MINI Hardtop

Door parameters

The MINI Hardtop has 8 door parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Charge flap closed MINI_CHG_FLAP_CLOSED

  • Request22 DE F1
  • Service 22DID DEF1
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2001 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Charge flap closed MINI_CHG_FLAP_CLOSED

  • Request22 DE F1
  • Service 22DID DEF1
  • Module6F1 → 614
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 1
Unit
Yes or no

In testing for 2001 to 2026.

Driver door open HARDTOP_DOOR_DRIVER

  • Request22 DC DD
  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2016, 2019, 2022, 2024 to 2026. Not supported for 2017 to 2018, 2020 to 2021, 2023.

Hood open HARDTOP_HOOD

  • Request22 DC DD
  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2016, 2019, 2022, 2024 to 2026. Not supported for 2017 to 2018, 2020 to 2021, 2023.

Locked HARDTOP_CENTRAL_LOCK

Overall lock state of the vehicle

  • Request22 DC DD
  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2016, 2019, 2022, 2024 to 2026. Not supported for 2017 to 2018, 2020 to 2021, 2023.

Passenger door open HARDTOP_DOOR_PASSENGER

  • Request22 DC DD
  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2016, 2019, 2022, 2024 to 2026. Not supported for 2017 to 2018, 2020 to 2021, 2023.

Rear driver door open HARDTOP_DOOR_DRIVER_REAR

  • Request22 DC DD
  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2016, 2019, 2022, 2024 to 2026. Not supported for 2017 to 2018, 2020 to 2021, 2023.

Rear passenger door open HARDTOP_DOOR_PASSENGER_REAR

  • Request22 DC DD
  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2016, 2019, 2022, 2024 to 2026. Not supported for 2017 to 2018, 2020 to 2021, 2023.

Trunk open HARDTOP_TRUNK

  • Request22 DC DD
  • Service 22DID DCDD
  • Module6F1 → 656
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2001 to 2016, 2019, 2022, 2024 to 2026. Not supported for 2017 to 2018, 2020 to 2021, 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.