DTC parameters
The Lexus GX 470 has 30 DTC parameters.
● Confirmed◆ In testing○ Supported× Not supported
2nd air monitor, available LEXUS_2ND_AIR_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
2nd air monitor, incomplete LEXUS_2ND_AIR_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Air conditioning monitor, available LEXUS_A_C_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 19 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Air conditioning monitor, incomplete LEXUS_A_C_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Catalyst monitor, available LEXUS_CATALYST_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Catalyst monitor, incomplete LEXUS_CATALYST_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Complete parts monitor available? LEXUS_COMPLETE_PARTS_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2003 to 2009.
Complete parts monitor, available LEXUS_COMPLETE_PARTS_MON
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Distance traveled since diagnostic trouble codes cleared CLR_DISTSAE J1979Confirmed
Distance accumulated since DTCs were cleared (via an external test equipment or possibly, a battery disconnect). This parameter is not associated with any particular DTC. It is simply an indication for inspection/maintenance, of the last time an external test equipment was used to clear DTCs. If greater than 65,535 km have occurred, will remain at 65,535 km and not wrap to zero.
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
01 31 - Service 01
PID 31 - Module
7E0 → 7E8 - Every
15 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2005 to 2006. Supported for 2008.
Evaporative monitor_icmpl LEXUS_EVAP_MONITOR_ICMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Evaporative monitor, available LEXUS_EVAP_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Exhaust gas recirculation and variable valve timing monitor, available LEXUS_EGR_VVT_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 16 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Exhaust gas recirculation and variable valve timing monitor, incomplete LEXUS_EGR_VVT_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Fuel system monitor, available LEXUS_FUEL_SYSTEM_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Heated catalyst monitor available? LEXUS_HEATED_CATALYST_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2003 to 2009.
Heated catalyst monitor incomplete? LEXUS_HEATED_CATALYST_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2003 to 2009.
Heated catalyst monitor, available LEXUS_HEATED_CAT_MON_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Heated catalyst monitor, incomplete LEXUS_HEATED_CAT_MON
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Malfunction indicator lamp LEXUS_MILConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Example reply from a 2006 Lexus GX 470.
Bit 0 of the reply.
0b1 = 1 → 1
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2005 to 2006. In testing for 2003 to 2004, 2007 to 2009.
MIL ON run distance LEXUS_MILON_RUN_DISTANCE
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 2003 to 2009.
Misfire monitor, available LEXUS_MISFIRE_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Number of DTCs LEXUS_IA_DTC_CNTD
- Request
22 02 02 - Service 22
DID 0202 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2009.
Number of emission DTC LEXUS_NUMBER_OF_EMISSION_DTCConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Example reply from a 2006 Lexus GX 470.
Bits 1 to 7 of the reply, 7 bits.
0b0000000 = 0 → 0
- Formula
val- Range
- 0 to 127
- Unit
- Number
Confirmed for 2005 to 2006. In testing for 2003 to 2004, 2007 to 2009.
O2S heater monitor available? LEXUS_O2S_A_FS_HEATER_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2003 to 2009.
O2S heater monitor incomplete? LEXUS_O2S_A_FS_HEATER_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
In testing for 2003 to 2009.
O2S heater monitor, available LEXUS_O2S_HEATER_MON_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 17 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
O2S heater monitor, incomplete LEXUS_O2S_HEATER_MON
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
O2S monitor, available LEXUS_O2S_A_FS_MONITOR_AVAIL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 18 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
O2S monitor, incomplete LEXUS_O2S_A_FS_MONITOR_INCMPL
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Running time from MIL ON LEXUS_RUNNING_TIME_FROM_MIL_ON
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
In testing for 2003 to 2009.