Toyota Corolla Cross

Climate parameters

The Toyota Corolla Cross has 13 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Adjusted ambient temperature CCROSS_ADJUSTED_AMBIENT_TConfirmed

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Corolla Cross.

Bits 0 to 7 of the reply, 8 bits.

0xB2 = 178 → (178 × 81.6 ÷ 255 − 30.8) = 26.16 °C

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Adjusted ambient temperature CCROSS_ADJUSTED_AMBIENT_TConfirmed

  • Request21 3D
  • Service 21PID 3D
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Corolla Cross.

Bits 0 to 7 of the reply, 8 bits.

0xB2 = 178 → (178 × 81.6 ÷ 255 − 30.8) = 26.16 °C

Formula
(val × 81.6 ÷ 255 − 30.8)
Range
-30.8 to 50.8 °C
Unit
°C

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Air inlet damper actual pulse CCROSS_AIR_INLET_DAMPER_ACTUAL_PULSEConfirmed

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Air inlet damper target pulse CCROSS_AIR_INLET_DAMPER_TARGET_PULSEConfirmed

  • Request21 44
  • Service 21PID 44
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Air outlet servo actual pulse, driver CCROSS_AIR_OUTLET_SERVO_ACTU_PULSE_DConfirmed

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Air outlet servo pulse, driver CCROSS_AIR_OUTLET_SERVO_PULSE_DConfirmed

  • Request21 43
  • Service 21PID 43
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Ambient air temperature CCROSS_AAT_7C4Confirmed

  • Request21 22
  • Service 21PID 22
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Corolla Cross.

Bits 0 to 7 of the reply, 8 bits.

0x8F = 143 → (143 × 89.25 ÷ 255 − 23.3) = 26.75 °C

Formula
(val × 89.25 ÷ 255 − 23.3)
Range
-23.3 to 65.95 °C
Unit
°C

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Ambient temperature CCROSS_AMBIENT_TConfirmed

  • Request22 1F 46
  • Service 22DID 1F46
  • Module700 → 708
  • Every5 s
  • Testing for 2020 to 2021, 2024

Example reply from a 2026 Toyota Corolla Cross.

Bits 0 to 7 of the reply, 8 bits.

0x39 = 57 → (57 − 40) = 17 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2023, 2025 to 2026. In testing for 2020 to 2021, 2024.

Blower motor speed level CCROSS_BLOWER_MOTOR_SPEED_LEVELConfirmed

  • Request21 3C
  • Service 21PID 3C
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Corolla Cross.

Bits 0 to 7 of the reply, 8 bits.

0x01 = 1 → 1

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Cabin temperature CCROSS_CABIN_TConfirmed

  • Request21 21
  • Service 21PID 21
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Corolla Cross.

Bits 0 to 7 of the reply, 8 bits.

0x87 = 135 → (135 × 63.75 ÷ 255 − 6.5) = 27.25 °C

Formula
(val × 63.75 ÷ 255 − 6.5)
Range
-6.5 to 57.25 °C
Unit
°C

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Evaporator fin thermistor CCROSS_EVAP_FIN_THERMISTORConfirmed

  • Request21 4B
  • Service 21PID 4B
  • Module7C4 → 7CC
  • Every5 s
  • Testing for 2020 to 2022, 2024 to 2026

Example reply from a 2023 Toyota Corolla Cross.

Bits 0 to 7 of the reply, 8 bits.

0x5E = 94 → (94 × 89.25 ÷ 255 − 29.7) = 3.2 °C

Formula
(val × 89.25 ÷ 255 − 29.7)
Range
-29.7 to 59.55 °C
Unit
°C

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Evaporator target temperature CCROSS_EVAP_TARGET_TConfirmed

  • Request21 4C
  • Service 21PID 4C
  • Module7C4 → 7CC
  • Every1 s
  • Testing for 2020 to 2022, 2024 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100 − 327.68)
Range
-327.68 to 327.67
Unit
Number

Confirmed for 2023. In testing for 2020 to 2021, 2024. Not supported for 2022, 2025 to 2026.

Set temperature, driver side CCROSS_T_DRIVER

  • Request21 29
  • Service 21PID 29
  • Module7C4 → 7CC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °C
Unit
°C

In testing for 2020 to 2021, 2024. Not supported for 2022 to 2023, 2025 to 2026.

Solar sensor, driver side CCROSS_SOLAR_DRIVER

  • Request21 24
  • Service 21PID 24
  • Module7C4 → 7CC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2021, 2024. Not supported for 2022 to 2023, 2025 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.