Peugeot 508

Transmission parameters

The Peugeot 508 has 94 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Activation count, additional oil pump, ATN8 gearbox 508_NUM_ADDITIONAL_OIL

  • Request22 D7 50
  • Service 22DID D750
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Activation count, additional oil pump, ATN8 gearbox 508_NUM_ADDITIONAL_OIL

  • Request22 D7 50
  • Service 22DID D750
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, clutch electromagnetic valve C2 508_NUM_ACTIVATIONS_CLU_ELECTROMAGNETIC_VLV_C2

  • Request22 D7 43
  • Service 22DID D743
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, clutch electromagnetic valve C3 508_NUM_ACTIVATIONS_CLU_C3

  • Request22 D7 44
  • Service 22DID D744
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, clutch protection C1 508_NUM_ACTIVATIONS_CLU_C1

  • Request22 D7 31
  • Service 22DID D731
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, clutch protection C2 508_NUM_ACTIVATIONS_CLU_C2

  • Request22 D7 31
  • Service 22DID D731
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, gear 7 508_NUM_ACTIVATIONS_GEAR_7

  • Request22 D7 5B
  • Service 22DID D75B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, shift solenoid SC2 508_NUM_SHIFT_SOLENOID

  • Request22 D7 52
  • Service 22DID D752
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, shift solenoid SC3 508_NUM_SHIFT_SOLENOID_ACTIVATIONS_SC3

  • Request22 D7 53
  • Service 22DID D753
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, the electromagnetic valve for controlling the automatic transmission locking finger in position p 508_NUM_ACTIVATIONS_P

  • Request22 D7 58
  • Service 22DID D758
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, the electromagnetic valve of clutch C4 508_NUM_ACTIVATIONS_C4

  • Request22 D7 59
  • Service 22DID D759
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, the electromagnetic valve of the clutch C1 508_NUM_ACTIVATIONS_C1

  • Request22 D7 42
  • Service 22DID D742
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation count, torque converter lockup electromagnetic valve 508_NUM_ACTIVATIONS_TQ

  • Request22 D7 46
  • Service 22DID D746
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Activation of additional oil pump, ATN8 gearbox 508_ACTIVATION

  • Request22 D6 16
  • Service 22DID D616
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Additional oil pump control status, atn8 transmission 508_ADDITIONAL_OIL_PMP

  • Request22 D6 17
  • Service 22DID D617
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic restart request from transmission computer 508_AUTOMATIC_RESTART_REQ

  • Request22 D7 0B
  • Service 22DID D70B
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic stop allowed by gearbox computer 508_AUTOMATIC_STOP_ALLOWED

  • Request22 D7 04
  • Service 22DID D704
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission fluid temperature 508_AUTOMATIC_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 D5 50
  • Service 22DID D550
  • Module6A9 → 689
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission in emergency mode 508_AUTOMATIC_TRANS_EMERGENCY

  • Request22 D6 70
  • Service 22DID D670
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission in park position 508_AUTOMATIC_TRANS_PARK

  • Request22 D7 0B
  • Service 22DID D70B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission input shaft mode, calculated 508_AUTOMATIC_TRANS_INPUT_SHFT_MODE

  • Request22 D6 51
  • Service 22DID D651
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2)
Range
0 to 131070 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission input shaft mode, measured 508_AUTOMATIC_TRANS_INPUT_SHFT

  • Request22 D6 50
  • Service 22DID D650
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2)
Range
0 to 131070 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission lubrication solenoid control current 508_AUTOMATIC_TRANS_LUBRICATION

  • Request22 D6 1A
  • Service 22DID D61A
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission oil aging sensor 508_AUTOMATIC_TRANS_OIL

  • Request22 D4 05
  • Service 22DID D405
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission oil drain 508_DRAIN_TRANS

  • Request22 D5 09
  • Service 22DID D509
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission output shaft mode, calculated 508_AUTOMATIC_TRANS_OUTPUT_SHFT_MODE

  • Request22 D6 53
  • Service 22DID D653
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 64 − 8128)
Range
-8128 to 4186112 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission output shaft mode, measured 508_AUTOMATIC_TRANS_OUTPUT

  • Request22 D6 52
  • Service 22DID D652
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission overheat indicator request 508_AUTOMATIC_TRANS

  • Request22 D5 10
  • Service 22DID D510
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Automatic transmission torque request 508_AUTOMATIC_TRANS_TQ

  • Request22 D5 08
  • Service 22DID D508
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2 − 100)
Range
-100 to 410 N·m
Unit
N·m

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Calculated gear in gearbox 508_CALC_GEAR_GEARBOX

  • Request22 D4 09
  • Service 22DID D409
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Calculated nox content at the inlet of the nox catalytic converter 508_CALC_NOX_CONTENT

  • Request22 D5 3F
  • Service 22DID D53F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1024)
Range
0 to 4194303
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Clutch pedal 508_CLU_PEDAL

  • Request22 D4 04
  • Service 22DID D404
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Clutch pedal position value 508_CLU_PEDAL_POS

  • Request22 D4 69
  • Service 22DID D469
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of electromagnetic valve for regulating the pressure in the control system of the oil pressure accumulator, AMN8 gearbox 508_CTRL_CURRENT_P_P

  • Request22 D6 25
  • Service 22DID D625
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of electromagnetic valve of actuator of automatic transmission lock-up in position p 508_CTRL_CURRENT_ELECTROMAGNETIC_VLV_P

  • Request22 D6 1E
  • Service 22DID D61E
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of electromagnetic valve of change of pressure of torque converter lock-up 508_CTRL_CURRENT_P

  • Request22 D6 1C
  • Service 22DID D61C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of the electromagnetic valve for changing the gear shift SC2 508_CTRL_CURRENT

  • Request22 D6 0A
  • Service 22DID D60A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of the electromagnetic valve of change of pressure of clutch C3 508_CTRL_CURRENT_P_C3

  • Request22 D6 14
  • Service 22DID D614
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of the electromagnetic valve of change of pressure of clutch C4 508_CTRL_CURRENT_P_C4

  • Request22 D6 20
  • Service 22DID D620
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of the solenoid valve for changing the pressure of the clutch C1 508_CTRL_CURRENT_P_C1

  • Request22 D6 10
  • Service 22DID D610
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Control current of the solenoid valve for changing the pressure of the clutch C2 508_CTRL_CURRENT_P_C2

  • Request22 D6 12
  • Service 22DID D612
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engaged gear 508_ENGAGED_GEAR

  • Request22 D4 3D
  • Service 22DID D43D
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engaged gear 508_ENGAGED_GEAR_6A9

  • Request22 D5 01
  • Service 22DID D501
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Evaluation of the thermal aging of the NOx catalytic converter 508_EVALUATION_THERMAL

  • Request22 D5 41
  • Service 22DID D541
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 655.35995)
Range
0 to 99.99 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Exhaust gas temperature after upstream catalytic converter 508_EXH_GAS_T_AFTER_PRE

  • Request22 D5 55
  • Service 22DID D555
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Exhaust gas temperature before upstream catalytic converter 508_EXH_GAS_T_BEFORE_PRE

  • Request22 D5 2E
  • Service 22DID D52E
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1400146)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Gear in the process of engaging 508_GEAR_PROCESS

  • Request22 D4 3E
  • Service 22DID D43E
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Gear shift knob under steering wheel 508_GEAR_SHIFT_KNOB

  • Request22 D5 20
  • Service 22DID D520
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Gear shift lever position displayed on instrument panel 508_GEAR_SHIFT_LEVER_POS_ON

  • Request22 D5 00
  • Service 22DID D500
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Maximum clutch travel during gear shift 508_MAX_CLU_TRAVEL

  • Request22 D4 98
  • Service 22DID D498
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of control of electromagnetic valve of automatic transmission lubrication 508_MEAS_CURRENT_CTRL

  • Request22 D6 1B
  • Service 22DID D61B
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of control of electromagnetic valve of change of pressure of torque converter lock-up 508_MEAS_CURRENT_CTRL_P

  • Request22 D6 1D
  • Service 22DID D61D
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the electromagnetic valve for changing the gear shift SC2 508_MEAS_CURRENT

  • Request22 D6 0B
  • Service 22DID D60B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 508_MEAS_CURRENT_P_P

  • Request22 D6 26
  • Service 22DID D626
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the electromagnetic valve of change of pressure of clutch C3 508_MEAS_CURRENT_P_C3

  • Request22 D6 15
  • Service 22DID D615
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the electromagnetic valve of change of pressure of clutch C4 508_MEAS_CURRENT_P_C4

  • Request22 D6 21
  • Service 22DID D621
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the solenoid valve for changing the pressure of the clutch C1 508_MEAS_CURRENT_P_C1

  • Request22 D6 11
  • Service 22DID D611
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the solenoid valve for changing the pressure of the clutch C2 508_MEAS_CURRENT_P_C2

  • Request22 D6 13
  • Service 22DID D613
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Measured current of the solenoid valve for controlling the locking finger of the automatic transmission in position p 508_MEAS_CURRENT_P

  • Request22 D6 1F
  • Service 22DID D61F
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Nitrogen oxide content after catalytic converter, ppm 508_NOX_CONTENT_AFTER

  • Request22 D5 3D
  • Service 22DID D53D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 508_NOX_CONTENT_MEAS

  • Request22 D5 45
  • Service 22DID D545
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Nitrogen oxide content measured at the inlet of the catalytic converter, ppm 508_NOX_CONTENT_MEAS_INLET_NOX

  • Request22 D5 76
  • Service 22DID D576
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Nox catalytic converter urea content 508_NOX_CATALYTIC_CONV

  • Request22 D5 5D
  • Service 22DID D55D
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 999.9999525)
Range
0 to 65.53 g
Unit
g

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of engagements of the electromagnetic valve for regulating the pressure in the oil pressure accumulator control system, AMN8 gearbox 508_NUM_ENGAGEMENTS_P_P

  • Request22 D7 5D
  • Service 22DID D75D
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 1 508_NUM_GEAR_ENGAGEMENTS_1

  • Request22 D7 47
  • Service 22DID D747
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 2 508_NUM_GEAR_ENGAGEMENTS_2

  • Request22 D7 48
  • Service 22DID D748
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 3 508_NUM_GEAR_ENGAGEMENTS_3

  • Request22 D7 49
  • Service 22DID D749
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 4 508_NUM_GEAR_ENGAGEMENTS_4

  • Request22 D7 4A
  • Service 22DID D74A
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 5 508_NUM_GEAR_ENGAGEMENTS_5

  • Request22 D7 4B
  • Service 22DID D74B
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 6 508_NUM_GEAR_ENGAGEMENTS_6

  • Request22 D7 4C
  • Service 22DID D74C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements 8 508_NUM_GEAR_ENGAGEMENTS_8

  • Request22 D7 5C
  • Service 22DID D75C
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements n 508_NUM_GEAR_ENGAGEMENTS_N

  • Request22 D7 4E
  • Service 22DID D74E
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of gear engagements right 508_NUM_GEAR_ENGAGEMENTS

  • Request22 D7 4D
  • Service 22DID D74D
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of shift solenoid operated automatic transmission lubrication control valve 508_NUM_SHIFT_SOLENOID_OPERATED

  • Request22 D7 56
  • Service 22DID D756
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of shift solenoid operated SC4 508_NUM_SHIFT_SOLENOID_OPERATED_SC4

  • Request22 D7 54
  • Service 22DID D754
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of shift solenoid operated SC5 508_NUM_SHIFT_SOLENOID_OPERATED_SC5

  • Request22 D7 55
  • Service 22DID D755
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Number of shift solenoid operated torque converter lock-up pressure regulating valve 508_NUM_SHIFT_SOLENOID_P

  • Request22 D7 57
  • Service 22DID D757
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Operating mode used by the automatic transmission 508_OP_MODE_USED

  • Request22 D6 73
  • Service 22DID D673
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Position of the gearshift lever 508_POS_GEARSHIFT_LEVER

  • Request22 D7 00
  • Service 22DID D700
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Proportional clutch pedal sensor 508_PROPORTIONAL_CLU

  • Request22 D5 6E
  • Service 22DID D56E
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Reverse gear contactor status 508_REVERSE_GEAR

  • Request22 D4 3C
  • Service 22DID D43C
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

SC5 shift solenoid control current 508_SC5_SHIFT_SOLENOID

  • Request22 D6 18
  • Service 22DID D618
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

SC5 shift solenoid measured current 508_SC5_SHIFT_SOLENOID_MEAS

  • Request22 D6 19
  • Service 22DID D619
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Shift solenoid control current SC3 508_SHIFT_SOLENOID_CTRL

  • Request22 D6 0C
  • Service 22DID D60C
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Shift solenoid control current SC4 508_SHIFT_SOLENOID_CTRL_CURRENT_SC4

  • Request22 D6 0E
  • Service 22DID D60E
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Shift solenoid measured current SC3 508_SHIFT_SOLENOID_MEAS

  • Request22 D6 0D
  • Service 22DID D60D
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Shift solenoid measured current SC4 508_SHIFT_SOLENOID_MEAS_CURRENT_SC4

  • Request22 D6 0F
  • Service 22DID D60F
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Shift-lock control 508_SHIFT_LOCK_CTRL

  • Request22 D7 01
  • Service 22DID D701
  • Module6A9 → 689
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Start permission from gearbox computer 508_START_PERMISSION

  • Request22 D4 1A
  • Service 22DID D41A
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Temperature of the nox catalytic converter 508_T_NOX_CATALYTIC_CONV

  • Request22 D5 43
  • Service 22DID D543
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Torque converter lock-up pressure variation solenoid valve control current 508_TQ_CONV_LOCK_UP_P

  • Request22 D6 04
  • Service 22DID D604
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Torque converter lock-up pressure variation solenoid valve control current 508_TQ_CONV_LOCK_UP_P_VARIATION

  • Request22 D6 05
  • Service 22DID D605
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 10)
Range
0 to 2550 mA
Unit
mA

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Torque converter slip mode, theoretical value 508_TQ_CONV_SLIP_MODE

  • Request22 D6 55
  • Service 22DID D655
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 64 − 8128)
Range
-8128 to 8192 rpm
Unit
rpm

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Torque converter status 508_TQ_CONV_STAT

  • Request22 D5 04
  • Service 22DID D504
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Upstream catalytic converter aging 508_PRE_CATALYTIC_CONV

  • Request22 D5 59
  • Service 22DID D559
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.