Audi A7

Engine parameters

The Audi A7 has 489 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Air mass meter 1 A7_MQB_AIR_MASS_1Confirmed

  • Request22 10 24
  • Service 22DID 1024
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x01B5 = 437 → (437 × 1000 ÷ 10000) = 43.7

Formula
(val × 1000 ÷ 10000)
Range
-3276.8 to 3276.7
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2020. Supported for 2021.

Adaptive mode A7_ADAPTIVE_MODE

  • Request22 10 11
  • Service 22DID 1011
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Air conditioning compressor pressure A7_AC_COMP_P

  • Request22 10 17
  • Service 22DID 1017
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2)
Range
0 to 131070
Unit
Raw value

In testing for 2019 to 2026.

Air conditioning compressor pressure, linear raw value A7_AC_COMP_P_LINEAR_RAW

  • Request22 15 C7
  • Service 22DID 15C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2)
Range
0 to 131070
Unit
Raw value

In testing for 2019 to 2026.

Air conditioning compressor refrigerant pressure A7_AC_COMP_REFRIGERANT_P

  • Request22 10 48
  • Service 22DID 1048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 2)
Range
-65536 to 65534
Unit
Raw value

In testing for 2019 to 2026.

Air conditioning compressor torque A7_AC_COMP_TQ

  • Request22 10 1A
  • Service 22DID 101A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2019 to 2026.

Air conditioning compressor torque request A7_AC_COMP_TQ_REQ

  • Request22 10 23
  • Service 22DID 1023
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2019 to 2026.

Air conditioning refrigerant pressure A7_AC_REFRIGERANT_P

  • Request22 41 2A
  • Service 22DID 412A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 2)
Range
-65536 to 65534
Unit
Raw value

In testing for 2019 to 2026.

Air filling A7_AIR_FILLING

  • Request22 12 1C
  • Service 22DID 121C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 11719 ÷ 500000)
Range
0 to 1536 %
Unit
%

In testing for 2019 to 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2012. Supported for 2016.

Air leakage A7_AIR_LEAKAGE

  • Request22 11 B8
  • Service 22DID 11B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Raw value

In testing for 2019 to 2026.

Air mass A7_AIR_MASS

  • Request22 13 CD
  • Service 22DID 13CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047
Unit
Raw value

In testing for 2010 to 2018.

Air mass meter 1 A7_MQB_AIR_MASS_1Confirmed

  • Request22 10 24
  • Service 22DID 1024
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x01B5 = 437 → (437 × 1000 ÷ 10000) = 43.7

Formula
(val × 1000 ÷ 10000)
Range
-3276.8 to 3276.7
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Air mass, specified value A7_AIR_MASS_SPEC

  • Request22 10 4C
  • Service 22DID 104C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276
Unit
Raw value

In testing for 2010 to 2018.

Ambient air temperature, v1 A7_AAT_V1Confirmed

  • Request22 14 F8
  • Service 22DID 14F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0ACE = 2766 → (2766 × 0.18 − 460) = 37.88 °F

Formula
(val × 0.18 − 460)
Range
-460 to 11336.3 °F
Unit
°F

Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.

Ambient temperature A7_AAT_7E0

  • Request22 10 00
  • Service 22DID 1000
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2010 to 2018.

Ambient temperature A7_AAT_7E0_2

  • Request22 11 23
  • Service 22DID 1123
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2019 to 2026.

Aux. hydraulic pump internal temperature A7_AUX_HYDRAULIC_PMP_T

  • Request22 51 A6
  • Service 22DID 51A6
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Aux. hydraulic pump, current A7_AUX_HYDRAULIC_PMP

  • Request22 4E 76
  • Service 22DID 4E76
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 A
Unit
A

In testing for 2019 to 2026.

Barometric pressure A7_BAROMETRIC_P

  • Request22 15 09
  • Service 22DID 1509
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262 kPa
Unit
kPa

In testing for 2019 to 2026.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2020. Supported for 2012, 2016, 2021.

Boost pressure commanded A7_PQ35_BOOST_P_CMDConfirmed

  • Request22 11 49
  • Service 22DID 1149
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → 0

Formula
val
Range
-32768 to 32767
Unit
Raw value

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Boost pressure sensor A BP_A_ACTSAE J1979Confirmed

Actual turbocharger/supercharger A boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2020.

Boost pressure sensor B BP_B_ACTSAE J1979Confirmed

Actual turbocharger/supercharger B boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2020.

Boost pressure, actual A7_BOOST_P_ACT

  • Request22 11 F0
  • Service 22DID 11F0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 5119
Unit
Raw value

In testing for 2019 to 2026.

Boost regulator feedback A7_BOOST_REGULATOR_FEEDBACKConfirmed

  • Request22 11 CC
  • Service 22DID 11CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x184C = 6220 → (6220 ÷ 100) = 62.2 %

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Break pressure A7_BREAK_P

  • Request22 2B 21
  • Service 22DID 2B21
  • Module713 → 77D
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 152999 ÷ 10000000 − 42.503)
Range
-543 to 458 bar
Unit
bar

In testing for 2019 to 2026.

Bypass valve high pressure turbine inlet, activation A7_BYPASS_VLV_HIGH_P

  • Request22 39 FF
  • Service 22DID 39FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2019 to 2026.

Bypass valve high pressure turbine inlet, actual value A7_BYPASS_VLV_HIGH_P_ACT

  • Request22 39 FC
  • Service 22DID 39FC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 25 ÷ 2048)
Range
-400 to 399 %
Unit
%

In testing for 2019 to 2026.

Bypass valve high pressure turbine inlet, offset closed A7_BYPASS_VLV_HIGH_P_TURBINE

  • Request22 39 FD
  • Service 22DID 39FD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.012207)
Range
-399 to 399 %
Unit
%

In testing for 2019 to 2026.

Bypass valve high pressure turbine inlet, offset open A7_BYPASS_VLV_HIGH_P_TURBINE_INLET

  • Request22 39 FE
  • Service 22DID 39FE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.012207)
Range
-399 to 399 %
Unit
%

In testing for 2019 to 2026.

Bypass valve high pressure turbine inlet, target value A7_BYPASS_VLV_HIGH_P_TGT

  • Request22 39 FB
  • Service 22DID 39FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 25 ÷ 2048)
Range
-400 to 399 %
Unit
%

In testing for 2019 to 2026.

Bze_q_elad A7_BZE_Q_ELAD

  • Request22 12 3A
  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 32 to 63 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2019 to 2026.

Bze_q_lad A7_BZE_Q_LAD

  • Request22 12 3A
  • Service 22DID 123A
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729 Ah
Unit
Ah

In testing for 2019 to 2026.

Cabin temperature A7_C7_CABIN_TConfirmed

  • Request22 26 13
  • Service 22DID 2613
  • Module746 → 7B0
  • Every5 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x12D5 = 4821 → (4821 ÷ 256) = 18.832031 °C

Formula
(val ÷ 256)
Range
-128 to 127.99 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2018. Not supported for 2020.

Cabin temperature A7_CABIN_T

  • Request22 26 13
  • Service 22DID 2613
  • Module746 → 7B0
  • Every5 s

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 100 °C
Unit
°C

Supported for 2011 to 2012. Not supported for 2020.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2012, 2020. Supported for 2016, 2021.

Camshaft adaptation exhaust bank 1, phase position A7_CAM_ADPT_EXH_BANK_1

  • Request22 11 28
  • Service 22DID 1128
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720 to 719 °
Unit
°

In testing for 2010 to 2018.

Camshaft adaptation intake bank 1, phase position A7_CAM_ADPT_INT_BANK_1

  • Request22 11 25
  • Service 22DID 1125
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720 to 719 °
Unit
°

In testing for 2010 to 2018.

Camshaft adaptation, counter due to knock A7_CAM_ADPT_CNT_KNOCK

  • Request22 52 3B
  • Service 22DID 523B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Camshaft adaptation, intake deviation A7_CAM_ADPT_INT_DEV

  • Request22 4F F5
  • Service 22DID 4FF5
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

In testing for 2019 to 2026.

Camshaft adjustment, exhaust bank 1, actual value A7_CAM_ADJ_EXH_BANK_1_ACT

  • Request22 13 6C
  • Service 22DID 136C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511 °
Unit
°

In testing for 2019 to 2026.

Camshaft adjustment, exhaust bank 1, specified value A7_CAM_ADJ_EXH_BANK_1_SPEC

  • Request22 13 71
  • Service 22DID 1371
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 125)
Range
-262 to 262 °
Unit
°

In testing for 2019 to 2026.

Camshaft adjustment, exhaust bank 2, actual value A7_CAM_ADJ_EXH_BANK_2_ACT

  • Request22 13 6D
  • Service 22DID 136D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511 °
Unit
°

In testing for 2019 to 2026.

Camshaft adjustment, exhaust bank 2, specified value A7_CAM_ADJ_EXH_BANK_2_SPEC

  • Request22 13 72
  • Service 22DID 1372
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 125)
Range
-262 to 262 °
Unit
°

In testing for 2019 to 2026.

Camshaft adjustment, intake bank 1, actual value A7_CAM_ADJ_INT_BANK_1_ACT

  • Request22 13 6E
  • Service 22DID 136E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511 °
Unit
°

In testing for 2019 to 2026.

Camshaft adjustment, intake bank 1, specified value A7_CAM_ADJ_INT_BANK_1_SPEC

  • Request22 13 73
  • Service 22DID 1373
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 125)
Range
-262 to 262 °
Unit
°

In testing for 2019 to 2026.

Camshaft end position A7_PQ35_CAMS_ENDConfirmed

  • Request22 13 41
  • Service 22DID 1341
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x00C3 = 195 → (195 ÷ 5) = 39 °

Formula
(val ÷ 5)
Range
-6553.6 to 6553.4 °
Unit
°

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Camshaft position, deviation from the base position A7_CAM_POS_DEV_BASE_POS

  • Request22 13 85
  • Service 22DID 1385
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720 to 719 °
Unit
°

In testing for 2019 to 2026.

Camshaft start position A7_PQ35_CAMS_STARTConfirmed

  • Request22 10 07
  • Service 22DID 1007
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x20CF = 8399 → (8399 ÷ 5) = 1,679.8 °

Formula
(val ÷ 5)
Range
-6553.6 to 6553.4 °
Unit
°

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Cat. temperature, bank 1 A7_CAT_T_BANK_1

  • Request22 12 98
  • Service 22DID 1298
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 273.15)
Range
-273 to 3822 °C
Unit
°C

In testing for 2010 to 2018.

Cat. temperature, bank 2 A7_CAT_T_BANK_2

  • Request22 12 99
  • Service 22DID 1299
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 273.15)
Range
-273 to 3822 °C
Unit
°C

In testing for 2010 to 2018.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2020. Supported for 2016, 2021.

Catalyst temperature, calculated A7_CAT_T_CALC

  • Request22 15 15
  • Service 22DID 1515
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 5 − 50)
Range
-50 to 1225 °C
Unit
°C

In testing for 2019 to 2026.

Charge air cooler downstream air pressure A7_AIR_P_CAC_DS

  • Request22 10 56
  • Service 22DID 1056
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2019 to 2026.

Clutch #1 maximum temperature A7_PQ35_CLUTCH_1_MAXIMUM_T

  • Request22 11 18
  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2010, 2013 to 2019, 2021 to 2026. Supported for 2011 to 2012. Not supported for 2020.

Clutch #2 maximum temperature A7_PQ35_CLUTCH_2_MAXIMUM_T

  • Request22 11 18
  • Service 22DID 1118
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Bits 16 to 31 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535 °C
Unit
°C

In testing for 2010, 2013 to 2019, 2021 to 2026. Supported for 2011 to 2012. Not supported for 2020.

Clutch 0 temperature calculated A7_C7_CLUTCH_0_T_CALCULATEDConfirmed

  • Request22 12 0F
  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2010, 2013 to 2017

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x02BC = 700 → (700 ÷ 10) = 70 °C

Formula
(val ÷ 10)
Range
-40 to 600 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2017.

Clutch 0 temperature calculated A7_MQB_DL382_CLUTCH_0_T_CALCULATEDConfirmed

  • Request22 12 0F
  • Service 22DID 120F
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0026 = 38 → 38 °C

Formula
val
Range
-40 to 600 °C
Unit
°C

Confirmed for 2020. In testing for 2021 to 2026.

Clutch 1 temperature A7_PQ35_CLUTCH_1_TConfirmed

  • Request22 10 2B
  • Service 22DID 102B
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0 °C

Formula
val
Range
0 to 255 °C
Unit
°C

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Clutch 2 temperature A7_PQ35_CLUTCH_2_TConfirmed

  • Request22 10 2C
  • Service 22DID 102C
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0 °C

Formula
val
Range
0 to 255 °C
Unit
°C

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Clutch temperature calculated A7_MQB_DL382_CLUTCH_T_CALCULATEDConfirmed

  • Request22 18 E3
  • Service 22DID 18E3
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0045 = 69 → 69 °C

Formula
val
Range
-32768 to 32767 °C
Unit
°C

Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.

Commanded boost pressure A BP_A_CMDSAE J1979Confirmed

Turbocharger/supercharger A commanded boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2020.

Commanded boost pressure B BP_B_CMDSAE J1979Confirmed

Turbocharger/supercharger B commanded boost pressure.

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 55 of the reply, 16 bits.

Formula
(val ÷ 32)
Range
0 to 2047.96875 kPa
Unit
kPa

Confirmed for 2020.

Commanded crankshaft torque A7_CMD_CRANK_TQ

  • Request22 11 E0
  • Service 22DID 11E0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2019 to 2026.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2020. Supported for 2021.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Request01 2E
  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020. Supported for 2021.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020. Supported for 2012, 2016.

Compression test cylinder 1 A7_PQ35_COMPRESSION_TEST_CYL_1Confirmed

  • Request22 11 29
  • Service 22DID 1129
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 2) = 0 rpm

Formula
(val ÷ 2)
Range
-16384 to 16383.5 rpm
Unit
rpm

Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.

Compression test cylinder 2 A7_PQ35_COMP_TEST_CYL_2

  • Request22 11 2A
  • Service 22DID 112A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-16384 to 16383.5 rpm
Unit
rpm

In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.

Control module temperature A7_CTRL_MODULE_T

  • Request22 03 01
  • Service 22DID 0301
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2019 to 2026.

Control module temperature A7_ECU_TEMP

  • Request22 02 8D
  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

Not supported for 2011 to 2012, 2016.

Control module temperature A7_ECU_TEMP_KConfirmed

  • Request22 02 8D
  • Service 22DID 028D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0B79 = 2937 → (2937 ÷ 10 − 273.1) = 20.6 °C

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

Confirmed for 2020. In testing for 2019, 2021 to 2026.

Converter loss torque A7_MQB_TCM_CONVERTER_LOSS_TORQUEConfirmed

  • Request22 10 10
  • Service 22DID 1010
  • Module7E1 → 7E9
  • Every250 ms
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0046 = 70 → (70 ÷ 20) = 3.5 N·m

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35 N·m
Unit
N·m

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Coolant at engine start A7_CLT_ENG_START

  • Request22 12 91
  • Service 22DID 1291
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2019 to 2026.

Coolant circulation pump, control A7_CLT_CIRCULATION_PMP

  • Request22 16 7E
  • Service 22DID 167E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2019 to 2026.

Coolant fan 1 activation, $1117 A7_CLT_FAN_1_ACTIVATION_1117

  • Request22 11 17
  • Service 22DID 1117
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2019 to 2026.

Coolant fan 1 duty cycle A7_PQ35_COOL_FAN_1_DUTYConfirmed

  • Request22 11 16
  • Service 22DID 1116
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Coolant fan 2 duty cycle A7_PQ35_COOL_FAN_2_DUTYConfirmed

  • Request22 11 14
  • Service 22DID 1114
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x03E8 = 1000 → (1000 ÷ 100) = 10 %

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Coolant fan activation, actual value A7_CLT_FAN_ACTIVATION_ACT

  • Request22 26 06
  • Service 22DID 2606
  • Module70E → 778
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2019 to 2026.

Coolant fan activation, specified value A7_CLT_FAN_ACTIVATION_SPEC

  • Request22 26 07
  • Service 22DID 2607
  • Module70E → 778
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 %
Unit
%

In testing for 2019 to 2026.

Coolant fan, requested by A/C A7_CLT_FAN_REQ_AC

  • Request22 10 18
  • Service 22DID 1018
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 12207 ÷ 1000000)
Range
-399 to 399 %
Unit
%

In testing for 2019 to 2026.

Coolant temperature at engine outlet, calculated A7_ECT_ENG_OUTLET_CALC

  • Request22 10 64
  • Service 22DID 1064
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2019 to 2026.

Coolant temperature at radiator outlet A7_COOLANT_TConfirmed

  • Request22 11 35
  • Service 22DID 1135
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0EC3 = 3779 → (3779 ÷ 10 − 273.1) = 104.8 °C

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.

Coolant temperature at radiator outlet v.1 A7_ECT_RADIATOR_OUTLET_V_1

  • Request22 15 CD
  • Service 22DID 15CD
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2019 to 2026.

Cooling fan 1 A7_COOLING_FAN_1

  • Request22 11 30
  • Service 22DID 1130
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2019 to 2026.

Cooling fan 2 A7_COOLING_FAN_2

  • Request22 11 2E
  • Service 22DID 112E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2019 to 2026.

Correction factor of oil temperature for engine protection A7_CORR_FACTOR_OIL_T

  • Request22 3F 4F
  • Service 22DID 3F4F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 12207 ÷ 100000000)
Range
0 to 7.99
Unit
Number

In testing for 2019 to 2026.

Current N215 pressure control valve 1 A7_CURRENT_N215_P_CTRL_1

  • Request22 10 24
  • Service 22DID 1024
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2019 to 2026.

Current N216 pressure control valve 2 A7_CURRENT_N216_P_CTRL_2

  • Request22 10 26
  • Service 22DID 1026
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2019 to 2026.

Current N217 pressure control valve 3 A7_CURRENT_N217_P_CTRL_3

  • Request22 10 28
  • Service 22DID 1028
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2019 to 2026.

Current N218 pressure control valve 4 A7_CURRENT_N218_P_CTRL_4

  • Request22 10 25
  • Service 22DID 1025
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2019 to 2026.

Current N233 pressure control valve 5 A7_CURRENT_N233_P_CTRL_5

  • Request22 10 27
  • Service 22DID 1027
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2019 to 2026.

Current N443 pressure control valve 7 main pressure A7_CURRENT_N443_P_CTRL_7_P

  • Request22 10 2A
  • Service 22DID 102A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2019 to 2026.

Current solenoid A7_CURRENT_SOLENOID

  • Request22 10 37
  • Service 22DID 1037
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 mA
Unit
mA

In testing for 2019 to 2026.

Current type of driver counter A7_CURRENT_TYPE_DRIVER

  • Request22 10 13
  • Service 22DID 1013
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Cylinder head temperature, actual A7_CYL_HEAD_T_ACT

  • Request22 10 65
  • Service 22DID 1065
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2019 to 2026.

Desired torque filtered A7_DES_TQ_FILTERED

  • Request22 10 64
  • Service 22DID 1064
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2019 to 2026.

Desired torque raw A7_DES_TQ_RAW

  • Request22 10 61
  • Service 22DID 1061
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2019 to 2026.

Diesel particulate filter air pressure sensor, raw A7_MQB_DPF_AIR_P_SENSOR_RAW_VALUEConfirmed

  • Request22 16 2F
  • Service 22DID 162F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0007 = 7 → 7

Formula
val
Range
-32768 to 32767
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Diesel particulate filter ash load limit A7_DPF_ASH_LOAD_LIM

  • Request22 40 6B
  • Service 22DID 406B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2019 to 2026.

Diesel particulate filter counter for regeneration time A7_DPF_CNT_REGEN_TIME

  • Request22 39 F9
  • Service 22DID 39F9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 100)
Range
0 to 42949672 s
Unit
s

In testing for 2019 to 2026.

Diesel particulate filter differential pressure A7_DPF_DIFF_P

  • Request22 20 84
  • Service 22DID 2084
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2019 to 2026.

Diesel particulate filter differential pressure offset A7_PQ35_DPF_DIFF_P_OFFSETConfirmed

  • Request22 10 F1
  • Service 22DID 10F1
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0002 = 2 → 2

Formula
val
Range
-32768 to 32767
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Diesel particulate filter differential pressure raw value, bank 1 A7_DPF_DIFF_P_RAW_BANK_1

  • Request22 16 6B
  • Service 22DID 166B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2010 to 2018.

Diesel particulate filter differential pressure raw value, bank 2 A7_DPF_DIFF_P_RAW_BANK_2

  • Request22 16 6C
  • Service 22DID 166C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2010 to 2018.

Diesel particulate filter differential pressure variant 2 A7_PQ35_DPF_DIFF_P_2Confirmed

  • Request22 10 F3
  • Service 22DID 10F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0007 = 7 → 7

Formula
val
Range
-32768 to 32767
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Diesel particulate filter differential pressure, dynamic offset A7_MQB_DPF_DIFF_P_DYNAMIC_OFFSETConfirmed

  • Request22 15 B8
  • Service 22DID 15B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → 0

Formula
val
Range
-32768 to 32767
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Diesel particulate filter exhaust gas flow volume A7_MQB_DPF_EXH_VOLConfirmed

  • Request22 11 E6
  • Service 22DID 11E6
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 × 1000 ÷ 10000) = 0

Formula
(val × 1000 ÷ 10000)
Range
-3276.8 to 3276.7
Unit
Number

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Diesel particulate filter field regeneration, cancel conditions A7_DPF_FIELD_REGEN

  • Request22 29 F7
  • Service 22DID 29F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Diesel particulate filter field regeneration, lock status A7_DPF_FIELD_REGEN_LOCK

  • Request22 20 88
  • Service 22DID 2088
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Diesel particulate filter field regeneration, request status A7_DPF_FIELD_REGEN_REQ

  • Request22 20 87
  • Service 22DID 2087
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Diesel particulate filter inlet temperature A7_PQ35_DPF_IN_TConfirmed

  • Request22 11 B2
  • Service 22DID 11B2
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x1166 = 4454 → (4454 ÷ 10 − 273.1) = 172.3 °C

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Diesel particulate filter offset for differential pressure A7_DPF_OFFSET_DIFF_P

  • Request22 20 85
  • Service 22DID 2085
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2019 to 2026.

Diesel particulate filter oil ash mass A7_DPF_OIL_ASH_MASS

  • Request22 40 6C
  • Service 22DID 406C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 10)
Range
0 to 429496729
Unit
Raw value

In testing for 2019 to 2026.

Diesel particulate filter oil ash volume A7_DPF_OIL_ASH_VOLUME

  • Request22 20 8B
  • Service 22DID 208B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 L
Unit
L

In testing for 2019 to 2026.

Diesel particulate filter oil ash volume, bank 1 A7_DPF_OIL_ASH_VOLUME_1

  • Request22 14 B9
  • Service 22DID 14B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 L
Unit
L

In testing for 2010 to 2018.

Diesel particulate filter oil ash volume, bank 2 A7_DPF_OIL_ASH_VOLUME_2

  • Request22 14 5F
  • Service 22DID 145F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 L
Unit
L

In testing for 2010 to 2018.

Diesel particulate filter outlet temperature A7_PQ35_DPF_OUT_TConfirmed

  • Request22 10 F9
  • Service 22DID 10F9
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x105D = 4189 → (4189 ÷ 10 − 273.1) = 145.8 °C

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Diesel particulate filter regeneration cancel conditions A7_DPF_REGEN_CANCEL

  • Request22 13 7C
  • Service 22DID 137C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Diesel particulate filter service regeneration, duration with heat-up A7_DPF_SERVICE_REGEN

  • Request22 11 C3
  • Service 22DID 11C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 100)
Range
0 to 42949672 s
Unit
s

In testing for 2019 to 2026.

Diesel particulate filter soot mass calculated, bank 1 A7_DPF_SOOT_MASS_CALC_1

  • Request22 14 BA
  • Service 22DID 14BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2010 to 2018.

Diesel particulate filter soot mass calculated, bank 2 A7_DPF_SOOT_MASS_CALC_2

  • Request22 14 5E
  • Service 22DID 145E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2010 to 2018.

Diesel particulate filter soot mass measured, bank 1 A7_DPF_SOOT_MASS_MEAS_1

  • Request22 14 BB
  • Service 22DID 14BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2010 to 2018.

Diesel particulate filter soot mass measured, bank 2 A7_DPF_SOOT_MASS_MEAS_2

  • Request22 14 5D
  • Service 22DID 145D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2010 to 2018.

Diesel particulate filter soot measured A7_DPF_SOOT_MEAS

  • Request22 20 8C
  • Service 22DID 208C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2019 to 2026.

Diesel particulate filter soot volume in exhaust, mg/m^3 A7_DPF_SOOT_VOLUME_EXH_M_3

  • Request22 18 C0
  • Service 22DID 18C0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Number

In testing for 2019 to 2026.

Diesel particulate filter statistics current avg. temperature after DPF A7_DPF_STATISTICS_T

  • Request22 15 7C
  • Service 22DID 157C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2019 to 2026.

Diesel particulate filter statistics current avg. temperature after part.filter A7_DPF_STATISTICS_CURRENT_AVG_T

  • Request22 40 01
  • Service 22DID 4001
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2019 to 2026.

Diesel particulate filter statistics current calculated charging rate, g/km A7_DPF_STATISTICS_CURRENT_G

  • Request22 40 07
  • Service 22DID 4007
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 12207 ÷ 100000000)
Range
-3.99 to 3.99
Unit
Number

In testing for 2019 to 2026.

Diesel particulate filter statistics current measured charging rate, g/km A7_DPF_STATISTICS_G

  • Request22 40 05
  • Service 22DID 4005
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 12207 ÷ 100000000)
Range
-3.99 to 3.99
Unit
Number

In testing for 2019 to 2026.

Diesel particulate filter surface temperature A7_DPF_SFC_TConfirmed

  • Request22 10 44
  • Service 22DID 1044
  • Module7E0 → 7E8
  • Every300 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x118A = 4490 → (4490 ÷ 10 − 273.1) = 175.9 °C

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Diesel particulate filter time since last regeneration A7_DPF_TIME_SINCE_REGEN

  • Request22 20 89
  • Service 22DID 2089
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 3600)
Range
0 to 1193046 h
Unit
h

In testing for 2019 to 2026.

Diesel particulate filter time since last regeneration, h, bank 1 A7_DPF_TIME_SINCE_REGEN_H_1

  • Request22 14 34
  • Service 22DID 1434
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 3600)
Range
0 to 1193046
Unit
Raw value

In testing for 2010 to 2018.

Diesel particulate filter time since last regeneration, h, bank 2 A7_DPF_TIME_SINCE_REGEN_H_2

  • Request22 14 64
  • Service 22DID 1464
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 3600)
Range
0 to 1193046
Unit
Raw value

In testing for 2010 to 2018.

Differential pressure A7_PQ35_DIFF_PConfirmed

  • Request22 14 F5
  • Service 22DID 14F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0005 = 5 → 5

Formula
val
Range
-32768 to 32767
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Driving mode sensor, hall sensor a A7_DRIVING_MODE_SENS

  • Request22 21 0D
  • Service 22DID 210D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Driving position A7_DRIVING_POS

  • Request22 21 0E
  • Service 22DID 210E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Driving resistance index A7_DRIVING_RES_INDEX

  • Request22 21 08
  • Service 22DID 2108
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 128)
Range
-128 to 127
Unit
Number

In testing for 2019 to 2026.

Dynamic torque limitation A7_DYNAMIC_TQ_LIM

  • Request22 10 67
  • Service 22DID 1067
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2019 to 2026.

Ea888b boost pressure control, adaptation value 0 A7_EA888B_BOOST_P_CTRL_0

  • Request22 11 FF
  • Service 22DID 11FF
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 281 ÷ 100)
Range
-359 to 356
Unit
Raw value

In testing for 2019 to 2026.

Ea888b boost pressure control, adaptation value 1 A7_EA888B_BOOST_P_CTRL_1

  • Request22 12 00
  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 281 ÷ 100)
Range
-359 to 356
Unit
Raw value

In testing for 2019 to 2026.

Ea888b boost pressure control, adaptation value 2 A7_EA888B_BOOST_P_CTRL_2

  • Request22 12 01
  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 281 ÷ 100)
Range
-359 to 356
Unit
Raw value

In testing for 2019 to 2026.

Ea888b boost pressure control, adaptation value 3 A7_EA888B_BOOST_P_CTRL_3

  • Request22 12 02
  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 281 ÷ 100)
Range
-359 to 356
Unit
Raw value

In testing for 2019 to 2026.

Ea888b boost pressure regulator, commanded A7_EA888B_BOOST_P_CMD

  • Request22 11 A3
  • Service 22DID 11A3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026.

Early ignition counter, total, cylinder 1 A7_EARLY_IGN_CNT_TOT_1

  • Request22 17 15
  • Service 22DID 1715
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Early ignition counter, total, cylinder 2 A7_EARLY_IGN_CNT_TOT_2

  • Request22 17 18
  • Service 22DID 1718
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Early ignition counter, total, cylinder 3 A7_EARLY_IGN_CNT_TOT_3

  • Request22 17 16
  • Service 22DID 1716
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Early ignition counter, total, cylinder 4 A7_EARLY_IGN_CNT_TOT_4

  • Request22 17 17
  • Service 22DID 1717
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Early ignition counter:, cylinder 1 A7_EARLY_IGN_CNT_CYL_1

  • Request22 17 22
  • Service 22DID 1722
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Early ignition counter:, cylinder 2 A7_EARLY_IGN_CNT_CYL_2

  • Request22 17 25
  • Service 22DID 1725
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Early ignition counter:, cylinder 3 A7_EARLY_IGN_CNT_CYL_3

  • Request22 17 23
  • Service 22DID 1723
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Early ignition counter:, cylinder 4 A7_EARLY_IGN_CNT_CYL_4

  • Request22 17 24
  • Service 22DID 1724
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Effective injection duration A7_EFFECTIVE_INJ_DUR

  • Request22 15 E7
  • Service 22DID 15E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 ms
Unit
ms

In testing for 2019 to 2026.

EGT after catalyst, model bank 1 A7_EGT_AFTER_CAT_MODEL_1

  • Request22 2A E9
  • Service 22DID 2AE9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.023438 − 273.15)
Range
-273 to 1262 °C
Unit
°C

In testing for 2019 to 2026.

EGT after catalyst, model bank b A7_EGT_AFTER_CAT_MODEL_B

  • Request22 2A E3
  • Service 22DID 2AE3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.023438 − 273.15)
Range
-273 to 1262 °C
Unit
°C

In testing for 2019 to 2026.

EGT after catalyst, modeled A7_EGT_AFTER_CAT

  • Request22 12 72
  • Service 22DID 1272
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2019 to 2026.

EGT at lambda sensor 1, modeled A7_EGT_LAMBDA_SENS_1

  • Request22 13 9C
  • Service 22DID 139C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2019 to 2026.

Electric motor 1 rpm A7_EM_RPM_1Confirmed

  • Request22 11 51
  • Service 22DID 1151
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2010 to 2019, 2021 to 2026

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2)
Range
-100 to 100 rpm
Unit
rpm

Confirmed for 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2016.

Electric motor 1 torque A7_EM_TORQ_1Confirmed

  • Request22 11 53
  • Service 22DID 1153
  • Module7E0 → 7E8
  • Every10.25 s
  • Testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x5781 = 22401 → (22401 ÷ 32) = 700.03125 N·m

Formula
(val ÷ 32)
Range
-1000 to 1000 N·m
Unit
N·m

Confirmed for 2011 to 2012, 2016, 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026.

Electric motor 2 rpm A7_EM_RPM_2Confirmed

  • Request22 11 52
  • Service 22DID 1152
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0xFFFF = -1 → (-1 ÷ 2) = -0.5 rpm

Formula
(val ÷ 2)
Range
-100 to 100 rpm
Unit
rpm

Confirmed for 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2016.

Electric motor 2 torque A7_EM_TORQ_2Confirmed

  • Request22 11 54
  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x8888 = -30584 → (-30584 ÷ 32) = -955.75 N·m

Formula
(val ÷ 32)
Range
-1000 to 1000 N·m
Unit
N·m

Confirmed for 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2016.

Energy balance of last driving cycle A7_ENERGY_BALANCE_LAST

  • Request22 2A 15
  • Service 22DID 2A15
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 Ah
Unit
Ah

In testing for 2019 to 2026.

Engine compartment temperature raw value A7_ENG_COMPARTMENT_T

  • Request22 46 B1
  • Service 22DID 46B1
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2019 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2012, 2020. Supported for 2016, 2021.

Engine coolant temperature 1 ECT_1SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020.

Engine coolant temperature 2 ECT_2SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020.

Engine oil level A7_PQ35_OIL_LVLConfirmed

  • Request22 11 BC
  • Service 22DID 11BC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x25AD = 9645 → (9645 ÷ 250) = 38.58 mm

Formula
(val ÷ 250)
Range
-131.072 to 131.068 mm
Unit
mm

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Engine oil level current value A7_ENG_OIL_LEVEL

  • Request22 58 D1
  • Service 22DID 58D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2019 to 2026.

Engine oil temperature A7_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request22 10 E6
  • Service 22DID 10E6
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 60)
Range
-60 to 195 °C
Unit
°C

In testing for 2010 to 2018.

Engine oil temperature A7_EOT_7E0

Pelican can show this parameter as the engine oil temperature.

  • Request22 20 2F
  • Service 22DID 202F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2019 to 2026.

Engine oil temperature A7_EOT_V2Confirmed

Scaling is unknown, needs further validation.

  • Request22 11 BE
  • Service 22DID 11BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2011 to 2012, 2016, 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026.

Engine oil temperature sensor 2 A7_EOT_SENS_2

Pelican can show this parameter as the engine oil temperature.

  • Request22 40 D5
  • Service 22DID 40D5
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2019 to 2026.

Engine oil temperature, pulse sensor A7_EOT_PULS

  • Request22 17 9E
  • Service 22DID 179E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2019 to 2026.

Engine outlet coolant temperature calculated A7_ENG_OUTLET_ECT_CALC

  • Request22 10 63
  • Service 22DID 1063
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2019 to 2026.

Engine protection, torque limit A7_ENG_PROTECTION_TQ

  • Request22 2B C0
  • Service 22DID 2BC0
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2019 to 2026.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2020. Supported for 2012, 2016, 2021.

Engine start quantity A7_PQ35_ENG_START_QTYConfirmed

  • Request22 10 69
  • Service 22DID 1069
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x070C = 1804 → (1804 ÷ 100) = 18.04

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Engine torque A7_ENG_TQ

  • Request22 10 10
  • Service 22DID 1010
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2010 to 2018.

Engine torque A7_ENG_TQ_7E1

  • Request22 20 02
  • Service 22DID 2002
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2019 to 2026.

Engine torque A7_PQ35_ENG_TORQUEConfirmed

  • Request22 15 5A
  • Service 22DID 155A
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 32) = 0 N·m

Formula
(val ÷ 32)
Range
-1024 to 1023.968 N·m
Unit
N·m

Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.

Engine torque A7_PQ35_ENG_TRQConfirmed

  • Request22 10 47
  • Service 22DID 1047
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x013F = 319 → (319 ÷ 10) = 31.9 N·m

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Engine torque loss A7_MQB_TCM_ENGINE_TORQUE_LOSS

  • Request22 10 0F
  • Service 22DID 100F
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35 N·m
Unit
N·m

In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.

Environment data camshaft input 1 A7_PQ35_ENVD_CAM_IN_1Confirmed

  • Request22 12 13
  • Service 22DID 1213
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.

Evaporator temperature A7_EVAPORATOR_T

  • Request22 42 BB
  • Service 22DID 42BB
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2019 to 2026.

Excessive temperature protection A7_EXCESSIVE_T

  • Request22 21 17
  • Service 22DID 2117
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Exhaust camshaft, adaptation bias A7_EXH_CAM_ADPT_BIAS

  • Request22 17 4A
  • Service 22DID 174A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720 to 719 °
Unit
°

In testing for 2019 to 2026.

Exhaust camshaft, adaptation sensor tolerance A7_EXH_CAM_ADPT_SENS

  • Request22 17 55
  • Service 22DID 1755
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720 to 719 °
Unit
°

In testing for 2019 to 2026.

Exhaust gas jet volume in particle filter, m^3/h A7_EXH_GAS_JET_VOLUME_M_3_H

  • Request22 3D 7E
  • Service 22DID 3D7E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 10)
Range
-214748364 to 214748364
Unit
Number

In testing for 2019 to 2026.

Exhaust gas recirculation valve duty A7_PQ35_EGR_DUTYConfirmed

  • Request22 10 C2
  • Service 22DID 10C2
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x1CED = 7405 → (7405 ÷ 100) = 74.05 %

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Exhaust gas temperature before catalyst, modeled A7_EGT_PRE_CAT_MODELED

  • Request22 14 21
  • Service 22DID 1421
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2019 to 2026.

Exhaust gas temperature sensor 1 A7_EXH_GAS_T_SENS_1

  • Request22 16 6F
  • Service 22DID 166F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2010 to 2018.

Exhaust gas temperature sensor 1 A7_PQ35_EXH_GAS_T_1Confirmed

  • Request22 10 FB
  • Service 22DID 10FB
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x1113 = 4371 → (4371 ÷ 10 − 273.1) = 164 °C

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Exhaust gas temperature sensor 1, bank 2 A7_EXH_GAS_T_SENS_1_2

  • Request22 16 70
  • Service 22DID 1670
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2010 to 2018.

Exhaust gas temperature sensor 2 A7_PQ35_EXHAUST_GAS_T_SENSOR_2Confirmed

  • Request22 14 F7
  • Service 22DID 14F7
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x1357 = 4951 → (4951 ÷ 10 − 273.1) = 222 °C

Formula
(val ÷ 10 − 273.1)
Range
-3549.9 to 3003.6 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Exhaust gas temperature sensor 3 A7_EXH_GAS_T_SENS_3

  • Request22 14 BE
  • Service 22DID 14BE
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2010 to 2018.

Exhaust gas temperature sensor 3, bank 2 A7_EXH_GAS_T_SENS_3_2

  • Request22 15 6F
  • Service 22DID 156F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2010 to 2018.

Exhaust phase deviation, actual value A7_EXH_PHASE_DEV_ACT

  • Request22 41 85
  • Service 22DID 4185
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 °
Unit
°

In testing for 2019 to 2026.

Exhaust phase deviation, after chain replacement A7_EXH_PHASE_DEV_AFTER

  • Request22 41 7D
  • Service 22DID 417D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 °
Unit
°

In testing for 2019 to 2026.

Exhaust phase deviation, after repair A7_EXH_PHASE_DEV_AFTER_REPAIR

  • Request22 41 81
  • Service 22DID 4181
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 °
Unit
°

In testing for 2019 to 2026.

Exhaust timing chain extension, mileage since last adaptation A7_EXH_TIM_CHAIN

  • Request22 51 49
  • Service 22DID 5149
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2019 to 2026.

Field limit value A7_PQ35_FIELD_LIMConfirmed

  • Request22 11 F6
  • Service 22DID 11F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0A88 = 2696 → (2696 ÷ 100) = 26.96

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Friction torque A7_FRICTION_TQ

  • Request22 10 65
  • Service 22DID 1065
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2019 to 2026.

Front defrost flap air outlet temperature A7_FRONT_DEFROST_FLAP_T

  • Request22 42 C8
  • Service 22DID 42C8
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2019 to 2026.

Front left deflector temperature A7_CLIMATE_FR_L_DEFL_TConfirmed

  • Request22 26 0C
  • Service 22DID 260C
  • Module746 → 7B0
  • Every5 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 7 of the reply, 8 bits.

0x46 = 70 → (70 ÷ 3) = 23.333333 °C

Formula
(val ÷ 3)
Range
0 to 84.915 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Front right deflector temperature A7_CLIMATE_FR_R_DEFL_TConfirmed

  • Request22 26 0D
  • Service 22DID 260D
  • Module746 → 7B0
  • Every5 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 7 of the reply, 8 bits.

0x49 = 73 → (73 ÷ 3) = 24.333333 °C

Formula
(val ÷ 3)
Range
0 to 84.915 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Fuel metering valve position A7_PQ35_FUEL_METERConfirmed

  • Request22 11 48
  • Service 22DID 1148
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 100) = 0 %

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Fuel temperature A7_PQ35_FUEL_TConfirmed

  • Request22 16 2D
  • Service 22DID 162D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0BBB = 3003 → (3003 ÷ 10 − 273.1) = 27.2 °C

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Generator current A7_GEN_CURRENT

  • Request22 2A 1C
  • Service 22DID 2A1C
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 A
Unit
A

In testing for 2019 to 2026.

Generator load A7_PQ35_GEN_LOADConfirmed

  • Request22 10 5C
  • Service 22DID 105C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 100) = 0 %

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Generator load normalized value A7_GEN_LOAD_NORM

  • Request22 15 CA
  • Service 22DID 15CA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2019 to 2026.

Generator load signal A7_GEN_LOAD_SIG

  • Request22 10 1C
  • Service 22DID 101C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2019 to 2026.

Generator power A7_GEN_POWER

  • Request22 10 97
  • Service 22DID 1097
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 94247 ÷ 10000)
Range
0 to 617647 W
Unit
W

In testing for 2019 to 2026.

Generator torque request A7_GEN_TQ_REQ

  • Request22 10 1B
  • Service 22DID 101B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2019 to 2026.

Glow plug preheat time A7_PQ35_PREHEAT_TConfirmed

  • Request22 11 1F
  • Service 22DID 111F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 × 100) = 0 ms

Formula
(val × 100)
Range
-3276800 to 3276700 ms
Unit
ms

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Heater circulation pump, nominal value A7_HEATER_CIRCULATION

  • Request22 16 7F
  • Service 22DID 167F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 %
Unit
%

In testing for 2019 to 2026.

Height correction A7_HEIGHT_CORR

  • Request22 11 36
  • Service 22DID 1136
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0000610348)
Range
0 to 3.99
Unit
Number

In testing for 2019 to 2026.

High pressure control, adaptation A7_HIGH_P_CTRL_ADPT

  • Request22 11 D2
  • Service 22DID 11D2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 2000)
Range
-16.38 to 16.38
Unit
Raw value

In testing for 2019 to 2026.

High pressure EGR actuator, activation A7_HIGH_P_EGR_ACTUATOR

  • Request22 13 34
  • Service 22DID 1334
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2019 to 2026.

Humidity sensor, relative humidity A7_HUMIDITY_SENS_REL

  • Request22 50 36
  • Service 22DID 5036
  • Module70E → 778
  • Every1 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val × 99 ÷ 200)
Range
0 to 32439 %
Unit
%

In testing for 2019 to 2026.

Hybrid temperature A7_MQB_TCM_HYBRID_TConfirmed

  • Request22 11 96
  • Service 22DID 1196
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0381 = 897 → 897 °C

Formula
val
Range
0 to 65535 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

ID of current driving program A7_ID_CURRENT_DRIVING

  • Request22 10 12
  • Service 22DID 1012
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Injection amount deviation cylinder 1 A7_PQ35_INJ_DEV_CYL_1Confirmed

  • Request22 10 FF
  • Service 22DID 10FF
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0023 = 35 → (35 ÷ 100) = 0.35

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Injection amount deviation cylinder 2 A7_INJ_AMOUNT_DEV_CYL_2

  • Request22 11 06
  • Service 22DID 1106
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2010 to 2018.

Injection amount deviation cylinder 2 A7_PQ35_INJ_DEV_CYL_2Confirmed

  • Request22 11 05
  • Service 22DID 1105
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0002 = 2 → (2 ÷ 100) = 0.02

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Injection amount deviation cylinder 3 A7_PQ35_INJ_DEV_CYL_3Confirmed

  • Request22 11 00
  • Service 22DID 1100
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x002E = 46 → (46 ÷ 100) = 0.46

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Injection amount deviation cylinder 4 A7_PQ35_INJ_DEV_CYL_4Confirmed

  • Request22 11 04
  • Service 22DID 1104
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x000B = 11 → (11 ÷ 100) = 0.11

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Injection amount deviation cylinder 5 A7_INJ_AMOUNT_DEV_CYL_5

  • Request22 11 07
  • Service 22DID 1107
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2010 to 2018.

Injection quantity deviation, cylinder 1 A7_INJ_QTY_DEV_CYL_1

  • Request22 20 46
  • Service 22DID 2046
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2019 to 2026.

Injection quantity deviation, cylinder 2 A7_INJ_QTY_DEV_CYL_2

  • Request22 20 4A
  • Service 22DID 204A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2019 to 2026.

Injection quantity deviation, cylinder 3 A7_INJ_QTY_DEV_CYL_3

  • Request22 20 48
  • Service 22DID 2048
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2019 to 2026.

Injection quantity deviation, cylinder 4 A7_INJ_QTY_DEV_CYL_4

  • Request22 20 47
  • Service 22DID 2047
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2019 to 2026.

Injection quantity deviation, cylinder 5 A7_INJ_QTY_DEV_CYL_5

  • Request22 20 4B
  • Service 22DID 204B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2019 to 2026.

Injection quantity deviation, cylinder 6 A7_INJ_QTY_DEV_CYL_6

  • Request22 20 49
  • Service 22DID 2049
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2019 to 2026.

Injector 1 rail pressure calibration point 1 A7_PQ35_INJ_1_RAIL_P_1Confirmed

  • Request22 10 D0
  • Service 22DID 10D0
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0133 = 307 → (307 ÷ 20000) = 0.01535 ms

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Injector 1 rail pressure calibration point 2 A7_PQ35_INJ_1_RAIL_P_2Confirmed

  • Request22 10 D6
  • Service 22DID 10D6
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0011 = 17 → (17 ÷ 20000) = 0.00085 ms

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Injector 1 rail pressure calibration point 3 A7_PQ35_INJ_1_RAIL_P_3Confirmed

  • Request22 10 DC
  • Service 22DID 10DC
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0xFE1A = -486 → (-486 ÷ 20000) = -0.0243 ms

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Injector 2 rail pressure calibration point 1 A7_PQ35_INJ_2_RAIL_P_1Confirmed

  • Request22 10 D3
  • Service 22DID 10D3
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0001 = 1 → (1 ÷ 20000) = 0.00005 ms

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Injector 2 rail pressure calibration point 2 A7_PQ35_INJ_2_RAIL_P_2Confirmed

  • Request22 10 D9
  • Service 22DID 10D9
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0xFF64 = -156 → (-156 ÷ 20000) = -0.0078 ms

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Injector 2 rail pressure calibration point 3 A7_PQ35_INJ_2_RAIL_P_3Confirmed

  • Request22 10 DF
  • Service 22DID 10DF
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0xFEB4 = -332 → (-332 ÷ 20000) = -0.0166 ms

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Injector 2, rail pressure calibration point 1 A7_INJ_2_RAIL_P_1

  • Request22 10 D4
  • Service 22DID 10D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2010 to 2018.

Injector 2, rail pressure calibration point 2 A7_INJ_2_RAIL_P_2

  • Request22 10 DA
  • Service 22DID 10DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2010 to 2018.

Injector 2: rail pressure calibration point 2 A7_INJ_2_RAIL_P_CAL_PT_2_1474

  • Request22 14 74
  • Service 22DID 1474
  • Module7E0 → 7E8
  • Every300 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638.4 to 1638.35
Unit
Raw value

In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.

Injector 3 rail pressure calibration point 1 A7_PQ35_INJ_3_RAIL_P_1Confirmed

  • Request22 10 D1
  • Service 22DID 10D1
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x00E7 = 231 → (231 ÷ 20000) = 0.01155 ms

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Injector 3 rail pressure calibration point 2 A7_PQ35_INJ_3_RAIL_P_2Confirmed

  • Request22 10 D2
  • Service 22DID 10D2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x00BA = 186 → (186 ÷ 20000) = 0.0093 ms

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Injector 3 rail pressure calibration point 3 A7_PQ35_INJ_3_RAIL_P_3Confirmed

  • Request22 10 DD
  • Service 22DID 10DD
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0xFF94 = -108 → (-108 ÷ 20000) = -0.0054 ms

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Injector 4 rail pressure calibration point 2 A7_PQ35_INJ_4_RAIL_P_2Confirmed

  • Request22 10 D8
  • Service 22DID 10D8
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0xFF4F = -177 → (-177 ÷ 20000) = -0.00885 ms

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Injector 4 rail pressure calibration point 3 A7_PQ35_INJ_4_RAIL_P_3Confirmed

  • Request22 10 DE
  • Service 22DID 10DE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 20000) = 0 ms

Formula
(val ÷ 20000)
Range
-1.6384 to 1.63 ms
Unit
ms

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Injector 4, rail pressure calibration point 2 A7_INJ_4_RAIL_P_2

  • Request22 10 D7
  • Service 22DID 10D7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2010 to 2018.

Injector 5, rail pressure calibration point 1 A7_INJ_5_RAIL_P_1

  • Request22 10 D5
  • Service 22DID 10D5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2010 to 2018.

Injector 5, rail pressure calibration point 2 A7_INJ_5_RAIL_P_2

  • Request22 10 DB
  • Service 22DID 10DB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2010 to 2018.

Injector 5, rail pressure calibration point 3 A7_INJ_5_RAIL_P_3

  • Request22 10 E1
  • Service 22DID 10E1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20000)
Range
-1.63 to 1.63 ms
Unit
ms

In testing for 2010 to 2018.

Inlet flaps - actual value A7_INLET_FLAPS_ACT

  • Request22 11 9D
  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 13107)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026.

Inlet flaps - requested value A7_INLET_FLAPS_REQ

  • Request22 11 A0
  • Service 22DID 11A0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 20 ÷ 13107)
Range
0 to 100 %
Unit
%

In testing for 2019 to 2026.

Inside temperature A7_INSIDE_T

  • Request22 26 13
  • Service 22DID 2613
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 50)
Range
-50 to 6503 °C
Unit
°C

In testing for 2019 to 2026.

Intake air temperature A7_IAT

  • Request22 10 01
  • Service 22DID 1001
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2010 to 2018.

Intake air temperature A7_IAT_7E0

  • Request22 14 9E
  • Service 22DID 149E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 4 − 48)
Range
-48 to 143 °C
Unit
°C

In testing for 2019 to 2026.

Intake air temperature raw value A7_IAT_RAW

  • Request22 15 C0
  • Service 22DID 15C0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2019 to 2026.

Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2020.

Intake camshaft adaptation unit 1 phase length A7_PQ35_CAMS_ADAPT_PHASE_1Confirmed

  • Request22 12 FE
  • Service 22DID 12FE
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0xFF27 = -217 → (-217 ÷ 50) = -4.34 °

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Intake camshaft signal edge position adapted edge 2 A7_PQ35_CAMS_EDGE_POS_2Confirmed

  • Request22 11 89
  • Service 22DID 1189
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0xFFFF = 65535 → (65535 ÷ 16 − 32) = 4,063.9375 °

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.

Intake camshaft signal edge position adapted edge 3 A7_PQ35_CAMS_EDGE_POS_3Confirmed

  • Request22 11 8A
  • Service 22DID 118A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0xFFFF = 65535 → (65535 ÷ 16 − 32) = 4,063.9375 °

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.

Intake camshaft signal edge position adapted edge 4 A7_PQ35_CAMS_EDGE_POS_4Confirmed

  • Request22 11 8B
  • Service 22DID 118B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x5092 = 20626 → (20626 ÷ 16 − 32) = 1,257.125 °

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Intake camshaft signal edge position adapted edge 5 A7_PQ35_CAMS_EDGE_POS_5

  • Request22 11 8C
  • Service 22DID 118C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.

Intake camshaft signal edge position adapted edge 6 A7_PQ35_CAMS_EDGE_POS_6

  • Request22 11 8D
  • Service 22DID 118D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.

Intake camshaft signal edge position adapted edge 7 A7_PQ35_CAMS_EDGE_POS_7

  • Request22 11 8E
  • Service 22DID 118E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.

Intake camshaft signal edge position adapted edge 8 A7_PQ35_CAMS_EDGE_POS_8

  • Request22 11 8F
  • Service 22DID 118F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 32)
Range
-32 to 4063.937 °
Unit
°

In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.

Intake camshaft, adaptation bias A7_INT_CAM_ADPT_BIAS

  • Request22 17 4B
  • Service 22DID 174B
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720 to 719 °
Unit
°

In testing for 2019 to 2026.

Intake camshaft, adaptation sensor tolerance A7_INT_CAM_ADPT_SENS

  • Request22 17 40
  • Service 22DID 1740
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 0.021973)
Range
-720 to 719 °
Unit
°

In testing for 2019 to 2026.

Intake manifold pressure, commanded A7_INT_MANIFOLD_P_CMD

  • Request22 11 DD
  • Service 22DID 11DD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 5119
Unit
Raw value

In testing for 2019 to 2026.

Intake manifold pressure, corrected A7_INT_MANIFOLD_P

  • Request22 11 DA
  • Service 22DID 11DA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 5119
Unit
Raw value

In testing for 2019 to 2026.

Intake model air mass flow filtered value A7_INT_MODEL_AIR_MASS

  • Request22 11 AB
  • Service 22DID 11AB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Raw value

In testing for 2019 to 2026.

Intake phase deviation, actual value A7_INT_PHASE_DEV_ACT

  • Request22 18 00
  • Service 22DID 1800
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 °
Unit
°

In testing for 2019 to 2026.

Intake phase deviation, after chain replacement A7_INT_PHASE_DEV_AFTER

  • Request22 41 7B
  • Service 22DID 417B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 °
Unit
°

In testing for 2019 to 2026.

Intake phase deviation, after repair A7_INT_PHASE_DEV_AFTER_REPAIR

  • Request22 41 7F
  • Service 22DID 417F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047 °
Unit
°

In testing for 2019 to 2026.

Intake timing chain extension, mileage since last adaptation A7_INT_TIM_CHAIN

  • Request22 51 6C
  • Service 22DID 516C
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2019 to 2026.

Integrated mass of air since engine start A7_INTEGRATED_MASS_AIR

  • Request22 11 75
  • Service 22DID 1175
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 8889 ÷ 25000)
Range
0 to 23301
Unit
Raw value

In testing for 2019 to 2026.

Integrated mass of air since the first engine start A7_INTEGRATED_MASS_AIR_SINCE

  • Request22 17 43
  • Service 22DID 1743
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 8889 ÷ 25000)
Range
0 to 23301
Unit
Raw value

In testing for 2019 to 2026.

Intercooler air output temperature A7_PQ35_INTERCOOLER_AIR_OUTPUT_TConfirmed

  • Request22 16 28
  • Service 22DID 1628
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0B61 = 2913 → (2913 ÷ 10 − 273.1) = 18.2 °C

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Kick down A7_MQB_TCM_KICK_DOWNConfirmed

  • Request22 21 14
  • Service 22DID 2114
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Kilometers driven since last event on K1 A7_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K1Confirmed

  • Request22 11 5A
  • Service 22DID 115A
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2010, 2013 to 2026

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 10)
Range
0 to 7000 km
Unit
km

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Kilometers driven since last event on K2 A7_MQB_DQ250_KILOMETERS_DRIVEN_SINCE_LAST_EVENT_ON_K2Confirmed

  • Request22 11 5C
  • Service 22DID 115C
  • Module7E1 → 7E9
  • Every30 s
  • Testing for 2010, 2013 to 2026

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 10)
Range
0 to 7000 km
Unit
km

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Knock retard 4 A7_KNOCK_RETARD_4

  • Request22 10 E7
  • Service 22DID 10E7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2010 to 2018.

Knock retard 6 A7_KNOCK_RETARD_6

  • Request22 10 E5
  • Service 22DID 10E5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

In testing for 2010 to 2018.

Knock retard:, cylinder 1 A7_KNOCK_RETARD_CYL_1

  • Request22 13 F2
  • Service 22DID 13F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.62 °
Unit
°

In testing for 2010 to 2018.

Knock retard:, cylinder 2 A7_KNOCK_RETARD_CYL_2

  • Request22 13 F3
  • Service 22DID 13F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.62 °
Unit
°

In testing for 2010 to 2018.

Knock retard:, cylinder 3 A7_KNOCK_RETARD_CYL_3

  • Request22 13 F4
  • Service 22DID 13F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.62 °
Unit
°

In testing for 2010 to 2018.

Knock retard:, cylinder 4 A7_KNOCK_RETARD_CYL_4

  • Request22 13 F5
  • Service 22DID 13F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.62 °
Unit
°

In testing for 2010 to 2018.

Knock retard:, cylinder 5 A7_KNOCK_RETARD_CYL_5

  • Request22 13 F6
  • Service 22DID 13F6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.62 °
Unit
°

In testing for 2010 to 2018.

Knock retard:, cylinder 6 A7_KNOCK_RETARD_CYL_6

  • Request22 13 F7
  • Service 22DID 13F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 8 − 48)
Range
-48 to 47.62 °
Unit
°

In testing for 2010 to 2018.

Knock sensor, cylinder 1 A7_KNOCK_SENS_CYL_1

  • Request22 12 0E
  • Service 22DID 120E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 7.62e-7)
Range
0 to 3272
Unit
Number

In testing for 2019 to 2026.

Knock sensor, cylinder 2 A7_KNOCK_SENS_CYL_2

  • Request22 12 12
  • Service 22DID 1212
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 7.62e-7)
Range
0 to 3272
Unit
Number

In testing for 2019 to 2026.

Knock sensor, cylinder 3 A7_KNOCK_SENS_CYL_3

  • Request22 12 10
  • Service 22DID 1210
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 7.62e-7)
Range
0 to 3272
Unit
Number

In testing for 2019 to 2026.

Knock sensor, cylinder 4 A7_KNOCK_SENS_CYL_4

  • Request22 12 0F
  • Service 22DID 120F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 7.62e-7)
Range
0 to 3272
Unit
Number

In testing for 2019 to 2026.

Knock sensor, cylinder 6 A7_KNOCK_SENS_CYL_6

  • Request22 12 11
  • Service 22DID 1211
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val × 7.62e-7)
Range
0 to 3272
Unit
Number

In testing for 2019 to 2026.

Lambda output value A7_LAMBDA_OUTPUT

  • Request22 15 D4
  • Service 22DID 15D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 199997 ÷ 6553500000)
Range
0 to 1.99
Unit
Number

In testing for 2019 to 2026.

Launch control counter A7_LAUNCH_CTRL_CNT

  • Request22 38 F1
  • Service 22DID 38F1
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2018.

Left central air outlet temperature A7_LEFT_CENTRAL_AIR_T

  • Request22 42 C5
  • Service 22DID 42C5
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2019 to 2026.

Left foot well air outlet temperature A7_LEFT_FOOTWELL_AIR_T

  • Request22 42 BC
  • Service 22DID 42BC
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2019 to 2026.

Left rear foot well air outlet temperature A7_LEFT_REAR_FOOTWELL_T

  • Request22 42 C1
  • Service 22DID 42C1
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2019 to 2026.

Left rear upper air outlet temperature A7_LEFT_REAR_HI_AIR_T

  • Request22 42 BE
  • Service 22DID 42BE
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2019 to 2026.

Left side air outlet temperature A7_LEFT_SIDE_AIR_OUTLET_T

  • Request22 42 C3
  • Service 22DID 42C3
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2019 to 2026.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Request01 07
  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2020. Supported for 2021.

Long term fuel trim at idle - direct injection A7_LONG_TERM_FUEL_TRIM_IDLE

  • Request22 17 7E
  • Service 22DID 177E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 3 ÷ 64)
Range
-1536 to 1535 %
Unit
%

In testing for 2019 to 2026.

Long term fuel trim at idle - port injection A7_LONG_TERM_FUEL_TRIM_IDLE_PORT_INJ

  • Request22 17 80
  • Service 22DID 1780
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 3 ÷ 64)
Range
-1536 to 1535 %
Unit
%

In testing for 2019 to 2026.

Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed

  • Request01 56
  • Service 01PID 56
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2020.

Long term throttle adaptation to MAF sensor A7_LONG_TERM_THROTTLE

  • Request22 11 3A
  • Service 22DID 113A
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0000610351)
Range
0 to 3.99 %
Unit
%

In testing for 2019 to 2026.

M009, desired solenoid out 10 A7_M009_DES_SOLENOID_10

  • Request22 10 2E
  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026.

M009, desired solenoid out 11 A7_M009_DES_SOLENOID_11

  • Request22 10 2E
  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026.

M009, desired solenoid out 12 A7_M009_DES_SOLENOID_12

  • Request22 10 2E
  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026.

M009, desired solenoid out 13 A7_M009_DES_SOLENOID_13

  • Request22 10 2E
  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026.

M009, desired solenoid out 14 A7_M009_DES_SOLENOID_14

  • Request22 10 2E
  • Service 22DID 102E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2019 to 2026.

Main catalyst aging factor A7_MAIN_CAT_AGING

  • Request22 14 F9
  • Service 22DID 14F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 24581 ÷ 8054700000)
Range
0 to 0.199
Unit
Number

In testing for 2019 to 2026.

Main injection duration A7_PQ35_MAIN_INJ_DURATIONConfirmed

  • Request22 14 CF
  • Service 22DID 14CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x02A2 = 674 → (674 × 0.4 ÷ 1000) = 0.2696 ms

Formula
(val × 0.4 ÷ 1000)
Range
-13.1072 to 13.1068 ms
Unit
ms

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Main injection start position A7_PQ35_MAIN_INJ_STARTConfirmed

  • Request22 11 F2
  • Service 22DID 11F2
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 50) = 0 °

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Manifold absolute pressure, raw value A7_MAP_RAW

  • Request22 11 DC
  • Service 22DID 11DC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 5119
Unit
Raw value

In testing for 2019 to 2026.

Mass air flow through throttle A7_MAF_THROUGH_THROTTLE

  • Request22 11 AC
  • Service 22DID 11AC
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Raw value

In testing for 2019 to 2026.

Mass air flow, commanded A7_MAF_CMD

  • Request22 11 AD
  • Service 22DID 11AD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Raw value

In testing for 2019 to 2026.

Mass airflow sensor 1 bank 1 raw value A7_MQB_MAF_1_B1_RAWConfirmed

  • Request22 10 26
  • Service 22DID 1026
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 × 1000 ÷ 10000) = 0

Formula
(val × 1000 ÷ 10000)
Range
-3276.8 to 3276.7
Unit
Raw value

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Max permissible engine torque A7_MAX_PERMISSIBLE_ENG

  • Request22 21 1A
  • Service 22DID 211A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2019 to 2026.

Maximum ECU temperature A7_MAX_ECU_T

  • Request22 46 49
  • Service 22DID 4649
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2019 to 2026.

Mean injection quantity A7_MEAN_INJ_QUANTITYConfirmed

  • Request22 11 39
  • Service 22DID 1139
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x37FA = 14330 → (14330 ÷ 100) = 143.3

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Median injection timing A7_MEDIAN_INJ_TIM

  • Request22 12 8C
  • Service 22DID 128C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 ms
Unit
ms

In testing for 2010 to 2018.

Misfires / 1000 revolutions, cylinder 1 A7_MISFIRES_1000REV_C1Confirmed

  • Request22 11 47
  • Service 22DID 1147
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Misfires / 1000 revolutions, cylinder 2 A7_MISFIRES_1000REV_C2Confirmed

  • Request22 11 4A
  • Service 22DID 114A
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.

Misfires counter:, cylinder 1 A7_MIS_CNT_1

  • Request22 14 7E
  • Service 22DID 147E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2018.

Misfires counter:, cylinder 2 A7_MIS_CNT_2

  • Request22 14 82
  • Service 22DID 1482
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2018.

Misfires counter:, cylinder 3 A7_MIS_CNT_3

  • Request22 14 80
  • Service 22DID 1480
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2018.

Misfires counter:, cylinder 4 A7_MIS_CNT_4

  • Request22 14 7F
  • Service 22DID 147F
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2018.

Misfires counter:, cylinder 5 A7_MIS_CNT_5

  • Request22 14 83
  • Service 22DID 1483
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2018.

Misfires counter:, cylinder 6 A7_MIS_CNT_6

  • Request22 14 81
  • Service 22DID 1481
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2018.

Misfires for 1000 revolutions, cylinder 1 A7_MIS_1000_REVOLUTIONS_1

  • Request22 29 1D
  • Service 22DID 291D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires for 1000 revolutions, cylinder 2 A7_MIS_1000_REVOLUTIONS_2

  • Request22 29 20
  • Service 22DID 2920
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires for 1000 revolutions, cylinder 3 A7_MIS_1000_REVOLUTIONS_3

  • Request22 29 1E
  • Service 22DID 291E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires for 1000 revolutions, cylinder 4 A7_MIS_1000_REVOLUTIONS_4

  • Request22 29 1F
  • Service 22DID 291F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires per 1000 revolutions 2 A7_MIS_PER_1000_2

  • Request22 11 4B
  • Service 22DID 114B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2018.

Misfires per 1000 revolutions 4 A7_MIS_PER_1000_4

  • Request22 11 4C
  • Service 22DID 114C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010 to 2018.

Misfires total A7_MISFIRES_TOTALConfirmed

  • Request22 11 46
  • Service 22DID 1146
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Misfires, cylinder 1 A7_MIS_1

  • Request22 29 66
  • Service 22DID 2966
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires, cylinder 2 A7_MIS_2

  • Request22 29 69
  • Service 22DID 2969
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires, cylinder 3 A7_MIS_3

  • Request22 29 67
  • Service 22DID 2967
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Misfires, cylinder 3 A7_MISFIRES_C3_ECMConfirmed

  • Request22 11 50
  • Service 22DID 1150
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x5DE1 = 24033 → 24,033

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.

Misfires, cylinder 4 A7_MIS_4

  • Request22 29 68
  • Service 22DID 2968
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Number of automatic engine starts A7_NUM_AUTOMATIC_ENG

  • Request22 29 99
  • Service 22DID 2999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Number of engine starts, manual A7_NUM_ENG_STARTS

  • Request22 29 98
  • Service 22DID 2998
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Number of injections A7_NUM_INJECTIONS

  • Request22 43 0E
  • Service 22DID 430E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Oil ash limit A7_OIL_ASH_LIM

  • Request22 17 93
  • Service 22DID 1793
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2019 to 2026.

Oil ash residue A7_PQ35_OIL_ASH_RESIDUEConfirmed

  • Request22 17 8C
  • Service 22DID 178C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0

Formula
(val ÷ 10)
Range
0 to 6553.5
Unit
Raw value

Confirmed for 2020. In testing for 2010 to 2019, 2021 to 2026.

Oil dynamic average measurement A7_PQ35_OIL_DYN_AVGConfirmed

  • Request22 12 3F
  • Service 22DID 123F
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0xFFB7 = 65463 → (65463 ÷ 250) = 261.852 mm

Formula
(val ÷ 250)
Range
0 to 262.14 mm
Unit
mm

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Oil last dynamic measurement A7_PQ35_OIL_DYN_LASTConfirmed

  • Request22 12 3C
  • Service 22DID 123C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x018D = 397 → (397 ÷ 250) = 1.588 mm

Formula
(val ÷ 250)
Range
0 to 262.14 mm
Unit
mm

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Oil level A7_OIL_LEVELConfirmed

  • Request22 11 BA
  • Service 22DID 11BA
  • Module7E0 → 7E8
  • Every15 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x457A = 17786 → (17786 ÷ 2500) = 7.1144 cm

Formula
(val ÷ 2500)
Range
0 to 26.2 cm
Unit
cm

Confirmed for 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2016.

Oil level method 1 A7_OIL_LEVEL_METHOD_1

  • Request22 1A F9
  • Service 22DID 1AF9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 %
Unit
%

In testing for 2019 to 2026.

Oil level method 2 A7_OIL_LEVEL_METHOD_2

  • Request22 1A FA
  • Service 22DID 1AFA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 %
Unit
%

In testing for 2019 to 2026.

Oil level method 3 A7_OIL_LEVEL_METHOD_3

  • Request22 1A FB
  • Service 22DID 1AFB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 %
Unit
%

In testing for 2019 to 2026.

Oil level, average dynamic value A7_OIL_LEVEL_AVG

  • Request22 15 B9
  • Service 22DID 15B9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262 mm
Unit
mm

In testing for 2019 to 2026.

Oil level, static measurement A7_OIL_LEVEL_STATIC

  • Request22 40 CE
  • Service 22DID 40CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 127)
Range
-127 to 3968 mm
Unit
mm

In testing for 2010 to 2018.

Oil p A7_OIL_P

  • Request22 25 CD
  • Service 22DID 25CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2019 to 2026.

Oil pressure control valve activation pulse duty factor A7_OIL_P_CTRL_VLV

  • Request22 25 D0
  • Service 22DID 25D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2019 to 2026.

Oil pressure control valve, activation pulse duty factor A7_OIL_P_CTRL_VLV_ACTIVATION

  • Request22 4F 97
  • Service 22DID 4F97
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 %
Unit
%

In testing for 2019 to 2026.

Oil pressure sensor-piston cooling nozzle switch, status A7_OIL_P_SENS_PISTON

  • Request22 15 BD
  • Service 22DID 15BD
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Oil pressure sensor, raw value A7_OIL_P_SENS_RAW

  • Request22 1B 02
  • Service 22DID 1B02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Oil pressure switch valve activation A7_OIL_P_SWITCH_VLV

  • Request22 13 B8
  • Service 22DID 13B8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Oil pressure target A7_OIL_P_TGT

  • Request22 25 CF
  • Service 22DID 25CF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2019 to 2026.

Oil pressure target A7_OIL_P_TGT_7E0

  • Request22 4F 70
  • Service 22DID 4F70
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2019 to 2026.

Oil pressure, actual value A7_OIL_P_ACT_7E0

  • Request22 17 7D
  • Service 22DID 177D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 kPa
Unit
kPa

In testing for 2019 to 2026.

Oil pressure, actual value A7_OIL_P_ACT_7E0_2

  • Request22 1B 04
  • Service 22DID 1B04
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2019 to 2026.

Oil sump temperature A7_OIL_SUMP_T

  • Request22 15 B7
  • Service 22DID 15B7
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273 to 6280 °C
Unit
°C

In testing for 2019 to 2026.

Oil temp 2 A7_PQ35_ENGINE_OIL_T_2

  • Request22 17 9C
  • Service 22DID 179C
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2010 to 2019, 2021 to 2026

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

In testing for 2010, 2013 to 2019, 2021 to 2026. Supported for 2020. Not supported for 2011 to 2012.

Oil thermal wear A7_DASH_OIL_THERMAL_WEARConfirmed

  • Request22 22 4B
  • Service 22DID 224B
  • Module714 → 77E
  • Every300 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0031 = 49 → 49 km

Formula
val
Range
0 to 65535 km
Unit
km

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Outside temperature A7_OUTSIDE_T

  • Request22 22 0C
  • Service 22DID 220C
  • Module714 → 77E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 50)
Range
-50 to 77.5 °C
Unit
°C

In testing for 2019 to 2026.

Overall energy balance A7_OVERALL_ENERGY

  • Request22 2A 17
  • Service 22DID 2A17
  • Module710 → 77A
  • Every1 s
  • Testing

Bits 0 to 23 of the reply, 24 bits. The value is signed.

Formula
(val × 21 ÷ 20)
Range
-8808038 to 8808037 Ah
Unit
Ah

In testing for 2019 to 2026.

Oxygen sensor 1 bank 1 lambda value A7_PQ35_O2_SEN_1_LAMBDAConfirmed

  • Request22 11 3D
  • Service 22DID 113D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0D05 = 3333 → (3333 ÷ 100) = 33.33

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Number

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Particle sensor, cleaning deviation reaction time A7_PARTICLE_SENS

  • Request22 44 F5
  • Service 22DID 44F5
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1000)
Range
-32.76 to 32.76
Unit
Number

In testing for 2019 to 2026.

Particle sensor, exhaust temperature A7_PARTICLE_SENS_EXH_T

  • Request22 44 F8
  • Service 22DID 44F8
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2019 to 2026.

Particle sensor, soot volume in exhaust A7_PARTICLE_SENS_SOOT

  • Request22 44 F7
  • Service 22DID 44F7
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327
Unit
Raw value

In testing for 2019 to 2026.

Particle sensor, surface temperature A7_PARTICLE_SENS_T

  • Request22 44 FB
  • Service 22DID 44FB
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16 − 273.15)
Range
-2321 to 1774 °C
Unit
°C

In testing for 2019 to 2026.

Particle sensor, time in op.mode measurement A7_PARTICLE_SENS_TIME

  • Request22 46 D4
  • Service 22DID 46D4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 s
Unit
s

In testing for 2019 to 2026.

Pilot injection 1 duration A7_PQ35_PRE_INJ_1_DURATIONConfirmed

  • Request22 14 D0
  • Service 22DID 14D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 × 0.4 ÷ 1000) = 0 ms

Formula
(val × 0.4 ÷ 1000)
Range
-13.1072 to 13.1068 ms
Unit
ms

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Pilot injection 1 start position A7_PQ35_PRE_INJ_1_STARTConfirmed

  • Request22 14 C7
  • Service 22DID 14C7
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x02C2 = 706 → (706 ÷ 50) = 14.12 °

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Pilot injection 2 duration A7_PQ35_PRE_INJ_2_DURATIONConfirmed

  • Request22 14 D1
  • Service 22DID 14D1
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 × 0.4 ÷ 1000) = 0 ms

Formula
(val × 0.4 ÷ 1000)
Range
-13.1072 to 13.1068 ms
Unit
ms

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Pilot injection 2 start A7_PQ35_PRE_INJ_2_STARTConfirmed

  • Request22 14 C8
  • Service 22DID 14C8
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x006A = 106 → (106 ÷ 50) = 2.12 °

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Pilot injection 3, start A7_PRE_INJ_3_START

  • Request22 16 31
  • Service 22DID 1631
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 21973 ÷ 1000000)
Range
-720 to 719 °
Unit
°

In testing for 2019 to 2026.

Piston cooling nozzles, control A7_PISTON_COOLING

  • Request22 16 F4
  • Service 22DID 16F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Post injection 1: quantity specified value A7_PQ35_POST_INJ_1_QTY_SPECConfirmed

  • Request22 16 3C
  • Service 22DID 163C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 100) = 0

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Post injection 2: quantity specified value A7_PQ35_POST_INJ_2_QTY_SPECConfirmed

  • Request22 16 3B
  • Service 22DID 163B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 100) = 0

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Post injection 3: quantity specified value A7_PQ35_POST_INJ_3_QTY_SPECConfirmed

  • Request22 16 7D
  • Service 22DID 167D
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 100) = 0

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Post-injection 1 duration A7_PQ35_POST_INJ_1_DURATIONConfirmed

  • Request22 14 CC
  • Service 22DID 14CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 × 0.4 ÷ 1000) = 0 ms

Formula
(val × 0.4 ÷ 1000)
Range
-13.1072 to 13.1068 ms
Unit
ms

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Post-injection 1 start position A7_PQ35_POST_INJ_1_STARTConfirmed

  • Request22 11 F4
  • Service 22DID 11F4
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 50) = 0 °

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Post-injection 2 duration A7_PQ35_POST_INJ_2_DURATIONConfirmed

  • Request22 14 CD
  • Service 22DID 14CD
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 × 0.4 ÷ 1000) = 0 ms

Formula
(val × 0.4 ÷ 1000)
Range
-13.1072 to 13.1068 ms
Unit
ms

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Post-injection 2 start position A7_PQ35_POST_INJ_2_STARTConfirmed

  • Request22 11 F3
  • Service 22DID 11F3
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 50) = 0 °

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Post-injection 3 activation duration A7_PQ35_POST_INJ_3_ACTIVATION_DURATIONConfirmed

  • Request22 14 CE
  • Service 22DID 14CE
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x1D5B = 7515 → (7515 × 0.4 ÷ 1000) = 3.006 ms

Formula
(val × 0.4 ÷ 1000)
Range
-13.1072 to 13.1068 ms
Unit
ms

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Post-injection 3 start position A7_PQ35_POST_INJ_3_STARTConfirmed

  • Request22 11 31
  • Service 22DID 1131
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 50) = 0 °

Formula
(val ÷ 50)
Range
-655.36 to 655.34 °
Unit
°

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Pressure before throttle valve - actual value A7_P_BEFORE_THROTTLE_ACT

  • Request22 11 EE
  • Service 22DID 11EE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 64)
Range
0 to 5119
Unit
Raw value

In testing for 2019 to 2026.

Pressure before throttle valve - sensor measured A7_P_BEFORE_THROTTLE

  • Request22 11 EF
  • Service 22DID 11EF
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 21333 ÷ 546125)
Range
0 to 2559
Unit
Raw value

In testing for 2019 to 2026.

Pressure sensor 1 temperature A7_MQB_DL382_P_SENSOR_1_TConfirmed

  • Request22 13 2A
  • Service 22DID 132A
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0029 = 41 → 41 °C

Formula
val
Range
-32768 to 32767 °C
Unit
°C

Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.

Pressure sensor 2 temperature A7_MQB_DL382_P_SENSOR_2_TConfirmed

  • Request22 13 2B
  • Service 22DID 132B
  • Module7E1 → 7E9
  • Every5 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0029 = 41 → 41 °C

Formula
val
Range
-32768 to 32767 °C
Unit
°C

Confirmed for 2020. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012.

Pressure supply actual pressure A7_MQB_DQ200_P_SUPPLY_ACTUAL_PConfirmed

  • Request22 11 91
  • Service 22DID 1191
  • Module7E1 → 7E9
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

0xA603 = -23037 → (-23037 ÷ 100) = -230.37 bar

Formula
(val ÷ 100)
Range
-327.68 to 327.67 bar
Unit
bar

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Pressure supply actual pressure analog digital value A7_MQB_DQ200_P_SUPPLY_ACTUAL_P_AD_VALUE

  • Request22 10 2D
  • Service 22DID 102D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.

Radiator fan commanded duty A7_CLIMATE_RAD_FAN_CMD_DUTYConfirmed

  • Request22 26 07
  • Service 22DID 2607
  • Module746 → 7B0
  • Every2 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 ÷ 2.5) = 0 %

Formula
(val ÷ 2.5)
Range
0 to 100 %
Unit
%

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Radiator outlet coolant temperature commanded A7_PQ35_RAD_COOL_T_CMDConfirmed

  • Request22 11 11
  • Service 22DID 1111
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0E25 = 3621 → (3621 ÷ 10 − 273.1) = 89 °C

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Radiator output coolant temp: actual A7_PQ35_RADIATOR_OUTPUT_COOLANT_T_ACTUALConfirmed

  • Request22 16 26
  • Service 22DID 1626
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0B4B = 2891 → (2891 ÷ 10 − 273.1) = 16 °C

Formula
(val ÷ 10 − 273.1)
Range
-273.1 to 6280.4 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Rated drive torque A7_RATED_DRIVE_TQ

  • Request22 14 A1
  • Service 22DID 14A1
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 10)
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2019 to 2026.

Reached maximum temperature A7_PQ35_REACHED_MAXIMUM_T

  • Request22 11 17
  • Service 22DID 1117
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.

Reducing agent tank volume, act. value filtered A7_REDUCING_AGENT_TANK_ACT

  • Request22 1A 6C
  • Service 22DID 1A6C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 500)
Range
0 to 131 L
Unit
L

In testing for 2019 to 2026.

Refrigerant pressure A7_CLIMATE_REFRIG_PConfirmed

  • Request22 26 05
  • Service 22DID 2605
  • Module746 → 7B0
  • Every5 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 7 of the reply, 8 bits.

0x22 = 34 → (34 ÷ 5) = 6.8 bar

Formula
(val ÷ 5)
Range
0 to 51 bar
Unit
bar

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Refrigerant pressure A7_REFRIGERANT_P

  • Request22 26 05
  • Service 22DID 2605
  • Module70E → 778
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 bar
Unit
bar

In testing for 2019 to 2026.

Regulation factor total A7_PQ35_REG_FACTORConfirmed

  • Request22 10 E4
  • Service 22DID 10E4
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x2000 = 8192 → (8192 ÷ 10000) = 0.8192 %

Formula
(val ÷ 10000)
Range
0 to 3.276 %
Unit
%

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Relative load value A7_REL_LOAD

  • Request22 12 16
  • Service 22DID 1216
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 913 ÷ 38950)
Range
0 to 1536
Unit
Number

In testing for 2019 to 2026.

Requested torque, amount for auxiliary units A7_REQ_TQ_AMOUNT

  • Request22 10 BE
  • Service 22DID 10BE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2019 to 2026.

Reserve torque A7_RESERVE_TQ

  • Request22 10 6A
  • Service 22DID 106A
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2019 to 2026.

Result of crankcase ventilation test, fail A7_RESULT_CRANKCASE

  • Request22 15 CC
  • Service 22DID 15CC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Result of crankcase ventilation test, successful A7_RESULT_CRANKCASE_VENTILATION_TEST

  • Request22 15 CB
  • Service 22DID 15CB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2019 to 2026.

Right central air outlet temperature A7_RIGHT_CENTRAL_AIR_T

  • Request22 42 C6
  • Service 22DID 42C6
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2019 to 2026.

Right foot well air outlet temperature A7_RIGHT_FOOTWELL_AIR_T

  • Request22 42 BD
  • Service 22DID 42BD
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2019 to 2026.

Right rear foot well air outlet temperature A7_RIGHT_REAR_FOOTWELL_T

  • Request22 42 C2
  • Service 22DID 42C2
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2019 to 2026.

Right rear upper air outlet temperature A7_RIGHT_REAR_HI_AIR_T

  • Request22 42 C0
  • Service 22DID 42C0
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2019 to 2026.

Right side air outlet temperature A7_RIGHT_SIDE_AIR_T

  • Request22 42 C4
  • Service 22DID 42C4
  • Module70E → 778
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 50)
Range
-50 to 4045 °C
Unit
°C

In testing for 2019 to 2026.

Route data, active A7_ROUTE_DATA_ACTIVE

  • Request22 28 2C
  • Service 22DID 282C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Sensor for particle filter differential pressure, raw value A7_SENS_PARTICLE_FLT_P

  • Request22 39 E9
  • Service 22DID 39E9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767
Unit
Raw value

In testing for 2019 to 2026.

Service interval extension, max oil level A7_WIV_MAX_OIL_LEVEL

  • Request22 12 30
  • Service 22DID 1230
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262 mm
Unit
mm

In testing for 2019 to 2026.

Service interval extension, min oil level A7_WIV_MIN_OIL_LEVEL

  • Request22 12 31
  • Service 22DID 1231
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 250)
Range
0 to 262 mm
Unit
mm

In testing for 2019 to 2026.

Service limit value A7_PQ35_SRV_LIMConfirmed

  • Request22 12 CB
  • Service 22DID 12CB
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0D20 = 3360 → (3360 ÷ 100) = 33.6

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2020. Supported for 2021.

SIM card, SIM card in main unit A7_SIM_CARD_SIM_CARD

  • Request22 18 14
  • Service 22DID 1814
  • Module773 → 7DD
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Simulated DPF temperature A7_SIMULATED_DPF_T

  • Request22 3D 7F
  • Service 22DID 3D7F
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10 − 273.1)
Range
-3549 to 3003 °C
Unit
°C

In testing for 2019 to 2026.

Smoke limit A7_PQ35_LIM_SMOKEConfirmed

  • Request22 13 01
  • Service 22DID 1301
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x06D6 = 1750 → (1750 ÷ 10) = 175 N·m

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Solenoid current A7_SOLENOID_CURRENT

  • Request22 18 00
  • Service 22DID 1800
  • Module70F → 779
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 12207 ÷ 6250000)
Range
-63.99 to 63.99 A
Unit
A

In testing for 2019 to 2026.

Spark efficiency deviation at part load A7_SPARK_EFFICIENCY_DEV

  • Request22 11 2D
  • Service 22DID 112D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 781 ÷ 1000)
Range
0 to 199 %
Unit
%

In testing for 2019 to 2026.

Static torque limitation A7_STATIC_TQ_LIM

  • Request22 10 66
  • Service 22DID 1066
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2019 to 2026.

Status CC ECU, temperature. st.disc A7_STAT_CC_ECU_T_ST

  • Request22 11 0A
  • Service 22DID 110A
  • Module70F → 779
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 39 ÷ 2500)
Range
-511 to 511 °C
Unit
°C

In testing for 2019 to 2026.

Temperature after evaporator A7_CLIMATE_T_AFTER_EVAPConfirmed

  • Request22 26 12
  • Service 22DID 2612
  • Module746 → 7B0
  • Every5 s
  • Testing for 2010, 2013 to 2026

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 3)
Range
-42.624 to 42.291 °C
Unit
°C

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Temperature status, controller A7_STAT_NIA_T

  • Request22 11 01
  • Service 22DID 1101
  • Module70F → 779
  • Every5 s
  • Testing

Bits 136 to 151 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2019 to 2026.

Temperature status, RPS A7_STAT_NIA_T_RPS

  • Request22 11 01
  • Service 22DID 1101
  • Module70F → 779
  • Every5 s
  • Testing

Bits 152 to 167 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2019 to 2026.

Temperature status, SBC A7_STAT_NIA_T_SBC

  • Request22 11 01
  • Service 22DID 1101
  • Module70F → 779
  • Every5 s
  • Testing

Bits 168 to 183 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 °C
Unit
°C

In testing for 2019 to 2026.

Thermostat, actual A7_THERMOSTAT_ACT

  • Request22 44 18
  • Service 22DID 4418
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 12207 ÷ 1000000)
Range
0 to 799 %
Unit
%

In testing for 2019 to 2026.

Thermostat, commanded A7_THERMOSTAT_CMD

  • Request22 44 17
  • Service 22DID 4417
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 12207 ÷ 1000000)
Range
0 to 799 %
Unit
%

In testing for 2019 to 2026.

Throttle regulator nominal value A7_THROTTLE_REGULATOR

Pelican can show this parameter as the throttle position.

  • Request22 16 C5
  • Service 22DID 16C5
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128)
Range
0 to 511 %
Unit
%

In testing for 2019 to 2026.

Throttle valve adapter position A7_PQ35_THROT_VALVE_ADAPTConfirmed

  • Request22 12 FC
  • Service 22DID 12FC
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0519 = 1305 → (1305 ÷ 100) = 13.05 %

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Time in after-run A7_TIME_AFTERRUN

  • Request22 10 3A
  • Service 22DID 103A
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 s
Unit
s

In testing for 2019 to 2026.

Time since reset A7_TIME_SINCE_RESET

  • Request22 10 3B
  • Service 22DID 103B
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 30)
Range
0 to 7650 ms
Unit
ms

In testing for 2019 to 2026.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Request01 0E
  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2020. Supported for 2021.

Torque factor A7_TQ_FACTOR

  • Request22 21 19
  • Service 22DID 2119
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Torque increase request from ESP A7_TQ_INCREASE_REQ_ESP

  • Request22 13 40
  • Service 22DID 1340
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 10)
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2019 to 2026.

Torque limit A7_PQ35_LIM_TRQConfirmed

  • Request22 10 6B
  • Service 22DID 106B
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0674 = 1652 → (1652 ÷ 10) = 165.2 N·m

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 N·m
Unit
N·m

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Torque limitation A7_TQ_LIM

  • Request22 10 7D
  • Service 22DID 107D
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 N·m
Unit
N·m

In testing for 2019 to 2026.

Torque loss adaptation at idle A7_TQ_LOSS_ADPT_IDLE

  • Request22 12 25
  • Service 22DID 1225
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2019 to 2026.

Torque loss adaptation, A/C compressor A7_TQ_LOSS_ADPT_AC_COMP

  • Request22 12 23
  • Service 22DID 1223
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 N·m
Unit
N·m

In testing for 2019 to 2026.

Torque reduction due to exhaust temperature A7_PQ35_TRQ_RED_EXH_TConfirmed

  • Request22 10 E3
  • Service 22DID 10E3
  • Module7E0 → 7E8
  • Every250 ms
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x2000 = 8192 → (8192 ÷ 10000) = 0.8192

Formula
(val ÷ 10000)
Range
-3.2768 to 3.276
Unit
Number

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Torque reduction request from ESP A7_TQ_REDUCTION_REQ_ESP

  • Request22 13 3F
  • Service 22DID 133F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 31 of the reply, 32 bits. The value is signed.

Formula
(val ÷ 10)
Range
-214748364 to 214748364 N·m
Unit
N·m

In testing for 2019 to 2026.

Torque transmitting function, ratio A7_TQ_TRANSMITTING

  • Request22 21 05
  • Service 22DID 2105
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553
Unit
Number

In testing for 2019 to 2026.

Total mass of gasoline and ethyl alcohol in oil A7_TOT_MASS_GASOLINE

  • Request22 17 13
  • Service 22DID 1713
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.021333)
Range
0 to 1398
Unit
Raw value

In testing for 2019 to 2026.

Transmission drag torque A7_TCM_DRAG_TQ

  • Request22 10 21
  • Service 22DID 1021
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2019 to 2026.

Transmission torque losses A7_TCM_TQ_LOSSES

  • Request22 10 22
  • Service 22DID 1022
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 N·m
Unit
N·m

In testing for 2019 to 2026.

Turbine actuator 1 bank 1 activation A7_PQ35_TURB_ACT_1_B1Confirmed

  • Request22 11 7E
  • Service 22DID 117E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x199A = 6554 → (6554 ÷ 100) = 65.54 %

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Turbine actuator 1 bank 1: activation A7_ACT

  • Request22 11 2C
  • Service 22DID 112C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2020.

Valve lift system, result of last switch, intake A7_VLV_LIFT_SYSTEM

  • Request22 16 BE
  • Service 22DID 16BE
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Valve lift system, valve lift, exhaust A7_VLV_LIFT_SYSTEM_VLV

  • Request22 16 BB
  • Service 22DID 16BB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Valve lift system, valve lift, intake A7_VLV_LIFT_SYSTEM_VLV_LIFT

  • Request22 16 BA
  • Service 22DID 16BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2019 to 2026.

Valve timing, the difference between the, actual and the set angle A7_VLV_TIM_DIFF_ACT_SET

  • Request22 10 EC
  • Service 22DID 10EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 64)
Range
-512 to 511 °
Unit
°

In testing for 2019 to 2026.

Variable valve timing, intake, bank 1, regulation A7_VARIABLE_VLV_TIM_INT_1

  • Request22 12 7B
  • Service 22DID 127B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0030517549)
Range
0 to 199 %
Unit
%

In testing for 2019 to 2026.

Variable valve timing, intake, bank 1, switch on A7_VARIABLE_VLV_TIM_INT_1_ON

  • Request22 12 7D
  • Service 22DID 127D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0030517549)
Range
0 to 199 %
Unit
%

In testing for 2019 to 2026.

Wear index A7_PQ35_WEAR_IDXConfirmed

  • Request22 10 E2
  • Service 22DID 10E2
  • Module7E0 → 7E8
  • Every3600 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0003 = 3 → 3 m

Formula
val
Range
-32768 to 32767 m
Unit
m

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Engine › DPF

Diesel particulate filter field regeneration lock status A7_PQ35_DPF_FIELD_REGEN_LOCKConfirmed

  • Request22 11 C1
  • Service 22DID 11C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Diesel particulate filter fuel consumption since last regeneration A7_PQ35_DPF_FUEL_CON_REGENConfirmed

  • Request22 11 5A
  • Service 22DID 115A
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0AA8 = 2728 → (2728 ÷ 100) = 27.28 L

Formula
(val ÷ 100)
Range
-327.68 to 327.67 L
Unit
L

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Distance since last regeneration A7_PQ35_DIST_LAST_REGENConfirmed

  • Request22 11 56
  • Service 22DID 1156
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2010, 2013 to 2015, 2017 to 2026

Example reply from a 2016 Audi A7.

Bits 0 to 31 of the reply, 32 bits.

0x00049BE3 = 302051 → (302051 ÷ 1000) = 302.051 km

Formula
(val ÷ 1000)
Range
0 to 4294967 km
Unit
km

Confirmed for 2011 to 2012, 2016. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026. Not supported for 2020.

Regeneration duration A7_PQ35_REGEN_DURConfirmed

  • Request22 13 47
  • Service 22DID 1347
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 31 of the reply, 32 bits.

0x00000000 = 0 → 0 min

Formula
val
Range
0 to 4294967295 min
Unit
min

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Service regeneration status A7_PQ35_SRV_REGEN_STATConfirmed

  • Request22 11 5C
  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 7 of the reply, 8 bits.

0x05 = 5 → 5

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Soot index A7_PQ35_SOOT_IDXConfirmed

  • Request22 13 54
  • Service 22DID 1354
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → 0 m

Formula
val
Range
-32768 to 32767 m
Unit
m

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2019, 2021 to 2026. Not supported for 2020.

Soot mass calculated A7_PQ35_SOOT_MASS_CALCConfirmed

  • Request22 11 4F
  • Service 22DID 114F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x3E08 = 15880 → (15880 ÷ 100) = 158.8

Formula
(val ÷ 100)
Range
0 to 655.35
Unit
Raw value

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Soot mass measured A7_PQ35_SOOT_MASS_MEASConfirmed

  • Request22 11 4E
  • Service 22DID 114E
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0039 = 57 → (57 ÷ 100) = 0.57

Formula
(val ÷ 100)
Range
-327.68 to 327.67
Unit
Raw value

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Engine › EGR

High press EGR closing v2 A7_PQ35_HIGH_P_EGR_CLOSING_VAR_2Confirmed

  • Request22 F4 2C
  • Service 22DID F42C
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x15 = 21 → 21 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Engine › Internal

Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020.

Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020.

Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020.

Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020.

Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020.

Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed

  • Request01 70
  • Service 01PID 70
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020.

IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020.

IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020.

IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020.

IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020.

IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020.

IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020.

Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2020.

Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2020.

Engine › OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2020. Supported for 2021.

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2012. Supported for 2016.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2020. Supported for 2021.

Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed

  • Request01 24
  • Service 01PID 24
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 8196)
Range
0 to 7.999 V
Unit
V

Confirmed for 2012. Supported for 2016.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?