DTC parameters
The Toyota 4Runner has 76 DTC parameters.
● Confirmed◆ In testing○ Supported× Not supported
2nd air monitor available? 4RUNNER_2ND_AIR_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 20 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
2nd air monitor incomplete? 4RUNNER_2ND_AIR_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 28 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
A/C monitor available? 4RUNNER_A_C_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 19 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
A/C monitor incomplete? 4RUNNER_A_C_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 27 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Catalyst monitor available? 4RUNNER_CATALYST_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 23 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Catalyst monitor incomplete? 4RUNNER_CATALYST_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 31 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Complete parts monitor available? 4RUNNER_COMPLETE_PARTS_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 13 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
01 31 - Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2005 to 2006, 2010 to 2024. Supported for 2008, 2025 to 2026.
Distance traveled while MIL was activated MIL_DISTSAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Request
01 21 - Service 01
PID 21 - Module
7E0 → 7E8 - Every
5 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2010, 2013 to 2014, 2016 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2015, 2022, 2025 to 2026.
EGR/VVT monitor available? 4RUNNER_EGR_VVT_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 16 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
EGR/VVT monitor incomplete? 4RUNNER_EGR_VVT_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 24 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Engine run time since diagnostic trouble codes cleared CLR_TIMESAE J1979Confirmed
Time accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 minutes and not wrap to zero.
- Request
01 4E - Service 01
PID 4E - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2010, 2013 to 2014, 2016 to 2021, 2023 to 2024. Supported for 2025 to 2026.
EVAP monitor available? 4RUNNER_EVAP_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 21 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
EVAP monitor_icmpl 4RUNNER_EVAP_MONITOR_ICMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 29 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Fuel system monitor available? 4RUNNER_FUEL_SYSTEM_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 14 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Heated catalyst monitor available? 4RUNNER_HEATED_CATALYST_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 22 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Heated catalyst monitor incomplete? 4RUNNER_HEATED_CATALYST_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 30 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
Pelican can show this parameter as the checkEngineLightOn.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
MIL 4RUNNER_MILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 0 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
MIL ON run distance 4RUNNER_MILON_RUN_DISTANCEConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bits 48 to 63 of the reply, 16 bits.
0x0000 = 0 → 0 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Misfire monitor available? 4RUNNER_MISFIRE_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 15 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
Pelican can show this parameter as the storedDTCCount.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127
- Unit
- Number
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Number of emission DTC 4RUNNER_NUMBER_OF_EMISSION_DTCConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bits 1 to 7 of the reply, 7 bits.
0b0000000 = 0 → 0
- Formula
val- Range
- 0 to 127
- Unit
- Number
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Number of warm-ups since diagnostic trouble codes cleared WARM_UPSSAE J1979Confirmed
Number of OBD warm-up cycles since all DTCs were cleared (via an external test equipment or possibly, a battery disconnect). A warm-up is defined in the OBD regulations to be sufficient vehicle operation such that coolant temperature rises by at least 22°C (40°F) from engine starting and reaches a minimum temperature of 70°C (160°F) (60°C (140°F) for diesels). This PID is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 255 warm-ups have occurred, this parameter will remain at 255 and not wrap to zero.
- Request
01 30 - Service 01
PID 30 - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2010, 2013 to 2014, 2016 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2015, 2022, 2025 to 2026.
O2S heater monitor available? 4RUNNER_O2S_A_FS_HEATER_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 17 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
O2S heater monitor incomplete? 4RUNNER_O2S_A_FS_HEATER_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 25 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
O2S monitor available? 4RUNNER_O2S_A_FS_MONITOR_AVAILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 18 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
O2S monitor incomplete? 4RUNNER_O2S_A_FS_MONITOR_INCMPLConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bit 26 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Running time from MIL ON 4RUNNER_RUNNING_TIME_FROM_MIL_ONConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2026
Example reply from a 2020 Toyota 4Runner.
Bits 64 to 79 of the reply, 16 bits.
0x0027 = 39 → 39 min
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2013, 2015 to 2016, 2020. In testing for 1988 to 2012, 2014, 2017 to 2019, 2021 to 2024, 2026. Not supported for 2025.
Time run by the engine while MIL was activated MIL_TIMESAE J1979Confirmed
Resets to zero when MIL changes from deactivated to activated, if diagnostic information is cleared, or if at least 40 warm-up cycles occur without MIL being activated.
- Request
01 4D - Service 01
PID 4D - Module
7E0 → 7E8 - Every
60 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
Confirmed for 2010, 2013 to 2014, 2016 to 2021, 2023 to 2024. Supported for 2025 to 2026.
DTCs › Status
A/C system refrigerant monitoring ACRF_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 19 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
A/C system refrigerant monitoring completed ACRFCMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
A/C system refrigerant monitoring ready ACRF_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Catalyst monitoring CAT_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Catalyst monitoring completed CAT_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Catalyst monitoring ready CAT_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Comprehensive component monitoring completed CCM_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 9 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Comprehensive component monitoring ready CCM_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 9 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
EGR system monitoring EGR_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
EGR system monitoring completed EGR_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
EGR system monitoring ready EGR_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Evaporative system monitoring EVAP_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Evaporative system monitoring completed EVAPCMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Evaporative system monitoring ready EVAP_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Fuel system monitoring completed FUEL_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 10 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Fuel system monitoring ready FUEL_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 10 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Heated catalyst monitoring HCAT_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Heated catalyst monitoring completed HCATCMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Heated catalyst monitoring ready HCAT_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Misfire monitoring completed MIS_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 11 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Misfire monitoring ready MIS_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 11 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Oxygen sensor heater monitoring HTR_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Oxygen sensor heater monitoring completed HTR_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Oxygen sensor heater monitoring ready HTR_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Oxygen sensor monitoring O2S_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 18 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Oxygen sensor monitoring completed O2S_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Oxygen sensor monitoring ready O2S_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Secondary air system monitoring AIR_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Secondary air system monitoring completed AIR_CMPLSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Secondary air system monitoring ready AIR_RDYSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
DTCs › Support
A/C system refrigerant monitoring supported ACRF_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 19 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Catalyst monitoring supported CAT_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Comprehensive component monitoring enabled CCM_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Comprehensive component monitoring supported CCM_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Compression ignition monitoring supported CIM_SUPSAE J1979Confirmed
Indicates support of spark ignition or compression ignition monitors.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Compression ignition monitoring supported CIM_SUP_FLAGSAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 12 of the reply.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | SPARK | Spark ignition monitors supported |
1 | COMPRESSION | Compression ignition monitors supported |
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
EGR system monitoring supported EGR_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Evaporative system monitoring supported EVAP_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Fuel system monitoring enabled FUEL_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Fuel system monitoring supported FUEL_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Heated catalyst monitoring supported HCAT_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Misfire monitoring enabled MIS_ENASAE J1979Confirmed
- Request
01 41 - Service 01
PID 41 - Module
7E0 → 7E8 - Every
1 s
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2015 to 2016, 2018, 2020, 2023. Supported for 2005, 2008, 2010 to 2012, 2014, 2017, 2021 to 2022, 2025 to 2026.
Misfire monitoring supported MIS_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Oxygen sensor heater monitoring supported HTR_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Oxygen sensor monitoring supported O2S_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 18 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.
Secondary air system monitoring supported AIR_SUPSAE J1979Confirmed
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2010, 2013 to 2021, 2023 to 2024. Supported for 2005 to 2006, 2008, 2011 to 2012, 2022, 2025 to 2026.