Ford Bronco

Climate parameters

The Ford Bronco has 5 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor, state BRONCO_AC_STATEConfirmed

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 1996, 2021, 2024 to 2025

Example reply from a 2026 Ford Bronco.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor pressure sensor voltage BRONCO_AC_P_SENS_VConfirmed

  • Request22 98 00
  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 1988 to 1996, 2021, 2024 to 2025

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.

A/C compressor, state BRONCO_AC_STATEConfirmed

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 1996, 2021, 2024 to 2025

Example reply from a 2026 Ford Bronco.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.

A/C refrigerant pressure BRONCO_PCM_A_C_REFRIG_PConfirmed

  • Request22 06 04
  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 1996, 2021, 2024 to 2025

Example reply from a 2026 Ford Bronco.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x033F = 831 → 831 kPa

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2023. Supported for 2021, 2024.

Ambient temperature, alternate BRONCO_AAT_ALTConfirmed

  • Request22 05 7D
  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 1996, 2021, 2024 to 2025

Example reply from a 2026 Ford Bronco.

Bits 0 to 7 of the reply, 8 bits.

0x8A = 138 → (138 ÷ 2 − 40) = 29 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2022 to 2023, 2026. In testing for 1988 to 1996, 2021, 2024 to 2025.