Connectable parameters
The Ford Puma has 49 Connectables, parameters that Pelican can monitor automatically.
● Confirmed◆ In testing○ Supported× Not supported
State of charge
HV battery charge FORD_HVBAT_SOCConfirmed
High resolution state of charge.
Pelican can show this parameter as the state of charge.
- Request
22 48 01 - Service 22
DID 4801 - Module
7E4 → 7EC - Every
1 s - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 15 of the reply, 16 bits.
0x4AB5 = 19125 → (19125 ÷ 500) = 38.25 %
- Formula
(val ÷ 500)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
HV battery charge (displayed) FORD_HVBAT_SOC_DISP
The state of charge displayed on the vehicle's dashboard.
Pelican can show this parameter as the state of charge.
- Request
22 48 45 - Service 22
DID 4845 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026. Not supported for 2021.
State of health
HV battery state of health FORD_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Request
22 49 0C - Service 22
DID 490C - Module
7E4 → 7EC - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026. Not supported for 2021.
Charging state
Charging state FORD_CHRG_STATE
Pelican can show this parameter as the charging state.
- Request
22 48 4F - Service 22
DID 484F - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NOT_READY | Not ready |
1 | READY | Ready |
2 | FAULT | Fault |
3 | WAIT | Wait Check |
4 | PRE_COND | Pre-condition |
5 | CHARGING | Charging |
6 | DONE | Done |
7 | EXT | External Charger |
8 | INIT | Initializing |
In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026. Not supported for 2021.
Fuel tank level
Fuel level FORD_FLI_7E0
Pelican can show this parameter as the fuel tank level.
- Request
22 16 C1 - Service 22
DID 16C1 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0030518509)- Range
- 0 to 200 %
- Unit
- %
In testing for 1997 to 2002, 2019 to 2026.
Fuel level FORD_FLIConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 F4 2F - Service 22
DID F42F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
Fuel tank level FORD_FLI_V2
Pelican can show this parameter as the fuel tank level.
- Request
22 61 85 - Service 22
DID 6185 - Module
720 → 728 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1997 to 2002, 2019 to 2026.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. Supported for 2023.
Speed
Vehicle speed FORD_VSSConfirmed
Pelican can show this parameter as the speed.
- Request
22 F4 0D - Service 22
DID F40D - Module
7E0 → 7E8 - Every
250 ms - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0 km/h
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
Vehicle speed VSSSAE J1979Confirmed
Pelican can show this parameter as the speed.
- Request
01 0D - Service 01
PID 0D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2021. Supported for 2023.
Fuel range
Distance to empty, calculated FORD_DTE
Pelican can show this parameter as the fuel range.
- Request
22 41 94 - Service 22
DID 4194 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 km
- Unit
- km
In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026. Not supported for 2021.
Distance to empty, displayed FORD_DTE_DISP
Pelican can show this parameter as the fuel range.
- Request
22 41 95 - Service 22
DID 4195 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 km
- Unit
- km
In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026. Not supported for 2021.
Odometer
Odometer FORD_ODO_V2
Pelican can show this parameter as the odometer.
- Request
22 40 4C - Service 22
DID 404C - Module
720 → 728 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 10)- Range
- 0 to 1677721 km
- Unit
- km
In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026. Not supported for 2021.
Odometer FORD_ODOConfirmed
Pelican can show this parameter as the odometer.
- Request
22 DD 01 - Service 22
DID DD01 - Module
7E0 → 7E8 - Every
5 s - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 23 of the reply, 24 bits.
0x0078D9 = 30937 → 30,937 km
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
Odometer ODOSAE J1979Confirmed
Pelican can show this parameter as the odometer.
- Request
01 A6 - Service 01
PID A6 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2021.
Odometer, battery control module FORD_ODO_BCM
Pelican can show this parameter as the odometer.
- Request
22 DD 01 - Service 22
DID DD01 - Module
760 → 768 - Every
5 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026. Not supported for 2021.
Odometer, brake module FORD_ABS_ODO
Pelican can show this parameter as the odometer.
- Request
22 DD 01 - Service 22
DID DD01 - Module
760 → 768 - Every
5 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 1997 to 2002, 2019 to 2026.
Odometer, forward sensing module FORD_ODO_FSM
Pelican can show this parameter as the odometer.
- Request
22 DD 01 - Service 22
DID DD01 - Module
764 → 76C - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 1997 to 2002, 2019 to 2026.
Odometer, instrument panel FORD_ODO_726
Pelican can show this parameter as the odometer.
- Request
22 DD 01 - Service 22
DID DD01 - Module
726 → 72E - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026. Not supported for 2021.
Odometer, power steering module FORD_ODO_PSCM
Pelican can show this parameter as the odometer.
- Request
22 DD 01 - Service 22
DID DD01 - Module
730 → 738 - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 1997 to 2002, 2019 to 2026.
Vehicle odometer FORD_PCM_VEH_ODOConfirmed
Pelican can show this parameter as the odometer.
- Request
22 F4 A6 - Service 22
DID F4A6 - Module
7E0 → 7E8 - Every
5 s - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 31 of the reply, 32 bits.
0x0008E838 = 583736 → (583736 ÷ 10) = 58,373.6 km
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 km
- Unit
- km
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
Front left tire pressure
Front left tire pressure FORD_TP_FLConfirmed
Pelican can show this parameter as the front left tire pressure.
- Request
22 28 13 - Service 22
DID 2813 - Module
726 → 72E - Every
5 s - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 15 of the reply, 16 bits.
0x0268 = 616 → (616 ÷ 20) = 30.8 psi
- Formula
(val ÷ 20)- Range
- 0 to 3276 psi
- Unit
- psi
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
Front right tire pressure
Front right tire pressure FORD_TP_FRConfirmed
Pelican can show this parameter as the front right tire pressure.
- Request
22 28 14 - Service 22
DID 2814 - Module
726 → 72E - Every
5 s - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 15 of the reply, 16 bits.
0x026D = 621 → (621 ÷ 20) = 31.05 psi
- Formula
(val ÷ 20)- Range
- 0 to 3276 psi
- Unit
- psi
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
Rear left tire pressure
Rear left outer tire pressure FORD_TP_RLOConfirmed
Pelican can show this parameter as the rear left tire pressure.
- Request
22 28 16 - Service 22
DID 2816 - Module
726 → 72E - Every
5 s - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 15 of the reply, 16 bits.
0x0242 = 578 → (578 ÷ 20) = 28.9 psi
- Formula
(val ÷ 20)- Range
- 0 to 3276 psi
- Unit
- psi
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
Rear left tire pressure FORD_TP_RLConfirmed
Pelican can show this parameter as the rear left tire pressure.
- Request
22 28 16 - Service 22
DID 2816 - Module
726 → 72E - Every
5 s - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 15 of the reply, 16 bits.
0x0242 = 578 → (578 ÷ 20) = 28.9 psi
- Formula
(val ÷ 20)- Range
- 0 to 255 psi
- Unit
- psi
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
Rear right tire pressure
Rear right outer tire pressure FORD_TP_RROConfirmed
Pelican can show this parameter as the rear right tire pressure.
- Request
22 28 15 - Service 22
DID 2815 - Module
726 → 72E - Every
5 s - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 15 of the reply, 16 bits.
0x0245 = 581 → (581 ÷ 20) = 29.05 psi
- Formula
(val ÷ 20)- Range
- 0 to 3276 psi
- Unit
- psi
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
Rear right tire pressure FORD_TP_RRConfirmed
Pelican can show this parameter as the rear right tire pressure.
- Request
22 28 15 - Service 22
DID 2815 - Module
726 → 72E - Every
5 s - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 15 of the reply, 16 bits.
0x0245 = 581 → (581 ÷ 20) = 29.05 psi
- Formula
(val ÷ 20)- Range
- 0 to 255 psi
- Unit
- psi
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
CheckEngineLightOn
Malfunction indicator lamp MILSAE J1979Confirmed
The MIL status is OFF during key-on, engine-off bulb check unless MIL has also been commanded ON for a detected malfunction. The status reflects whether there are confirmed DTC(s) stored that are illuminating the MIL. It should not reflect the status of the MIL, which could be on for a function check, flashing I/M readiness or flashing for misfire.
Pelican can show this parameter as the checkEngineLightOn.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2021. Supported for 2023.
Commanded lambda
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2021. Supported for 2023.
Distance since trouble codes were cleared
Distance since DTC clear FORD_DIST_DTC_CLRConfirmed
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
22 F4 31 - Service 22
DID F431 - Module
7E0 → 7E8 - Every
60 s - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 15 of the reply, 16 bits.
0x107F = 4223 → 4,223 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
01 31 - Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2021. Supported for 2023.
Engine coolant temperature
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021. Supported for 2023.
Engine load
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. Supported for 2023.
Engine load FORD_ENG_LOAD_PCTConfirmed
Pelican can show this parameter as the engine load.
- Request
22 F4 04 - Service 22
DID F404 - Module
7E0 → 7E8 - Every
500 ms - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 100 ÷ 255) = 0 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
Engine load, actual FORD_ENG_LOAD_ACTConfirmed
Pelican can show this parameter as the engine load.
- Request
22 F4 43 - Service 22
DID F443 - Module
7E0 → 7E8 - Every
500 ms - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 100 ÷ 255) = 0 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
Engine oil temperature
Engine oil temperature FORD_EOT_7DF
Pelican can show this parameter as the engine oil temperature.
- Request
22 F4 5C - Service 22
DID F45C - Module
7DF - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2002, 2019 to 2026.
Engine oil temperature FORD_EOT
Pelican can show this parameter as the engine oil temperature.
- Request
22 13 10 - Service 22
DID 1310 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 40)- Range
- -40 to 615 °C
- Unit
- °C
In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026. Not supported for 2021.
Engine oil temperature EOTSAE J1979Confirmed
Pelican can show this parameter as the engine oil temperature.
- Request
01 5C - Service 01
PID 5C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 210 °C
- Unit
- °C
Confirmed for 2021.
Engine oil temperature, alternate FORD_EOT_F45C
Pelican can show this parameter as the engine oil temperature.
- Request
22 F4 5C - Service 22
DID F45C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1997 to 2002, 2019 to 2026.
Fuel rate
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Request
01 5E - Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3212.75 L/h
- Unit
- L/h
Confirmed for 2021.
O2 lambda
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2021. Supported for 2023.
Short term fuel trim
Fuel trim, short term FORD_STFTConfirmed
Pelican can show this parameter as the short term fuel trim.
- Request
22 F4 06 - Service 22
DID F406 - Module
7E0 → 7E8 - Every
250 ms - Testing
Example reply from a 2021 Ford Puma.
Bits 0 to 7 of the reply, 8 bits.
0x6D = 109 → (109 × 100 ÷ 128 − 100) = -14.84375 %
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2021. In testing for 1997 to 2002, 2019 to 2020, 2022 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2021. Supported for 2023.
Starter battery voltage
12V battery voltage FORD_VEH_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 2A - Service 22
DID 402A - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20 + 6)- Range
- 0 to 18.75 V
- Unit
- V
In testing for 1997 to 2002, 2019 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2021. Supported for 2023.
StoredDTCCount
Number of DTCs stored in this ECU DTC_CNTSAE J1979Confirmed
Number of confirmed emission-related DTCs stored in the ECU available for display using Service $03.
Pelican can show this parameter as the storedDTCCount.
- Request
01 01 - Service 01
PID 01 - Module
7E0 → 7E8 - Every
10 s
Bits 1 to 7 of the reply, 7 bits.
- Formula
val- Range
- 0 to 127
- Unit
- Number
Confirmed for 2021. Supported for 2023.
Throttle position
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Request
01 11 - Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. Supported for 2023.
Traction battery current
High voltage battery current FORD_HIGH_V_BAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Request
22 48 0B - Service 22
DID 480B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -655 to 655 A
- Unit
- A
In testing for 1997 to 2002, 2019 to 2026.
HV battery current FORD_HVBAT_A
Pelican can show this parameter as the traction battery current.
- Request
22 48 F9 - Service 22
DID 48F9 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -600 to 600 A
- Unit
- A