Accelerator pedal signal 1 voltage 508_ACCEL_PEDAL_SIG_1_V
- Request
22 D4 05 - Service 22
DID D405 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5000.000126)- Range
- -6.55 to 6.55 V
- Unit
- V
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Accelerator pedal signal 2 voltage 508_ACCEL_PEDAL_SIG_2_V
- Request
22 D4 06 - Service 22
DID D406 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5000.000126)- Range
- -6.55 to 6.55 V
- Unit
- V
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Approximate position of turbocharger actuator 508_APPROXIMATE_POS
- Request
22 D4 EC - Service 22
DID D4EC - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Battery current 508_BAT_CURRENT
- Request
22 D4 97 - Service 22
DID D497 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 1024)- Range
- -2097152 to 2097151 A
- Unit
- A
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Centralized voltage maintenance device temperature limiter state 508_CENTRALIZED_V_T
- Request
22 D7 59 - Service 22
DID D759 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Computer power supply voltage 508_COMPUTER_POWER_SUP_V
- Request
22 D5 51 - Service 22
DID D551 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2014, 2019, 2021. Supported for 2012, 2015.
Energy accumulator discharge permission state 508_ENERGY_ACCUMULATOR
- Request
22 D7 4F - Service 22
DID D74F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine control computer supply voltage 508_ENG_CTRL_COMPUTER_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 D4 22 - Service 22
DID D422 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 V
- Unit
- V
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Engine oil level sensor voltage 508_ENG_OIL_LEVEL_SENS_V
- Request
22 D4 1E - Service 22
DID D41E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -6553 to 6553 mV
- Unit
- mV
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Evaluation of the total resistance of the voltage maintaining device 508_EVALUATION_TOT_RES_V
- Request
22 D7 2D - Service 22
DID D72D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128040.9703)- Range
- 0 to 0.511
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Glow plug unit supply voltage 508_PREHEATING_V
- Request
22 D5 0E - Service 22
DID D50E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 V
- Unit
- V
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Minimum battery voltage at startup 508_MIN_BAT_V_STARTUP
- Request
22 D4 D4 - Service 22
DID D4D4 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50.00000112)- Range
- -655 to 655 V
- Unit
- V
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Reversible generator voltage 508_REVERSIBLE_GEN_V
- Request
22 D7 13 - Service 22
DID D713 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 V
- Unit
- V
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Service battery charge state 508_SERVICE_BAT_CHG_ST
- Request
22 D7 42 - Service 22
DID D742 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Service battery charge status 508_SERVICE_BAT_CHG_STAT
- Request
22 D4 67 - Service 22
DID D467 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Service battery temperature 508_SERVICE_BAT_T_6A8
- Request
22 D4 96 - Service 22
DID D496 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Service battery voltage 508_SERVICE_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 D7 8A - Service 22
DID D78A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 V
- Unit
- V
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Service battery wear condition 508_SERVICE_BAT_WEAR
- Request
22 D7 41 - Service 22
DID D741 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Set voltage of energy storage 508_SET_V_ENERGY_STORAGE
- Request
22 D7 34 - Service 22
DID D734 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 32)- Range
- 0 to 7.96 V
- Unit
- V
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Set voltage of storage battery charging 508_SET_V_STORAGE_BAT
- Request
22 D7 66 - Service 22
DID D766 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 V
- Unit
- V
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Set voltage of the reversible generator 508_SET_V_REVERSIBLE_GEN
- Request
22 D7 12 - Service 22
DID D712 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 39.9999994 + 10.60000038)- Range
- 0 to 16.97 V
- Unit
- V
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Stop permitted by voltage maintainer computer 508_STOP_PERMITTED_V
- Request
22 D7 49 - Service 22
DID D749 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Temperature of the electronic power unit of the voltage maintenance device 508_T_ELECTRONIC_POWER_V
- Request
22 D7 30 - Service 22
DID D730 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Turbocharger control duty cycle 508_TURBOCHARGER_CTRL
- Request
22 D4 8A - Service 22
DID D48A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 256)- Range
- -128 to 127 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Turbocharger first electronic boost 508_TURBOCHARGER_FIRST
- Request
22 D4 8C - Service 22
DID D48C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Turbocharger position information 508_TURBOCHARGER_POS
- Request
22 D4 EA - Service 22
DID D4EA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100.0000022)- Range
- 0 to 655 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Turbocharger pressure measured 508_TURBOCHARGER_P_MEAS
- Request
22 D4 D9 - Service 22
DID D4D9 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Turbocharger pressure reference 508_TURBOCHARGER_P
- Request
22 D5 56 - Service 22
DID D556 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Turbocharger, target position 508_TURBOCHARGER_TGT_POS
- Request
22 D4 7B - Service 22
DID D47B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Voltage at the terminals of the energy accumulator 508_V_TERMINALS_ENERGY
- Request
22 D7 20 - Service 22
DID D720 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 32)- Range
- 0 to 7.96 V
- Unit
- V
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Voltage maintainer computer request sent 508_V_MAINTAINER_COMPUTER_REQ
- Request
22 D7 48 - Service 22
DID D748 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Voltage maintainer computer restart permission 508_V_MAINTAINER
- Request
22 D7 47 - Service 22
DID D747 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.
Voltage maintainer status 508_V_MAINTAINER_STAT
- Request
22 D7 2C - Service 22
DID D72C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number