Battery parameters
The Toyota Yaris has 173 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
+BM voltage YARIS_BM_V
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1998 to 2006, 2008 to 2026
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
In testing for 1998 to 2006, 2008 to 2026.
1st turbocharger outlet pressure, control valve YARIS_1ST_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 1998 to 2026.
2nd turbocharger outlet pressure YARIS_2ND_TRUBOCHARGER_OUTLET_P
- Request
22 11 AF - Service 22
DID 11AF - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 1998 to 2026.
2nd turbocharger outlet pressure, control valve YARIS_2ND_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 1998 to 2026.
12V battery current YARIS_12V_CConfirmed
- Request
22 15 F7 - Service 22
DID 15F7 - Module
7D2 → 7DA - Every
500 ms - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 0 to 15 of the reply, 16 bits.
0x6F63 = 28515 → (28515 × 38.147 ÷ 10000 − 125) = -16.22383 A
- Formula
(val × 38.147 ÷ 10000 − 125)- Range
- -125 to 124 A
- Unit
- A
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2007, 2010, 2015, 2017 to 2018, 2022 to 2023.
12V battery temperature YARIS_12V_TConfirmed
- Request
22 15 F8 - Service 22
DID 15F8 - Module
7D2 → 7DA - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 0 to 15 of the reply, 16 bits.
0x017C = 380 → (380 ÷ 10 − 40) = -2 °C
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2007, 2010, 2015, 2017 to 2018, 2022 to 2023.
12V battery voltage YARIS_12V_V_V2Confirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 15 EE - Service 22
DID 15EE - Module
7D2 → 7DA - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 0 to 7 of the reply, 8 bits.
0x24 = 36 → (36 × 0.31448 + 0.0125) = 11.33378 V
- Formula
(val × 0.31448 + 0.0125)- Range
- 0 to 80.2 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2007, 2010, 2015, 2017 to 2018, 2022 to 2023.
12V battery voltage before system main relay YARIS_12V_BAT_V_BEFORE_SMR
- Request
22 10 7E - Service 22
DID 107E - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 61 ÷ 50000 + 11.25)- Range
- 0 to 11.56 V
- Unit
- V
In testing for 2024 to 2026.
12V battery voltage smoothed YARIS_12V_BAT_V_SMOOTHED
- Request
22 1F 42 - Service 22
DID 1F42 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2024 to 2026.
Aux battery voltage YARIS_AUX_BAT_V
- Request
22 10 02 - Service 22
DID 1002 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 61 ÷ 50000)- Range
- 0 to 79.95 V
- Unit
- V
In testing for 2024 to 2026.
Aux. battery capacity after IG OFF YARIS_AUX_BAT_CAP_AFTER_IG_OFF
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 1998 to 2026.
Aux. battery capacity after IG ON YARIS_AUX_BAT_CAP_AFTER_IG_ON
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 1998 to 2026.
Auxiliary battery current YARIS_AUXILIARY_BAT
- Request
22 18 02 - Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2525 ÷ 13107 − 12500)- Range
- -12500 to -12451 A
- Unit
- A
In testing for 2024 to 2026.
Battery current YARIS_BAT_CURRENTConfirmed
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing for 1998 to 2006, 2008 to 2026
Example reply from a 2007 Toyota Yaris.
Bits 0 to 15 of the reply, 16 bits.
0x2FD6 = 12246 → (12246 × 50 ÷ 13107 − 125) = -78.284504 A
- Formula
(val × 50 ÷ 13107 − 125)- Range
- -125 to 124.9 A
- Unit
- A
Confirmed for 2007. In testing for 1998 to 2006, 2008 to 2026.
Battery current YARIS_BAT_CURRENT_700
- Request
22 15 F7 - Service 22
DID 15F7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 49 ÷ 12850 − 125)- Range
- -125 to 124.9 A
- Unit
- A
In testing for 1998 to 2026.
Battery heater temperature YARIS_BAT_HEATER_T
- Request
22 18 24 - Service 22
DID 1824 - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery status of full charge YARIS_BAT_STAT_FULL_CHG
- Request
22 15 E5 - Service 22
DID 15E5 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 255 ÷ 2)- Range
- 0 to 32512.5 Ah
- Unit
- Ah
In testing for 1998 to 2026.
Battery temperature YARIS_BAT_T
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing for 1998 to 2006, 2008 to 2026
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 6513.5 °C
- Unit
- °C
In testing for 1998 to 2006, 2008 to 2026.
Battery temperature YARIS_BAT_T_700
- Request
22 15 F8 - Service 22
DID 15F8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1998 to 2026.
Battery temperature YARIS_BAT_T_700_2
- Request
22 1F F8 - Service 22
DID 1FF8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 40)- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 1998 to 2026.
Battery temperature 01 YARIS_BAT_T_01
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 02 YARIS_BAT_T_02
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 03 YARIS_BAT_T_03
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 04 YARIS_BAT_T_04
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 05 YARIS_BAT_T_05
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 06 YARIS_BAT_T_06
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 07 YARIS_BAT_T_07
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 08 YARIS_BAT_T_08
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 09 YARIS_BAT_T_09
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 10 YARIS_BAT_T_10
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 11 YARIS_BAT_T_11
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 12 YARIS_BAT_T_12
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 13 YARIS_BAT_T_13
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 14 YARIS_BAT_T_14
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 15 YARIS_BAT_T_15
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery temperature 16 YARIS_BAT_T_16
- Request
22 18 14 - Service 22
DID 1814 - Module
747 → 74F - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val × 19531 ÷ 5000000 − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024 to 2026.
Battery voltage YARIS_12V_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 02 - Service 22
DID 1002 - Module
700 → 708 - Every
5 s - Testing for 1998 to 2023, 2026
Example reply from a 2025 Toyota Yaris.
Bits 0 to 15 of the reply, 16 bits.
0x23D8 = 9176 → (9176 × 12.207 ÷ 10000) = 11.201143 V
- Formula
(val × 12.207 ÷ 10000)- Range
- 0 to 79 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 1998 to 2006, 2008 to 2009, 2011 to 2013, 2016, 2018 to 2021, 2023, 2026. Not supported for 2007, 2010, 2014 to 2015, 2017, 2022.
Battery voltage YARIS_BAT_VConfirmed
- Request
21 13 - Service 21
PID 13 - Module
7C0 → 7C8 - Every
5 s - Testing for 1998 to 2006, 2008 to 2014, 2016, 2018 to 2021, 2023 to 2026
Example reply from a 2022 Toyota Yaris.
Bits 0 to 7 of the reply, 8 bits.
0x88 = 136 → (136 ÷ 10) = 13.6 V
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2015, 2017, 2022. In testing for 1998 to 2006, 2008 to 2009, 2011 to 2014, 2016, 2018 to 2021, 2023, 2026. Supported for 2007. Not supported for 2010, 2024 to 2025.
Battery voltage YARIS_BATTERY_VOLTAGE_7E0Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 1998 to 2006, 2008 to 2009, 2011 to 2014
Example reply from a 2015 Toyota Yaris.
Bits 200 to 215 of the reply, 16 bits.
0x330A = 13066 → (13066 ÷ 1000) = 13.066 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2015. In testing for 1998 to 2006, 2008 to 2009, 2011 to 2014. Supported for 2007, 2010.
Battery voltage YARIS_BATTERY_VOLTAGE_7E0_V2Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2018 to 2020
Example reply from a 2017 Toyota Yaris.
Bits 208 to 223 of the reply, 16 bits.
0x3010 = 12304 → (12304 ÷ 1000) = 12.304 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2017. In testing for 2018 to 2020.
Battery voltage YARIS_BATTERY_VOLTAGE_7E0_V3Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2023, 2025 to 2026
Example reply from a 2024 Toyota Yaris.
Bits 200 to 215 of the reply, 16 bits.
0x31AA = 12714 → (12714 ÷ 1000) = 12.714 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2022, 2024. In testing for 2023, 2026. Not supported for 2025.
Charge contactor current YARIS_SCC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1998 to 2006, 2008 to 2009, 2011 to 2014, 2016, 2018 to 2021, 2023, 2026. Not supported for 2007, 2010, 2015, 2017, 2022, 2024 to 2025.
Charging integrated current of aux. battery YARIS_CHG_INTEGRATED
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 1998 to 2026.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2017 to 2018, 2023 to 2025. Supported for 2006 to 2008, 2010, 2013, 2015, 2020 to 2022.
Dark current of battery YARIS_DARK_CURRENT_BAT
- Request
22 15 E7 - Service 22
DID 15E7 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 1998 to 2026.
DC-DC converter high side voltage YARIS_DC_DC_CONV_HIGH_SIDE_V
- Request
22 11 1E - Service 22
DID 111E - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1220703 ÷ 10000000)- Range
- 0 to 7999 V
- Unit
- V
In testing for 2024 to 2026.
DC-DC converter low side voltage YARIS_DC_DC_CONV_LOW_SIDE_V
- Request
22 11 1D - Service 22
DID 111D - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1953 ÷ 25000)- Range
- 0 to 19.92 V
- Unit
- V
In testing for 2024 to 2026.
DC-DC converter, target voltage before charging YARIS_DC_DC_CONV_TGT_V
- Request
22 11 1F - Service 22
DID 111F - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1220703 ÷ 10000000)- Range
- 0 to 7999 V
- Unit
- V
In testing for 2024 to 2026.
Discharging integrated current of aux. battery YARIS_DISCHARGING
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 1998 to 2026.
Distance since last battery cable disconnection YARIS_DIST_SINCE_BAT_DISCConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
700 → 708 - Every
30 s - Testing for 1998 to 2023, 2026
Example reply from a 2025 Toyota Yaris.
Bits 0 to 15 of the reply, 16 bits.
0x2508 = 9480 → 9,480 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2024 to 2025. In testing for 1998 to 2000, 2002 to 2006, 2008 to 2009, 2011 to 2014, 2016, 2018 to 2021, 2023, 2026. Not supported for 2001, 2007, 2010, 2015, 2017, 2022.
HV battery charge voltage YARIS_HVBAT_CHRG_V
- Request
22 16 09 - Service 22
DID 1609 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 V
- Unit
- V
In testing for 2026. Not supported for 2007, 2010, 2015, 2017 to 2018, 2022 to 2025.
HV battery charge, maximum YARIS_HVBAT_SOC_MAXConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 8 to 15 of the reply, 8 bits.
0x41 = 65 → (65 ÷ 2) = 32.5 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2007, 2010, 2015, 2017 to 2018, 2022.
HV battery charge, minimum YARIS_HVBAT_SOC_MINConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 16 to 23 of the reply, 8 bits.
0x3B = 59 → (59 ÷ 2) = 29.5 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2007, 2010, 2015, 2017 to 2018, 2022.
HV battery current YARIS_HVBAT_CConfirmed
Pelican can show this parameter as the traction battery current.
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 32 to 47 of the reply, 16 bits. The value is signed.
0x070C = 1804 → (1804 ÷ 10) = 180.4 A
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2007, 2010, 2015, 2017 to 2018, 2022 to 2023.
HV battery maximum temperature YARIS_HVBAT_MAX_T
- Request
22 18 29 - Service 22
DID 1829 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2026. Not supported for 2007, 2010, 2015, 2017 to 2018, 2022 to 2025.
HV battery minimum temperature YARIS_HVBAT_MIN_T
- Request
22 18 2A - Service 22
DID 182A - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2026. Not supported for 2007, 2010, 2015, 2017 to 2018, 2022 to 2025.
HV battery voltage YARIS_HVBAT_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 16 to 31 of the reply, 16 bits.
0x2740 = 10048 → (10048 × 156.25 ÷ 10000) = 157 V
- Formula
(val × 156.25 ÷ 10000)- Range
- 0 to 1023 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2007, 2010, 2015, 2017 to 2018, 2022 to 2023.
Hybrid battery 1 fan YARIS_HYBRID_BAT_1_FAN
- Request
22 18 02 - Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2024 to 2026.
Hybrid battery temperature 1 YARIS_HYBRID_BAT_T_1
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2024 to 2026.
Hybrid battery temperature 2 YARIS_HYBRID_BAT_T_2
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 58)- Range
- -58 to 401 °F
- Unit
- °F
In testing for 2024 to 2026.
Hybrid battery temperature 3 YARIS_HYBRID_BAT_T_3
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2024 to 2026.
Initial engine battery voltage lower limit YARIS_INITIAL_ENG_BAT_V_LO
- Request
22 15 F6 - Service 22
DID 15F6 - Module
700 → 708 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1998 to 2026.
Main connector solenoid current YARIS_SMC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1998 to 2006, 2008 to 2009, 2011 to 2014, 2016, 2018 to 2021, 2023, 2026. Not supported for 2007, 2010, 2015, 2017, 2022, 2024 to 2025.
Main relay a, solenoid current YARIS_SLA_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1998 to 2006, 2008 to 2009, 2011 to 2014, 2016, 2018 to 2021, 2023, 2026. Not supported for 2007, 2010, 2015, 2017, 2022, 2024 to 2025.
Main relay r solenoid current YARIS_SLR_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1998 to 2006, 2008 to 2009, 2011 to 2014, 2016, 2018 to 2021, 2023, 2026. Not supported for 2007, 2010, 2015, 2017, 2022, 2024 to 2025.
Output speed sensor voltage YARIS_NOUT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 1998 to 2026.
Regenerative braking cooperation YARIS_REGEN_COOPERATION
- Request
21 58 - Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1998 to 2006, 2008 to 2009, 2011 to 2014, 2016, 2018 to 2021, 2023, 2026. Not supported for 2007, 2010, 2015, 2017, 2022, 2024 to 2025.
Regenerative operation YARIS_FR_REGEN_OPERATION
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1998 to 2006, 2008 to 2009, 2011 to 2014, 2016, 2018 to 2021, 2023, 2026. Not supported for 2007, 2010, 2015, 2017, 2022, 2024 to 2025.
Regenerative request YARIS_FR_REGEN_REQUEST
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 1998 to 2006, 2008 to 2009, 2011 to 2014, 2016, 2018 to 2021, 2023, 2026. Not supported for 2007, 2010, 2015, 2017, 2022, 2024 to 2025.
Relay control solenoid current YARIS_SRC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1998 to 2006, 2008 to 2009, 2011 to 2014, 2016, 2018 to 2021, 2023, 2026. Not supported for 2007, 2010, 2015, 2017, 2022, 2024 to 2025.
Service contactor solenoid current YARIS_SSC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 1998 to 2006, 2008 to 2009, 2011 to 2014, 2016, 2018 to 2021, 2023, 2026. Not supported for 2007, 2010, 2015, 2017, 2022, 2024 to 2025.
Sleep time of battery sensor YARIS_SLEEP_TIME_BATSENS
- Request
22 15 F0 - Service 22
DID 15F0 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 h
- Unit
- h
In testing for 1998 to 2026.
State of charge YARIS_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 1F 5B - Service 22
DID 1F5B - Module
7D2 → 7DA - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 0 to 7 of the reply, 8 bits.
0x4C = 76 → (76 × 100 ÷ 255) = 29.803922 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. In testing for 2026.
Turbine speed sensor voltage YARIS_NT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 1998 to 2026.
Vh-voltage after boosting YARIS_VH_V_AFTER_BOOSTING
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 2024 to 2026.
Vl-voltage before boosting YARIS_VL_V_BEFORE_BOOSTING
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 2024 to 2026.
Voltage of battery sensor YARIS_V_BATSENS
- Request
22 15 EE - Service 22
DID 15EE - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13333 ÷ 10922500)- Range
- 0 to 79.9979 V
- Unit
- V
In testing for 1998 to 2026.
Battery › Cells
HV battery cell #01 voltage YARIS_HVBAT_C01_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 0 to 15 of the reply, 16 bits.
0xA8DA = 43226 → (43226 × 5 ÷ 65535) = 3.297932 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #02 voltage YARIS_HVBAT_C02_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 16 to 31 of the reply, 16 bits.
0xA88A = 43146 → (43146 × 5 ÷ 65535) = 3.291829 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #03 voltage YARIS_HVBAT_C03_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 32 to 47 of the reply, 16 bits.
0xA8EA = 43242 → (43242 × 5 ÷ 65535) = 3.299153 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #04 voltage YARIS_HVBAT_C04_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #05 voltage YARIS_HVBAT_C05_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 64 to 79 of the reply, 16 bits.
0xA879 = 43129 → (43129 × 5 ÷ 65535) = 3.290532 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #06 voltage YARIS_HVBAT_C06_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #07 voltage YARIS_HVBAT_C07_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 96 to 111 of the reply, 16 bits.
0xA8EA = 43242 → (43242 × 5 ÷ 65535) = 3.299153 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #08 voltage YARIS_HVBAT_C08_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 112 to 127 of the reply, 16 bits.
0xA879 = 43129 → (43129 × 5 ÷ 65535) = 3.290532 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #09 voltage YARIS_HVBAT_C09_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #10 voltage YARIS_HVBAT_C10_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 144 to 159 of the reply, 16 bits.
0xA88A = 43146 → (43146 × 5 ÷ 65535) = 3.291829 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #11 voltage YARIS_HVBAT_C11_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 160 to 175 of the reply, 16 bits.
0xA869 = 43113 → (43113 × 5 ÷ 65535) = 3.289311 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #12 voltage YARIS_HVBAT_C12_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 176 to 191 of the reply, 16 bits.
0xA88A = 43146 → (43146 × 5 ÷ 65535) = 3.291829 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #13 voltage YARIS_HVBAT_C13_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #14 voltage YARIS_HVBAT_C14_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 208 to 223 of the reply, 16 bits.
0xA8AA = 43178 → (43178 × 5 ÷ 65535) = 3.29427 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #15 voltage YARIS_HVBAT_C15_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #16 voltage YARIS_HVBAT_C16_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 240 to 255 of the reply, 16 bits.
0xA879 = 43129 → (43129 × 5 ÷ 65535) = 3.290532 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #17 voltage YARIS_HVBAT_C17_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #18 voltage YARIS_HVBAT_C18_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 272 to 287 of the reply, 16 bits.
0xA89A = 43162 → (43162 × 5 ÷ 65535) = 3.29305 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #19 voltage YARIS_HVBAT_C19_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 288 to 303 of the reply, 16 bits.
0xA8CA = 43210 → (43210 × 5 ÷ 65535) = 3.296712 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #20 voltage YARIS_HVBAT_C20_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 304 to 319 of the reply, 16 bits.
0xA879 = 43129 → (43129 × 5 ÷ 65535) = 3.290532 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #21 voltage YARIS_HVBAT_C21_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #22 voltage YARIS_HVBAT_C22_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 336 to 351 of the reply, 16 bits.
0xA8AA = 43178 → (43178 × 5 ÷ 65535) = 3.29427 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #23 voltage YARIS_HVBAT_C23_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 352 to 367 of the reply, 16 bits.
0xA8EA = 43242 → (43242 × 5 ÷ 65535) = 3.299153 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #24 voltage YARIS_HVBAT_C24_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 368 to 383 of the reply, 16 bits.
0xA8CA = 43210 → (43210 × 5 ÷ 65535) = 3.296712 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #25 voltage YARIS_HVBAT_C25_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 384 to 399 of the reply, 16 bits.
0xA89A = 43162 → (43162 × 5 ÷ 65535) = 3.29305 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #26 voltage YARIS_HVBAT_C26_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 400 to 415 of the reply, 16 bits.
0xA88A = 43146 → (43146 × 5 ÷ 65535) = 3.291829 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #27 voltage YARIS_HVBAT_C27_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #28 voltage YARIS_HVBAT_C28_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #29 voltage YARIS_HVBAT_C29_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 448 to 463 of the reply, 16 bits.
0xA88A = 43146 → (43146 × 5 ÷ 65535) = 3.291829 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #30 voltage YARIS_HVBAT_C30_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 464 to 479 of the reply, 16 bits.
0xA8AA = 43178 → (43178 × 5 ÷ 65535) = 3.29427 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #31 voltage YARIS_HVBAT_C31_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #32 voltage YARIS_HVBAT_C32_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #33 voltage YARIS_HVBAT_C33_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 512 to 527 of the reply, 16 bits.
0xA88A = 43146 → (43146 × 5 ÷ 65535) = 3.291829 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #34 voltage YARIS_HVBAT_C34_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 528 to 543 of the reply, 16 bits.
0xA89A = 43162 → (43162 × 5 ÷ 65535) = 3.29305 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #35 voltage YARIS_HVBAT_C35_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 544 to 559 of the reply, 16 bits.
0xA8AA = 43178 → (43178 × 5 ÷ 65535) = 3.29427 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #36 voltage YARIS_HVBAT_C36_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 560 to 575 of the reply, 16 bits.
0xA88A = 43146 → (43146 × 5 ÷ 65535) = 3.291829 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #37 voltage YARIS_HVBAT_C37_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 576 to 591 of the reply, 16 bits.
0xA879 = 43129 → (43129 × 5 ÷ 65535) = 3.290532 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #38 voltage YARIS_HVBAT_C38_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 592 to 607 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #39 voltage YARIS_HVBAT_C39_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 608 to 623 of the reply, 16 bits.
0xA88A = 43146 → (43146 × 5 ÷ 65535) = 3.291829 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #40 voltage YARIS_HVBAT_C40_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 624 to 639 of the reply, 16 bits.
0xA88A = 43146 → (43146 × 5 ÷ 65535) = 3.291829 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #41 voltage YARIS_HVBAT_C41_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 640 to 655 of the reply, 16 bits.
0xA88A = 43146 → (43146 × 5 ÷ 65535) = 3.291829 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #42 voltage YARIS_HVBAT_C42_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 656 to 671 of the reply, 16 bits.
0xA89A = 43162 → (43162 × 5 ÷ 65535) = 3.29305 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #43 voltage YARIS_HVBAT_C43_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 672 to 687 of the reply, 16 bits.
0xA8AA = 43178 → (43178 × 5 ÷ 65535) = 3.29427 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #44 voltage YARIS_HVBAT_C44_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 688 to 703 of the reply, 16 bits.
0xA8AA = 43178 → (43178 × 5 ÷ 65535) = 3.29427 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #45 voltage YARIS_HVBAT_C45_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 704 to 719 of the reply, 16 bits.
0xA8AA = 43178 → (43178 × 5 ÷ 65535) = 3.29427 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #46 voltage YARIS_HVBAT_C46_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 720 to 735 of the reply, 16 bits.
0xA89A = 43162 → (43162 × 5 ÷ 65535) = 3.29305 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #47 voltage YARIS_HVBAT_C47_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 736 to 751 of the reply, 16 bits.
0xA8CA = 43210 → (43210 × 5 ÷ 65535) = 3.296712 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #48 voltage YARIS_HVBAT_C48_VConfirmed
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Example reply from a 2025 Toyota Yaris.
Bits 752 to 767 of the reply, 16 bits.
0xA8DA = 43226 → (43226 × 5 ÷ 65535) = 3.297932 V
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
Confirmed for 2024 to 2025. In testing for 2026. Not supported for 2018.
HV battery cell #49 voltage YARIS_HVBAT_C49_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 768 to 783 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #50 voltage YARIS_HVBAT_C50_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 784 to 799 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #51 voltage YARIS_HVBAT_C51_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 800 to 815 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #52 voltage YARIS_HVBAT_C52_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 816 to 831 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #53 voltage YARIS_HVBAT_C53_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 832 to 847 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #54 voltage YARIS_HVBAT_C54_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 848 to 863 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #55 voltage YARIS_HVBAT_C55_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 864 to 879 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #56 voltage YARIS_HVBAT_C56_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 880 to 895 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #57 voltage YARIS_HVBAT_C57_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 896 to 911 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #58 voltage YARIS_HVBAT_C58_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 912 to 927 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #59 voltage YARIS_HVBAT_C59_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 928 to 943 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #60 voltage YARIS_HVBAT_C60_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 944 to 959 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #61 voltage YARIS_HVBAT_C61_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 960 to 975 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #62 voltage YARIS_HVBAT_C62_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 976 to 991 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #63 voltage YARIS_HVBAT_C63_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #64 voltage YARIS_HVBAT_C64_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #65 voltage YARIS_HVBAT_C65_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #66 voltage YARIS_HVBAT_C66_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #67 voltage YARIS_HVBAT_C67_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #68 voltage YARIS_HVBAT_C68_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #69 voltage YARIS_HVBAT_C69_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #70 voltage YARIS_HVBAT_C70_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #71 voltage YARIS_HVBAT_C71_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #72 voltage YARIS_HVBAT_C72_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #73 voltage YARIS_HVBAT_C73_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #74 voltage YARIS_HVBAT_C74_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #75 voltage YARIS_HVBAT_C75_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #76 voltage YARIS_HVBAT_C76_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #77 voltage YARIS_HVBAT_C77_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #78 voltage YARIS_HVBAT_C78_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #79 voltage YARIS_HVBAT_C79_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #80 voltage YARIS_HVBAT_C80_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #81 voltage YARIS_HVBAT_C81_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #82 voltage YARIS_HVBAT_C82_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #83 voltage YARIS_HVBAT_C83_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #84 voltage YARIS_HVBAT_C84_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #85 voltage YARIS_HVBAT_C85_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #86 voltage YARIS_HVBAT_C86_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #87 voltage YARIS_HVBAT_C87_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #88 voltage YARIS_HVBAT_C88_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #89 voltage YARIS_HVBAT_C89_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #90 voltage YARIS_HVBAT_C90_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #91 voltage YARIS_HVBAT_C91_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #92 voltage YARIS_HVBAT_C92_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #93 voltage YARIS_HVBAT_C93_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #94 voltage YARIS_HVBAT_C94_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,488 to 1,503 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #95 voltage YARIS_HVBAT_C95_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,504 to 1,519 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.
HV battery cell #96 voltage YARIS_HVBAT_C96_V
- Request
22 18 2E - Service 22
DID 182E - Module
747 → 74F - Every
1 s - Testing for 2026
Bits 1,520 to 1,535 of the reply, 16 bits.
- Formula
(val × 5 ÷ 65535)- Range
- 0 to 5 V
- Unit
- V
In testing for 2026. Not supported for 2018, 2024 to 2025.