Toyota Corolla Cross

Seatbelt parameters

The Toyota Corolla Cross has 4 seatbelt parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Reverse beep CCROSS_REVERSE_BEEP

  • Request21 AC
  • Service 21PID AC
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
On or off

In testing for 2020 to 2021, 2024. Not supported for 2022 to 2023, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Reverse beep CCROSS_REVERSE_BEEP

  • Request21 AC
  • Service 21PID AC
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
On or off

In testing for 2020 to 2021, 2024. Not supported for 2022 to 2023, 2025 to 2026.

Seat belt beep, driver CCROSS_SEAT_BELT_BEEP_DRIVER

  • Request21 A7
  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2021, 2024. Not supported for 2022 to 2023, 2025 to 2026.

Seat belt beep, passenger CCROSS_SEAT_BELT_BEEP_PASSENGER

  • Request21 A7
  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2021, 2024. Not supported for 2022 to 2023, 2025 to 2026.

Seat belt beep, reminder CCROSS_SEAT_BELT_BEEP_REMINDER

  • Request21 A7
  • Service 21PID A7
  • Module7C0 → 7C8
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2020 to 2021, 2024. Not supported for 2022 to 2023, 2025 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.