Engine parameters
The Peugeot 508 has 234 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
5V power supply state number 1 508_5V_POWER_SUP_ST_1
- Request
22 D4 23 - Service 22
DID D423 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
5V power supply state number 2 508_5V_POWER_SUP_ST_2
- Request
22 D4 24 - Service 22
DID D424 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
5V power supply state number 3 508_5V_POWER_SUP_ST_3
- Request
22 D4 25 - Service 22
DID D425 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
5V power supply state number 4 508_5V_POWER_SUP_ST_4
- Request
22 D4 26 - Service 22
DID D426 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
12V network allowed stop 508_12V_NETWORK_ALLOWED
- Request
22 D7 4C - Service 22
DID D74C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, brake electromagnetic valve B1 508_NUM_ACTIVATIONS_B1
- Request
22 D7 45 - Service 22
DID D745 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, line pressure control solenoid 508_NUM_LINE_P_CTRL
- Request
22 D7 51 - Service 22
DID D751 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Activation count, the electromagnetic valve of brake B2 508_NUM_ACTIVATIONS_B2
- Request
22 D7 5A - Service 22
DID D75A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Actual oil pressure 508_ACT_OIL_P
- Request
21 C5 - Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 20)- Range
- 0 to 12.75 bar
- Unit
- bar
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Additional heater control 1 508_ADDITIONAL_HEATER_1
- Request
22 D4 16 - Service 22
DID D416 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Air conditioning 508_AC
- Request
22 D4 AF - Service 22
DID D4AF - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Air conditioning compressor current 508_AC_COMP_CURRENT
- Request
22 D4 1C - Service 22
DID D41C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Air conditioning pressure 508_AC_P
- Request
22 D4 21 - Service 22
DID D421 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Air doser first electronic loading 508_AIR_DOSER_FIRST
- Request
22 D5 3B - Service 22
DID D53B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Air flow 508_AIR_FLOW
- Request
22 D4 89 - Service 22
DID D489 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2014, 2019, 2021. Supported for 2012, 2015.
Air flow target 508_AIR_FLOW_TGT
- Request
22 D4 8E - Service 22
DID D48E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Air metering valve duty cycle 508_AIR_METERING_VLV
- Request
22 D4 61 - Service 22
DID D461 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Air metering valve position 508_AIR_METERING_VLV_POS
- Request
22 D5 4F - Service 22
DID D54F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Air metering valve, target position 508_AIR_METERING_VLV_TGT
- Request
22 D4 60 - Service 22
DID D460 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Air temperature by air flow meter 508_AIR_T_AIR_FLOW_METER
- Request
22 D5 4E - Service 22
DID D54E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Alternator load value 508_ALTERNATOR_LOAD
- Request
22 D4 A5 - Service 22
DID D4A5 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Ambient air temperature 508_AAT_6A9
- Request
22 D5 52 - Service 22
DID D552 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
ANTI START PROGRAMMING STATUS 508_ANTI_START
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Assessment of thermal aging of the particulate filter 508_ASSESSMENT_THERMAL
- Request
22 D5 32 - Service 22
DID D532 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 25 ÷ 128)- Range
- 0 to 12799 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Atmospheric pressure 508_ATMOSPHERIC_P
- Request
22 D4 65 - Service 22
DID D465 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic restart request from body control module 508_AUTOMATIC_RESTART_REQ_BSI
- Request
22 D7 0A - Service 22
DID D70A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic restart request from engine management computer 508_AUTOMATIC_RESTART
- Request
22 D7 09 - Service 22
DID D709 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic stop allowed by body control module 508_AUTOMATIC_STOP
- Request
22 D7 03 - Service 22
DID D703 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Automatic stop allowed by power steering computer 508_AUTOMATIC_STOP_ALLOWED_POWER_STEER
- Request
22 D7 05 - Service 22
DID D705 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Auxiliary heater 2 control 508_AUXILIARY_HEATER_2
- Request
22 D4 17 - Service 22
DID D417 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Average mileage for the last 10 regenerations 508_AVG_MILEAGE_LAST_10
- Request
22 D5 25 - Service 22
DID D525 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 16)- Range
- 0 to 4095 km
- Unit
- km
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2014, 2019. Supported for 2012, 2015, 2021.
Boost air temperature 508_BOOST_AIR_T
- Request
22 D4 11 - Service 22
DID D411 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Button state 508_BUTTON_ST
- Request
22 D5 17 - Service 22
DID D517 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2014, 2019, 2021. Supported for 2012, 2015.
Camshaft/crankshaft position synchronization 508_CAM_CRANK_POS
- Request
22 D4 18 - Service 22
DID D418 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2019. Supported for 2021.
CHANGE REPORT IN PROGRESS 508_CHANGE_REPORT
- Request
22 D5 16 - Service 22
DID D516 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Closed loop soot load assessment of the diesel particulate filter 508_CLOSED_LOOP_SOOT
- Request
22 D5 4B - Service 22
DID D54B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.99 g/L
- Unit
- g/L
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Combustion engine state 508_ICE_ST
- Request
22 D7 09 - Service 22
DID D709 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Request
01 2C - Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2021.
Commanded oil pressure 508_CMD_OIL_P
- Request
21 C5 - Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 bar
- Unit
- bar
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019. Supported for 2021.
Commanded wastegate A position WG_A_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Commanded wastegate B position WG_B_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Computer lock 508_COMPUTER_LOCK
- Request
22 DA DD - Service 22
DID DADD - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Computer remote wake-up state 508_COMPUTER_WAKE_UP_ST
- Request
22 D5 15 - Service 22
DID D515 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Computer restarts since memory erase 508_CNT_NUM_RE
- Request
22 D4 D8 - Service 22
DID D4D8 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Computer temperature 508_COMPUTER_T
- Request
22 D4 35 - Service 22
DID D435 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Control current of electromagnetic valve for changing the pressure in the brake system B2 508_CTRL_CURRENT_P_B2
- Request
22 D6 22 - Service 22
DID D622 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Control current of the electromagnetic valve for changing the pressure in the brake system B1 508_CTRL_CURRENT_P_B1
- Request
22 D6 08 - Service 22
DID D608 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Controlled air supply module 508_CONTROLLED_AIR_SUP
- Request
22 D4 A0 - Service 22
DID D4A0 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Coolant temperature 508_ECT_6A8
Pelican can show this parameter as the engine coolant temperature.
- Request
22 D4 15 - Service 22
DID D415 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Coolant temperature target 508_ECT_TGT
- Request
22 D4 0D - Service 22
DID D40D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Coolant temperature, corrected 508_ECT_CORRECTED
- Request
22 D4 0A - Service 22
DID D40A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Cruise control, RW status 508_CRUISE_CTRL_RW_STAT
- Request
22 D4 B0 - Service 22
DID D4B0 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Cylinder 1 injector flow correction 508_CYL_1_INJ_FLOW_CORR
- Request
22 D5 46 - Service 22
DID D546 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Cylinder 2 injector flow correction 508_CYL_2_INJ_FLOW_CORR
- Request
22 D5 47 - Service 22
DID D547 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Cylinder 3 injector flow correction 508_CYL_3_INJ_FLOW_CORR
- Request
22 D5 48 - Service 22
DID D548 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Cylinder 4 injector flow correction 508_CYL_4_INJ_FLOW_CORR
- Request
22 D5 49 - Service 22
DID D549 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Date 508_DATE
- Request
22 D4 CA - Service 22
DID D4CA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 s
- Unit
- s
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Diesel particulate filter differential pressure sensor signal deviation from reference value 508_DPF_DIFF_P_SENS_SIG
- Request
22 D5 18 - Service 22
DID D518 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Diesel particulate filter regeneration status 508_DPF_REGEN_STAT
- Request
22 D5 21 - Service 22
DID D521 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Driver presence 508_DRIVER_PRESENCE
- Request
22 D7 23 - Service 22
DID D723 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Driver, requested torque value 508_DRIVER_REQ_TQ
- Request
22 D5 07 - Service 22
DID D507 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Economy mode off state 508_ECO_MODE_OFF_ST
- Request
22 D7 24 - Service 22
DID D724 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
EGR error EGR_ERRSAE J1979Confirmed
- Request
01 2D - Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2019.
Electric cooling fan control 508_GMV_ELEC_COOLING_FAN
- Request
22 D4 2F - Service 22
DID D42F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Energy accumulator state transfer 508_ENERGY_ACCUMULATOR_ST
- Request
22 D7 55 - Service 22
DID D755 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Energy accumulator temperature limiter state 508_ENERGY_ACCUMULATOR_T
- Request
22 D7 58 - Service 22
DID D758 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine control module status 508_ENG_CTRL_MODULE_STAT
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine coolant temperature 508_ECT_6A9
- Request
22 D5 55 - Service 22
DID D555 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2014, 2019, 2021. Supported for 2012, 2015.
Engine oil dilution protection status 508_ENG_OIL_DILUTION
- Request
22 D5 24 - Service 22
DID D524 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine operating mode 508_ENG_OP_MODE
- Request
22 D5 53 - Service 22
DID D553 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8)- Range
- 0 to 8191 rpm
- Unit
- rpm
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine restart counter 508_ENG_RESTART_CNT
- Request
22 D4 06 - Service 22
DID D406 - Module
6A9 → 689 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine restart counter by stop and start function 508_ENG_RESTART_CNT_STOP
- Request
22 D7 1B - Service 22
DID D71B - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine restart request sent by ESP computer 508_ENG_RESTART_REQ_SENT
- Request
22 D7 0D - Service 22
DID D70D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2014, 2019, 2021. Supported for 2012, 2015.
Engine stalls 508_ENG_STALLS
- Request
22 D7 30 - Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine start prohibition control, start lock 508_ENG_START
- Request
22 D7 03 - Service 22
DID D703 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine stop time 508_ENG_STOP_TIME
- Request
22 D4 77 - Service 22
DID D477 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 s
- Unit
- s
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine torque 508_ENG_TQ
- Request
21 C3 - Service 21
PID C3 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Estimated torque of internal friction of the engine 508_ESTIMATED_TQ
- Request
22 D4 E2 - Service 22
DID D4E2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Evaluation of carbon content in engine oil 508_EVALUATION_CARBON
- Request
22 D5 23 - Service 22
DID D523 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 32)- Range
- 0 to 7.96 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Evaluation of the degree of dilution of motor oil 508_EVALUATION_DEGREE
- Request
22 D5 1F - Service 22
DID D51F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Evaluation of the exhaust gas flow using the nox sensor 508_EVALUATION_EXH_GAS
- Request
22 D5 42 - Service 22
DID D542 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val × 100)- Range
- -214748364800 to 214748364700 L
- Unit
- L
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Exhaust gas flow through the particulate filter 508_EXH_GAS_FLOW_THROUGH
- Request
22 D5 33 - Service 22
DID D533 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 219.726593)- Range
- 0 to 14399782 L
- Unit
- L
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Exhaust gas pressure at the outlet of the particulate filter 508_EXH_GAS_P_OUTLET_PF
- Request
22 D5 44 - Service 22
DID D544 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 999.9999525)- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Exhaust gas recirculation high limit electronic loading 508_EGR_HIGH_LIM
- Request
22 D5 53 - Service 22
DID D553 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Exhaust gas recirculation low limit electronic loading 508_EGR_LOW_LIM
- Request
22 D5 52 - Service 22
DID D552 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Exhaust gas recirculation valve duty cycle 508_EGR_VLV_CTRL_SIG_RCO
- Request
22 D5 11 - Service 22
DID D511 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Exhaust gas recirculation valve first electronic loading 508_EGR_VLV_FIRST
- Request
22 D5 3A - Service 22
DID D53A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Exhaust gas recirculation valve position 508_EGR_VLV_POS
- Request
22 D5 09 - Service 22
DID D509 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Exhaust gas recirculation valve set position 508_EGR_VLV_SET_POS
- Request
22 D5 10 - Service 22
DID D510 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Expected generator supplier identifier of the reversible generator 508_EXPECTED_GEN
- Request
22 D7 89 - Service 22
DID D789 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Expected identifier of electronic power circuit of reversible generator generator 508_EXPECTED_IDENTIFIER_ELECTRONIC
- Request
22 D7 88 - Service 22
DID D788 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Expected identifier of reversible generator 508_EXPECTED_IDENTIFIER
- Request
22 D7 87 - Service 22
DID D787 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Fuel rail pressure FRPSAE J1979Confirmed
Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).
- Request
01 23 - Service 01
PID 23 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2014, 2019. Supported for 2012, 2015, 2021.
FUGITIVE TRIP IN EMERGENCY MODE 508_FUGITIVE_TRIP
- Request
22 D6 71 - Service 22
DID D671 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Generator mode 508_GEN_MODE
- Request
22 D7 14 - Service 22
DID D714 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 75)- Range
- 0 to 19125 rpm
- Unit
- rpm
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Generator shutdown 508_GEN_SHUTDOWN
- Request
22 D7 5B - Service 22
DID D75B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Glow plug plug set temperature 508_PREHEATING_T
- Request
22 D5 0F - Service 22
DID D50F - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Glow plug relay status 508_STAT_PRE_POST
- Request
22 D5 0D - Service 22
DID D50D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Identifier of the electronic power circuit of the reversible generator 508_IDENTIFIER
- Request
22 D7 32 - Service 22
DID D732 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Identifier of the supplier of the reversible generator 508_IDENTIFIER_SUPPLIER
- Request
22 D7 33 - Service 22
DID D733 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Immobilizer code programming status 508_IMMOBILIZER_CODE
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Indicated engine torque 508_INDICATED_ENG_TQ
- Request
22 D4 D2 - Service 22
DID D4D2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Injector code 1 508_INJ_CODE_1
- Request
22 D5 00 - Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 47 of the reply, 40 bits.
- Formula
val- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Injector code 2 508_INJ_CODE_2
- Request
22 D5 00 - Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 72 to 111 of the reply, 40 bits.
- Formula
val- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Injector code 3 508_INJ_CODE_3
- Request
22 D5 00 - Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 136 to 175 of the reply, 40 bits.
- Formula
val- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Injector code 4 508_INJ_CODE_4
- Request
22 D5 00 - Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 200 to 239 of the reply, 40 bits.
- Formula
val- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2014, 2019, 2021. Supported for 2012, 2015.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2014, 2019. Supported for 2012, 2015, 2021.
Line pressure solenoid valve control current 508_SLT_LINE_P_VARIATION
- Request
22 D6 06 - Service 22
DID D606 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Lock status 508_LOCK_STAT
- Request
22 DA DD - Service 22
DID DADD - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Long-term regeneration capability 508_LONG_TERM_REGEN
- Request
22 D5 4D - Service 22
DID D54D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Mass of urea injected for thermal protection of urea injector 508_MASS_UREA_INJECTED
- Request
22 D5 6B - Service 22
DID D56B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50.00000112)- Range
- 0 to 1310 g
- Unit
- g
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Maximum allowable torque 508_MAX_ALLOWABLE_TQ
- Request
22 D5 06 - Service 22
DID D506 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured current of electromagnetic valve for changing the pressure in the brake system B2 508_MEAS_CURRENT_P_B2
- Request
22 D6 23 - Service 22
DID D623 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured current of the electromagnetic valve for changing the pressure in the brake system B1 508_MEAS_CURRENT_P_B1
- Request
22 D6 09 - Service 22
DID D609 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Measured line pressure variation solenoid valve current 508_MEAS_LINE_P
- Request
22 D6 07 - Service 22
DID D607 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Mileage remaining before diesel particulate filter replacement 508_MILEAGE_REMAINING
- Request
22 D5 30 - Service 22
DID D530 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 16)- Range
- -524288 to 524272 km
- Unit
- km
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Mileage since last diesel particulate filter replacement 508_MILEAGE_SINCE_DPF
- Request
22 D5 31 - Service 22
DID D531 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8)- Range
- 0 to 524280 km
- Unit
- km
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Mileage since last oil change 508_MILEAGE_SINCE_OIL
- Request
22 D4 3F - Service 22
DID D43F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Mixture enrichment measured by nox sensor at inlet 508_MIXTURE_ENRICHMENT
- Request
22 D5 71 - Service 22
DID D571 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Mixture enrichment measured by nox sensor at outlet 508_MIXTURE_ENRICHMENT_MEAS
- Request
22 D5 5B - Service 22
DID D55B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Movement of controlled air supply module 508_MOVEMENT_CONTROLLED
- Request
22 D4 EB - Service 22
DID D4EB - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Neutral position sensor status 508_NEUTRAL_POS_SENS
- Request
22 D4 38 - Service 22
DID D438 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Nox sensor heating control 508_NOX_SENS_HEATING
- Request
22 D5 54 - Service 22
DID D554 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Nox sensor signal status at the inlet 508_NOX_SENS_SIG_STAT_INLET
- Request
22 D5 72 - Service 22
DID D572 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Nox sensor signal status at the outlet 508_NOX_SENS_SIG_STAT
- Request
22 D5 73 - Service 22
DID D573 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Nox system operating status 508_NOX_SYSTEM_OP_STAT
- Request
22 D5 40 - Service 22
DID D540 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Number of engine stop information deletion cycles 508_NUM_ENG_STOP
- Request
22 D7 30 - Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Oil pressure 508_OIL_P
- Request
22 D4 29 - Service 22
DID D429 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Oil pressure reference value 508_OIL_P_REFERENCE
- Request
22 D4 64 - Service 22
DID D464 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Oil pressure regulation control 508_OIL_P_REGULATION
- Request
22 D4 3B - Service 22
DID D43B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Oil temperature 508_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Request
22 D4 7D - Service 22
DID D47D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Open loop soot load assessment of the diesel particulate filter 508_OPEN_LOOP_SOOT_LOAD
- Request
22 D5 4A - Service 22
DID D54A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1024)- Range
- 0 to 63.99 g/L
- Unit
- g/L
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Outside air temperature 508_AAT_6A8
- Request
22 D4 14 - Service 22
DID D414 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Particulate filter differential pressure 508_PF_DIFF_P
- Request
22 D5 20 - Service 22
DID D520 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Power consumed for heating the pipelines of the urea injection system 508_POWER_CONSUMED
- Request
22 D5 80 - Service 22
DID D580 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Power spent on heating the urea injection system pipes, percentage ratio 508_POWER_SPENT_ON
- Request
22 D5 3C - Service 22
DID D53C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 163.8399875)- Range
- 0 to 399 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Powertrain condition 508_POWERTRAIN_COND
- Request
22 D4 BA - Service 22
DID D4BA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Preheating relay control 508_PREHEATING_RELAY
- Request
22 D5 0C - Service 22
DID D50C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Presence of the identifier of the reversible generator 508_PRESENCE_IDENTIFIER
- Request
22 D7 31 - Service 22
DID D731 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Pressure-based injection permission for urea solution 508_P_BASED_INJ
- Request
22 D5 14 - Service 22
DID D514 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Problems detected while transmitting unlock code 508_PROBLEMS_DETECTED
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Problems detected while transmitting unlock code 508_PROBLEMS_DETECTED_WHILE
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Real engine torque 508_REAL_ENG_TQ
- Request
22 D5 54 - Service 22
DID D554 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Regeneration enable 508_REGEN_ENABLE
- Request
22 D5 28 - Service 22
DID D528 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Remaining urea solution in the urea tank 508_REMAINING_UREA
- Request
22 D5 17 - Service 22
DID D517 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 125 ÷ 128)- Range
- 0 to 63999
- Unit
- Raw value
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Remote wake-up circuit status 508_REMOTE_WAKE_UP
- Request
22 D7 05 - Service 22
DID D705 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Remote wake-up state 508_REMOTE_WAKE_UP_ST
- Request
22 D7 08 - Service 22
DID D708 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Request to turn on the engine diagnostic indicator 508_REQ_TURN_ON_ENG
- Request
22 D5 11 - Service 22
DID D511 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Requested value controlled thermostat 508_REQ_CONTROLLED
- Request
22 D5 86 - Service 22
DID D586 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 81.92000625)- Range
- -399 to 399 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Restart request sent by power steering computer 508_RESTART_REQ_SENT
- Request
22 D7 0C - Service 22
DID D70C - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Restart request sent by suspension computer 508_RESTART_REQ_SENT_SUSPENSION
- Request
22 D7 0E - Service 22
DID D70E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Return to engine start and restart control by starter 508_RETURN_ENG_START
- Request
22 D7 64 - Service 22
DID D764 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Return to starter engine restart control 508_RETURN_STARTER_ENG
- Request
22 D7 61 - Service 22
DID D761 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Reverse generator status 508_REVERSE_GEN_STAT
- Request
22 D7 16 - Service 22
DID D716 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Reversible generator torque 508_REVERSIBLE_GEN_TQ
- Request
22 D7 15 - Service 22
DID D715 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Service network related engine restart request 508_SERVICE_NETWORK
- Request
22 D7 4B - Service 22
DID D74B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2021.
Short-term regeneration capability 508_SHORT_TERM_REGEN
- Request
22 D5 4C - Service 22
DID D54C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Soot clogging level of diesel particulate filter 508_SOOT_CLOGGING_LEVEL
- Request
22 D5 2F - Service 22
DID D52F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10.24)- Range
- 0 to 6399 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Specified volume of injected urea solution 508_SPEC_VOLUME_INJECTED
- Request
22 D5 50 - Service 22
DID D550 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023
- Unit
- Raw value
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Sport mode contactor state 508_SPORT_MODE_CONTACTOR
- Request
22 D5 03 - Service 22
DID D503 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Start inhibit control, wired 508_START_INHIBIT_CTRL
- Request
22 D7 67 - Service 22
DID D767 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Start or restart inhibition transmitted by engine management computer 508_START_OR_RESTART
- Request
22 D7 1E - Service 22
DID D71E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Start prohibition 508_START_PROHIBITION
- Request
22 D5 1B - Service 22
DID D51B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Starter activation counter 508_STARTER_ACTIVATION
- Request
22 D7 1F - Service 22
DID D71F - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Starter control interface unit operating status 508_STARTER_CTRL
- Request
22 D7 2A - Service 22
DID D72A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Starter duty cycle 508_STARTER_DUTY
- Request
22 D4 78 - Service 22
DID D478 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 s
- Unit
- s
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Starter engagement status 508_STARTER_ENGAGEMENT
- Request
22 D4 C3 - Service 22
DID D4C3 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
State lock/unlock control unit 508_ST_LOCK_UNLOCK_CTRL
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Status of internal ignition motor 508_STAT_INTERNAL_IGN
- Request
22 D4 12 - Service 22
DID D412 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Status of the energy accumulator 508_STAT_ENERGY
- Request
22 D7 22 - Service 22
DID D722 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Stop allowed by ESP computer 508_STOP_ALLOWED_ESP
- Request
22 D7 06 - Service 22
DID D706 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Stop and start function state 508_STOP_START_FUNCTION
- Request
22 D7 25 - Service 22
DID D725 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Stop and start switch 508_STOP_START_SWITCH
- Request
22 D7 26 - Service 22
DID D726 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Stop permitted by suspension computer 508_STOP_PERMITTED
- Request
22 D7 07 - Service 22
DID D707 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Temperature of the energy accumulator 508_T_ENERGY_ACCUMULATOR
- Request
22 D7 21 - Service 22
DID D721 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Temperature of the urea solution in the urea tank 508_T_UREA_SOLUTION_UREA
- Request
22 D5 6D - Service 22
DID D56D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
The composition of the mixture is calculated by the oxygen sensor 508_COMPOSITION_MIXTURE
- Request
22 D5 70 - Service 22
DID D570 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2021.
Torque corresponding to driver requirement 508_TQ_CORRESPONDING
- Request
22 D4 E3 - Service 22
DID D4E3 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Torque supplied or taken by generator 508_TQ_SUPPLIED_OR_TAKEN
- Request
22 D7 28 - Service 22
DID D728 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Total mass of additive accumulated in the diesel particulate filter 508_TOT_MASS_ADDITIVE
- Request
22 D5 26 - Service 22
DID D526 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- 0 to 511 g
- Unit
- g
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Total mass of additive accumulated in the diesel particulate filter 508_TOT_MASS_ADDITIVE_ACCUMULATED_DPF
- Request
22 D5 27 - Service 22
DID D527 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047 g
- Unit
- g
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Total mileage 508_ODO_6A8
Pelican can show this parameter as the odometer.
- Request
22 D4 9C - Service 22
DID D49C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Towing device configured 508_CAN_VEH_BE_EQUIPPED
- Request
22 D5 57 - Service 22
DID D557 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Traction or stability control regulating 508_ASR_OR_ESP_SYSTEM
- Request
22 D5 12 - Service 22
DID D512 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Transmission fluid temperature 508_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 C5 - Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2019.
Urea mass fraction 508_UREA_MASS_FRACTION
- Request
22 D5 8C - Service 22
DID D58C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Urea solution injected amount 508_UREA_SOLUTION
- Request
22 D5 68 - Service 22
DID D568 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023
- Unit
- Raw value
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Urea solution injection permission based on temperature value 508_UREA_SOLUTION_INJ_ON_T
- Request
22 D5 15 - Service 22
DID D515 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Urea solution pressure 508_UREA_SOLUTION_P
- Request
22 D5 3E - Service 22
DID D53E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 bar
- Unit
- bar
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Urea solution type in urea tank 508_UREA_SOLUTION_TYPE
- Request
22 D5 8D - Service 22
DID D58D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Urea tank heating current 508_UREA_TANK_HEATING
- Request
22 D5 81 - Service 22
DID D581 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Urea tank heating current, percentage 508_UREA_TANK_HEATING_CURRENT
- Request
22 D5 1E - Service 22
DID D51E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 163.8399875)- Range
- 0 to 399 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Vacuum circuit vacuum 508_VACUUM_CIRCUIT
- Request
22 D7 3B - Service 22
DID D73B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Value during generator load smooth increase 508_DURING_GEN_LOAD
- Request
22 D7 53 - Service 22
DID D753 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Vehicle hour meter 508_VEH_HOUR_METER
- Request
22 D8 01 - Service 22
DID D801 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 s
- Unit
- s
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Vehicle mileage remaining before filling the tank with urea solution 508_VEH_MILEAGE
- Request
22 D5 13 - Service 22
DID D513 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 km
- Unit
- km
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Vehicle mileage since the last oil change under severe vehicle operating conditions 508_VEH_MILEAGE_SINCE
- Request
22 D5 34 - Service 22
DID D534 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 km
- Unit
- km
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Volume of urea solution measured in urea tank 508_VOLUME_UREA_SOLUTION
- Request
22 D5 58 - Service 22
DID D558 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 L
- Unit
- L
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Wastegate A position WG_A_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Wastegate B position WG_B_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2019.
Water in diesel 508_WATER_DIESEL
- Request
22 D5 2C - Service 22
DID D52C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Winter mode switch state 508_WINTER_MODE_SWITCH
- Request
22 D5 02 - Service 22
DID D502 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine › Internal
Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.
Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 kPa
- Unit
- kPa
Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.
Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.
Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.
Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2019.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2014. Supported for 2012, 2015, 2019, 2021.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2014, 2021. Supported for 2012, 2015, 2019.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2014. Supported for 2012, 2015.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2014, 2021. Supported for 2012, 2015, 2019.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 8196)- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2014. Supported for 2012, 2015.