Fuel level CADENZA_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 B0 02
  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing for 2010 to 2016, 2018 to 2020

Example reply from a 2017 Kia Cadenza.

Bits 32 to 39 of the reply, 8 bits.

0x4A = 74 → (74 ÷ 2) = 37 L

Formula
(val ÷ 2)
Range
0 to 127.5 L
Unit
L

Confirmed for 2017. In testing for 2010 to 2016, 2018 to 2020.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Fuel cut CADENZA_FUEL_CUT_7E0Confirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2010 to 2016, 2018 to 2020

Example reply from a 2017 Kia Cadenza.

Bits 64 to 71 of the reply, 8 bits.

0xF4 = 244 → 244

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2017. In testing for 2010 to 2016, 2018 to 2020.

Fuel injection timing #1 CADENZA_FUEL_INJECTION_TIMING_1

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.8192)
Range
0 to 53686.272 ms
Unit
ms

In testing for 2010 to 2016, 2018 to 2020. Not supported for 2017.

Fuel injection timing #2 CADENZA_FUEL_INJECTION_TIMING_2

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.8192)
Range
0 to 53686.272 ms
Unit
ms

In testing for 2010 to 2016, 2018 to 2020. Not supported for 2017.

Fuel injection timing #3 CADENZA_FUEL_INJECTION_TIMING_3

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.8192)
Range
0 to 53686.272 ms
Unit
ms

In testing for 2010 to 2016, 2018 to 2020. Not supported for 2017.

Fuel injection timing #4 CADENZA_FUEL_INJECTION_TIMING_4

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.8192)
Range
0 to 53686.272 ms
Unit
ms

In testing for 2010 to 2016, 2018 to 2020. Not supported for 2017.

Fuel level CADENZA_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 B0 02
  • Service 22DID B002
  • Module7C6 → 7CE
  • Every5 s
  • Testing for 2010 to 2016, 2018 to 2020

Example reply from a 2017 Kia Cadenza.

Bits 32 to 39 of the reply, 8 bits.

0x4A = 74 → (74 ÷ 2) = 37 L

Formula
(val ÷ 2)
Range
0 to 127.5 L
Unit
L

Confirmed for 2017. In testing for 2010 to 2016, 2018 to 2020.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2017.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2017.

Fuel tank level CADENZA_FLIConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request01 2F
  • Service 01PID 2F
  • Module7E0
  • Every60 s
  • Testing for 2010 to 2016, 2018 to 2020

Example reply from a 2017 Kia Cadenza.

Bits 0 to 7 of the reply, 8 bits.

0x03 = 3 → (3 × 100 ÷ 255) = 1.176471 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017. In testing for 2010 to 2016, 2018 to 2020.

Short term fuel % trim, bank 1 CADENZA_STFT_B1

  • Request21 15
  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 0.0030517578 − 100)
Range
0 to 99.99 %
Unit
%

In testing for 2010 to 2016, 2018 to 2020. Not supported for 2017.

Short term fuel % trim, bank 1 idle CADENZA_STFT_B1_IDLE

  • Request21 15
  • Service 21PID 15
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.046875)
Range
0 to 100 %
Unit
%

In testing for 2010 to 2016, 2018 to 2020. Not supported for 2017.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.