Engine parameters
The Ford Bronco has 104 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2022 to 2023, 2026. Supported for 2021, 2024.
Actual engine percent torque BRONCO_PCM_ACT_ENG_PCT_TRQConfirmed
- Request
22 F4 62 - Service 22
DID F462 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x7D = 125 → (125 − 125) = 0 %
- Formula
(val − 125)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Actuator cam position corrected BRONCO_ACTUATOR_CAM_POS
- Request
22 01 7C - Service 22
DID 017C - Module
703 → 70B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023 °
- Unit
- °
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Actuator duty cycle output, commanded BRONCO_ACTUATOR_DUTY_OUTPUT_CMD
- Request
22 01 7F - Service 22
DID 017F - Module
703 → 70B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 1953 ÷ 500000)- Range
- -127 to 127 %
- Unit
- %
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Air conditioning pressure BRONCO_AC_P_7E0Confirmed
- Request
22 FD 18 - Service 22
DID FD18 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 12.156863) = 0 kPa
- Formula
(val × 12.156863)- Range
- 0 to 3100 kPa
- Unit
- kPa
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Barometric pressure BRONCO_BAROMETRIC_P
- Request
22 11 27 - Service 22
DID 1127 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 338639 ÷ 80000)- Range
- 0 to 1079.4118 kPa
- Unit
- kPa
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Battery current BRONCO_BAT_CURRENT_726
- Request
22 40 90 - Service 22
DID 4090 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 511.7)- Range
- -511.7 to 3584.2375 A
- Unit
- A
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Boost BRONCO_BOOST
- Request
22 14 40 - Service 22
DID 1440 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 psi
- Unit
- psi
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Bypass valve BRONCO_BPV_OPENConfirmed
- Request
22 04 27 - Service 22
DID 0427 - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 255) = 0
- Formula
(val ÷ 255)- Range
- 0 to 1
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023, 2026. Supported for 2021 to 2022, 2024 to 2025.
Catalyst temperature BRONCO_CAT_TEMPConfirmed
- Request
22 F4 3C - Service 22
DID F43C - Module
7E0 → 7E8 - Every
5 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x1366 = 4966 → (4966 ÷ 10 − 40) = 456.6 °C
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Charge air temperature BRONCO_CATConfirmed
- Request
22 04 61 - Service 22
DID 0461 - Module
7E0 → 7E8 - Every
5 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x080E = 2062 → (2062 ÷ 64 − 40) = -7.78125 °C
- Formula
(val ÷ 64 − 40)- Range
- -40 to 189 °C
- Unit
- °C
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Charge air temperature sensor voltage BRONCO_CAT_SENS_V
- Request
22 04 60 - Service 22
DID 0460 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 1024)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2022 to 2023, 2026. Supported for 2021, 2024.
Commanded generator duty BRONCO_CMD_GEN_DUTY
- Request
22 16 E8 - Service 22
DID 16E8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.003052)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Current gear BRONCO_GEARConfirmed
The automatic transmission gear.
- Request
22 1E 12 - Service 22
DID 1E12 - Module
7E0 → 7E8 - Every
2 s - Testing for 1988 to 1996
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | 1 | First gear |
2 | 2 | Second gear |
3 | 3 | Third gear |
4 | 4 | Fourth gear |
5 | 5 | Fifth gear |
6 | 6 | Sixth gear |
7 | 7 | Seventh gear |
8 | 8 | Eighth gear |
9 | 9 | Ninth gear |
10 | 10 | Tenth gear |
Confirmed for 2021 to 2026. In testing for 1988 to 1996.
Cylinder 1 misfire count BRONCO_MIS_CNT_1
- Request
22 16 0E - Service 22
DID 160E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Cylinder 2 misfire count BRONCO_MIS_CNT_2
- Request
22 16 0F - Service 22
DID 160F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Cylinder 3 misfire count BRONCO_MIS_CNT_3
- Request
22 16 10 - Service 22
DID 1610 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Cylinder 4 misfire count BRONCO_MIS_CNT_4
- Request
22 16 11 - Service 22
DID 1611 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Cylinder 5 misfire count BRONCO_MIS_CNT_5
- Request
22 16 12 - Service 22
DID 1612 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Cylinder 6 misfire count BRONCO_MIS_CNT_6
- Request
22 16 13 - Service 22
DID 1613 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Cylinder head temperature BRONCO_CYL_HEAD_T
- Request
22 05 1D - Service 22
DID 051D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Cylinder head temperature BRONCO_CYL_HEAD_T_7E0
- Request
22 16 24 - Service 22
DID 1624 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °F
- Unit
- °F
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Cylinder head temperature BRONCO_PCM_CYL_HEAD_T_CORRConfirmed
- Request
22 03 34 - Service 22
DID 0334 - Module
7E0 → 7E8 - Every
5 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0F98 = 3992 → (3992 ÷ 64) = 62.375 °C
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Cylinder head temperature, alternate BRONCO_CYL_HEAD_T_ALT
- Request
22 16 85 - Service 22
DID 1685 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 281 ÷ 1000)- Range
- 0 to 18415 °F
- Unit
- °F
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Cylinder head temperature, sensor 2 BRONCO_PCM_CYL_HEAD_T_SENS_2_RAWConfirmed
- Request
22 05 FC - Service 22
DID 05FC - Module
7E0 → 7E8 - Every
2 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x11F0 = 4592 → (4592 ÷ 64) = 71.75 °C
- Formula
(val ÷ 64)- Range
- -512 to 511.9843 °C
- Unit
- °C
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Distance since DTC clear BRONCO_DIST_DTC_CLRConfirmed
Pelican can show this parameter as the distance since trouble codes were cleared.
- Request
22 F4 31 - Service 22
DID F431 - Module
7E0 → 7E8 - Every
60 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x12CD = 4813 → 4,813 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Distance with MIL BRONCO_MIL_DISTConfirmed
- Request
22 F4 21 - Service 22
DID F421 - Module
7E0 → 7E8 - Every
60 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → 0 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022 to 2024, 2026. Supported for 2021, 2025.
Engine load BRONCO_ENG_LOAD_PCTConfirmed
Pelican can show this parameter as the engine load.
- Request
22 F4 04 - Service 22
DID F404 - Module
7E0 → 7E8 - Every
500 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 100 ÷ 255) = 0 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Engine load, actual BRONCO_ENG_LOAD_ACTConfirmed
Pelican can show this parameter as the engine load.
- Request
22 F4 43 - Service 22
DID F443 - Module
7E0 → 7E8 - Every
500 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 100 ÷ 255) = 0 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Engine oil temperature BRONCO_EOT_7E0
- Request
22 13 10 - Service 22
DID 1310 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 40)- Range
- -40 to 615 °C
- Unit
- °C
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Engine oil temperature, alternate BRONCO_EOT_F45C
Pelican can show this parameter as the engine oil temperature.
- Request
22 F4 5C - Service 22
DID F45C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Engine reference torque BRONCO_PCM_ENG_REFERENCE_TRQConfirmed
- Request
22 F4 63 - Service 22
DID F463 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x02AA = 682 → 682 N·m
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2022 to 2023, 2026. Supported for 2021, 2024 to 2025.
Engine run time BRONCO_ERT
- Request
22 11 26 - Service 22
DID 1126 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 s
- Unit
- s
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Engine speed BRONCO_RPMConfirmed
- Request
22 F4 0C - Service 22
DID F40C - Module
7E0 → 7E8 - Every
100 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 ÷ 4) = 0 rpm
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Evaporative purge BRONCO_EVAP_PURGE_CMDConfirmed
- Request
22 11 66 - Service 22
DID 1166 - Module
7E0 → 7E8 - Every
500 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 100 ÷ 32768) = 0 %
- Formula
(val × 100 ÷ 32768)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Exhaust gas recirculation BRONCO_EGR
- Request
22 F4 2C - Service 22
DID F42C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Exhaust gas recirculation duty cycle BRONCO_EGR_DUTY
- Request
22 11 3C - Service 22
DID 113C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Exhaust gas temperature 1 BRONCO_EXH_GAS_T_1
- Request
22 03 F4 - Service 22
DID 03F4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5)- Range
- 0 to 1275 °C
- Unit
- °C
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Exhaust gas temperature 2 BRONCO_EXH_GAS_T_2
- Request
22 03 F5 - Service 22
DID 03F5 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5)- Range
- 0 to 1275 °C
- Unit
- °C
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Fuel pressure sensor voltage, low BRONCO_LPFP_SENS_VConfirmed
- Request
22 05 4D - Service 22
DID 054D - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x07B7 = 1975 → (1975 ÷ 1024) = 1.928711 V
- Formula
(val ÷ 1024)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Fuel pressure, low actual BRONCO_LPFP_ACTConfirmed
- Request
22 05 48 - Service 22
DID 0548 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0394 = 916 → (916 × 10000 ÷ 137892) = 66.428799 psi
- Formula
(val × 10000 ÷ 137892)- Range
- 0 to 200 psi
- Unit
- psi
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Fuel pressure, low desired BRONCO_LPFP_DESConfirmed
- Request
22 04 1F - Service 22
DID 041F - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x9F = 159 → (159 × 435 ÷ 1000) = 69.165 psi
- Formula
(val × 435 ÷ 1000)- Range
- 0 to 110 psi
- Unit
- psi
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Fuel pump pulse width, bank 1 BRONCO_FUEL_PMP_WIDTH_BANK_1
- Request
22 11 41 - Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107
- Unit
- Number
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Fuel pump pulse width, bank 2 BRONCO_FUEL_PMP_WIDTH_BANK_2
- Request
22 11 42 - Service 22
DID 1142 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107
- Unit
- Number
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Fuel trim, long term BRONCO_LTFTConfirmed
- Request
22 F4 07 - Service 22
DID F407 - Module
7E0 → 7E8 - Every
500 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x7C = 124 → (124 × 100 ÷ 128 − 100) = -3.125 %
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Fuel trim, short term BRONCO_STFTConfirmed
Pelican can show this parameter as the short term fuel trim.
- Request
22 F4 06 - Service 22
DID F406 - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x6D = 109 → (109 × 100 ÷ 128 − 100) = -14.84375 %
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Generator control BRONCO_GEN_CTRL
- Request
22 03 78 - Service 22
DID 0378 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.003052)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Generator current BRONCO_GEN_CURRENTConfirmed
- Request
22 04 F7 - Service 22
DID 04F7 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0xF880 = -1920 → (-1920 × 781 ÷ 50000) = -29.9904 A
- Formula
(val × 781 ÷ 50000)- Range
- -511.8361 to 511.8205 A
- Unit
- A
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Grill shutter duty cycle BRONCO_GRILL_SHUT_DCConfirmed
- Request
22 07 07 - Service 22
DID 0707 - Module
7E0 → 7E8 - Every
5 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 100 ÷ 255) = 0 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Grill shutter position BRONCO_GRILL_SHUTTER_POSConfirmed
- Request
22 05 80 - Service 22
DID 0580 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 × 100 ÷ 255) = 0 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Hydraulic pump motor current BRONCO_HYDRAULIC_PMP_MOTOR
- Request
22 D0 0F - Service 22
DID D00F - Module
703 → 70B - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 A
- Unit
- A
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Ignition correction, cylinder 1 BRONCO_IGN_CORR_CYL1Confirmed
- Request
22 03 EC - Service 22
DID 03EC - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 512) = 0 °
- Formula
(val ÷ 512)- Range
- -64 to 63.9 °
- Unit
- °
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Ignition timing, cylinder 1 BRONCO_IGN_TIM_CYL1Confirmed
- Request
22 11 6B - Service 22
DID 116B - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0001 = 1 → (1 ÷ 4) = 0.25 °
- Formula
(val ÷ 4)- Range
- -80 to 80 °
- Unit
- °
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
In car temperature BRONCO_CAR_T
- Request
22 DD 04 - Service 22
DID DD04 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 8)- Range
- 0 to 31.875 °C
- Unit
- °C
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Injection mode BRONCO_INJ_MODEConfirmed
- Request
22 04 6F - Service 22
DID 046F - Module
7E0 → 7E8 - Every
2 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x07 = 7 → 7
- Formula
val- Range
- 0 to 7
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024. Supported for 2021 to 2023, 2025 to 2026.
Intake air temperature 2 BRONCO_IAT_2
- Request
22 16 A8 - Service 22
DID 16A8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 5 ÷ 9 − 17.777778)- Range
- -17.77 to 36390 °C
- Unit
- °C
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Intake temperature fault BRONCO_IAT_FAULTConfirmed
- Request
22 07 00 - Service 22
DID 0700 - Module
7E0 → 7E8 - Every
5 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Intake temperature sensor voltage BRONCO_IAT_SENS_VConfirmed
- Request
22 12 79 - Service 22
DID 1279 - Module
7E0 → 7E8 - Every
5 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x00FD = 253 → (253 × 5 ÷ 1023) = 1.236559 V
- Formula
(val × 5 ÷ 1023)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Intake temperature, alternate BRONCO_IAT_ALT2Confirmed
- Request
22 F4 0F - Service 22
DID F40F - Module
7E0 → 7E8 - Every
5 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x47 = 71 → (71 − 40) = 31 °C
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Knock counter, cylinder 1 BRONCO_PCM_CYL_1_KNK_COMB_PERF_CNTConfirmed
- Request
22 05 AC - Service 22
DID 05AC - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Knock counter, cylinder 2 BRONCO_PCM_CYL_2_KNK_COMB_PERF_CNTConfirmed
- Request
22 05 AD - Service 22
DID 05AD - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Knock counter, cylinder 3 BRONCO_PCM_CYL_3_KNK_COMB_PERF_CNTConfirmed
- Request
22 05 AE - Service 22
DID 05AE - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Knock counter, cylinder 4 BRONCO_PCM_CYL_4_KNK_COMB_PERF_CNTConfirmed
- Request
22 05 AF - Service 22
DID 05AF - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x02 = 2 → 2
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Knock counter, cylinder 5 BRONCO_PCM_CYL_5_KNK_COMB_PERF_CNTConfirmed
- Request
22 05 B0 - Service 22
DID 05B0 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Knock counter, cylinder 6 BRONCO_PCM_CYL_6_KNK_COMB_PERF_CNTConfirmed
- Request
22 05 B1 - Service 22
DID 05B1 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Knock sensor, 1 BRONCO_KS1_RAWConfirmed
- Request
22 04 03 - Service 22
DID 0403 - Module
7E0 → 7E8 - Every
2 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x0013 = 19 → 19
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Knock sensor, 2 BRONCO_KS2_RAWConfirmed
- Request
22 04 04 - Service 22
DID 0404 - Module
7E0 → 7E8 - Every
2 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x0010 = 16 → 16
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Manifold absolute pressure, high resolution BRONCO_MAP_HIRESConfirmed
- Request
22 03 70 - Service 22
DID 0370 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x0055 = 85 → (85 ÷ 4) = 21.25 kPa
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 kPa
- Unit
- kPa
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Manifold pressure BRONCO_MAPConfirmed
- Request
22 F4 0B - Service 22
DID F40B - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x14 = 20 → (20 × 10000 ÷ 68947) = 2.900779 psi
- Formula
(val × 10000 ÷ 68947)- Range
- 0 to 36 psi
- Unit
- psi
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Misfire acceleration, cylinder 1 BRONCO_PCM_MISF_ACCEL_CYL1_NORMConfirmed
- Request
22 03 82 - Service 22
DID 0382 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 64) = 0
- Formula
(val ÷ 64)- Range
- -2 to 1.98
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Misfire acceleration, cylinder 2 BRONCO_PCM_MISF_ACCEL_CYL2_NORMConfirmed
- Request
22 03 88 - Service 22
DID 0388 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 64) = 0
- Formula
(val ÷ 64)- Range
- -2 to 1.98
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Misfire acceleration, cylinder 3 BRONCO_PCM_MISF_ACCEL_CYL3_NORMConfirmed
- Request
22 03 8A - Service 22
DID 038A - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 64) = 0
- Formula
(val ÷ 64)- Range
- -2 to 1.98
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Misfire acceleration, cylinder 4 BRONCO_PCM_MISF_ACCEL_CYL4_NORMConfirmed
- Request
22 03 8B - Service 22
DID 038B - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 64) = 0
- Formula
(val ÷ 64)- Range
- -2 to 1.98
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Misfire acceleration, cylinder 5 BRONCO_PCM_MISF_ACCEL_CYL5_NORMConfirmed
- Request
22 03 8C - Service 22
DID 038C - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 64) = 0
- Formula
(val ÷ 64)- Range
- -2 to 1.98
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Misfire acceleration, cylinder 6 BRONCO_PCM_MISF_ACCEL_CYL6_NORMConfirmed
- Request
22 03 98 - Service 22
DID 0398 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 64) = 0
- Formula
(val ÷ 64)- Range
- -2 to 1.98
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Misfire events, latest cycle BRONCO_PCM_MISF_EVENTS_LATEST_CYCConfirmed
- Request
22 03 45 - Service 22
DID 0345 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 31 of the reply, 32 bits.
0x00000002 = 2 → 2
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Oil life remaining BRONCO_PCM_ENG_OIL_LIFE_REMConfirmed
- Request
22 05 4B - Service 22
DID 054B - Module
7E0 → 7E8 - Every
5 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x20 = 32 → 32 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Oil pressure BRONCO_PCM_ENG_EOP_RAWConfirmed
- Request
22 04 15 - Service 22
DID 0415 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0063 = 99 → 99 kPa
- Formula
val- Range
- -32768 to 32767 kPa
- Unit
- kPa
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Power transfer unit sump temperature BRONCO_POWER_TRANSFER_UNIT_T
- Request
22 01 84 - Service 22
DID 0184 - Module
703 → 70B - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 °C
- Unit
- °C
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Power transfer unit, requested torque BRONCO_POWER_TRANSFER_UNIT_REQ_TQ
- Request
22 01 82 - Service 22
DID 0182 - Module
703 → 70B - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Power transfer unit, requested torque capacity inferred BRONCO_POWER_TRANSFER_UNIT_REQ_TQ_CAP
- Request
22 01 85 - Service 22
DID 0185 - Module
703 → 70B - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Shift gear BRONCO_GEAR_SHFT
- Request
22 1E 23 - Service 22
DID 1E23 - Module
7E0 → 7E8 - Every
2 s - Testing for 1988 to 1996
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
10 | MANUAL | Manual |
46 | DRIVE | Drive |
50 | NEUTRAL | Neutral |
60 | REVERSE | Reverse |
70 | PARK | Park |
In testing for 1988 to 1996. Supported for 2021 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2023, 2026. Supported for 2021 to 2022, 2024 to 2025.
Sump oil temperature measured BRONCO_SUMP_OIL_T_MEAS
- Request
22 03 F3 - Service 22
DID 03F3 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Throttle angle, actual BRONCO_ETC_ANG_ACTConfirmed
- Request
22 09 3C - Service 22
DID 093C - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x0290 = 656 → (656 ÷ 512) = 1.28125 °
- Formula
(val ÷ 512)- Range
- 0 to 127.99 °
- Unit
- °
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Throttle angle, desired BRONCO_ETC_ANG_DESConfirmed
- Request
22 09 1A - Service 22
DID 091A - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512)- Range
- 0 to 127.99 °
- Unit
- °
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Throttle inlet pressure, desired BRONCO_TIP_DES_ABSConfirmed
- Request
22 04 66 - Service 22
DID 0466 - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x324D = 12877 → (12877 × 37 ÷ 33441) = 14.247451 psi
- Formula
(val × 37 ÷ 33441)- Range
- 0 to 72.5 psi
- Unit
- psi
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Time since last oil change BRONCO_TIME_SINCE_OIL
- Request
22 05 3F - Service 22
DID 053F - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 200 ÷ 13107)- Range
- 0 to 1000
- Unit
- Raw value
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Torque request BRONCO_TRQ_CTRL_REQConfirmed
- Request
22 03 AF - Service 22
DID 03AF - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → 0 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Total misfire count BRONCO_TOT_MIS_CNT
- Request
22 16 16 - Service 22
DID 1616 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Transfer case fluid temperature BRONCO_TRANSFER_CASE_FLUID_T
- Request
22 07 0D - Service 22
DID 070D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.9375 °C
- Unit
- °C
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Transmission oil temperature BRONCO_TOTConfirmed
- Request
22 1E 1C - Service 22
DID 1E1C - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 1996
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0206 = 518 → (518 ÷ 16) = 32.375 °C
- Formula
(val ÷ 16)- Range
- -500 to 500 °C
- Unit
- °C
Confirmed for 2021 to 2026. In testing for 1988 to 1996.
Turbo boost BRONCO_TURBO_BOOST
- Request
22 09 DB - Service 22
DID 09DB - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Turbo inlet pressure BRONCO_TURBO_INLET_P
- Request
22 05 BE - Service 22
DID 05BE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095.9375 kPa
- Unit
- kPa
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Warm-ups since DTC clear BRONCO_WARMUP_CLRConfirmed
- Request
22 F4 30 - Service 22
DID F430 - Module
7E0 → 7E8 - Every
60 s - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 7 of the reply, 8 bits.
0x93 = 147 → 147
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Wastegate control BRONCO_WASTEGATE_CTRL
- Request
22 16 E1 - Service 22
DID 16E1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 763 ÷ 50000)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1996, 2021, 2024 to 2025. Not supported for 2022 to 2023, 2026.
Wastegate duty cycle BRONCO_WGDCConfirmed
- Request
22 04 62 - Service 22
DID 0462 - Module
7E0 → 7E8 - Every
250 ms - Testing for 1988 to 1996, 2021, 2024 to 2025
Example reply from a 2026 Ford Bronco.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 100 ÷ 32768) = 0 %
- Formula
(val × 100 ÷ 32768)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.
Engine › OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2023, 2026. Supported for 2021 to 2022, 2024 to 2025.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2023, 2026. Supported for 2021 to 2022, 2024 to 2025.