Toyota FJ Cruiser

Battery parameters

The Toyota FJ Cruiser has 17 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Battery voltage FJ_BAT_VConfirmed

  • Request21 13
  • Service 21PID 13
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2006 to 2011, 2014

Example reply from a 2013 Toyota FJ Cruiser.

Bits 0 to 7 of the reply, 8 bits.

0x84 = 132 → (132 ÷ 10) = 13.2 V

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

Confirmed for 2012 to 2013. In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

+BM voltage FJ_BM_V

  • Request21 41
  • Service 21PID 41
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2006, 2008 to 2014

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 5 ÷ 4096)
Range
0 to 79.998 V
Unit
V

In testing for 2006, 2008 to 2014. Supported for 2007.

Battery current FJ_BAT_CURRENTConfirmed

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006, 2009 to 2014

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 50 ÷ 13107 − 125)
Range
-125 to 124.9 A
Unit
A

Confirmed for 2007 to 2008. In testing for 2006, 2009 to 2014.

Battery temperature FJ_BAT_T

  • Request21 42
  • Service 21PID 42
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2006, 2009 to 2014

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 6513.5 °C
Unit
°C

In testing for 2006, 2009 to 2014. Supported for 2007.

Battery voltage FJ_BAT_VConfirmed

  • Request21 13
  • Service 21PID 13
  • Module7C0 → 7C8
  • Every5 s
  • Testing for 2006 to 2011, 2014

Example reply from a 2013 Toyota FJ Cruiser.

Bits 0 to 7 of the reply, 8 bits.

0x84 = 132 → (132 ÷ 10) = 13.2 V

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

Confirmed for 2012 to 2013. In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010.

Battery voltage FJ_BATTERY_VOLTAGE_7E0Confirmed

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2006, 2009, 2011, 2014

Example reply from a 2013 Toyota FJ Cruiser.

Bits 192 to 207 of the reply, 16 bits.

0x3345 = 13125 → (13125 ÷ 1000) = 13.125 V

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

Confirmed for 2010, 2012 to 2013. In testing for 2006, 2009, 2011, 2014. Supported for 2007 to 2008.

Charge contactor current FJ_SCC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2010, 2013. Supported for 2007 to 2008, 2011.

Main connector solenoid current FJ_SMC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.

Main relay a, solenoid current FJ_SLA_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.

Main relay r solenoid current FJ_SLR_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.

Output speed sensor voltage FJ_NOUT_SENS_V

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 4.999 V
Unit
V

In testing for 2006, 2008 to 2014. Not supported for 2007.

Regenerative braking cooperation FJ_REGEN_COOPERATION

  • Request21 58
  • Service 21PID 58
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.

Regenerative operation FJ_FR_REGEN_OPERATION

  • Request21 48
  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.

Regenerative request FJ_FR_REGEN_REQUEST

  • Request21 48
  • Service 21PID 48
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.

Relay control solenoid current FJ_SRC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.

Service contactor solenoid current FJ_SSC_SOLENOID_CURRENT

  • Request21 A3
  • Service 21PID A3
  • Module7B0 → 7B8
  • Every1 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.

Turbine speed sensor voltage FJ_NT_SENS_V

  • Request21 81
  • Service 21PID 81
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 4.999 V
Unit
V

In testing for 2006, 2008 to 2014. Not supported for 2007.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.