Kia Cadenza

Climate parameters

The Kia Cadenza has 8 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Defogging? CADENZA_DEFOG_SWConfirmed

  • Request22 BC 03
  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing for 2010 to 2016, 2018 to 2020

Example reply from a 2017 Kia Cadenza.

Bit 62 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. In testing for 2010 to 2016, 2018 to 2020.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017.

Defogging? CADENZA_DEFOG_SWConfirmed

  • Request22 BC 03
  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing for 2010 to 2016, 2018 to 2020

Example reply from a 2017 Kia Cadenza.

Bit 62 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. In testing for 2010 to 2016, 2018 to 2020.

Evaporator temperature CADENZA_HVAC_EVAPORATOR_TConfirmed

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every5 s
  • Testing for 2010 to 2016, 2018 to 2020

Example reply from a 2017 Kia Cadenza.

Bits 56 to 63 of the reply, 8 bits.

0x56 = 86 → (86 ÷ 2 − 40) = 3 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2017. In testing for 2010 to 2016, 2018 to 2020.

Exterior temperature CADENZA_TEMP_EXTConfirmed

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every5 s
  • Testing for 2010 to 2016, 2018 to 2020

Example reply from a 2017 Kia Cadenza.

Bits 48 to 55 of the reply, 8 bits.

0x55 = 85 → (85 ÷ 2 − 40) = 2.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 80 °C
Unit
°C

Confirmed for 2017. In testing for 2010 to 2016, 2018 to 2020.

Humidity sensor for automatic defogger CADENZA_HVAC_DEFOG_HUMIDITYConfirmed

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every5 s
  • Testing for 2010 to 2016, 2018 to 2020

Example reply from a 2017 Kia Cadenza.

Bits 200 to 207 of the reply, 8 bits.

0x00 = 0 → 0 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2017. In testing for 2010 to 2016, 2018 to 2020.

Interior temperature CADENZA_TEMP_INTConfirmed

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every5 s
  • Testing for 2010 to 2016, 2018 to 2020

Example reply from a 2017 Kia Cadenza.

Bits 40 to 47 of the reply, 8 bits.

0x5D = 93 → (93 ÷ 2 − 40) = 6.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 80 °C
Unit
°C

Confirmed for 2017. In testing for 2010 to 2016, 2018 to 2020.

Interior temperature, passenger legs vent CADENZA_HVAC_IAT_PASSENGER_LEGS_VENT

  • Request22 01 01
  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2010 to 2016, 2018 to 2020. Not supported for 2017.

Interior temperature, passenger vent CADENZA_HVAC_IAT_PASSENGER_VENT

  • Request22 01 01
  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2010 to 2016, 2018 to 2020. Not supported for 2017.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.