Engine parameters
The Seat Mii Electric has 37 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Drive motor current MII_MOTOR_I
- Request
22 14 7D - Service 22
DID 147D - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.968 A
- Unit
- A
In testing for 2019 to 2021.
Drive motor effective current MII_MOTOR_I_RMS
- Request
22 46 65 - Service 22
DID 4665 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.937 A
- Unit
- A
In testing for 2019 to 2021.
Drive motor phase U current MII_MOTOR_U_I
- Request
22 3E F9 - Service 22
DID 3EF9 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2019 to 2021.
Drive motor phase U current, unlimited MII_MOTOR_U_I_RAW
- Request
22 46 71 - Service 22
DID 4671 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2019 to 2021.
Drive motor phase V current MII_MOTOR_V_I
- Request
22 3E FA - Service 22
DID 3EFA - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2019 to 2021.
Drive motor phase V current, unlimited MII_MOTOR_V_I_RAW
- Request
22 46 70 - Service 22
DID 4670 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2019 to 2021.
Drive motor phase W current MII_MOTOR_W_I
- Request
22 3E FB - Service 22
DID 3EFB - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2019 to 2021.
Drive motor phase W current, unlimited MII_MOTOR_W_I_RAW
- Request
22 46 6F - Service 22
DID 466F - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 A
- Unit
- A
In testing for 2019 to 2021.
Drive motor power MII_MOTOR_PWR
- Request
22 14 7E - Service 22
DID 147E - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 250)- Range
- -131.072 to 131.068 kW
- Unit
- kW
In testing for 2019 to 2021.
Drive motor power, actual MII_MOTOR_PWR_PE
- Request
22 46 56 - Service 22
DID 4656 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.984 kW
- Unit
- kW
In testing for 2019 to 2021.
Drive motor power, calculated MII_MOTOR_PWR_CALC
- Request
22 46 58 - Service 22
DID 4658 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.984 kW
- Unit
- kW
In testing for 2019 to 2021.
Drive motor speed MII_MOTOR_RPM_ECM
- Request
22 14 9A - Service 22
DID 149A - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.749 rpm
- Unit
- rpm
In testing for 2019 to 2021.
Drive motor speed 2 MII_MOTOR_RPM_2
- Request
22 3E EC - Service 22
DID 3EEC - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.749 rpm
- Unit
- rpm
In testing for 2019 to 2021.
Drive motor speed, actual MII_MOTOR_RPM
Pelican can show this parameter as the engine speed.
- Request
22 3E 97 - Service 22
DID 3E97 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.749 rpm
- Unit
- rpm
In testing for 2019 to 2021.
Drive motor speed, measured MII_MOTOR_RPM_ACT
- Request
22 46 59 - Service 22
DID 4659 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.749 rpm
- Unit
- rpm
In testing for 2019 to 2021.
Drive motor speed, standard MII_MOTOR_RPM_SAE
- Request
22 F4 0C - Service 22
DID F40C - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.749 rpm
- Unit
- rpm
In testing for 2019 to 2021.
Drive motor stator temperature MII_MOTOR_STATOR_T
- Request
22 46 72 - Service 22
DID 4672 - Module
7E6 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
Drive motor temperature MII_MOTOR_T
- Request
22 3E 94 - Service 22
DID 3E94 - Module
7E6 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
Drive motor torque MII_MOTOR_TQ
- Request
22 14 7F - Service 22
DID 147F - Module
7E0 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 3)- Range
- -10922.666 to 10922.333 N·m
- Unit
- N·m
In testing for 2019 to 2021.
Drive motor torque, actual MII_MOTOR_TQ_PE
- Request
22 3E E9 - Service 22
DID 3EE9 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 N·m
- Unit
- N·m
In testing for 2019 to 2021.
Drive motor torque, calculated MII_MOTOR_TQ_CALC
- Request
22 03 08 - Service 22
DID 0308 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.937 N·m
- Unit
- N·m
In testing for 2019 to 2021.
Drive motor voltage MII_MOTOR_V
- Request
22 14 84 - Service 22
DID 1484 - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2019 to 2021.
Power electronics internal supply voltage 1 MII_PE_SUPPLY_V1
- Request
22 46 6C - Service 22
DID 466C - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.998 V
- Unit
- V
In testing for 2019 to 2021.
Power electronics internal supply voltage 2 MII_PE_SUPPLY_V2
- Request
22 46 6B - Service 22
DID 466B - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.998 V
- Unit
- V
In testing for 2019 to 2021.
Power electronics link voltage MII_PE_LINK_V
- Request
22 3E 93 - Service 22
DID 3E93 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2019 to 2021.
Power electronics link voltage setpoint MII_PE_LINK_V_SET
- Request
22 3E ED - Service 22
DID 3EED - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2019 to 2021.
Power electronics phase U transistor temperature MII_PE_IGBT_U_T
- Request
22 46 64 - Service 22
DID 4664 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
Power electronics phase V transistor temperature MII_PE_IGBT_V_T
- Request
22 46 63 - Service 22
DID 4663 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
Power electronics phase W transistor temperature MII_PE_IGBT_W_T
- Request
22 46 62 - Service 22
DID 4662 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.984 °C
- Unit
- °C
In testing for 2019 to 2021.
Power electronics traction voltage MII_PE_HV_V
- Request
22 46 75 - Service 22
DID 4675 - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.968 V
- Unit
- V
In testing for 2019 to 2021.
Power electronics transistor supply voltage MII_PE_IGBT_SUPPLY_V
- Request
22 46 5A - Service 22
DID 465A - Module
7E6 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 512)- Range
- -64 to 63.998 V
- Unit
- V
In testing for 2019 to 2021.
Rotor position sensor cosine amplitude MII_ROTOR_COS_AMP_V
- Request
22 4E 91 - Service 22
DID 4E91 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.998 V
- Unit
- V
In testing for 2019 to 2021.
Rotor position sensor cosine offset MII_ROTOR_COS_OFS_V
- Request
22 4E 93 - Service 22
DID 4E93 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.998 V
- Unit
- V
In testing for 2019 to 2021.
Rotor position sensor cosine track MII_ROTOR_COS
- Request
22 46 61 - Service 22
DID 4661 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2021.
Rotor position sensor sine amplitude MII_ROTOR_SIN_AMP_V
- Request
22 4E 90 - Service 22
DID 4E90 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.998 V
- Unit
- V
In testing for 2019 to 2021.
Rotor position sensor sine track MII_ROTOR_SIN
- Request
22 46 60 - Service 22
DID 4660 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2021.
Rotor position sensor sine voltage MII_ROTOR_SIN_V
- Request
22 4E 92 - Service 22
DID 4E92 - Module
7E6 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.998 V
- Unit
- V
In testing for 2019 to 2021.