Toyota Hilux

ECU parameters

The Toyota Hilux has 6 ECU parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Exhaust VVT change angle bank 1 HILUX_EXHAUST_VVT_CHANGE_ANGLE_1

  • Request22 10 88
  • Service 22DID 1088
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Exhaust VVT change angle bank 1 HILUX_EXHAUST_VVT_CHANGE_ANGLE_1

  • Request22 10 88
  • Service 22DID 1088
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 639.9 ÷ 65535)
Range
0 to 639.9 °
Unit
°

In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust VVT hold learn value bank 1 HILUX_EXHAUST_VVT_HOLD_LEARN_VALUE_1

  • Request22 10 89
  • Service 22DID 1089
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 399.9 ÷ 65535)
Range
0 to 100 %
Unit
%

In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Exhaust VVT timing most over-advanced learn value bank 1 HILUX_EXHAUST_VVT_TIMING_MOST_OVER_ADVANCED_LEARN_VALUE_1

  • Request22 10 8F
  • Service 22DID 108F
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 639.99 ÷ 65535)
Range
0 to 639.99 °
Unit
°

In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Intake VVT most over-retarded learn value bank 1 HILUX_INTAKE_VVT_MOST_OVER_RETARDED_LEARN_VALUE_1

  • Request22 10 8D
  • Service 22DID 108D
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 639.99 ÷ 65535)
Range
0 to 639.99 °
Unit
°

In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

VVT-ie duty ratio bank 1 HILUX_VVT_IE_DUTY_RATIO_1

  • Request22 10 8A
  • Service 22DID 108A
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 14 of the reply, 15 bits.

Formula
(val × 399.9 ÷ 65535 − 200)
Range
-200 to -0.0531 %
Unit
%

In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

VVT-ie motor direction: forward bank 1 HILUX_VVT_IE_MOTOR_DIRECTION_FORWARD_1

  • Request22 10 8A
  • Service 22DID 108A
  • Module700 → 708
  • Every1 s
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 2021, 2023, 2025 to 2026. Not supported for 2022, 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.