The Peugeot 508 has 12 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Amount of fuel additive remaining in the additive tank 508_AMOUNT_FUEL_ADDITIVE

  • Request22 D5 6C
  • Service 22DID D56C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Amount of fuel additive remaining in the additive tank 508_AMOUNT_FUEL_ADDITIVE

  • Request22 D5 6C
  • Service 22DID D56C
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Calculated fuel injection amount 508_CALC_FUEL_INJ_AMOUNT

  • Request22 D5 63
  • Service 22DID D563
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Raw value

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Desired high pressure common rail fuel pressure 508_DES_HIGH_P_COMMON_P

  • Request22 D4 45
  • Service 22DID D445
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 bar
Unit
bar

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Request01 5E
  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3212.75 L/h
Unit
L/h

Confirmed for 2021.

First fuel additive injection state 508_FIRST_FUEL_ADDITIVE

  • Request22 D5 6F
  • Service 22DID D56F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Fuel pressure 508_FUEL_P

  • Request22 D4 1F
  • Service 22DID D41F
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 999.9999525)
Range
-32.76 to 32.76 bar
Unit
bar

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Fuel temperature 508_FUEL_T

  • Request22 D4 2A
  • Service 22DID D42A
  • Module6A8 → 688
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.14)
Range
-273 to 6280 °C
Unit
°C

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

High fuel pressure measured 508_HIGH_FUEL_P_MEAS

  • Request22 D4 46
  • Service 22DID D446
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 bar
Unit
bar

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Injection angle of the high-pressure fuel pump 508_INJ_ANG_HIGH_P_FUEL

  • Request22 D5 88
  • Service 22DID D588
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Low pressure fuel pump actuator duty cycle 508_LOW_P_FUEL_PMP

  • Request22 D4 72
  • Service 22DID D472
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100.0000022)
Range
-327 to 327 %
Unit
%

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Low pressure fuel pump status 508_LOW_P_FUEL_PMP_STAT

  • Request22 D4 ED
  • Service 22DID D4ED
  • Module6A8 → 688
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.

Minimum fuel level 508_MIN_FLI

  • Request22 D5 6A
  • Service 22DID D56A
  • Module6A8 → 688
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2010 to 2020, 2022 to 2026. Not supported for 2021.