Fuel parameters
The Toyota Yaris iA has 15 fuel parameters.
● Confirmed◆ In testing○ Supported× Not supported
Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2018.
Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2018.
Fuel level YARIS_IA_FLIConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 F4 2F - Service 22
DID F42F - Module
7E0 → 7E8 - Every
30 s - Testing for 2016 to 2017, 2019 to 2020
Example reply from a 2018 Toyota Yaris iA.
Bits 0 to 7 of the reply, 8 bits.
0xC7 = 199 → (199 × 100 ÷ 255) = 78.039216 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2020.
Fuel level YARIS_IA_FUEL_LEVELConfirmed
- Request
22 61 B1 - Service 22
DID 61B1 - Module
720 → 728 - Every
1 s - Testing for 2016 to 2017, 2019 to 2020
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 55 L
- Unit
- L
Confirmed for 2018. In testing for 2016 to 2017, 2019 to 2020.
Fuel Rail Pressure A FRP_ASAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2018.
Fuel Rail Pressure B FRP_BSAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2018.
Fuel Rail Temperature A FRT_ASAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018.
Fuel Rail Temperature B FRT_BSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2018.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2018. Supported for 2017.
Fuel › Internal
Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.
Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2018.