Audi A7

Trip parameters

The Audi A7 has 33 trip parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Odometer, alternate A7_PQ35_ODO_2Confirmed

Pelican can show this parameter as the odometer.

  • Request22 16 A9
  • Service 22DID 16A9
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 31 of the reply, 32 bits.

0x000300DA = 196826 → 196,826 km

Formula
val
Range
0 to 4294967295 km
Unit
km

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Average consumption, category 0 A7_AVG_CSMP_CAT0Confirmed

  • Request22 2A B7
  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2010 to 2020, 2022 to 2026

Example reply from a 2021 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x0096 = 150 → (150 ÷ 10) = 15 kWh

Formula
(val ÷ 10)
Range
0 to 6553 kWh
Unit
kWh

Confirmed for 2021. In testing for 2010, 2013 to 2015, 2017 to 2019, 2022 to 2026. Not supported for 2011 to 2012, 2016, 2020.

Average consumption, category 1 A7_AVG_CSMP_CAT1Confirmed

  • Request22 2A B7
  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2010 to 2020, 2022 to 2026

Example reply from a 2021 Audi A7.

Bits 16 to 31 of the reply, 16 bits.

0x0096 = 150 → (150 ÷ 10) = 15 kWh

Formula
(val ÷ 10)
Range
0 to 6553 kWh
Unit
kWh

Confirmed for 2021. In testing for 2010, 2013 to 2015, 2017 to 2019, 2022 to 2026. Not supported for 2011 to 2012, 2016, 2020.

Average consumption, category 2 A7_AVG_CSMP_CAT2Confirmed

  • Request22 2A B7
  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2010 to 2020, 2022 to 2026

Example reply from a 2021 Audi A7.

Bits 32 to 47 of the reply, 16 bits.

0x0096 = 150 → (150 ÷ 10) = 15 kWh

Formula
(val ÷ 10)
Range
0 to 6553 kWh
Unit
kWh

Confirmed for 2021. In testing for 2010, 2013 to 2015, 2017 to 2019, 2022 to 2026. Not supported for 2011 to 2012, 2016, 2020.

Average consumption, category 3 A7_AVG_CSMP_CAT3Confirmed

  • Request22 2A B7
  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2010 to 2020, 2022 to 2026

Example reply from a 2021 Audi A7.

Bits 48 to 63 of the reply, 16 bits.

0x0096 = 150 → (150 ÷ 10) = 15 kWh

Formula
(val ÷ 10)
Range
0 to 6553 kWh
Unit
kWh

Confirmed for 2021. In testing for 2010, 2013 to 2015, 2017 to 2019, 2022 to 2026. Not supported for 2011 to 2012, 2016, 2020.

Average consumption, category 4 A7_AVG_CSMP_CAT4Confirmed

  • Request22 2A B7
  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2010 to 2020, 2022 to 2026

Example reply from a 2021 Audi A7.

Bits 64 to 79 of the reply, 16 bits.

0x0096 = 150 → (150 ÷ 10) = 15 kWh

Formula
(val ÷ 10)
Range
0 to 6553 kWh
Unit
kWh

Confirmed for 2021. In testing for 2010, 2013 to 2015, 2017 to 2019, 2022 to 2026. Not supported for 2011 to 2012, 2016, 2020.

Average consumption, category 5 A7_AVG_CSMP_CAT5Confirmed

  • Request22 2A B7
  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2010 to 2020, 2022 to 2026

Example reply from a 2021 Audi A7.

Bits 80 to 95 of the reply, 16 bits.

0x0096 = 150 → (150 ÷ 10) = 15 kWh

Formula
(val ÷ 10)
Range
0 to 6553 kWh
Unit
kWh

Confirmed for 2021. In testing for 2010, 2013 to 2015, 2017 to 2019, 2022 to 2026. Not supported for 2011 to 2012, 2016, 2020.

Average consumption, category 6 A7_AVG_CSMP_CAT6Confirmed

  • Request22 2A B7
  • Service 22DID 2AB7
  • Module710 → 77A
  • Every5 s
  • Testing for 2010 to 2020, 2022 to 2026

Example reply from a 2021 Audi A7.

Bits 96 to 111 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10) = 0 kWh

Formula
(val ÷ 10)
Range
0 to 6553 kWh
Unit
kWh

Confirmed for 2021. In testing for 2010, 2013 to 2015, 2017 to 2019, 2022 to 2026. Not supported for 2011 to 2012, 2016, 2020.

Clutch 1 adaptation kiss point part 1 odometer reading A7_PQ35_CLUTCH_1_ADAPT_KISS_POINT_PART_1_ODO_READINGConfirmed

  • Request22 10 CA
  • Service 22DID 10CA
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

0x0000 = 0 → (0 × 10) = 0 km

Formula
(val × 10)
Range
0 to 655350 km
Unit
km

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Clutch 2 adaptation kiss point part 1 odometer reading A7_PQ35_CLUTCH_2_ADAPT_KISS_POINT_PART_1_ODO_READINGConfirmed

  • Request22 10 EB
  • Service 22DID 10EB
  • Module7E1 → 7E9
  • Every3600 s
  • Testing for 2010, 2013 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.

0x8002 = 32770 → (32770 × 10) = 327,700 km

Formula
(val × 10)
Range
0 to 655350 km
Unit
km

Confirmed for 2011 to 2012, 2020. In testing for 2010, 2013 to 2019, 2021 to 2026.

Diesel particulate filter distance since last regeneration A7_DPF_DIST_SINCE_REGEN

  • Request22 20 8D
  • Service 22DID 208D
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 km
Unit
km

In testing for 2019 to 2026.

Diesel particulate filter distance since last regeneration, bank 1 A7_DPF_DIST_SINCE_REGEN_1

  • Request22 14 B8
  • Service 22DID 14B8
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 km
Unit
km

In testing for 2010 to 2018.

Diesel particulate filter distance since last regeneration, bank 2 A7_DPF_DIST_SINCE_REGEN_2

  • Request22 14 60
  • Service 22DID 1460
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 km
Unit
km

In testing for 2010 to 2018.

Distance to detected pedestrian A7_DIST_DETECTED

  • Request22 F4 1B
  • Service 22DID F41B
  • Module74F → 7B9
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383 m
Unit
m

In testing for 2019 to 2026.

Odometer A7_ODO_7E1_2

Pelican can show this parameter as the odometer.

  • Request22 10 3D
  • Service 22DID 103D
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2019 to 2026.

Odometer #3 A7_PQ35_ODO_3

Pelican can show this parameter as the odometer.

  • Request22 10 1A
  • Service 22DID 101A
  • Module7E1 → 7E9
  • Every30 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 km
Unit
km

In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2016, 2020.

Odometer at oxidation catalytic converter replacement A7_ODO_OXYDATION

  • Request22 4F 3F
  • Service 22DID 4F3F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2019 to 2026.

Odometer at SCR catalytic converter replacement A7_ODO_SCR_CATALYTIC

  • Request22 4F 41
  • Service 22DID 4F41
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2019 to 2026.

Odometer reading at DPF replace A7_ODO_READING_DPF

  • Request22 25 FE
  • Service 22DID 25FE
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2019 to 2026.

Odometer reading when changing DPF A7_ODO_READING_CHANGING

  • Request22 4F 40
  • Service 22DID 4F40
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
val
Range
0 to 4294967295 km
Unit
km

In testing for 2019 to 2026.

Odometer, alternate A7_PQ35_ODO_2Confirmed

Pelican can show this parameter as the odometer.

  • Request22 16 A9
  • Service 22DID 16A9
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2010, 2013 to 2026

Example reply from a 2012 Audi A7.

Bits 0 to 31 of the reply, 32 bits.

0x000300DA = 196826 → 196,826 km

Formula
val
Range
0 to 4294967295 km
Unit
km

Confirmed for 2011 to 2012. In testing for 2010, 2013 to 2026.

Odometer, alternative 2 A7_ODO_3Confirmed

Pelican can show this parameter as the odometer.

  • Request22 10 E0
  • Service 22DID 10E0
  • Module7E0 → 7E8
  • Every30 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 31 of the reply, 32 bits.

0x0001220F = 74255 → 74,255 km

Formula
val
Range
0 to 4294967295 km
Unit
km

Confirmed for 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2016.

Odometer, high resolution A7_ODO_HDConfirmed

Pelican can show this parameter as the odometer.

  • Request22 11 60
  • Service 22DID 1160
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2010 to 2019, 2021 to 2026

Example reply from a 2020 Audi A7.

Bits 0 to 31 of the reply, 32 bits.

0x0466731A = 73823002 → (73823002 ÷ 1000) = 73,823.002 km

Formula
(val ÷ 1000)
Range
0 to 4294967.295 km
Unit
km

Confirmed for 2020. In testing for 2010, 2013 to 2015, 2017 to 2019, 2021 to 2026. Not supported for 2011 to 2012, 2016.

Odometer, mileage, HR A7_ODO_MILEAGE_HR

Pelican can show this parameter as the odometer.

  • Request22 22 B8
  • Service 22DID 22B8
  • Module714 → 77E
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 1000)
Range
0 to 4294967 km
Unit
km

In testing for 2019 to 2026.

Range remaining A7_RANGE_V2Confirmed

Pelican can show this parameter as the electric range.

  • Request22 2A B6
  • Service 22DID 2AB6
  • Module710 → 77A
  • Every5 s
  • Testing for 2010 to 2020, 2022 to 2026

Example reply from a 2021 Audi A7.

Bits 0 to 15 of the reply, 16 bits.

0x00CD = 205 → 205 mi

Formula
val
Range
0 to 65535 mi
Unit
mi

Confirmed for 2021. In testing for 2010, 2013 to 2015, 2017 to 2019, 2022 to 2026. Not supported for 2011 to 2012, 2016, 2020.

Remaining distance until reducing agent deficiency A7_REMAINING_DIST_UNTIL

  • Request22 29 B1
  • Service 22DID 29B1
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 31 of the reply, 32 bits.

Formula
(val ÷ 20)
Range
0 to 214748364 km
Unit
km

In testing for 2019 to 2026.

Torque converter time in temperature range 1 A7_TQ_CONV_TIME_T_RANGE_1

  • Request22 17 FC
  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 23 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2019 to 2026.

Torque converter time in temperature range 2 A7_TQ_CONV_TIME_T_RANGE_2

  • Request22 17 FC
  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 24 to 47 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2019 to 2026.

Torque converter time in temperature range 3 A7_TQ_CONV_TIME_T_RANGE_3

  • Request22 17 FC
  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 71 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2019 to 2026.

Torque converter time in temperature range 4 A7_TQ_CONV_TIME_T_RANGE_4

  • Request22 17 FC
  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 72 to 95 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2019 to 2026.

Torque converter time in temperature range 5 A7_TQ_CONV_TIME_T_RANGE_5

  • Request22 17 FC
  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 96 to 119 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2019 to 2026.

Torque converter time in temperature range 6 A7_TQ_CONV_TIME_T_RANGE_6

  • Request22 17 FC
  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 120 to 143 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2019 to 2026.

Torque converter time in temperature range 7 A7_TQ_CONV_TIME_T_RANGE_7

  • Request22 17 FC
  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 144 to 167 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2019 to 2026.

Torque converter time in temperature range 8 A7_TQ_CONV_TIME_T_RANGE_8

  • Request22 17 FC
  • Service 22DID 17FC
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 168 to 191 of the reply, 24 bits.

Formula
val
Range
0 to 16777215 min
Unit
min

In testing for 2019 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.