Battery parameters
The Lexus GX 470 has 344 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
+BM voltage LEXUS_BM_V
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2003 to 2009.
1st turbocharger outlet pressure, control valve LEXUS_1ST_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2003 to 2009.
2nd turbocharger outlet pressure LEXUS_2ND_TRUBOCHARGER_OUTLET_P
- Request
22 11 AF - Service 22
DID 11AF - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2003 to 2009.
2nd turbocharger outlet pressure, control valve LEXUS_2ND_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2003 to 2009.
12V battery current LEXUS_12V_C
- Request
22 15 F7 - Service 22
DID 15F7 - Module
7D2 → 7DA - Every
500 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 38.147 ÷ 10000 − 125)- Range
- -125 to 124 A
- Unit
- A
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
12V battery temperature LEXUS_12V_T
- Request
22 15 F8 - Service 22
DID 15F8 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
12V battery voltage LEXUS_12V_V_V2
Pelican can show this parameter as the starter battery voltage.
- Request
22 15 EE - Service 22
DID 15EE - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.31448 + 0.0125)- Range
- 0 to 80.2 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
12V battery voltage before system main relay LEXUS_12V_BAT_V_BEFORE_SMR
- Request
22 10 7E - Service 22
DID 107E - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 61 ÷ 50000 + 11.25)- Range
- 0 to 11.56 V
- Unit
- V
In testing for 2003 to 2009.
12V battery voltage smoothed LEXUS_12V_BAT_V_SMOOTHED
- Request
22 1F 42 - Service 22
DID 1F42 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2003 to 2009.
AC charging operation status LEXUS_AC_OP
- Request
22 16 84 - Service 22
DID 1684 - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | STOP | Stopped |
1 | STARTUP | Starting up |
2 | RUNNING | Running |
3 | FINISHING | Finishing |
In testing for 2003 to 2009.
AC current limit LEXUS_AC_A_LIMIT
- Request
22 16 19 - Service 22
DID 1619 - Module
745 → 74D - Every
5 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2003 to 2009.
AC target power LEXUS_AC_P_TGT
- Request
22 16 19 - Service 22
DID 1619 - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 kW
- Unit
- kW
In testing for 2003 to 2009.
AC usable power LEXUS_AC_P_USABLE
- Request
22 16 65 - Service 22
DID 1665 - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 100)- Range
- 0 to 2.55 kW
- Unit
- kW
In testing for 2003 to 2009.
Accumulated time of battery low LEXUS_ACCUMULATED_TIME_BAT
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2009.
Accumulated time of battery too high LEXUS_ACCUMULATED_TIME_BAT_TOO
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2003 to 2009.
Air fuel sensor voltage, bank 1 sensor 1 LEXUS_AFS_VOLTAGE_B1S1
- Request
21 04 - Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 7.99 ÷ 65535)- Range
- 0 to 7.99 V
- Unit
- V
In testing for 2003 to 2009.
Aux battery voltage LEXUS_AUX_BAT_V
- Request
22 10 02 - Service 22
DID 1002 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 61 ÷ 50000)- Range
- 0 to 79.95 V
- Unit
- V
In testing for 2003 to 2009.
Aux. battery capacity after IG OFF LEXUS_AUX_BAT_CAP_AFTER_IG_OFF
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 2003 to 2009.
Aux. battery capacity after IG ON LEXUS_AUX_BAT_CAP_AFTER_IG_ON
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 2003 to 2009.
Auxiliary battery current LEXUS_AUXILIARY_BAT
- Request
22 18 02 - Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2525 ÷ 13107 − 12500)- Range
- -12500 to -12451 A
- Unit
- A
In testing for 2003 to 2009.
Auxiliary battery temperature LEXUS_AUXILIARY_BAT_T
- Request
21 41 - Service 21
PID 41 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215
- Unit
- Number
In testing for 2003 to 2009.
Auxiliary battery voltage LEXUS_AUX_V
Pelican can show this parameter as the starter battery voltage.
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val ÷ 5 − 25.6)- Range
- -25.6 to 25.4 V
- Unit
- V
In testing for 2003 to 2009.
Auxiliary battery voltage LEXUS_AUXILIARY_BAT_V
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 47 ÷ 38550 − 40)- Range
- -40 to 39.9 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 1 voltage LEXUS_BAT_BLOCK_V_V01
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 2 voltage LEXUS_BAT_BLOCK_V_V02
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 3 voltage LEXUS_BAT_BLOCK_V_V03
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 4 voltage LEXUS_BAT_BLOCK_V_V04
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 5 voltage LEXUS_BAT_BLOCK_V_V05
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 6 voltage LEXUS_BAT_BLOCK_V_V06
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 7 voltage LEXUS_BAT_BLOCK_V_V07
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 8 voltage LEXUS_BAT_BLOCK_V_V08
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 9 voltage LEXUS_BAT_BLOCK_V_V09
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 10 voltage, raw count LEXUS_BAT_BLOCK_V_V10_RAW
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 6553500)- Range
- 0 to 79.99
- Unit
- Number
In testing for 2003 to 2009.
Battery block 11 voltage LEXUS_BAT_BLOCK_V_V11
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 12 voltage LEXUS_BAT_BLOCK_V_V12
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 13 voltage LEXUS_BAT_BLOCK_V_V13
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 14 voltage LEXUS_BAT_BLOCK_V_V14
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 16 voltage LEXUS_BAT_BLOCK_V_V16
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2003 to 2009.
Battery block 17 voltage LEXUS_BAT_BLOCK_V_V17
- Request
21 81 - Service 21
PID 81 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val × 7999 ÷ 6553500)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V01 LEXUS_BATTERY_BLOCK_VOL_V01
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V02 LEXUS_BATTERY_BLOCK_VOL_V02
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V03 LEXUS_BATTERY_BLOCK_VOL_V03
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V04 LEXUS_BATTERY_BLOCK_VOL_V04
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V05 LEXUS_BATTERY_BLOCK_VOL_V05
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V06 LEXUS_BATTERY_BLOCK_VOL_V06
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V07 LEXUS_BATTERY_BLOCK_VOL_V07
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V08 LEXUS_BATTERY_BLOCK_VOL_V08
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V09 LEXUS_BATTERY_BLOCK_VOL_V09
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V10 LEXUS_BATTERY_BLOCK_VOL_V10
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V11 LEXUS_BATTERY_BLOCK_VOL_V11
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V12 LEXUS_BATTERY_BLOCK_VOL_V12
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V13 LEXUS_BATTERY_BLOCK_VOL_V13
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V14 LEXUS_BATTERY_BLOCK_VOL_V14
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block vol -V15 LEXUS_BATTERY_BLOCK_VOL_V15
- Request
21 CE - Service 21
PID CE - Module
7E2 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
Battery block with the maximum voltage LEXUS_BAT_BLOCK_NUMBER_MAX_V
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val + 1)- Range
- 0 to 256
- Unit
- Number
In testing for 2003 to 2009.
Battery block with the minimum voltage LEXUS_BAT_BLOCK_NUMBER_MIN_V
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val + 1)- Range
- 0 to 256
- Unit
- Number
In testing for 2003 to 2009.
Battery block, maximum voltage LEXUS_BAT_BLOCK_MAX_V
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery block, minimum voltage LEXUS_BAT_BLOCK_MIN_V
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0012205692)- Range
- 0 to 79.99 V
- Unit
- V
In testing for 2003 to 2009.
Battery charging power LEXUS_CHG_P
- Request
22 10 D4 - Service 22
DID 10D4 - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 kW
- Unit
- kW
In testing for 2003 to 2009.
Battery current LEXUS_BAT_CURRENT
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 50 ÷ 13107 − 125)- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2003 to 2009.
Battery current LEXUS_BAT_CURRENT_700
- Request
22 15 F7 - Service 22
DID 15F7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 49 ÷ 12850 − 125)- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2003 to 2009.
Battery heater temperature LEXUS_BAT_HEATER_T
- Request
22 18 24 - Service 22
DID 1824 - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery status of full charge LEXUS_BAT_STAT_FULL_CHG
- Request
22 15 E5 - Service 22
DID 15E5 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 255 ÷ 2)- Range
- 0 to 32512.5 Ah
- Unit
- Ah
In testing for 2003 to 2009.
Battery temperature LEXUS_BAT_T
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 6513.5 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature LEXUS_BAT_T_700
- Request
22 15 F8 - Service 22
DID 15F8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature LEXUS_BAT_T_700_2
- Request
22 1F F8 - Service 22
DID 1FF8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 40)- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 2003 to 2009.
Battery temperature 01 LEXUS_BAT_T_01
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 02 LEXUS_BAT_T_02
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 03 LEXUS_BAT_T_03
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 04 LEXUS_BAT_T_04
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 05 LEXUS_BAT_T_05
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 06 LEXUS_BAT_T_06
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 07 LEXUS_BAT_T_07
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 08 LEXUS_BAT_T_08
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 09 LEXUS_BAT_T_09
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 10 LEXUS_BAT_T_10
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 11 LEXUS_BAT_T_11
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 12 LEXUS_BAT_T_12
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 13 LEXUS_BAT_T_13
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 14 LEXUS_BAT_T_14
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 15 LEXUS_BAT_T_15
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery temperature 16 LEXUS_BAT_T_16
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Battery voltage LEXUS_12V_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 02 - Service 22
DID 1002 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 12.207 ÷ 10000)- Range
- 0 to 15 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Battery voltage LEXUS_12V_V_700
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 02 - Service 22
DID 1002 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 12.207 ÷ 10000)- Range
- 0 to 79 V
- Unit
- V
In testing for 2003 to 2009.
Battery voltage LEXUS_BAT_V
- Request
21 13 - Service 21
PID 13 - Module
7C0 → 7C8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Battery voltage LEXUS_BATTERY_VOLTAGE_7E0
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2003 to 2009.
Battery voltage LEXUS_BATTERY_VOLTAGE_7E0_V2
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2003 to 2009.
Battery voltage LEXUS_BATTERY_VOLTAGE_V2
Pelican can show this parameter as the starter battery voltage.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Boost converter carrier frequency LEXUS_CONV_CARRIER
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
1 s - Testing
Bit 71 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Boost converter gate LEXUS_CONV_GATE
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
1 s - Testing
Bit 66 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Boost converter input voltage LEXUS_VL
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 V
- Unit
- V
In testing for 2003 to 2009.
Boost converter output voltage LEXUS_VH
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 V
- Unit
- V
In testing for 2003 to 2009.
Boost converter pressure ratio LEXUS_BOOST_RATIO
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 0.392)- Range
- 0 to 99.96 %
- Unit
- %
In testing for 2003 to 2009.
Boost converter temperature LEXUS_CONV_T
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
Boost converter voltage after boosting LEXUS_VH_V_AFTER_BOOSTING_7E2
- Request
21 74 - Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 2003 to 2009.
Boost converter voltage before boosting LEXUS_VL_V_BEFORE_BOOSTING_7E2
- Request
21 74 - Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 2003 to 2009.
Charge contactor current LEXUS_SCC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Charge stop request code LEXUS_CHG_STOP_REQ
- Request
22 16 67 - Service 22
DID 1667 - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2009.
Charger input power LEXUS_CHG_IN_P
- Request
22 16 1D - Service 22
DID 161D - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327.675 kW
- Unit
- kW
In testing for 2003 to 2009.
Charger operation status LEXUS_CHGR_OP
- Request
22 16 19 - Service 22
DID 1619 - Module
745 → 74D - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | STANDBY | Standby |
1 | READY | Ready |
2 | STOP | Stopped |
3 | ROB_STOP | Stopped by request |
In testing for 2003 to 2009.
Charger output power LEXUS_CHGR_OUT_P
- Request
22 16 1E - Service 22
DID 161E - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327.675 kW
- Unit
- kW
In testing for 2003 to 2009.
Charger output power, target LEXUS_CHGR_OUT_P_TGT
- Request
22 16 1E - Service 22
DID 161E - Module
745 → 74D - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327.675 kW
- Unit
- kW
In testing for 2003 to 2009.
Charger supply voltage type LEXUS_CHG_V_TYPE
- Request
22 16 1C - Service 22
DID 161C - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | V100 | 100V series |
2 | V200 | 200V series |
In testing for 2003 to 2009.
Charging integrated current of aux. battery LEXUS_CHG_INTEGRATED
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2003 to 2009.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2006.
Control system mode LEXUS_CTRL_MODE
- Request
22 10 D1 - Service 22
DID 10D1 - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | DRIVING | Driving |
3 | CHARGING | Charging |
In testing for 2003 to 2009.
Converter input voltage too high LEXUS_OVERVOLTAGE_INPUT
- Request
21 74 - Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 33 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Dark current of battery LEXUS_DARK_CURRENT_BAT
- Request
22 15 E7 - Service 22
DID 15E7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2003 to 2009.
DC charger maximum current LEXUS_DC_STA_A_MAX
- Request
22 16 79 - Service 22
DID 1679 - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 2003 to 2009.
DC charger maximum power LEXUS_DC_STA_P_MAX
- Request
22 16 6A - Service 22
DID 166A - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 kW
- Unit
- kW
In testing for 2003 to 2009.
DC charger maximum voltage LEXUS_DC_STA_V_MAX
- Request
22 16 81 - Service 22
DID 1681 - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
DC charger present current LEXUS_DC_STA_A
- Request
22 16 6C - Service 22
DID 166C - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 2003 to 2009.
DC charger present voltage LEXUS_DC_STA_V
- Request
22 16 6B - Service 22
DID 166B - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2003 to 2009.
DC high level communication state LEXUS_HLC
- Request
22 16 66 - Service 22
DID 1666 - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2009.
DC-DC converter high side voltage LEXUS_DC_DC_CONV_HIGH_SIDE_V
- Request
22 11 1E - Service 22
DID 111E - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1220703 ÷ 10000000)- Range
- 0 to 7999 V
- Unit
- V
In testing for 2003 to 2009.
DC-DC converter low side voltage LEXUS_DC_DC_CONV_LOW_SIDE_V
- Request
22 11 1D - Service 22
DID 111D - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1953 ÷ 25000)- Range
- 0 to 19.92 V
- Unit
- V
In testing for 2003 to 2009.
DC-DC converter, target voltage before charging LEXUS_DC_DC_CONV_TGT_V
- Request
22 11 1F - Service 22
DID 111F - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1220703 ÷ 10000000)- Range
- 0 to 7999 V
- Unit
- V
In testing for 2003 to 2009.
Delta SOC LEXUS_DELTA_SOC
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2003 to 2009.
Discharging integrated current of aux. battery LEXUS_DISCHARGING
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2003 to 2009.
Distance since last battery cable disconnection LEXUS_DIST_SINCE_BAT_DISC
- Request
22 10 6C - Service 22
DID 106C - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Engine control module control mode, driving control mode=1,current sensor offset mode=2,external charge control mode=3,power supply end mode=4 LEXUS_ENG_CTRL_MODULE_CTRL_1_2_3_4
- Request
21 9B - Service 21
PID 9B - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2009.
Full charge capacity 1 LEXUS_CAP_1
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2003 to 2009.
Full charge capacity 2 LEXUS_CAP_2
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2003 to 2009.
Full charge capacity 3 LEXUS_CAP_3
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2003 to 2009.
Full charge capacity 4 LEXUS_CAP_4
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2003 to 2009.
Full charge capacity 5 LEXUS_CAP_5
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2003 to 2009.
Full charge capacity 6 LEXUS_CAP_6
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2003 to 2009.
Full charge capacity 7 LEXUS_CAP_7
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2003 to 2009.
Full charge capacity 8 LEXUS_CAP_8
- Request
22 1D 3E - Service 22
DID 1D3E - Module
747 → 74F - Every
60 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 Ah
- Unit
- Ah
In testing for 2003 to 2009.
High voltage battery charge control, kw LEXUS_HVBAT_CHG_CTRL_KW
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5
- Unit
- Number
In testing for 2003 to 2009.
High voltage battery discharge control, kw LEXUS_HVBAT_DCHG_CTRL_KW
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5
- Unit
- Number
In testing for 2003 to 2009.
High voltage battery intake air temperature LEXUS_HVBAT_IAT
- Request
21 87 - Service 21
PID 87 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0039047837 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
HV battery block 1 internal resistance LEXUS_HVBAT_BLOCK_1_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 1 voltage LEXUS_HVBAT_BLOCK_1_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block 2 internal resistance LEXUS_HVBAT_BLOCK_2_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 2 voltage LEXUS_HVBAT_BLOCK_2_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block 3 internal resistance LEXUS_HVBAT_BLOCK_3_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 3 voltage LEXUS_HVBAT_BLOCK_3_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block 4 internal resistance LEXUS_HVBAT_BLOCK_4_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 4 voltage LEXUS_HVBAT_BLOCK_4_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block 5 internal resistance LEXUS_HVBAT_BLOCK_5_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 5 voltage LEXUS_HVBAT_BLOCK_5_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block 6 internal resistance LEXUS_HVBAT_BLOCK_6_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 6 voltage LEXUS_HVBAT_BLOCK_6_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block 7 internal resistance LEXUS_HVBAT_BLOCK_7_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 7 voltage LEXUS_HVBAT_BLOCK_7_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block 8 internal resistance LEXUS_HVBAT_BLOCK_8_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 8 voltage LEXUS_HVBAT_BLOCK_8_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block 9 internal resistance LEXUS_HVBAT_BLOCK_9_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 9 voltage LEXUS_HVBAT_BLOCK_9_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block 10 internal resistance LEXUS_HVBAT_BLOCK_10_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 10 voltage LEXUS_HVBAT_BLOCK_10_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block 11 internal resistance LEXUS_HVBAT_BLOCK_11_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 11 voltage LEXUS_HVBAT_BLOCK_11_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block 12 internal resistance LEXUS_HVBAT_BLOCK_12_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 12 voltage LEXUS_HVBAT_BLOCK_12_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block 13 internal resistance LEXUS_HVBAT_BLOCK_13_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 13 voltage LEXUS_HVBAT_BLOCK_13_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block 14 internal resistance LEXUS_HVBAT_BLOCK_14_R
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mΩ
- Unit
- mΩ
In testing for 2003 to 2009.
HV battery block 14 voltage LEXUS_HVBAT_BLOCK_14_V
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block count LEXUS_HVBAT_BLOCKS
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2009.
HV battery block voltage, highest LEXUS_HVBAT_BLOCK_V_MAX
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block voltage, lowest LEXUS_HVBAT_BLOCK_V_MIN
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 V
- Unit
- V
In testing for 2003 to 2009.
HV battery block with the highest voltage LEXUS_HVBAT_BLOCK_V_MAX_NO
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2009.
HV battery block with the lowest voltage LEXUS_HVBAT_BLOCK_V_MIN_NO
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2009.
HV battery charge LEXUS_HVBAT_SOC
Pelican can show this parameter as the state of charge.
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 %
- Unit
- %
In testing for 2003 to 2009.
HV battery charge (max) LEXUS_HVBAT_SOC_MAX
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery charge (min) LEXUS_HVBAT_SOC_MIN
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery charge power limit LEXUS_HVBAT_CHG_LIM
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 kW
- Unit
- kW
In testing for 2003 to 2009.
HV battery charge spread LEXUS_HVBAT_DELTA_SOC
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 100)- Range
- 0 to 2.55 %
- Unit
- %
In testing for 2003 to 2009.
HV battery charge voltage LEXUS_HVBAT_CHRG_V
- Request
22 16 09 - Service 22
DID 1609 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery charge, displayed LEXUS_HVBAT_SOC_DISPLAY
Pelican can show this parameter as the state of charge.
- Request
22 17 39 - Service 22
DID 1739 - Module
745 → 74D - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery charge, hybrid control LEXUS_HV_SOC
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val × 0.392)- Range
- 0 to 99.96 %
- Unit
- %
In testing for 2003 to 2009.
HV battery current LEXUS_HVBAT_C
Pelican can show this parameter as the traction battery current.
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 A
- Unit
- A
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery current LEXUS_HVBAT_I
Pelican can show this parameter as the traction battery current.
- Request
21 CE - Service 21
PID CE - Module
7E3 → 7EB - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2003 to 2009.
HV battery DC inhibit time LEXUS_HVBAT_DC_INHIBIT_TIME
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 24 to 39 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 2003 to 2009.
HV battery discharge power limit LEXUS_HVBAT_DISCHG_LIM
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 kW
- Unit
- kW
In testing for 2003 to 2009.
HV battery discharge power limit LEXUS_WOUT
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val × 320)- Range
- 0 to 81600 W
- Unit
- W
In testing for 2003 to 2009.
HV battery fan motor voltage LEXUS_HVBAT_FAN_V
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 5 − 25.6)- Range
- -25.6 to 25.4 V
- Unit
- V
In testing for 2003 to 2009.
HV battery fan speed LEXUS_HVBAT_FAN
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2009.
HV battery high charge time LEXUS_HVBAT_HIGH_TIME
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 2003 to 2009.
HV battery hot temperature time LEXUS_HVBAT_HOT_TIME
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 2003 to 2009.
HV battery intake air temperature LEXUS_HVBAT_INTAKE_T
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2003 to 2009.
HV battery low charge time LEXUS_HVBAT_LOW_TIME
- Request
21 D0 - Service 21
PID D0 - Module
7E3 → 7EB - Every
30 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 2003 to 2009.
HV battery maximum temperature LEXUS_HVBAT_MAX_T
- Request
22 18 29 - Service 22
DID 1829 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery minimum temperature LEXUS_HVBAT_MIN_T
- Request
22 18 2A - Service 22
DID 182A - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery temperature 1 LEXUS_HVBAT_T_1
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2003 to 2009.
HV battery temperature 1 LEXUS_T_BATT_TB1
- Request
21 87 - Service 21
PID 87 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0039047837 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
HV battery temperature 2 LEXUS_HVBAT_T_2
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2003 to 2009.
HV battery temperature 2 LEXUS_T_BATT_TB2
- Request
21 87 - Service 21
PID 87 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 0.0039047837 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
HV battery temperature 3 LEXUS_HVBAT_T_3
- Request
21 CF - Service 21
PID CF - Module
7E3 → 7EB - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2003 to 2009.
HV battery temperature 3 LEXUS_T_BATT_TB3
- Request
21 87 - Service 21
PID 87 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 0.0039047837 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2003 to 2009.
HV battery voltage LEXUS_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 156.25 ÷ 10000)- Range
- 0 to 1023 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Hybrid battery 1 fan LEXUS_HYBRID_BAT_1_FAN
- Request
22 18 02 - Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2003 to 2009.
Hybrid battery 1 fan LEXUS_HYBRID_BAT_1_FAN_747
- Request
22 18 02 - Service 22
DID 1802 - Module
747 → 74F - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2003 to 2009.
Hybrid battery block 1 average voltage LEXUS_HYBRID_BAT_BLOCK_1_V
- Request
22 18 19 - Service 22
DID 1819 - Module
747 → 74F - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65536)- Range
- 0 to 4.99 °F
- Unit
- °F
In testing for 2003 to 2009.
Hybrid battery block 2 average voltage LEXUS_HYBRID_BAT_BLOCK_2_V
- Request
22 18 19 - Service 22
DID 1819 - Module
747 → 74F - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65536)- Range
- 0 to 4.99 °F
- Unit
- °F
In testing for 2003 to 2009.
Hybrid battery block 3 average voltage LEXUS_HYBRID_BAT_BLOCK_3_V
- Request
22 18 19 - Service 22
DID 1819 - Module
747 → 74F - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65536)- Range
- 0 to 4.99 °F
- Unit
- °F
In testing for 2003 to 2009.
Hybrid battery block 4 average voltage LEXUS_HYBRID_BAT_BLOCK_4_V
- Request
22 18 19 - Service 22
DID 1819 - Module
747 → 74F - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65536)- Range
- 0 to 4.99 °F
- Unit
- °F
In testing for 2003 to 2009.
Hybrid battery block 5 average voltage LEXUS_HYBRID_BAT_BLOCK_5_V
- Request
22 18 19 - Service 22
DID 1819 - Module
747 → 74F - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65536)- Range
- 0 to 4.99 °F
- Unit
- °F
In testing for 2003 to 2009.
Hybrid battery current LEXUS_HYBRID_BAT_CURRENT
- Request
22 1F 9A - Service 22
DID 1F9A - Module
747 → 74F - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 A
- Unit
- A
In testing for 2003 to 2009.
Hybrid battery heater temperature 2 LEXUS_HYBRID_BAT_HEATER_T_2
- Request
22 18 25 - Service 22
DID 1825 - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 58)- Range
- -58 to 401 °F
- Unit
- °F
In testing for 2003 to 2009.
Hybrid battery intake air temperature 1 LEXUS_HYBRID_BAT_IAT_1
- Request
22 18 0B - Service 22
DID 180B - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2003 to 2009.
Hybrid battery intake air temperature 2 LEXUS_HYBRID_BAT_IAT_2
- Request
22 18 0B - Service 22
DID 180B - Module
747 → 74F - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2003 to 2009.
Hybrid battery SOC LEXUS_HYBRID_BAT_SOC
- Request
22 1F 5B - Service 22
DID 1F5B - Module
747 → 74F - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2009.
Hybrid battery temperature 1 LEXUS_HYBRID_BAT_T_1
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2003 to 2009.
Hybrid battery temperature 2 LEXUS_HYBRID_BAT_T_2
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 58)- Range
- -58 to 401 °F
- Unit
- °F
In testing for 2003 to 2009.
Hybrid battery temperature 3 LEXUS_HYBRID_BAT_T_3
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2003 to 2009.
Hybrid battery voltage LEXUS_HYBRID_BAT_V
- Request
22 F1 9A - Service 22
DID F19A - Module
7D2 → 7DA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 V
- Unit
- V
In testing for 2003 to 2009.
Hybrid battery voltage LEXUS_HYBRID_BAT_V_747
- Request
22 F1 9A - Service 22
DID F19A - Module
747 → 74F - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 V
- Unit
- V
In testing for 2003 to 2009.
Initial engine battery voltage lower limit LEXUS_INITIAL_ENG_BAT_V_LO
- Request
22 15 F6 - Service 22
DID 15F6 - Module
700 → 708 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2003 to 2009.
Inverter input voltage too high LEXUS_OVERVOLTAGE_INPUT_INVERTER
- Request
21 74 - Service 21
PID 74 - Module
7E2 → 7EA - Every
1 s - Testing
Bit 34 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Last charge outcome code LEXUS_CHG_OUTCOME
- Request
22 16 88 - Service 22
DID 1688 - Module
745 → 74D - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2009.
Main battery charging requested LEXUS_CHARGE_REQ
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
1 s - Testing
Bit 11 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Main connector solenoid current LEXUS_SMC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Main relay a, solenoid current LEXUS_SLA_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Main relay r solenoid current LEXUS_SLR_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Minimum permission power LEXUS_CHG_P_PERMIT
- Request
22 16 A1 - Service 22
DID 16A1 - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 kW
- Unit
- kW
In testing for 2003 to 2009.
Number of battery blocks LEXUS_NUM_BAT_BLOCKS
- Request
21 92 - Service 21
PID 92 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2009.
Output speed sensor voltage LEXUS_NOUT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2003 to 2009.
Plug-in switch status LEXUS_PISW
- Request
22 16 69 - Service 22
DID 1669 - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2003 to 2009.
Power resource current LEXUS_IB
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val × 2 − 256)- Range
- -256 to 254 A
- Unit
- A
In testing for 2003 to 2009.
Power resource voltage LEXUS_VB
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 V
- Unit
- V
In testing for 2003 to 2009.
Regenerative braking cooperation LEXUS_REGEN_COOPERATION
- Request
21 58 - Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Regenerative operation LEXUS_FR_REGEN_OPERATION
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Regenerative request LEXUS_FR_REGEN_REQUEST
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Relay control solenoid current LEXUS_SRC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Service contactor solenoid current LEXUS_SSC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Short circuit wave highest value LEXUS_SHORT_WAVE_V
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2009.
Sleep time of battery sensor LEXUS_SLEEP_TIME_BATSENS
- Request
22 15 F0 - Service 22
DID 15F0 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 h
- Unit
- h
In testing for 2003 to 2009.
SOC at ignition on LEXUS_SOC_AFTER_IG_ON
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2003 to 2009.
SOC max LEXUS_SOC_MAX
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2003 to 2009.
SOC min LEXUS_SOC_MIN
- Request
21 98 - Service 21
PID 98 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2003 to 2009.
State of charge LEXUS_SOC
Pelican can show this parameter as the state of charge.
- Request
22 1F 5B - Service 22
DID 1F5B - Module
7D2 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
State of charge LEXUS_ST_CHG_ALL_BAT
- Request
21 01 - Service 21
PID 01 - Module
7E2 → 7EA - Every
30 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2009.
State of charge LEXUS_STATE_OF_CHARGE
Pelican can show this parameter as the state of charge.
- Request
21 C3 - Service 21
PID C3 - Module
7E2 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 0.392)- Range
- 0 to 99.96 %
- Unit
- %
In testing for 2003 to 2009.
State of charge, battery ECU LEXUS_SOC_747
- Request
22 1F 5B - Service 22
DID 1F5B - Module
747 → 74F - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2.55)- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2009.
State of charge, charging control LEXUS_SOC_745
- Request
22 17 38 - Service 22
DID 1738 - Module
745 → 74D - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2003 to 2009.
System main relay 1 LEXUS_SMR1
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
1 s - Testing
Bit 63 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
System main relay 2 LEXUS_SMR2
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
1 s - Testing
Bit 62 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
System main relay 3 LEXUS_SMR3
- Request
21 C4 - Service 21
PID C4 - Module
7E2 - Every
1 s - Testing
Bit 61 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2003 to 2009.
Target charging current LEXUS_CHG_A_TGT
- Request
22 16 6D - Service 22
DID 166D - Module
745 → 74D - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 2003 to 2009.
Turbine speed sensor voltage LEXUS_NT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2003 to 2009.
Vh-voltage after boosting LEXUS_VH_V_AFTER_BOOSTING
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 2003 to 2009.
Vl-voltage before boosting LEXUS_VL_V_BEFORE_BOOSTING
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 2003 to 2009.
Voltage of battery sensor LEXUS_V_BATSENS
- Request
22 15 EE - Service 22
DID 15EE - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13333 ÷ 10922500)- Range
- 0 to 79.9979 V
- Unit
- V
In testing for 2003 to 2009.
Battery › Cells
HV battery cell #01 voltage LEXUS_HVBAT_C01_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #02 voltage LEXUS_HVBAT_C02_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #03 voltage LEXUS_HVBAT_C03_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #04 voltage LEXUS_HVBAT_C04_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #05 voltage LEXUS_HVBAT_C05_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #06 voltage LEXUS_HVBAT_C06_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #07 voltage LEXUS_HVBAT_C07_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #08 voltage LEXUS_HVBAT_C08_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #09 voltage LEXUS_HVBAT_C09_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #10 voltage LEXUS_HVBAT_C10_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #11 voltage LEXUS_HVBAT_C11_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #12 voltage LEXUS_HVBAT_C12_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #13 voltage LEXUS_HVBAT_C13_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #14 voltage LEXUS_HVBAT_C14_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #15 voltage LEXUS_HVBAT_C15_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #16 voltage LEXUS_HVBAT_C16_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #17 voltage LEXUS_HVBAT_C17_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #18 voltage LEXUS_HVBAT_C18_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #19 voltage LEXUS_HVBAT_C19_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #20 voltage LEXUS_HVBAT_C20_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #21 voltage LEXUS_HVBAT_C21_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #22 voltage LEXUS_HVBAT_C22_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #23 voltage LEXUS_HVBAT_C23_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #24 voltage LEXUS_HVBAT_C24_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #25 voltage LEXUS_HVBAT_C25_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #26 voltage LEXUS_HVBAT_C26_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #27 voltage LEXUS_HVBAT_C27_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #28 voltage LEXUS_HVBAT_C28_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #29 voltage LEXUS_HVBAT_C29_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #30 voltage LEXUS_HVBAT_C30_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #31 voltage LEXUS_HVBAT_C31_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #32 voltage LEXUS_HVBAT_C32_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #33 voltage LEXUS_HVBAT_C33_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #34 voltage LEXUS_HVBAT_C34_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #35 voltage LEXUS_HVBAT_C35_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #36 voltage LEXUS_HVBAT_C36_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #37 voltage LEXUS_HVBAT_C37_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #38 voltage LEXUS_HVBAT_C38_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #39 voltage LEXUS_HVBAT_C39_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #40 voltage LEXUS_HVBAT_C40_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #41 voltage LEXUS_HVBAT_C41_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #42 voltage LEXUS_HVBAT_C42_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #43 voltage LEXUS_HVBAT_C43_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #44 voltage LEXUS_HVBAT_C44_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #45 voltage LEXUS_HVBAT_C45_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #46 voltage LEXUS_HVBAT_C46_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #47 voltage LEXUS_HVBAT_C47_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #48 voltage LEXUS_HVBAT_C48_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #49 voltage LEXUS_HVBAT_C49_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #50 voltage LEXUS_HVBAT_C50_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #51 voltage LEXUS_HVBAT_C51_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #52 voltage LEXUS_HVBAT_C52_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #53 voltage LEXUS_HVBAT_C53_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #54 voltage LEXUS_HVBAT_C54_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #55 voltage LEXUS_HVBAT_C55_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #56 voltage LEXUS_HVBAT_C56_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #57 voltage LEXUS_HVBAT_C57_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #58 voltage LEXUS_HVBAT_C58_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #59 voltage LEXUS_HVBAT_C59_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #60 voltage LEXUS_HVBAT_C60_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #61 voltage LEXUS_HVBAT_C61_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #62 voltage LEXUS_HVBAT_C62_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #63 voltage LEXUS_HVBAT_C63_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #64 voltage LEXUS_HVBAT_C64_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #65 voltage LEXUS_HVBAT_C65_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #66 voltage LEXUS_HVBAT_C66_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #67 voltage LEXUS_HVBAT_C67_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #68 voltage LEXUS_HVBAT_C68_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #69 voltage LEXUS_HVBAT_C69_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #70 voltage LEXUS_HVBAT_C70_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #71 voltage LEXUS_HVBAT_C71_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #72 voltage LEXUS_HVBAT_C72_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #73 voltage LEXUS_HVBAT_C73_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #74 voltage LEXUS_HVBAT_C74_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #75 voltage LEXUS_HVBAT_C75_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #76 voltage LEXUS_HVBAT_C76_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #77 voltage LEXUS_HVBAT_C77_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #78 voltage LEXUS_HVBAT_C78_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #79 voltage LEXUS_HVBAT_C79_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #80 voltage LEXUS_HVBAT_C80_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #81 voltage LEXUS_HVBAT_C81_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #82 voltage LEXUS_HVBAT_C82_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #83 voltage LEXUS_HVBAT_C83_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #84 voltage LEXUS_HVBAT_C84_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #85 voltage LEXUS_HVBAT_C85_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #86 voltage LEXUS_HVBAT_C86_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #87 voltage LEXUS_HVBAT_C87_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #88 voltage LEXUS_HVBAT_C88_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #89 voltage LEXUS_HVBAT_C89_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #90 voltage LEXUS_HVBAT_C90_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #91 voltage LEXUS_HVBAT_C91_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #92 voltage LEXUS_HVBAT_C92_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #93 voltage LEXUS_HVBAT_C93_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #94 voltage LEXUS_HVBAT_C94_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,488 to 1,503 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #95 voltage LEXUS_HVBAT_C95_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,504 to 1,519 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
HV battery cell #96 voltage LEXUS_HVBAT_C96_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 1,520 to 1,535 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Battery › Modules › 01
HV battery module 01 voltage LEXUS_HVBAT_CMU01_VOLT
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
In testing for 2003 to 2004, 2007 to 2009. Not supported for 2005 to 2006.
Battery › Modules › 02
HV battery module 02 voltage LEXUS_HVBAT_CMU02_VOLT
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V