Connectable parameters
The Seat Mii Electric has 14 Connectables, parameters that Pelican can monitor automatically.
● Confirmed◆ In testing○ Supported× Not supported
State of charge
HV battery charge MII_HVBAT_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 02 8C - Service 22
DID 028C - Module
7E5 → 7ED - Every
30 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 7 of the reply, 8 bits.
0xAF = 175 → (175 × 100 ÷ 255) = 68.627451 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020. In testing for 2019, 2021.
HV battery charge, displayed MII_HVBAT_SOC_DISPConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 11 64 - Service 22
DID 1164 - Module
7E0 → 7E8 - Every
1 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 15 of the reply, 16 bits.
0x1B73 = 7027 → (7027 ÷ 100) = 70.27 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020. In testing for 2019, 2021.
State of health
HV battery health MII_HVBAT_SOHConfirmed
Pelican can show this parameter as the state of health.
- Request
22 51 E0 - Service 22
DID 51E0 - Module
7E5 → 7ED - Every
30 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 15 of the reply, 16 bits.
0x39EE = 14830 → (14830 × 0.127 − 1798.574) = 84.836 %
- Formula
(val × 0.127 − 1798.574)- Range
- -1798.574 to 100 %
- Unit
- %
Confirmed for 2020. In testing for 2019, 2021.
Speed
Vehicle speed MII_VSSConfirmed
Current vehicle speed.
Pelican can show this parameter as the speed.
- Request
22 F4 0D - Service 22
DID F40D - Module
7E0 → 7E8 - Every
250 ms - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0 km/h
- Formula
val- Range
- 0 to 255 km/h
- Unit
- km/h
Confirmed for 2020. In testing for 2019, 2021.
Electric range
Range remaining, displayed MII_RANGE_DSPConfirmed
Pelican can show this parameter as the electric range.
- Request
22 22 E0 - Service 22
DID 22E0 - Module
714 → 77E - Every
1 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 15 of the reply, 16 bits.
0x00DC = 220 → 220 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2020. In testing for 2019, 2021.
Odometer
Odometer MII_ODO
Pelican can show this parameter as the odometer.
- Request
22 22 03 - Service 22
DID 2203 - Module
714 → 77E - Every
10 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2019, 2021. Not supported for 2020.
Distance since trouble codes were cleared
Distance traveled since diagnostic trouble codes cleared MII_CLR_DISTConfirmed
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
22 F4 31 - Service 22
DID F431 - Module
7E0 → 7E8 - Every
30 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 15 of the reply, 16 bits.
0x1371 = 4977 → 4,977 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2020. In testing for 2019, 2021.
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
01 31 - Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2020.
Engine speed
Drive motor speed, actual MII_MOTOR_RPM
Pelican can show this parameter as the engine speed.
- Request
22 3E 97 - Service 22
DID 3E97 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.749 rpm
- Unit
- rpm
In testing for 2019 to 2021.
Starter battery voltage
Battery voltage MII_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 5A - Service 22
DID 105A - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 20)- Range
- 0 to 1310700 mV
- Unit
- mV
In testing for 2019 to 2021.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2020.
Terminal 30 voltage MII_KL30_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 F4 42 - Service 22
DID F442 - Module
7E0 → 7E8 - Every
1 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 15 of the reply, 16 bits.
0x3068 = 12392 → (12392 ÷ 1000) = 12.392 V
- Formula
(val ÷ 1000)- Range
- 0 to 65 V
- Unit
- V
Confirmed for 2020. In testing for 2019, 2021.
Traction battery current
HV battery current MII_HVBAT_IConfirmed
Pelican can show this parameter as the traction battery current.
- Request
22 1E 3D - Service 22
DID 1E3D - Module
7E5 → 7ED - Every
250 ms - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 15 of the reply, 16 bits.
0x0714 = 1812 → (1812 ÷ 4 − 511) = -58 A
- Formula
(val ÷ 4 − 511)- Range
- -200 to 200 A
- Unit
- A
Confirmed for 2020. In testing for 2019, 2021.
Traction battery voltage
HV battery voltage MII_HVBAT_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Request
22 1E 3B - Service 22
DID 1E3B - Module
7E5 → 7ED - Every
1 s - Testing for 2019, 2021
Example reply from a 2020 Seat Mii Electric.
Bits 0 to 15 of the reply, 16 bits.
0x051C = 1308 → (1308 ÷ 4) = 327 V
- Formula
(val ÷ 4)- Range
- 0 to 1000 V
- Unit
- V
Confirmed for 2020. In testing for 2019, 2021.