Seat Mii Electric

Climate parameters

The Seat Mii Electric has 5 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Ambient air temperature, cluster MII_DASH_AATConfirmed

  • Request22 10 14
  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing for 2019, 2021

Example reply from a 2020 Seat Mii Electric.

Bits 0 to 7 of the reply, 8 bits.

0x84 = 132 → (132 ÷ 2 − 50) = 16 °C

Formula
(val ÷ 2 − 50)
Range
-50 to 77.5 °C
Unit
°C

Confirmed for 2020. In testing for 2019, 2021.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Air conditioning refrigerant pressure MII_AC_REFRIG_P

  • Request22 10 17
  • Service 22DID 1017
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kPa
Unit
kPa

In testing for 2019 to 2021.

Ambient air temperature MII_AAT

  • Request22 F4 46
  • Service 22DID F446
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2021.

Ambient air temperature, cluster MII_DASH_AATConfirmed

  • Request22 10 14
  • Service 22DID 1014
  • Module714 → 77E
  • Every5 s
  • Testing for 2019, 2021

Example reply from a 2020 Seat Mii Electric.

Bits 0 to 7 of the reply, 8 bits.

0x84 = 132 → (132 ÷ 2 − 50) = 16 °C

Formula
(val ÷ 2 − 50)
Range
-50 to 77.5 °C
Unit
°C

Confirmed for 2020. In testing for 2019, 2021.

Barometric pressure MII_BARO

  • Request22 F4 33
  • Service 22DID F433
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 2019 to 2021.

PTC heater current MII_PTC_HEATER_I

  • Request22 16 04
  • Service 22DID 1604
  • Module7E0
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 16)
Range
0 to 15.937 A
Unit
A

In testing for 2019 to 2021.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.