MINI Hardtop

Engine parameters

The MINI Hardtop has 89 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Coolant temperature HARDTOP_COOLANTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request22 41 1E
  • Service 22DID 411E
  • Module6F1 → 612
  • Every1 s
  • Testing for 2001 to 2019, 2021 to 2022, 2024 to 2026

Example reply from a 2023 MINI Hardtop.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → 0 °C

Formula
val
Range
0 to 200 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2001 to 2015, 2017, 2019, 2021 to 2022, 2024 to 2026. Not supported for 2016, 2018.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Accelerator pedal position MINI_APP

  • Request22 DE 9C
  • Service 22DID DE9C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 %
Unit
%

In testing for 2001 to 2026.

Automatic air recirculation MINI_HVAC_AUC

  • Request22 D9 30
  • Service 22DID D930
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Automatic transmission fluid temperature HARDTOP_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request21 0A
  • Service 21PID 0A
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 55)
Range
-55 to 200 °C
Unit
°C

In testing for 2001 to 2015, 2017, 2019, 2021 to 2022, 2024 to 2026. Not supported for 2016, 2018, 2020, 2023.

Automatic transmission fluid temperature HARDTOP_ATF_TEMP

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 DA 12
  • Service 22DID DA12
  • Module6F1 → 618
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 48)
Range
-48 to 65487 °C
Unit
°C

In testing for 2001 to 2016, 2019, 2022, 2024 to 2026. Not supported for 2017 to 2018, 2020 to 2021, 2023.

Barometric pressure HARDTOP_BARO

  • Request22 42 01
  • Service 22DID 4201
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 256)
Range
0 to 255.99 kPa
Unit
kPa

In testing for 2001 to 2026.

Boost pressure HARDTOP_BOOST_P

  • Request22 42 05
  • Service 22DID 4205
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511.99 kPa
Unit
kPa

In testing for 2001 to 2026.

Boost pressure, set point HARDTOP_BOOST_P_SET

  • Request22 4A B0
  • Service 22DID 4AB0
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 256)
Range
0 to 255.99 kPa
Unit
kPa

In testing for 2001 to 2026.

Cabin temperature MINI_CABIN_T

  • Request22 D8 5C
  • Service 22DID D85C
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2001 to 2026.

Catalyst temperature HARDTOP_CAT_T

  • Request22 58 2F
  • Service 22DID 582F
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.15)
Range
-273.15 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Charge cycle efficiency MINI_OBC_EFF_CYCLE

  • Request22 DE 85
  • Service 22DID DE85
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2001 to 2026.

Charger 12V supply voltage MINI_OBC_KL30_V

  • Request22 DE 86
  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 2001 to 2026.

Charger AC current, phase 1 MINI_OBC_AC_I_1

  • Request22 DE 87
  • Service 22DID DE87
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 A
Unit
A

In testing for 2001 to 2026.

Charger AC current, phase 2 MINI_OBC_AC_I_2

  • Request22 DE 87
  • Service 22DID DE87
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 A
Unit
A

In testing for 2001 to 2026.

Charger AC current, phase 3 MINI_OBC_AC_I_3

  • Request22 DE 87
  • Service 22DID DE87
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 A
Unit
A

In testing for 2001 to 2026.

Charger AC voltage, phase 1 MINI_OBC_AC_V_1

  • Request22 DE 86
  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2001 to 2026.

Charger AC voltage, phase 2 MINI_OBC_AC_V_2

  • Request22 DE 86
  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2001 to 2026.

Charger AC voltage, phase 3 MINI_OBC_AC_V_3

  • Request22 DE 86
  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
val
Range
0 to 65535 V
Unit
V

In testing for 2001 to 2026.

Charger DC efficiency MINI_OBC_EFF_DC

  • Request22 DE 85
  • Service 22DID DE85
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2001 to 2026.

Charger derating MINI_OBC_DERATING

  • Request22 DE 84
  • Service 22DID DE84
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2001 to 2026.

Charger grid frequency, phase 1 MINI_OBC_GRID_HZ

  • Request22 DE 84
  • Service 22DID DE84
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 Hz
Unit
Hz

In testing for 2001 to 2026.

Charger HV DC current MINI_OBC_HV_I

  • Request22 DE 87
  • Service 22DID DE87
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 10 − 204.7)
Range
-204 to 6348 A
Unit
A

In testing for 2001 to 2026.

Charger HV DC voltage MINI_OBC_HV_V

  • Request22 DE 86
  • Service 22DID DE86
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 V
Unit
V

In testing for 2001 to 2026.

Charger HV output power MINI_OBC_PWR

  • Request22 DE 85
  • Service 22DID DE85
  • Module6F1 → 615
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 2001 to 2026.

Charging cable current rating MINI_CHG_CABLE_I

  • Request22 DE F5
  • Service 22DID DEF5
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255 A
Unit
A

In testing for 2001 to 2026.

Charging plug state MINI_CHG_PLUG_ST

  • Request22 DE F5
  • Service 22DID DEF5
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

Climate control off MINI_HVAC_OFF

  • Request22 D9 2C
  • Service 22DID D92C
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Consumption, kwh/100km HARDTOP_CONS_KWH_100KM

  • Request22 D1 2A
  • Service 22DID D12A
  • Module6F1 → 660
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Number

In testing for 2001 to 2026.

Coolant temperature HARDTOP_COOLANTConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request22 41 1E
  • Service 22DID 411E
  • Module6F1 → 612
  • Every1 s
  • Testing for 2001 to 2019, 2021 to 2022, 2024 to 2026

Example reply from a 2023 MINI Hardtop.

Bits 16 to 23 of the reply, 8 bits.

0x00 = 0 → 0 °C

Formula
val
Range
0 to 200 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2001 to 2015, 2017, 2019, 2021 to 2022, 2024 to 2026. Not supported for 2016, 2018.

Crank torque HARDTOP_CRANK_TQ

  • Request22 58 BA
  • Service 22DID 58BA
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 N·m
Unit
N·m

In testing for 2001 to 2026.

DC charging pin cover open MINI_DC_PIN_COVER

  • Request22 DE FA
  • Service 22DID DEFA
  • Module6F1 → 614
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Drive electronics processor 0 temperature MINI_EME_T_MC0

  • Request22 DE 8C
  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The value is signed.

Formula
(val × 39 ÷ 2500)
Range
-511 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Drive electronics processor 2 temperature MINI_EME_T_MC2

  • Request22 DE 8C
  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The value is signed.

Formula
(val × 39 ÷ 2500)
Range
-511 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Drive inverter gate driver temperature MINI_INV_T_GATE

  • Request22 DE 8C
  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
(val × 39 ÷ 2500)
Range
-511 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Drive inverter HV DC current MINI_EM_INV_I_DC

  • Request22 DE 8A
  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 A
Unit
A

In testing for 2001 to 2026.

Drive inverter phase U temperature MINI_INV_T_U

  • Request22 DE 8C
  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 39 ÷ 2500)
Range
-511 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Drive inverter phase V temperature MINI_INV_T_V

  • Request22 DE 8C
  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val × 39 ÷ 2500)
Range
-511 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Drive inverter phase W temperature MINI_INV_T_W

  • Request22 DE 8C
  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val × 39 ÷ 2500)
Range
-511 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Drive motor excitation current MINI_EM_I_EXC

  • Request22 DE 8A
  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 A
Unit
A

In testing for 2001 to 2026.

Drive motor phase U current MINI_EM_I_U

  • Request22 DE 8A
  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 A
Unit
A

In testing for 2001 to 2026.

Drive motor phase V current MINI_EM_I_V

  • Request22 DE 8A
  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 A
Unit
A

In testing for 2001 to 2026.

Drive motor phase W current MINI_EM_I_W

  • Request22 DE 8A
  • Service 22DID DE8A
  • Module6F1 → 61A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 A
Unit
A

In testing for 2001 to 2026.

Drive motor speed MINI_EM_RPM

  • Request22 DE A7
  • Service 22DID DEA7
  • Module6F1 → 61A
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2 − 5000)
Range
-5000 to 27767 rpm
Unit
rpm

In testing for 2001 to 2026.

Drive motor temperature 1 MINI_EM_T_1

  • Request22 DE A6
  • Service 22DID DEA6
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 39 ÷ 2500)
Range
-511 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Drive motor temperature 2 MINI_EM_T_2

  • Request22 DE A6
  • Service 22DID DEA6
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val × 39 ÷ 2500)
Range
-511 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Drive motor torque, actual MINI_EM_TQ

  • Request22 DE A7
  • Service 22DID DEA7
  • Module6F1 → 61A
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383 N·m
Unit
N·m

In testing for 2001 to 2026.

Drive motor torque, requested MINI_EM_TQ_TGT

  • Request22 DE A7
  • Service 22DID DEA7
  • Module6F1 → 61A
  • Every250 ms
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383 N·m
Unit
N·m

In testing for 2001 to 2026.

Engine load HARDTOP_LOAD

  • Request22 58 13
  • Service 22DID 5813
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 %
Unit
%

In testing for 2001 to 2026.

Engine load 2 HARDTOP_LOAD_2

  • Request22 4A 4B
  • Service 22DID 4A4B
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2001 to 2026.

Engine load, target HARDTOP_LOAD_TGT

  • Request22 48 0C
  • Service 22DID 480C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 3 ÷ 128)
Range
0 to 1535 %
Unit
%

In testing for 2001 to 2026.

Engine oil pressure HARDTOP_EOPConfirmed

  • Request22 58 6F
  • Service 22DID 586F
  • Module6F1 → 612
  • Every1 s
  • Testing for 2001 to 2017, 2019, 2022, 2024 to 2026

Example reply from a 2023 MINI Hardtop.

Bits 0 to 15 of the reply, 16 bits.

0x03CB = 971 → (971 ÷ 1000) = 0.971 bar

Formula
(val ÷ 1000)
Range
0 to 65.535 bar
Unit
bar

Confirmed for 2018, 2020 to 2021, 2023. In testing for 2001 to 2015, 2019, 2022, 2024 to 2026. Not supported for 2016 to 2017.

Engine oil temperature HARDTOP_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 44 02
  • Service 22DID 4402
  • Module6F1 → 612
  • Every1 s
  • Testing for 2001 to 2017, 2019, 2021 to 2022, 2024 to 2026

Example reply from a 2023 MINI Hardtop.

Bits 8 to 15 of the reply, 8 bits.

0x40 = 64 → (64 ÷ 2) = 32 °C

Formula
(val ÷ 2)
Range
0 to 127.5 °C
Unit
°C

Confirmed for 2018, 2020, 2023. In testing for 2001 to 2015, 2017, 2019, 2021 to 2022, 2024 to 2026. Not supported for 2016.

Engine oil temperature HARDTOP_EOT_6F1

  • Request22 DA 25
  • Service 22DID DA25
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val − 48)
Range
-500 to 500 °C
Unit
°C

In testing for 2001 to 2016, 2019, 2022, 2024 to 2026. Not supported for 2017 to 2018, 2020 to 2021, 2023.

Engine oil temperature HARDTOP_EOT_DME

Pelican can show this parameter as the engine oil temperature.

  • Request22 44 08
  • Service 22DID 4408
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.15)
Range
-273.15 to 6280 °C
Unit
°C

In testing for 2001 to 2026.

Engine oil temperature HARDTOP_OIL_TEMPConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 45 06
  • Service 22DID 4506
  • Module6F1 → 612
  • Every1 s
  • Testing for 2001 to 2017, 2019, 2021 to 2022, 2024 to 2026

Example reply from a 2023 MINI Hardtop.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0 °C

Formula
val
Range
0 to 200 °C
Unit
°C

Confirmed for 2018, 2020, 2023. In testing for 2001 to 2015, 2017, 2019, 2021 to 2022, 2024 to 2026. Not supported for 2016.

Engine oil temperature, alternate HARDTOP_OIL_TEMP_ALTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 57 C3
  • Service 22DID 57C3
  • Module6F1 → 612
  • Every1 s
  • Testing for 2001 to 2017, 2019, 2021 to 2022, 2024 to 2026

Example reply from a 2023 MINI Hardtop.

Bits 0 to 15 of the reply, 16 bits.

0x0235 = 565 → (565 ÷ 10) = 56.5 °C

Formula
(val ÷ 10)
Range
0 to 200 °C
Unit
°C

Confirmed for 2018, 2020, 2023. In testing for 2001 to 2015, 2017, 2019, 2021 to 2022, 2024 to 2026. Not supported for 2016.

Engine temperature HARDTOP_ETConfirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request22 43 00
  • Service 22DID 4300
  • Module6F1 → 612
  • Every1 s
  • Testing for 2021 to 2022, 2024 to 2026

Example reply from a 2023 MINI Hardtop.

Bits 0 to 15 of the reply, 16 bits.

0x0CA1 = 3233 → (3233 ÷ 10 − 273.15) = 50.15 °C

Formula
(val ÷ 10 − 273.15)
Range
-273.15 to 6280 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2021 to 2022, 2024 to 2026.

Engine temperature HARDTOP_ET_8Confirmed

Pelican can show this parameter as the engine coolant temperature.

  • Request22 43 00
  • Service 22DID 4300
  • Module6F1 → 612
  • Every1 s
  • Testing for 2001 to 2017

Example reply from a 2018 MINI Hardtop.

Bits 0 to 7 of the reply, 8 bits.

0x86 = 134 → (134 × 1.34 − 54) = 125.56 °F

Formula
(val × 1.34 − 54)
Range
-54 to 287.7 °F
Unit
°F

Confirmed for 2018. In testing for 2001 to 2015, 2017. Not supported for 2016.

Exhaust gas calculated temperature HARDTOP_EGT_CALC

  • Request22 4C 5B
  • Service 22DID 4C5B
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 1200 °C
Unit
°C

In testing for 2001 to 2015, 2017, 2019, 2021 to 2022, 2024 to 2026. Not supported for 2016, 2018, 2020, 2023.

Ignition angle HARDTOP_IGN_ANGLE

  • Request22 59 FA
  • Service 22DID 59FA
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2001 to 2026.

Ignition timing, cylinder 1 HARDTOP_IGN_TIMING_1

  • Request22 4A 49
  • Service 22DID 4A49
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °
Unit
°

In testing for 2001 to 2026.

Ignition timing, cylinder 2 HARDTOP_IGN_TIMING_2

  • Request22 4A 4A
  • Service 22DID 4A4A
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °
Unit
°

In testing for 2001 to 2026.

Ignition timing, cylinder 3 HARDTOP_IGN_TIMING_3

  • Request22 4A 4C
  • Service 22DID 4A4C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °
Unit
°

In testing for 2001 to 2026.

Ignition timing, cylinder 4 HARDTOP_IGN_TIMING_4

  • Request22 4A 4D
  • Service 22DID 4A4D
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °
Unit
°

In testing for 2001 to 2026.

Intake air temperature HARDTOP_IATConfirmed

  • Request22 40 15
  • Service 22DID 4015
  • Module6F1 → 612
  • Every1 s
  • Testing for 2001 to 2019, 2021 to 2022, 2024 to 2026

Example reply from a 2023 MINI Hardtop.

Bits 8 to 15 of the reply, 8 bits.

0x6A = 106 → 106 °C

Formula
val
Range
0 to 150 °C
Unit
°C

Confirmed for 2020, 2023. In testing for 2001 to 2017, 2019, 2021 to 2022, 2024 to 2026. Not supported for 2018.

Intake air temperature HARDTOP_IAT_DME

  • Request22 58 0F
  • Service 22DID 580F
  • Module6F1 → 612
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.75 − 48)
Range
-48 to 143.25 °C
Unit
°C

In testing for 2001 to 2026.

Intake manifold pressure HARDTOP_MAP

  • Request22 4A 2D
  • Service 22DID 4A2D
  • Module6F1 → 612
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511.99 kPa
Unit
kPa

In testing for 2001 to 2026.

Kickdown HARDTOP_KICKDOWN

  • Request22 DA 1F
  • Service 22DID DA1F
  • Module6F1 → 618
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2001 to 2016, 2019, 2022, 2024 to 2026. Not supported for 2017 to 2018, 2020 to 2021, 2023.

Lambda HARDTOP_LAMBDA

  • Request22 58 89
  • Service 22DID 5889
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 16 ÷ 65535)
Range
0 to 16
Unit
Number

In testing for 2001 to 2026.

Lambda 1, excess air ratio HARDTOP_LAMBDA_6F1Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request22 40 0B
  • Service 22DID 400B
  • Module6F1 → 612
  • Every1 s
  • Testing for 2001 to 2017, 2019, 2021 to 2022, 2024 to 2026

Example reply from a 2023 MINI Hardtop.

Bits 40 to 47 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 100) = 0

Formula
(val ÷ 100)
Range
0 to 2
Unit
Number

Confirmed for 2018, 2020, 2023. In testing for 2001 to 2015, 2017, 2019, 2021 to 2022, 2024 to 2026. Not supported for 2016.

Lambda 2 HARDTOP_LAMBDA_2

  • Request22 58 2C
  • Service 22DID 582C
  • Module6F1 → 612
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4096)
Range
0 to 15.99
Unit
Number

In testing for 2001 to 2026.

Oil level HARDTOP_OIL_LEVEL

  • Request22 44 2C
  • Service 22DID 442C
  • Module6F1 → 612
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2026.

On-board charger board temperature MINI_OBC_T_BOARD

  • Request22 DE 8C
  • Service 22DID DE8C
  • Module6F1 → 61A
  • Every5 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The value is signed.

Formula
(val × 39 ÷ 2500)
Range
-511 to 511 °C
Unit
°C

In testing for 2001 to 2026.

Recirculation MINI_HVAC_RECIRC

  • Request22 D9 31
  • Service 22DID D931
  • Module6F1 → 678
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2001 to 2026.

Rev limiter HARDTOP_REV_LIMIT

  • Request22 4A 2E
  • Service 22DID 4A2E
  • Module6F1 → 612
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 2001 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2020. Supported for 2017 to 2019, 2021 to 2024.

Speed from satellite positioning MINI_GPS_SPD

  • Request22 D0 30
  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2001 to 2026.

Steering torque MINI_STEER_TQ

  • Request22 DB 99
  • Service 22DID DB99
  • Module6F1 → 630
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 128)
Range
-256 to 255 N·m
Unit
N·m

In testing for 2001 to 2026.

Time in D HARDTOP_TIME_DConfirmed

  • Request22 DA 37
  • Service 22DID DA37
  • Module6F1 → 618
  • Every30 s
  • Testing for 2001 to 2017, 2019 to 2026

Example reply from a 2018 MINI Hardtop.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2001 to 2016, 2019, 2022, 2024 to 2026. Not supported for 2017, 2020 to 2021, 2023.

Time in M HARDTOP_TIME_MConfirmed

  • Request22 DA 37
  • Service 22DID DA37
  • Module6F1 → 618
  • Every30 s
  • Testing for 2001 to 2017, 2019 to 2026

Example reply from a 2018 MINI Hardtop.

Bits 16 to 23 of the reply, 8 bits.

0xA2 = 162 → 162

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2001 to 2016, 2019, 2022, 2024 to 2026. Not supported for 2017, 2020 to 2021, 2023.

Time in S HARDTOP_TIME_SConfirmed

  • Request22 DA 37
  • Service 22DID DA37
  • Module6F1 → 618
  • Every30 s
  • Testing for 2001 to 2017, 2019 to 2026

Example reply from a 2018 MINI Hardtop.

Bits 8 to 15 of the reply, 8 bits.

0x96 = 150 → 150

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2018. In testing for 2001 to 2016, 2019, 2022, 2024 to 2026. Not supported for 2017, 2020 to 2021, 2023.

Trip computer average consumption MINI_BC_AVG_CONS

  • Request22 D1 29
  • Service 22DID D129
  • Module6F1 → 660
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 kWh/100 km
Unit
kWh/100 km

In testing for 2001 to 2026.

Trip computer average speed MINI_BC_AVG_SPD

  • Request22 D1 29
  • Service 22DID D129
  • Module6F1 → 660
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 km/h
Unit
km/h

In testing for 2001 to 2026.

Trip computer range MINI_BC_RANGE

  • Request22 D1 29
  • Service 22DID D129
  • Module6F1 → 660
  • Every30 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 km
Unit
km

In testing for 2001 to 2026.

Variable geometry turbocharger calibration angle HARDTOP_VGT_CAL_ANGLE

  • Request22 DF E7
  • Service 22DID DFE7
  • Module6F1
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 156.25 ÷ 10000)
Range
0 to 1000 °
Unit
°

In testing for 2001 to 2019, 2021 to 2026. Not supported for 2020.

Wheel sensor speed 1 MINI_NBT_WHL_SPD_1

  • Request22 D0 30
  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2001 to 2026.

Wheel sensor speed 2 MINI_NBT_WHL_SPD_2

  • Request22 D0 30
  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2001 to 2026.

Wheel sensor speed 3 MINI_NBT_WHL_SPD_3

  • Request22 D0 30
  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2001 to 2026.

Wheel sensor speed 4 MINI_NBT_WHL_SPD_4

  • Request22 D0 30
  • Service 22DID D030
  • Module6F1 → 663
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 km/h
Unit
km/h

In testing for 2001 to 2026.

Yaw rate HARDTOP_YAW_RATE

  • Request21 04
  • Service 21PID 04
  • Module6F1 → 629
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
(val × 0.4 ÷ 100)
Range
-131.072 to 131.068 m/s²
Unit
m/s²

In testing for 2001 to 2015, 2017, 2019, 2021 to 2022, 2024 to 2026. Not supported for 2016, 2018, 2020, 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.