX_EXHAUST_VVT_OCV_CONTROL_DUTY
- Request
22 10 62 - Service 22
DID 1062 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 400 ÷ 65535)- Range
- 0 to 400 %
- Unit
- %
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Exhaust VVT target angle B1 HILUX_EXHAUST_VVT_TARGET_ANGLE_B1
- Request
22 10 71 - Service 22
DID 1071 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 639.9 ÷ 65535)- Range
- 0 to 639.9 °
- Unit
- °
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Fuel cut for engine stop request HILUX_F_C_ENG_STOP_REQ
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 92 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Fuel cut TAU on HILUX_FC_TAU_ON
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 127 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Fuel filter temperature HILUX_FFT
- Request
22 10 9A - Service 22
DID 109A - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
G sensor calibration, complete HILUX_G_SENS_CALIBRATION
- Request
21 83 - Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
G sensor learning value HILUX_G_SENS_LEARNING
- Request
21 83 - Service 21
PID 83 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Glass humidity HILUX_GLASS_HUMIDITY
- Request
21 B1 - Service 21
PID B1 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Glass temperature HILUX_GLASS_T
- Request
21 AF - Service 21
PID AF - Module
7C4 → 7CC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 500 − 557.8)- Range
- -557 to 621 °F
- Unit
- °F
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
HV communication open HILUX_HV_COMMUNICATION_OPEN
- Request
21 BE - Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Idle control HILUX_IDLE_CTRL
- Request
21 E6 - Service 21
PID E6 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Idle spark advance control 1 HILUX_IDLE_SPARK_ADVN_CTRL_1
- Request
21 52 - Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 16)- Range
- 0 to 15.93 °
- Unit
- °
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Idle spark advance control 2 HILUX_IDLE_SPARK_ADVN_CTRL_2
- Request
21 52 - Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 16)- Range
- 0 to 15.93 °
- Unit
- °
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Idle spark advance control 3 HILUX_IDLE_SPARK_ADVN_CTRL_3
- Request
21 52 - Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 16)- Range
- 0 to 15.93 °
- Unit
- °
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Idle spark advance control 4 HILUX_IDLE_SPARK_ADVN_CTRL_4
- Request
21 52 - Service 21
PID 52 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val ÷ 16)- Range
- 0 to 15.93 °
- Unit
- °
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Idle spark advance control, cylinder 1 HILUX_IDLE_SAC_CYL_1
- Request
22 10 78 - Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 6.25 ÷ 100)- Range
- 0 to 15.9375 °
- Unit
- °
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Idle spark advance control, cylinder 2 HILUX_IDLE_SAC_CYL_2
- Request
22 10 78 - Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 6.25 ÷ 100)- Range
- 0 to 15.9375 °
- Unit
- °
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Idle spark advance control, cylinder 3 HILUX_IDLE_SAC_CYL_3
- Request
22 10 78 - Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 6.25 ÷ 100)- Range
- 0 to 15.9375 °
- Unit
- °
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Idle spark advance control, cylinder 4 HILUX_IDLE_SAC_CYL_4
- Request
22 10 78 - Service 22
DID 1078 - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 6.25 ÷ 100)- Range
- 0 to 15.9375 °
- Unit
- °
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Idle speed control feedback HILUX_ISC_FB
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Bits 168 to 183 of the reply, 16 bits.
- Formula
(val × 10 ÷ 8192 − 40)- Range
- -40 to 39.99
- Unit
- Number
In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.
Idle speed control flow HILUX_ISC_FLOW
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val × 10 ÷ 8192)- Range
- 0 to 79.99
- Unit
- Number
In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.
Idle speed control learning HILUX_IDLE_SPD_CTRL
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 93 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Idle speed control learning value HILUX_ISC_LEARN
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val × 10 ÷ 8192 − 40)- Range
- -40 to 39.99
- Unit
- Number
In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.
Idle speed control learning value, l/s HILUX_IDLE_SPD_CTRL_L_S
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val × 0.0012206912)- Range
- 0 to 79.99
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Idle speed control position HILUX_ISC_POS
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Bits 136 to 151 of the reply, 16 bits.
- Formula
(val × 125 ÷ 16384)- Range
- 0 to 499.99 °
- Unit
- °
In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.
IG OFF elapsed time HILUX_IG_OFF_ELAPSED_TIME
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 min
- Unit
- min
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Ignition advance HILUX_IGN_ADVANCE
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °
- Unit
- °
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Ignition advance HILUX_SPARKADV_21
- Request
21 0E - Service 21
PID 0E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Immobilizer communication on HILUX_IMMOBILIZER_ON
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 120 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Initial engine coolant temperature HILUX_INITIAL_ECT
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 531 ÷ 850 − 40)- Range
- -40 to 119.3
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Initial intake air temperature HILUX_INITIAL_IAT
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 5 ÷ 8 − 40)- Range
- -40 to 119 °C
- Unit
- °C
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection HILUX_INJECTION
- Request
22 10 19 - Service 22
DID 1019 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | DIRECT | Direct |
2 | BOTH | Both |
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection duration for cylinder 1 HILUX_INJ_DUR_CYL_1
- Request
21 3C - Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection feedback value 1 HILUX_INJ_FEEDBACK_1Confirmed
- Request
22 11 2B - Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 0 to 7 of the reply, 8 bits.
0x7A = 122 → (122 × 5 ÷ 32 − 20) = -0.9375
- Formula
(val × 5 ÷ 32 − 20)- Range
- -20 to 15
- Unit
- Raw value
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Injection feedback value 1 HILUX_INJ_FEEDBACK_1_700
- Request
22 11 B8 - Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 332 ÷ 2125 − 19.99811765)- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection feedback value 2 HILUX_INJ_FEEDBACK_2Confirmed
- Request
22 11 2B - Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 8 to 15 of the reply, 8 bits.
0x7F = 127 → (127 × 5 ÷ 32 − 20) = -0.15625
- Formula
(val × 5 ÷ 32 − 20)- Range
- -20 to 15
- Unit
- Raw value
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Injection feedback value 2 HILUX_INJ_FEEDBACK_2_700
- Request
22 11 B8 - Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 332 ÷ 2125 − 19.99811765)- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection feedback value 3 HILUX_INJ_FEEDBACK_3Confirmed
- Request
22 11 2B - Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 16 to 23 of the reply, 8 bits.
0x83 = 131 → (131 × 5 ÷ 32 − 20) = 0.46875
- Formula
(val × 5 ÷ 32 − 20)- Range
- -20 to 15
- Unit
- Raw value
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Injection feedback value 3 HILUX_INJ_FEEDBACK_3_700
- Request
22 11 B8 - Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 332 ÷ 2125 − 19.99811765)- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection feedback value 4 HILUX_INJ_FEEDBACK_4Confirmed
- Request
22 11 2B - Service 22
DID 112B - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 24 to 31 of the reply, 8 bits.
0x81 = 129 → (129 × 5 ÷ 32 − 20) = 0.15625
- Formula
(val × 5 ÷ 32 − 20)- Range
- -20 to 15
- Unit
- Raw value
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Injection feedback value 4 HILUX_INJ_FEEDBACK_4_700
- Request
22 11 B8 - Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 332 ÷ 2125 − 19.99811765)- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection feedback value 5 HILUX_INJ_FEEDBACK_5
- Request
22 11 B8 - Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 332 ÷ 2125 − 19.99811765)- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection feedback value 6 HILUX_INJ_FEEDBACK_6
- Request
22 11 B8 - Service 22
DID 11B8 - Module
700 → 708 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 332 ÷ 2125 − 19.99811765)- Range
- -19.9981 to 19.8418
- Unit
- Raw value
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection volume HILUX_INJ_VOL
- Request
22 10 17 - Service 22
DID 1017 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 3200)- Range
- 0 to 20 L
- Unit
- L
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Injection volume - target HILUX_INJ_VOLUME_TGTConfirmed
- Request
22 11 2C - Service 22
DID 112C - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 19531 ÷ 1000000) = 0
- Formula
(val × 19531 ÷ 1000000)- Range
- 0 to 15
- Unit
- Raw value
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Injection volume 1 HILUX_INJ_VOLUME_1
- Request
22 11 8B - Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -40 to 300
- Unit
- Raw value
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection volume 2 HILUX_INJ_VOLUME_2
- Request
22 11 8B - Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -40 to 300
- Unit
- Raw value
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection volume 3 HILUX_INJ_VOLUME_3
- Request
22 11 8B - Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -40 to 300
- Unit
- Raw value
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection volume 5 HILUX_INJ_VOLUME_5
- Request
22 11 8B - Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -40 to 300
- Unit
- Raw value
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection volume 6 HILUX_INJ_VOLUME_6
- Request
22 11 8B - Service 22
DID 118B - Module
700 → 708 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -40 to 300
- Unit
- Raw value
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection volume per 10 injections, cylinder 1 HILUX_INJ_VOL_CYL_1
- Request
21 3C - Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32000000)- Range
- 0 to 0.002 L
- Unit
- L
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injection volume total HILUX_INJ_VOLUME_TOTConfirmed
- Request
22 11 2F - Service 22
DID 112F - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 1000000 − 640)- Range
- -640 to 15
- Unit
- Raw value
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Injector port HILUX_INJECTOR_PORT
- Request
22 10 18 - Service 22
DID 1018 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 ms
- Unit
- ms
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Injector pulse width HILUX_INJ_PW
- Request
21 E4 - Service 21
PID E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 163 ÷ 1275)- Range
- 0 to 32.6 ms
- Unit
- ms
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Injector pulse width HILUX_INJ_WIDTH
- Request
21 F3 - Service 21
PID F3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 16 ÷ 125)- Range
- 0 to 32.64 ms
- Unit
- ms
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Input shaft speed HILUX_SPD_NIN
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Intake air HILUX_INTAKE_AIR
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Intake air temperature HILUX_IAT_21
- Request
21 0F - Service 21
PID 0F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Intake air temperature, bank 1 sensor 1 HILUX_IAT_B1S1Confirmed
- Request
22 1F 77 - Service 22
DID 1F77 - Module
700 → 708 - Every
5 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 8 to 15 of the reply, 8 bits.
0x3E = 62 → (62 − 40) = 22 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Intake air temperature, bank 1 sensor 2 HILUX_IAT_B1S2Confirmed
- Request
22 1F 77 - Service 22
DID 1F77 - Module
700 → 708 - Every
5 s - Testing for 1988 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Hilux.
Bits 16 to 23 of the reply, 8 bits.
0x00 = 0 → (0 − 40) = -40 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Intake air temperature, previous trip HILUX_PREV_TRIP_IATConfirmed
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Toyota Hilux.
Bits 64 to 71 of the reply, 8 bits.
0x14 = 20 → (20 − 40) = -20 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.
Intake VVT change angle, bank 1 HILUX_INTAKE_VVT_CHANGE_ANGLE_BANK_1
- Request
22 10 87 - Service 22
DID 1087 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 639.9 ÷ 65535)- Range
- 0 to 639.9 °
- Unit
- °
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Intake VVT target angle B1 HILUX_INTAKE_VVT_TARGET_ANGLE_B1
- Request
22 10 6F - Service 22
DID 106F - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 639.9 ÷ 65535)- Range
- 0 to 639.9 °
- Unit
- °
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Integrated engine run time HILUX_INTEGRATED_ENG_RUN
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 h
- Unit
- h
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Intercooler coolant temperature HILUX_INTERCOOLER_ECT
- Request
22 11 9C - Service 22
DID 119C - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Intercooler water pump HILUX_INTERCOOLER_WATER
- Request
22 28 20 - Service 22
DID 2820 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 80 ÷ 13107)- Range
- 0 to 300 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Internal temperature HILUX_ECU_INTERNAL_T
- Request
22 10 5E - Service 22
DID 105E - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Judge time engine ignition HILUX_JUDGE_TIME_ENG_IGN
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 s
- Unit
- s
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Judge time engine output HILUX_JUDGE_TIME_ENG
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 s
- Unit
- s
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Knock adjust HILUX_KNOCK_ADJUST
- Request
21 B2 - Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2048 ÷ 65535 − 64)- Range
- -64 to 1984 °
- Unit
- °
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Knock adjust HILUX_KNOCK_ADJUST_7E0
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 2048 ÷ 65535 − 1024)- Range
- -1024 to 1024 °
- Unit
- °
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Knock correct learn value HILUX_KNOCK_CORRECT_LEARN
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 32 − 1024)- Range
- -1024 to 1023 °
- Unit
- °
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Knock correction, learned value HILUX_KNOCK_CORRECT_LEARNED_VALUE
- Request
22 10 5C - Service 22
DID 105C - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 312.5 ÷ 10000 − 1024)- Range
- -1024 to 1023
- Unit
- Number
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Knock feedback HILUX_KNOCK_FEEDBACK
- Request
21 B2 - Service 21
PID B2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 2048 ÷ 65535 − 64)- Range
- -64 to 1984 °
- Unit
- °
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Knock feedback HILUX_KNOCK_FEEDBACK_7E0
- Request
21 37 - Service 21
PID 37 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 2048 ÷ 65535 − 1024)- Range
- -1024 to 1024 °
- Unit
- °
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Knock feedback value HILUX_KNOCK_FEEDBACK_VALUE
- Request
22 10 5C - Service 22
DID 105C - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 312.5 ÷ 10000 − 1024)- Range
- -1024 to 1023
- Unit
- Number
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Long FT B1S1 HILUX_LONG_FT_B1S1
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 200 ÷ 256 − 100)- Range
- -100 to 99.218 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Long-term fuel trim, bank 1 HILUX_LTFT1_21
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.7809803922 − 100)- Range
- -100 to 99.15 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Low revolution control HILUX_LOW_RPM_CTRL
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Bit 234 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.
Low revolution for engine start HILUX_LOW_RPM_START
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Bit 236 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.
Main idle HILUX_MAIN_IDLE
- Request
21 1D - Service 21
PID 1D - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
MAP HILUX_MAP
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Mass air flow HILUX_MAF
Pelican can show this parameter as the mass air flow.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
val- Range
- 0 to 655.35 g/s
- Unit
- g/s
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Mass air flow HILUX_MAF_21
- Request
21 10 - Service 21
PID 10 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 g/s
- Unit
- g/s
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Master cylinder open HILUX_MASTER_CYLINDER_OPEN
- Request
21 BE - Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 8 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Master cylinder sensor temperature HILUX_MASTER_CYL_TEMPConfirmed
- Request
22 10 06 - Service 22
DID 1006 - Module
7B0 → 7B8 - Every
5 s - Testing for 1988 to 2020, 2023, 2025 to 2026
Example reply from a 2024 Toyota Hilux.
Bits 0 to 7 of the reply, 8 bits.
0x77 = 119 → (119 − 80) = 39 °C
- Formula
(val − 80)- Range
- -20 to 100 °C
- Unit
- °C
Confirmed for 2021 to 2022, 2024. In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2018.
Misfire count, all cylinders HILUX_MISFIRE_CNT
- Request
22 10 A5 - Service 22
DID 10A5 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Misfire count, cylinder 1 HILUX_MISFIRE_CYL1
- Request
22 10 A7 - Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Misfire count, cylinder 2 HILUX_MISFIRE_CYL2
- Request
22 10 A7 - Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Misfire count, cylinder 3 HILUX_MISFIRE_CYL3
- Request
22 10 A7 - Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Misfire count, cylinder 4 HILUX_MISFIRE_CYL4
- Request
22 10 A7 - Service 22
DID 10A7 - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Misfire load HILUX_MISFIRE_LOAD_700
- Request
22 10 AA - Service 22
DID 10AA - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 510 ÷ 255)- Range
- 0 to 510 %
- Unit
- %
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Misfire margin HILUX_MISFIRE_MARGIN_700
- Request
22 10 AA - Service 22
DID 10AA - Module
700 → 708 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 rpm
- Unit
- rpm
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Misfire RPM HILUX_MISFIRE_RPM
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Misfire RPM HILUX_MISFIRE_RPM_700
- Request
22 10 AA - Service 22
DID 10AA - Module
700 → 708 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 6375 ÷ 255)- Range
- 0 to 6375 rpm
- Unit
- rpm
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Misfire test result, incomplete HILUX_MIS_TEST_RESULT
- Request
21 E3 - Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Model year HILUX_MODEL_YEAR
- Request
21 C1 - Service 21
PID C1 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val + 1900)- Range
- 1900 to 2155
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
O2 heater b1s2_active HILUX_O2_HEATER_B1S2
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 68 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
O2 heater current val bank 1 sensor 2 HILUX_O2_HEATER_CURR_VAL
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 A
- Unit
- A
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
O2S B1S2 HILUX_O2S_B1S2
- Request
21 04 - Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 5 ÷ 1000)- Range
- 0 to 1.275 V
- Unit
- V
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Open side malfunction on HILUX_OPEN_SIDE_ON
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 145 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Output shaft speed HILUX_SPD_NOUT
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
OXS1, A/FS2 test result, incomplete HILUX_OXS1_FS2_TEST_RESULT
- Request
21 E3 - Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Oxygen sensor voltage, bank 1 sensor 1 HILUX_O2S11_V
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.0049960784)- Range
- 0 to 1.27 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
PM accumulation ratio - bank 1 HILUX_PM_ACCUMULATION_RAT_1Confirmed
- Request
22 11 05 - Service 22
DID 1105 - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023 to 2026
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 15 %
- Unit
- %
Confirmed for 2022. In testing for 1988 to 2021, 2023 to 2026.
Purge cut vacuum switching valve duty HILUX_PURGE_CUT_VSV_DUTY
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 25 ÷ 4096)- Range
- 0 to 399.9 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Racing operation HILUX_RACING_OPERATION
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 90 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Regulator pressure HILUX_REGULATOR_P
- Request
21 53 - Service 21
PID 53 - Module
7C4 → 7CC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 375105 ÷ 25500 − 456.68)- Range
- -456.68 to 3294 kPa
- Unit
- kPa
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Request engine run time HILUX_REQ_ENG_RUN_TIME
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 s
- Unit
- s
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Request warm-up HILUX_REQ_WARM_UP
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 89 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Requested engine torque HILUX_REQ_ENG_TQ
- Request
21 49 - Service 21
PID 49 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Rough idle cyl.1 HILUX_ROUGH_IDLE_1Confirmed
- Request
22 10 84 - Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Toyota Hilux.
Bit 31 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022, 2024. In testing for 1988 to 2021, 2023, 2026. Not supported for 2025.
Rough idle cyl.2 HILUX_ROUGH_IDLE_2Confirmed
- Request
22 10 84 - Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Toyota Hilux.
Bit 30 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022, 2024. In testing for 1988 to 2021, 2023, 2026. Not supported for 2025.
Rough idle cyl.3 HILUX_ROUGH_IDLE_3Confirmed
- Request
22 10 84 - Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Toyota Hilux.
Bit 29 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022, 2024. In testing for 1988 to 2021, 2023, 2026. Not supported for 2025.
Rough idle cyl.4 HILUX_ROUGH_IDLE_4Confirmed
- Request
22 10 84 - Service 22
DID 1084 - Module
700 → 708 - Every
1 s - Testing for 1988 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Toyota Hilux.
Bit 28 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2022, 2024. In testing for 1988 to 2021, 2023, 2026. Not supported for 2025.
Short FT B1S1 HILUX_SHORT_FT_B1S1
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 200 ÷ 256 − 100)- Range
- -100 to 99.218 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Starter count HILUX_STARTER_CNTConfirmed
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Toyota Hilux.
Bits 33 to 39 of the reply, 7 bits.
0b0000001 = 1 → 1
- Formula
val- Range
- 0 to 127
- Unit
- Number
Confirmed for 2018. In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.
Starter relay on HILUX_STARTER_RELAY_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 47 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Stroke open HILUX_STROKE_OPEN
- Request
21 BE - Service 21
PID BE - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 10 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
System guard on HILUX_SYSTEM_GUARD_ON
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 144 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Throttle fully close learn HILUX_THROTTLE_FULLY_CLOSE
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Throttle idle position on HILUX_THROTTLE_IDLE_POS_ON
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 149 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Throttle motor current HILUX_THROTTLE_MOTOR
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val × 5 ÷ 64)- Range
- 0 to 19.9 A
- Unit
- A
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Throttle motor DUTY HILUX_THROTTLE_MOTOR_DUTY
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Throttle motor duty, close HILUX_THROTTLE_MOTOR_DUTY_CLOSE
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Throttle motor duty, open HILUX_THROTTLE_MOTOR_DUTY_OPEN
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Throttle position HILUX_THROTTLE_21
- Request
21 11 - Service 21
PID 11 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Throttle position HILUX_TPS
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val × 125 ÷ 16384)- Range
- 0 to 499.99 °
- Unit
- °
In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.
Throttle position command HILUX_THROTTLE_POS_COMMAND
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Throttle position, number 1 HILUX_THROTTLE_POS_NUMBER_1
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Throttle position, number 2 HILUX_THROTTLE_POS_NUMBER_2
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Throttle require position HILUX_THROTTLE_REQUIRE_POS
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Throttle sensor open position 1 HILUX_THROTTLE_SENS_OPEN_1
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Throttle sensor open position 2 HILUX_THROTTLE_SENS_OPEN_2
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Throttle sensor position HILUX_THROTTLE_SENSOR_POSITION
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Throttle sensor volt %, 1 HILUX_THROTTLE_SENSOR_VOLT
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Throttle sensor volt %, 2 HILUX_THROTTL_SENSOR_2_VOLT
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Time after DTC cleared HILUX_TIME_AFTER_DTC_CLEARED
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Total fuel trim, bank 1 HILUX_TOT_FT_1
- Request
21 3C - Service 21
PID 3C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 256 − 50)- Range
- -50 to 49.6 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Transmission fluid temperature HILUX_ATF_T
- Request
01 B4 - Service 01
PID B4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Transmission fluid temperature HILUX_ATF_TEMP_700
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 16 38 - Service 22
DID 1638 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2018, 2021 to 2022, 2024.
Transmission output shaft speed HILUX_TRANS_OUT_RPM
- Request
21 BD - Service 21
PID BD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Turbine speed HILUX_SPD_NT
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 rpm
- Unit
- rpm
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Valvematic current angle HILUX_VALVEMATIC_CURRENT
- Request
21 31 - Service 21
PID 31 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 512)- Range
- 0 to 639.9 °
- Unit
- °
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Valvematic, target angle HILUX_VALVEMATIC_TGT_ANG
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 512)- Range
- 0 to 639.9 °
- Unit
- °
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Variable valve timing advance fail HILUX_VVT_ADV_FAIL
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Bit 235 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Supported for 2018. Not supported for 2013, 2021 to 2022, 2024.
Variable valve timing aim angle 1 HILUX_VARIABLE_VLV_TIM_AIM_1
- Request
21 44 - Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1333 ÷ 218450)- Range
- 0 to 399 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Variable valve timing change angle 1 HILUX_VARIABLE_VLV_TIM_1
- Request
21 44 - Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 0.0097642481)- Range
- 0 to 639 °
- Unit
- °
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Variable valve timing control status 1 on HILUX_VARIABLE_VLV_TIM_1_ON
- Request
21 39 - Service 21
PID 39 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Variable valve timing oil control valve duty 1 HILUX_VARIABLE_VLV_TIM_OIL_1
- Request
21 44 - Service 21
PID 44 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0061020829)- Range
- 0 to 399 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Variable valve timing oil temperature HILUX_VVTOTConfirmed
- Request
21 51 - Service 21
PID 51 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2017, 2019 to 2026
Example reply from a 2018 Toyota Hilux.
Bits 56 to 63 of the reply, 8 bits.
0x12 = 18 → (18 − 40) = -22 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018. In testing for 1988 to 2012, 2014 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2013, 2021 to 2022, 2024.
Variable valve timing opening angle bank 1 HILUX_VVT_IE_OPENING_ANGLE_BANK_1
- Request
22 28 43 - Service 22
DID 2843 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Vehicle load HILUX_VEHICLE_LOAD
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val × 100 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Vehicle speed HILUX_VSS_21
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Vehicle speed sensor test result, incomplete HILUX_SPD_TEST_RESULT
- Request
21 E3 - Service 21
PID E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1988 to 2021, 2023 to 2026. Not supported for 2022.
Warmup cycle cleared DTC HILUX_WARMUP_CYCLE_CLEARED_DTC
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Engine › Catalyst
Catalyst temperature, bank 1 sensor 1 HILUX_CAT_T_11
- Request
22 1F 3C - Service 22
DID 1F3C - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Catalyst temperature, bank 1 sensor 2 HILUX_CAT_T_12
- Request
22 1F 3E - Service 22
DID 1F3E - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1988 to 2017, 2019 to 2020, 2023, 2025 to 2026. Not supported for 2018, 2021 to 2022, 2024.
Engine › Internal
Actual EGR A supported EGR_A_ACT_SUPSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Actual EGR A supported EGR_B_ACT_SUPSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Commanded EGR A supported EGR_A_CMD_SUPSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Commanded EGR A supported EGR_B_CMD_SUPSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
EGR A error supported EGR_A_ERR_SUPSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
EGR A error supported EGR_B_ERR_SUPSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018. Supported for 2021 to 2022, 2024 to 2025.
Engine › Misfires
All cylinders misfire count HILUX_ALL_CYLINDERS_MISFIRE_CNT
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Cylinder #1 misfire count HILUX_CYL1_MISFIRE_CNT
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Cylinder #2 misfire count HILUX_CYL2_MISFIRE_CNT
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Cylinder #3 misfire count HILUX_CYL3_MISFIRE_CNT
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Cylinder #4 misfire count HILUX_CYL4_MISFIRE_CNT
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Misfire load HILUX_MISFIRE_LOAD
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 4 ÷ 256)- Range
- 0 to 3.98
- Unit
- Number
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.
Misfire margin HILUX_MISFIRE_MARGIN
- Request
21 45 - Service 21
PID 45 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 %
- Unit
- %
In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.