Peugeot 508

Engine parameters

The Peugeot 508 has 234 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

5V power supply state number 1 508_5V_POWER_SUP_ST_1

  • Request22 D4 23
  • Service 22DID D423
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

5V power supply state number 1 508_5V_POWER_SUP_ST_1

  • Request22 D4 23
  • Service 22DID D423
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

5V power supply state number 2 508_5V_POWER_SUP_ST_2

  • Request22 D4 24
  • Service 22DID D424
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

5V power supply state number 3 508_5V_POWER_SUP_ST_3

  • Request22 D4 25
  • Service 22DID D425
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

5V power supply state number 4 508_5V_POWER_SUP_ST_4

  • Request22 D4 26
  • Service 22DID D426
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

12V network allowed stop 508_12V_NETWORK_ALLOWED

  • Request22 D7 4C
  • Service 22DID D74C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, brake electromagnetic valve B1 508_NUM_ACTIVATIONS_B1

  • Request22 D7 45
  • Service 22DID D745
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, line pressure control solenoid 508_NUM_LINE_P_CTRL

  • Request22 D7 51
  • Service 22DID D751
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, the electromagnetic valve of brake B2 508_NUM_ACTIVATIONS_B2

  • Request22 D7 5A
  • Service 22DID D75A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Actual oil pressure 508_ACT_OIL_P

  • Request21 C5
  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 144 to 151 of the reply, 8 bits.

Formula
(val ÷ 20)
Range
0 to 12.75 bar
Unit
bar

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Additional heater control 1 508_ADDITIONAL_HEATER_1

  • Request22 D4 16
  • Service 22DID D416
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Air conditioning 508_AC

  • Request22 D4 AF
  • Service 22DID D4AF
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Air conditioning compressor current 508_AC_COMP_CURRENT

  • Request22 D4 1C
  • Service 22DID D41C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Air conditioning pressure 508_AC_P

  • Request22 D4 21
  • Service 22DID D421
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 bar
Unit
bar

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Air doser first electronic loading 508_AIR_DOSER_FIRST

  • Request22 D5 3B
  • Service 22DID D53B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Air flow 508_AIR_FLOW

  • Request22 D4 89
  • Service 22DID D489
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2014, 2019, 2021. Supported for 2012, 2015.

Air flow target 508_AIR_FLOW_TGT

  • Request22 D4 8E
  • Service 22DID D48E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Air metering valve duty cycle 508_AIR_METERING_VLV

  • Request22 D4 61
  • Service 22DID D461
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Air metering valve position 508_AIR_METERING_VLV_POS

  • Request22 D5 4F
  • Service 22DID D54F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Air metering valve, target position 508_AIR_METERING_VLV_TGT

  • Request22 D4 60
  • Service 22DID D460
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Air temperature by air flow meter 508_AIR_T_AIR_FLOW_METER

  • Request22 D5 4E
  • Service 22DID D54E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Alternator load value 508_ALTERNATOR_LOAD

  • Request22 D4 A5
  • Service 22DID D4A5
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Ambient air temperature 508_AAT_6A9

  • Request22 D5 52
  • Service 22DID D552
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

ANTI START PROGRAMMING STATUS 508_ANTI_START

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Assessment of thermal aging of the particulate filter 508_ASSESSMENT_THERMAL

  • Request22 D5 32
  • Service 22DID D532
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 25 ÷ 128)
Range
0 to 12799 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Atmospheric pressure 508_ATMOSPHERIC_P

  • Request22 D4 65
  • Service 22DID D465
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic restart request from body control module 508_AUTOMATIC_RESTART_REQ_BSI

  • Request22 D7 0A
  • Service 22DID D70A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic restart request from engine management computer 508_AUTOMATIC_RESTART

  • Request22 D7 09
  • Service 22DID D709
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic stop allowed by body control module 508_AUTOMATIC_STOP

  • Request22 D7 03
  • Service 22DID D703
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic stop allowed by power steering computer 508_AUTOMATIC_STOP_ALLOWED_POWER_STEER

  • Request22 D7 05
  • Service 22DID D705
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Auxiliary heater 2 control 508_AUXILIARY_HEATER_2

  • Request22 D4 17
  • Service 22DID D417
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Average mileage for the last 10 regenerations 508_AVG_MILEAGE_LAST_10

  • Request22 D5 25
  • Service 22DID D525
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 16)
Range
0 to 4095 km
Unit
km

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2014, 2019. Supported for 2012, 2015, 2021.

Boost air temperature 508_BOOST_AIR_T

  • Request22 D4 11
  • Service 22DID D411
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Button state 508_BUTTON_ST

  • Request22 D5 17
  • Service 22DID D517
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2014, 2019, 2021. Supported for 2012, 2015.

Camshaft/crankshaft position synchronization 508_CAM_CRANK_POS

  • Request22 D4 18
  • Service 22DID D418
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2019. Supported for 2021.

CHANGE REPORT IN PROGRESS 508_CHANGE_REPORT

  • Request22 D5 16
  • Service 22DID D516
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Closed loop soot load assessment of the diesel particulate filter 508_CLOSED_LOOP_SOOT

  • Request22 D5 4B
  • Service 22DID D54B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1024)
Range
0 to 63.99 g/L
Unit
g/L

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Combustion engine state 508_ICE_ST

  • Request22 D7 09
  • Service 22DID D709
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Request01 2C
  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2019.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2021.

Commanded oil pressure 508_CMD_OIL_P

  • Request21 C5
  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 bar
Unit
bar

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2019. Supported for 2021.

Commanded wastegate A position WG_A_CMDSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2019.

Commanded wastegate B position WG_B_CMDSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2019.

Computer lock 508_COMPUTER_LOCK

  • Request22 DA DD
  • Service 22DID DADD
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Computer remote wake-up state 508_COMPUTER_WAKE_UP_ST

  • Request22 D5 15
  • Service 22DID D515
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Computer restarts since memory erase 508_CNT_NUM_RE

  • Request22 D4 D8
  • Service 22DID D4D8
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Computer temperature 508_COMPUTER_T

  • Request22 D4 35
  • Service 22DID D435
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of electromagnetic valve for changing the pressure in the brake system B2 508_CTRL_CURRENT_P_B2

  • Request22 D6 22
  • Service 22DID D622
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of the electromagnetic valve for changing the pressure in the brake system B1 508_CTRL_CURRENT_P_B1

  • Request22 D6 08
  • Service 22DID D608
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Controlled air supply module 508_CONTROLLED_AIR_SUP

  • Request22 D4 A0
  • Service 22DID D4A0
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Coolant temperature 508_ECT_6A8

Pelican can show this parameter as the engine coolant temperature.

  • Request22 D4 15
  • Service 22DID D415
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Coolant temperature target 508_ECT_TGT

  • Request22 D4 0D
  • Service 22DID D40D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Coolant temperature, corrected 508_ECT_CORRECTED

  • Request22 D4 0A
  • Service 22DID D40A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Cruise control, RW status 508_CRUISE_CTRL_RW_STAT

  • Request22 D4 B0
  • Service 22DID D4B0
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Cylinder 1 injector flow correction 508_CYL_1_INJ_FLOW_CORR

  • Request22 D5 46
  • Service 22DID D546
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Cylinder 2 injector flow correction 508_CYL_2_INJ_FLOW_CORR

  • Request22 D5 47
  • Service 22DID D547
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Cylinder 3 injector flow correction 508_CYL_3_INJ_FLOW_CORR

  • Request22 D5 48
  • Service 22DID D548
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Cylinder 4 injector flow correction 508_CYL_4_INJ_FLOW_CORR

  • Request22 D5 49
  • Service 22DID D549
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Date 508_DATE

  • Request22 D4 CA
  • Service 22DID D4CA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729 s
Unit
s

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Diesel particulate filter differential pressure sensor signal deviation from reference value 508_DPF_DIFF_P_SENS_SIG

  • Request22 D5 18
  • Service 22DID D518
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Diesel particulate filter regeneration status 508_DPF_REGEN_STAT

  • Request22 D5 21
  • Service 22DID D521
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Driver presence 508_DRIVER_PRESENCE

  • Request22 D7 23
  • Service 22DID D723
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Driver, requested torque value 508_DRIVER_REQ_TQ

  • Request22 D5 07
  • Service 22DID D507
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 100)
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Economy mode off state 508_ECO_MODE_OFF_ST

  • Request22 D7 24
  • Service 22DID D724
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

EGR error EGR_ERRSAE J1979Confirmed

  • Request01 2D
  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2019.

Electric cooling fan control 508_GMV_ELEC_COOLING_FAN

  • Request22 D4 2F
  • Service 22DID D42F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Energy accumulator state transfer 508_ENERGY_ACCUMULATOR_ST

  • Request22 D7 55
  • Service 22DID D755
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Energy accumulator temperature limiter state 508_ENERGY_ACCUMULATOR_T

  • Request22 D7 58
  • Service 22DID D758
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine control module status 508_ENG_CTRL_MODULE_STAT

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine coolant temperature 508_ECT_6A9

  • Request22 D5 55
  • Service 22DID D555
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2014, 2019, 2021. Supported for 2012, 2015.

Engine oil dilution protection status 508_ENG_OIL_DILUTION

  • Request22 D5 24
  • Service 22DID D524
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine operating mode 508_ENG_OP_MODE

  • Request22 D5 53
  • Service 22DID D553
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8)
Range
0 to 8191 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine restart counter 508_ENG_RESTART_CNT

  • Request22 D4 06
  • Service 22DID D406
  • Module6A9 → 689
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine restart counter by stop and start function 508_ENG_RESTART_CNT_STOP

  • Request22 D7 1B
  • Service 22DID D71B
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine restart request sent by ESP computer 508_ENG_RESTART_REQ_SENT

  • Request22 D7 0D
  • Service 22DID D70D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2014, 2019, 2021. Supported for 2012, 2015.

Engine stalls 508_ENG_STALLS

  • Request22 D7 30
  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine start prohibition control, start lock 508_ENG_START

  • Request22 D7 03
  • Service 22DID D703
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine stop time 508_ENG_STOP_TIME

  • Request22 D4 77
  • Service 22DID D477
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 s
Unit
s

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine torque 508_ENG_TQ

  • Request21 C3
  • Service 21PID C3
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 2 − 100)
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Estimated torque of internal friction of the engine 508_ESTIMATED_TQ

  • Request22 D4 E2
  • Service 22DID D4E2
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Evaluation of carbon content in engine oil 508_EVALUATION_CARBON

  • Request22 D5 23
  • Service 22DID D523
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 32)
Range
0 to 7.96 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Evaluation of the degree of dilution of motor oil 508_EVALUATION_DEGREE

  • Request22 D5 1F
  • Service 22DID D51F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Evaluation of the exhaust gas flow using the nox sensor 508_EVALUATION_EXH_GAS

  • Request22 D5 42
  • Service 22DID D542
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val × 100)
Range
-214748364800 to 214748364700 L
Unit
L

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Exhaust gas flow through the particulate filter 508_EXH_GAS_FLOW_THROUGH

  • Request22 D5 33
  • Service 22DID D533
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 219.726593)
Range
0 to 14399782 L
Unit
L

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Exhaust gas pressure at the outlet of the particulate filter 508_EXH_GAS_P_OUTLET_PF

  • Request22 D5 44
  • Service 22DID D544
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 999.9999525)
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Exhaust gas recirculation high limit electronic loading 508_EGR_HIGH_LIM

  • Request22 D5 53
  • Service 22DID D553
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Exhaust gas recirculation low limit electronic loading 508_EGR_LOW_LIM

  • Request22 D5 52
  • Service 22DID D552
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Exhaust gas recirculation valve duty cycle 508_EGR_VLV_CTRL_SIG_RCO

  • Request22 D5 11
  • Service 22DID D511
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Exhaust gas recirculation valve first electronic loading 508_EGR_VLV_FIRST

  • Request22 D5 3A
  • Service 22DID D53A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Exhaust gas recirculation valve position 508_EGR_VLV_POS

  • Request22 D5 09
  • Service 22DID D509
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Exhaust gas recirculation valve set position 508_EGR_VLV_SET_POS

  • Request22 D5 10
  • Service 22DID D510
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Expected generator supplier identifier of the reversible generator 508_EXPECTED_GEN

  • Request22 D7 89
  • Service 22DID D789
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Expected identifier of electronic power circuit of reversible generator generator 508_EXPECTED_IDENTIFIER_ELECTRONIC

  • Request22 D7 88
  • Service 22DID D788
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Expected identifier of reversible generator 508_EXPECTED_IDENTIFIER

  • Request22 D7 87
  • Service 22DID D787
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Request01 23
  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2014, 2019. Supported for 2012, 2015, 2021.

FUGITIVE TRIP IN EMERGENCY MODE 508_FUGITIVE_TRIP

  • Request22 D6 71
  • Service 22DID D671
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Generator mode 508_GEN_MODE

  • Request22 D7 14
  • Service 22DID D714
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 75)
Range
0 to 19125 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Generator shutdown 508_GEN_SHUTDOWN

  • Request22 D7 5B
  • Service 22DID D75B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Glow plug plug set temperature 508_PREHEATING_T

  • Request22 D5 0F
  • Service 22DID D50F
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Glow plug relay status 508_STAT_PRE_POST

  • Request22 D5 0D
  • Service 22DID D50D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Identifier of the electronic power circuit of the reversible generator 508_IDENTIFIER

  • Request22 D7 32
  • Service 22DID D732
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Identifier of the supplier of the reversible generator 508_IDENTIFIER_SUPPLIER

  • Request22 D7 33
  • Service 22DID D733
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Immobilizer code programming status 508_IMMOBILIZER_CODE

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Indicated engine torque 508_INDICATED_ENG_TQ

  • Request22 D4 D2
  • Service 22DID D4D2
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Injector code 1 508_INJ_CODE_1

  • Request22 D5 00
  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 8 to 47 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Injector code 2 508_INJ_CODE_2

  • Request22 D5 00
  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 72 to 111 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Injector code 3 508_INJ_CODE_3

  • Request22 D5 00
  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 136 to 175 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Injector code 4 508_INJ_CODE_4

  • Request22 D5 00
  • Service 22DID D500
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 200 to 239 of the reply, 40 bits.

Formula
val
Range
0 to 1099511627775
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2014, 2019, 2021. Supported for 2012, 2015.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Request01 0B
  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2014, 2019. Supported for 2012, 2015, 2021.

Line pressure solenoid valve control current 508_SLT_LINE_P_VARIATION

  • Request22 D6 06
  • Service 22DID D606
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Lock status 508_LOCK_STAT

  • Request22 DA DD
  • Service 22DID DADD
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Long-term regeneration capability 508_LONG_TERM_REGEN

  • Request22 D5 4D
  • Service 22DID D54D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Mass of urea injected for thermal protection of urea injector 508_MASS_UREA_INJECTED

  • Request22 D5 6B
  • Service 22DID D56B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50.00000112)
Range
0 to 1310 g
Unit
g

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Maximum allowable torque 508_MAX_ALLOWABLE_TQ

  • Request22 D5 06
  • Service 22DID D506
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 100)
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of electromagnetic valve for changing the pressure in the brake system B2 508_MEAS_CURRENT_P_B2

  • Request22 D6 23
  • Service 22DID D623
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the electromagnetic valve for changing the pressure in the brake system B1 508_MEAS_CURRENT_P_B1

  • Request22 D6 09
  • Service 22DID D609
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured line pressure variation solenoid valve current 508_MEAS_LINE_P

  • Request22 D6 07
  • Service 22DID D607
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Mileage remaining before diesel particulate filter replacement 508_MILEAGE_REMAINING

  • Request22 D5 30
  • Service 22DID D530
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 16)
Range
-524288 to 524272 km
Unit
km

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Mileage since last diesel particulate filter replacement 508_MILEAGE_SINCE_DPF

  • Request22 D5 31
  • Service 22DID D531
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 8)
Range
0 to 524280 km
Unit
km

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Mileage since last oil change 508_MILEAGE_SINCE_OIL

  • Request22 D4 3F
  • Service 22DID D43F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 km
Unit
km

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Mixture enrichment measured by nox sensor at inlet 508_MIXTURE_ENRICHMENT

  • Request22 D5 71
  • Service 22DID D571
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Mixture enrichment measured by nox sensor at outlet 508_MIXTURE_ENRICHMENT_MEAS

  • Request22 D5 5B
  • Service 22DID D55B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Movement of controlled air supply module 508_MOVEMENT_CONTROLLED

  • Request22 D4 EB
  • Service 22DID D4EB
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Neutral position sensor status 508_NEUTRAL_POS_SENS

  • Request22 D4 38
  • Service 22DID D438
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Nox sensor heating control 508_NOX_SENS_HEATING

  • Request22 D5 54
  • Service 22DID D554
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Nox sensor signal status at the inlet 508_NOX_SENS_SIG_STAT_INLET

  • Request22 D5 72
  • Service 22DID D572
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Nox sensor signal status at the outlet 508_NOX_SENS_SIG_STAT

  • Request22 D5 73
  • Service 22DID D573
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Nox system operating status 508_NOX_SYSTEM_OP_STAT

  • Request22 D5 40
  • Service 22DID D540
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of engine stop information deletion cycles 508_NUM_ENG_STOP

  • Request22 D7 30
  • Service 22DID D730
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Oil pressure 508_OIL_P

  • Request22 D4 29
  • Service 22DID D429
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 bar
Unit
bar

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Oil pressure reference value 508_OIL_P_REFERENCE

  • Request22 D4 64
  • Service 22DID D464
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.53 bar
Unit
bar

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Oil pressure regulation control 508_OIL_P_REGULATION

  • Request22 D4 3B
  • Service 22DID D43B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Oil temperature 508_OIL_T

Pelican can show this parameter as the engine oil temperature.

  • Request22 D4 7D
  • Service 22DID D47D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Open loop soot load assessment of the diesel particulate filter 508_OPEN_LOOP_SOOT_LOAD

  • Request22 D5 4A
  • Service 22DID D54A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1024)
Range
0 to 63.99 g/L
Unit
g/L

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Outside air temperature 508_AAT_6A8

  • Request22 D4 14
  • Service 22DID D414
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Particulate filter differential pressure 508_PF_DIFF_P

  • Request22 D5 20
  • Service 22DID D520
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Power consumed for heating the pipelines of the urea injection system 508_POWER_CONSUMED

  • Request22 D5 80
  • Service 22DID D580
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Power spent on heating the urea injection system pipes, percentage ratio 508_POWER_SPENT_ON

  • Request22 D5 3C
  • Service 22DID D53C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 163.8399875)
Range
0 to 399 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Powertrain condition 508_POWERTRAIN_COND

  • Request22 D4 BA
  • Service 22DID D4BA
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Preheating relay control 508_PREHEATING_RELAY

  • Request22 D5 0C
  • Service 22DID D50C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Presence of the identifier of the reversible generator 508_PRESENCE_IDENTIFIER

  • Request22 D7 31
  • Service 22DID D731
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Pressure-based injection permission for urea solution 508_P_BASED_INJ

  • Request22 D5 14
  • Service 22DID D514
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Problems detected while transmitting unlock code 508_PROBLEMS_DETECTED

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Problems detected while transmitting unlock code 508_PROBLEMS_DETECTED_WHILE

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Real engine torque 508_REAL_ENG_TQ

  • Request22 D5 54
  • Service 22DID D554
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 100)
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Regeneration enable 508_REGEN_ENABLE

  • Request22 D5 28
  • Service 22DID D528
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Remaining urea solution in the urea tank 508_REMAINING_UREA

  • Request22 D5 17
  • Service 22DID D517
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 125 ÷ 128)
Range
0 to 63999
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Remote wake-up circuit status 508_REMOTE_WAKE_UP

  • Request22 D7 05
  • Service 22DID D705
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Remote wake-up state 508_REMOTE_WAKE_UP_ST

  • Request22 D7 08
  • Service 22DID D708
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Request to turn on the engine diagnostic indicator 508_REQ_TURN_ON_ENG

  • Request22 D5 11
  • Service 22DID D511
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Requested value controlled thermostat 508_REQ_CONTROLLED

  • Request22 D5 86
  • Service 22DID D586
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 81.92000625)
Range
-399 to 399 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Restart request sent by power steering computer 508_RESTART_REQ_SENT

  • Request22 D7 0C
  • Service 22DID D70C
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Restart request sent by suspension computer 508_RESTART_REQ_SENT_SUSPENSION

  • Request22 D7 0E
  • Service 22DID D70E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Return to engine start and restart control by starter 508_RETURN_ENG_START

  • Request22 D7 64
  • Service 22DID D764
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Return to starter engine restart control 508_RETURN_STARTER_ENG

  • Request22 D7 61
  • Service 22DID D761
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Reverse generator status 508_REVERSE_GEN_STAT

  • Request22 D7 16
  • Service 22DID D716
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Reversible generator torque 508_REVERSIBLE_GEN_TQ

  • Request22 D7 15
  • Service 22DID D715
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Service network related engine restart request 508_SERVICE_NETWORK

  • Request22 D7 4B
  • Service 22DID D74B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2021.

Short-term regeneration capability 508_SHORT_TERM_REGEN

  • Request22 D5 4C
  • Service 22DID D54C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Soot clogging level of diesel particulate filter 508_SOOT_CLOGGING_LEVEL

  • Request22 D5 2F
  • Service 22DID D52F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10.24)
Range
0 to 6399 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Specified volume of injected urea solution 508_SPEC_VOLUME_INJECTED

  • Request22 D5 50
  • Service 22DID D550
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Sport mode contactor state 508_SPORT_MODE_CONTACTOR

  • Request22 D5 03
  • Service 22DID D503
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Start inhibit control, wired 508_START_INHIBIT_CTRL

  • Request22 D7 67
  • Service 22DID D767
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Start or restart inhibition transmitted by engine management computer 508_START_OR_RESTART

  • Request22 D7 1E
  • Service 22DID D71E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Start prohibition 508_START_PROHIBITION

  • Request22 D5 1B
  • Service 22DID D51B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Starter activation counter 508_STARTER_ACTIVATION

  • Request22 D7 1F
  • Service 22DID D71F
  • Module6A8 → 688
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Starter control interface unit operating status 508_STARTER_CTRL

  • Request22 D7 2A
  • Service 22DID D72A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Starter duty cycle 508_STARTER_DUTY

  • Request22 D4 78
  • Service 22DID D478
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 s
Unit
s

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Starter engagement status 508_STARTER_ENGAGEMENT

  • Request22 D4 C3
  • Service 22DID D4C3
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

State lock/unlock control unit 508_ST_LOCK_UNLOCK_CTRL

  • Request22 DA DC
  • Service 22DID DADC
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Status of internal ignition motor 508_STAT_INTERNAL_IGN

  • Request22 D4 12
  • Service 22DID D412
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Status of the energy accumulator 508_STAT_ENERGY

  • Request22 D7 22
  • Service 22DID D722
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Stop allowed by ESP computer 508_STOP_ALLOWED_ESP

  • Request22 D7 06
  • Service 22DID D706
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Stop and start function state 508_STOP_START_FUNCTION

  • Request22 D7 25
  • Service 22DID D725
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Stop and start switch 508_STOP_START_SWITCH

  • Request22 D7 26
  • Service 22DID D726
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Stop permitted by suspension computer 508_STOP_PERMITTED

  • Request22 D7 07
  • Service 22DID D707
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Temperature of the energy accumulator 508_T_ENERGY_ACCUMULATOR

  • Request22 D7 21
  • Service 22DID D721
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Temperature of the urea solution in the urea tank 508_T_UREA_SOLUTION_UREA

  • Request22 D5 6D
  • Service 22DID D56D
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

The composition of the mixture is calculated by the oxygen sensor 508_COMPOSITION_MIXTURE

  • Request22 D5 70
  • Service 22DID D570
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32786.88588)
Range
0 to 1.99
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Request01 0E
  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2021.

Torque corresponding to driver requirement 508_TQ_CORRESPONDING

  • Request22 D4 E3
  • Service 22DID D4E3
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Torque supplied or taken by generator 508_TQ_SUPPLIED_OR_TAKEN

  • Request22 D7 28
  • Service 22DID D728
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Total mass of additive accumulated in the diesel particulate filter 508_TOT_MASS_ADDITIVE

  • Request22 D5 26
  • Service 22DID D526
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
0 to 511 g
Unit
g

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Total mass of additive accumulated in the diesel particulate filter 508_TOT_MASS_ADDITIVE_ACCUMULATED_DPF

  • Request22 D5 27
  • Service 22DID D527
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047 g
Unit
g

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Total mileage 508_ODO_6A8

Pelican can show this parameter as the odometer.

  • Request22 D4 9C
  • Service 22DID D49C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Towing device configured 508_CAN_VEH_BE_EQUIPPED

  • Request22 D5 57
  • Service 22DID D557
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Traction or stability control regulating 508_ASR_OR_ESP_SYSTEM

  • Request22 D5 12
  • Service 22DID D512
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Transmission fluid temperature 508_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request21 C5
  • Service 21PID C5
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val − 50)
Range
-50 to 205 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Request01 51
  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2019.

Urea mass fraction 508_UREA_MASS_FRACTION

  • Request22 D5 8C
  • Service 22DID D58C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Urea solution injected amount 508_UREA_SOLUTION

  • Request22 D5 68
  • Service 22DID D568
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Urea solution injection permission based on temperature value 508_UREA_SOLUTION_INJ_ON_T

  • Request22 D5 15
  • Service 22DID D515
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Urea solution pressure 508_UREA_SOLUTION_P

  • Request22 D5 3E
  • Service 22DID D53E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 bar
Unit
bar

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Urea solution type in urea tank 508_UREA_SOLUTION_TYPE

  • Request22 D5 8D
  • Service 22DID D58D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Urea tank heating current 508_UREA_TANK_HEATING

  • Request22 D5 81
  • Service 22DID D581
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Urea tank heating current, percentage 508_UREA_TANK_HEATING_CURRENT

  • Request22 D5 1E
  • Service 22DID D51E
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 163.8399875)
Range
0 to 399 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Vacuum circuit vacuum 508_VACUUM_CIRCUIT

  • Request22 D7 3B
  • Service 22DID D73B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Value during generator load smooth increase 508_DURING_GEN_LOAD

  • Request22 D7 53
  • Service 22DID D753
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Vehicle hour meter 508_VEH_HOUR_METER

  • Request22 D8 01
  • Service 22DID D801
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729 s
Unit
s

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Vehicle mileage remaining before filling the tank with urea solution 508_VEH_MILEAGE

  • Request22 D5 13
  • Service 22DID D513
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 50)
Range
0 to 12750 km
Unit
km

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Vehicle mileage since the last oil change under severe vehicle operating conditions 508_VEH_MILEAGE_SINCE

  • Request22 D5 34
  • Service 22DID D534
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 km
Unit
km

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Volume of urea solution measured in urea tank 508_VOLUME_UREA_SOLUTION

  • Request22 D5 58
  • Service 22DID D558
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 L
Unit
L

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Wastegate A position WG_A_ACTSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2019.

Wastegate B position WG_B_ACTSAE J1979Confirmed

If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2019.

Water in diesel 508_WATER_DIESEL

  • Request22 D5 2C
  • Service 22DID D52C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Winter mode switch state 508_WINTER_MODE_SWITCH

  • Request22 D5 02
  • Service 22DID D502
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine › Internal

Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed

  • Request01 4F
  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.

Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed

  • Request01 4F
  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 kPa
Unit
kPa

Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.

Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed

  • Request01 4F
  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.

Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed

  • Request01 4F
  • Service 01PID 4F
  • Module7E0 → 7E8
  • Every3600 s

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 V
Unit
V

Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.

Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed

  • Request01 72
  • Service 01PID 72
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019.

Engine › OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2014, 2021. Supported for 2012, 2015, 2019.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2014. Supported for 2012, 2015.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2014, 2021. Supported for 2012, 2015, 2019.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 8196)
Range
0 to 7.999 V
Unit
V

Confirmed for 2014. Supported for 2012, 2015.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.